How To Build An Open Cabled Infrastructure In Medsea



Similar documents
MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

TrueAlarm Fire Alarm Systems

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).

Gigabit Ethernet Copper-to-Fiber Converters

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Demystifying Wireless for Real-World Measurement Applications

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Local-Area Network -LAN

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

NEW ROLES FOR UUVS IN INTELLIGENCE, SURVEILLANCE, AND RECONNAISSANCE

Temperature & Humidity SMS Alert Controller

Remote Level Monitoring Unit

Network Design. Yiannos Mylonas

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Dominion KX II-101-V2

The Optical Submarine Repeater and Its Associated Technologies

Products Range Overview. Products Range Overview. The ZigBee Plug & Play wireless Network for Building and Industrial Applications

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

Power over Ethernet technology for industrial Ethernet networks

TACTICAL FIBER OPTIC MODEMS U.S. Army and ANSI Standards

Phase Modular Finally the benefits of Modular ups are for all

AMPLIFIED HIGH SPEED FIBER PHOTODETECTOR USER S GUIDE

Power network telecommunication

Integrating Digiquartz MET3 and MET3A Broadband Meteorological Systems with Leica GX1200 Series GPS Receivers

SOHOware Long Reach Ethernet (LRE) Solution

EUROPEAN LABORATORY FOR PARTICLE PHYSICS LABORATOIRE EUROPEEN POUR LA PHYSIQUE DES PARTICULES

NGSS Data Consolidator (DC)

Cisco Network Switches Juniper Firewall Clusters

How To Build A Network For Storage Area Network (San)

SYNCHRONIZE DIGITAL CLOCK SYSTEM NETWORK DIGITAL CLOCK VER 1.0 DYNATEK

Product Information D23m Digital I/O System

MAJORSINE Power Inverter

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:

CUBE. Subsea Attitude Monitoring and Logging System

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

24 GHz Point-to-Point 1.4+ Gbps Radio. Datasheet. Model: AF24. High Performance Wireless Backhaul. Long Range of 13+ km

At the bottom of the screen you will also see some of our sister brands, all of which can also plug in to the Storm data logger.

Executive Summary. Technical Description

WANic 800 & or 2 HSSI ports Up to 52 Mbps/port. WANic 850 & or 2 T3 or E3 ports Full-speed CSU/DSU. WANic 880.

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

2G-1.1.0, 200M-2.0.3, 200M-1.0.1

A Measurement of 3-D Water Velocity Components During ROV Tether Simulations in a Test Tank Using Hydroacoustic Doppler Velocimeter

Subsea High Bandwidth Data Transfer Using Fiber Optic Technologies

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

IPv6 Broadband Access Network Systems

Datasheet. Managed PoE+ Gigabit Switches with SFP. Models: US W, US W, US W, US W

INTRODUCTION TO MEDIA CONVERSION

Future grid infrastructure Field tests of LVDC distribution

Multiplexing. Multiplexing is the set of techniques that allows the simultaneous transmission of multiple signals across a single physical medium.

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

NetScanner System. Toronto: , Montreal: , Toll Free: ,

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Cisco TelePresence MSE 8000

Power Feeding Equipment for Optical Submarine Cable Systems

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Technical Description U00980 Revision 2

SFP-TX 1000BASE-T SFP Transceiver 10/100/1000M SFP Transceiver

Instruction Manual RT-94845SL RR-94845SL Forty-Eight Channel Video Multiplexer With Bi-directional Ethernet Data

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

SCADA and Monitoring for Solar Energy Plant

PowerGem Pro Uninterruptible Power Supply

Server Technology, Inc.

Figure 1.Block diagram of inventory management system using Proximity sensors.

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

NXU RoIP Link to Eliminate Voice-Grade Leased Line

Impact of Power-over-Ethernet (PoE) on Industrial-based Networking

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

NETWORK ENABLED EQUIPMENT MONITOR

Hybrid-Cable-System with an Advanced Data and Power Architecture Product Brief

TereScope Management Options

Stratix Industrial Networks Infrastructure At-A-Glance

Cisco SFP Optics for Gigabit Ethernet Applications

Chapter 4 Connecting to the Internet through an ISP

Broadband 101: Installation and Testing

NDBC s Smart Module Applications

Submarine Optical Cables as a Key Component in Undersea Telecommunications: A Review

Line Monitoring and Control in Subsea Networks

Introduction Media converters

EtherDevice Switch EDS-726 Series

Ixia Net Optics 10G Regen Tap

Cisco Unified IP Conference Phone 8831 Installation

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

Power & Environmental Monitoring

1.44 kw Programmable DC Power Supplies XLN Series

Networks. The two main network types are: Peer networks

Contents. 1. PROFILE p2. 2. SERVICES 2.1 Offshore Support Services p 4 Offshore support p 6 ROV operations p 8

OIL PRESS 71.8 PSI FUEL. Cloud based, diagnostic, engine monitoring and reporting system.

Cisco SFS 7000P InfiniBand Server Switch

HARTING mcon 1000 Introduction and features

Reverse Powering Its Benefits and Constraints Daniel Feldman VP Business Development, Microsemi. Power Matters

Transcription:

A New Open Cabled Infrastructure in Medsea P.Leon, JF.Drogou, D.Chenot, C.Leveque, H.Martinossi, A.Massol, V.Rigaud, D.Santarelli, P.Valdy IFREMER France C.Gojak, K.Bernardet, Z.Hafidi, Y.Lenault, K.Mahiouz DT-INSU France A.Deschamps, Y.Hello Geosciences Azur France D.Lefevre, C.Tamburini CNRS-COM-LMGEM France JJ.Destelle CPPM France Abstract Recently the ANTARES Neutrino telescope s Infrastructure in the deep Mediterranean Sea, has been extended by a Secondary Junction Box. The main emphasis has been to provide basic power and communications capability for new scientific cabled observatories. This new infrastructure provides unprecedented amounts of power and two-way bandwidth to access and control instrument networks in the oceans. This new development allows cabled observatory to connect the seafloor to the Internet via real-time, two-way highspeed communications. This design gives researchers new capabilities beyond the reach of traditional oceanography. Ocean scientists can run deep-water experiments from labs and universities anywhere around the world. Three different underwater observatories are already been connected at this Secondary Junction Box. This paper presents this new Infrastructure which has been deployed by the R/V Pourquoi Pas? and connected by the IFREMER s ROV VICTOR6000. After a technical description of the system, we detailled an overview of the complete deployment at sea. I. INTRODUCTION Traditionally, ocean scientists have relied on infrequent ship cruises or space-based satellites to carry out their research. Underwater cabled networks and the ocean observatories offer now a new and exciting approach to ocean science. Recently the ANTARES Neutrino telescope s Infrastructure in the deep Mediterranean Sea, has been extended by a Secondary Junction Box (BJS) (Fig.1). The main emphasis has been to provide basic power and communications capability at new scientific cabled observatories. IFREMER, in partnership with CNRS Centre de Physique des Particules de Marseille (CPPM), Geosciences Azur laboratory and l INSU, also with the initial funding provided by the Provence Alpes Cote d Azur (PACA) French region, has developed a Secondary Junction Box. The idea is to take the opportunity of the ANTARES site infrastructure to install this BJS, to provide additional connections for deep sea experimentations. This BJS has been connected in November 2010, by 2500m water depth, through a 400m electro-optical interlink at the main Antares junction box, which is located at 2500m deep in the Mediterranean Sea, 42 km offshore from Toulon (France). The shore station is installed in the control room at La Seyne sur mer (France) (Fig.2). Figure 1. ANTARES Site location BJS Figure 2. BJS and ANTARES Telescope overview

This new junction Box will focus on providing research and development services to two primary sectors: Underwater engineering research, including the development of innovative ocean technologies, such as: new concept of deep sea sensor network (project DEEPSEANET) built from fiber optic micro cable and battery operated IP access mode, new economic wet-mateable economic connector design, new high accuracy synchronisation system. Interdisciplinaries Marine sciences; it provides a facility for marine scientist to design and test unique instrumentation, particularly for application on cabled ocean observatories; this include experiments in the area of studies of active seismic regions, acoustics for cetacean monitoring. Module) developed by the DT-INSU. This MII is directly connected on shore with scientific sensors. 500VAC 4 fibers 1.2 kw 400m BJ Antares BJS fiber 400VDC 100BT Cu 1kW 400VDC Fiber 1kW MII Seismometer Low Voltage DC 485/422/232 100 BT Cu Main cable New telescope technology II. BJS SYSTEM OVERVIEW The submarine cable, which connects the ANTARES neutrino telescope to the shore, is a conventional telecommunication cable. This 42km long cable is equipped with 48 single-mode fibers and one conductor. Power is delivered from shore in AC at 3700V, the sea water providing the return path for the current. At its undersea end, the cable is terminated by the main junction box which is equipped with 16 wet-mateable connectors and performs the following vital operations: it transforms the power received from the shore down to 500VAC, by means of 16 independent secondaries, individually protected by breakers. It splits the fibers of the cable coming from shore so as to serve the different lines of the telescope DeepSeaNet Figure 3. BJS system overview Wet-mateable connector No Wet-mateable connector All the BJS has been designed with the requirement for a high level of reliability and for a 20 years life expectancy. Although the concept is simple, the physical system is much more complex. All the BJS electronic is integrated in a specific titanium housing 350 mm diameter and 1400 mm length (an old one reused for this application), the output connectors have been integrated on the cylinder three on each side. Each wet-mateable connector of the main junction box delivers 4 single mode fibers and 500VAC on 2 electrical conductors. The BJS is connected on one of this wet-mateable ODI connector. The main aim of the BJS is to provide internet communication interfaces between the scientific equipment and shore. This equipment offers 7 wet-mateable ports for the users, allowing the transmit of data and the power supply for the scientific equipments connected. One is a new Ifremer design of economic optical expanded beam connector and is used to connect by means of only one single mode fiber, the first node of the new network DeepSeaNet prototype. Three ODI connectors deliver 100Mb/s on Cu, and VDSL2 for extended long range applications. Another one is a specific Ifremer design wet-mateable connector called CDC and is used for delivering 100Mb/s on Cu. Two ODI optical connectors are integrated for transmit data and clock on two optical fibers. On principle, the BJS delivers 1kW, only 400VDC on its wet-mateable outputs and Ethernet 100Mb/s. The low voltage power supplies (48V,12V or 5VDC) for scientific sensors and RS232, RS422 or RS485 are generated on the scientific instrumentation modules as the MII (Interface Instrumentation Figure 4. BJS Electronic Integration All the design and integration have been achieved by Ifremer at La Seyne s/mer (Fig.4). III. POWER GENERATION

The main design features of BJS power system are to provide 400VDC with 1kW full power. It is also to insure a total protection of the power supply input, whatever fault is present on the output. This scientific and technology test bed must be completely transparent for the Antares telescope. This requirement means a high accuracy of monitoring of the current delivers and of the leakage and ground faults detection on the outputs. This means also, that the power system has to be autonomous with enough intelligence to be able to switch off in very short time (and always faster than the Antares BJ breakers), all the individually outputs and in generally all the power generation circuits. 1.25 Gb/s CWDM Tx/Rx mux/demux CWDM λ1 λ2 BJS Data transmission 48V Controller Console Link λ4 E/O conversion Switch Ethernet 100 Mbits/s 3 λ3 Vdsl2 For that purpose, 3 current hall sensors, which react straightly on the regulation interrupter, have been integrated. At the a complete redundancy and increasing the reliability. This equipment provides eight 100Mb/s full duplex Ethernet. Cu FO Figure 6. Data transmission Figure 5. Power generation overview input, a rectifier bridge built with diodes and triacs, allows a controlled slow slope on the input filter capacitor. That principle reduces the inrush current when closing the switches, thus eliminating the need for current limiting resistances at startup. Generally the power supply has been designed for a very compact sizing, compatible with the integration in the housing. This design is very compact and allows 75% efficiency for all AC/DC conversion (Fig.5). Four ports are directly wired on the output connectors. One link is dedicated to the controller embedded in the BJS. Three are used by VDSL2 modem, for extending the distance with scientific instrumentation, with of course lower data rate. The embedded IE3000 Cisco switch, with its compact size, its 24V power supply, and its ability to transmit very accurate Precise Time Protocol (PTP, IEEE1453) is particularly well adapted for this application (Fig.6). The controller, based on ARM with a light embedded Linux, controls in complete autonomy all the system. It is always powered and can restart on alarm, the switch and the power generation. This equipment can be control on surface by a single navigator connected to the embedded web browser (Fig.7). The surface operator can check in real time all the data (as currents, voltages, state of outputs) and command the start-up of the regulation and the switching of each output individually, every second. IV. DATA TRANSMISSION Only one 9/125μm single-mode fiber is used for the bidirectional data transmission. This network is mainly composed of passive devices for maximum reliability. Among the 4 optical fibers deliver on the connectors, two are dedicated to Antares master clock for the future experiment of a km3- scale apparatus. Another one is dedicated to DeepSeaNet node. A Coarse Wavelength Division Multiplexing (CWDM) system is used for data transmission in order to merge several 100Mb/s Ethernet on a single optical fiber, using different laser wavelengths. Passive CWDM filter distribute 8 λ CWDM from 1470 ηm to 1610 ηm. Four are used by the Ethernet switch for Figure 7. Real Time Control Interface

All the control data refreshed every second, are logged on SD card and are accessible immediately on the web interface. On shore station, the network architecture is completely symmetrical, concerning the switch and the passive CWDM filter. A set of PCs run the applications of the scientific sensors. A server route the BJS data network on the IP public network. By this way, every scientist can have access to all the sea sensors data, in real time in the lab. Users will be able to access the system from anywhere in the world and interact with their instruments as if it were on their work bench. One of the key requirements is that users can interact with their instrument using their own software without any major configuration changes. To enable this, each instrument attached to the BJS is on its own virtual LAN. The user will be provided with an account for accessing the system, which will allow them to access their instrument as if it were locally, connected (Fig.8). The first Deep Sea Net IP-node has been deployed during the TEXREX cruise on a dedicated fiber through the BJS (Fig.9). This node is connected to the shore node by a 42km single optical fiber. The optical wake-up principle and the new economic wet-mateable connector have been validated. This network, easy to install can be deployed by non specialized sea-operating company, providing IP connection every 40 km. Each node is equipped with batteries and wet-mateable connectors for geophysic sensors, but could be open to other sensors (Fig.10). All the system is now fully operational and others segments of 40km will be deployed during the next ROV Victor6000 operation. IP Public Network Scientific Network local network BJS Gateway Switch Surface CWDM Filter Scientific Network PC BJS CWDM Filter Contrôleur BJS Figure 10. Deepseanet First Node Bottom Switch Figure 8. Shore station network architecture Scientific applications V. DEEPSEANET PROTOTYPE. Deep Sea Net is a new concept of a deep sea sensor network built from one optic fiber micro cable and battery operated IP access nodes. This innovative approach permits to build extend and maintain future sensor networks at very competitive prices. VI. DEPLOYMENT OF THE INFRASTRUCTURE AT SEA For the deployment of the BJS electronic titanium housing, an heavy sled has been built, which is laid down on the seabed. On this sled, two platforms have been mounted on each side, allowing the ROV Victor 6000 to stay stable, during the connexions operations, with the two manipulator arms. For guiding the wet-mateable plugs, guide systems have been installed around each wet-mateable connectors. The BJS has been designed as recoverable module and is locked up on the sled with a prism case. (Fig.11) Figure 9. Deep Sea Net topography Figure 11. sled overview

The BJS has been deployed during the TEXREX cruise in November 2010 on the Research Vessel PourquoiPas?, with the Ifremer ROV Victor6000. After navigating by fixes from a network of sea-bed acoustic transponders deployed around the ANTARES site, and then staying in place with its GPS dynamical positioning system, the R/V PourquoiPas? has deployed electro-optical interlink and equipments. direction, pressure, oxygen concentration and a camera for measuring bioluminescence on the site (Fig.14). Figure 14. MII module Figure 12. Deployement and connection of the BJS All the deployment to seabed and positioning over site need to operate with adequate accuracy. The whole BJS system, including scientific modules, has been laid down on the bottom with cable, flotation and acoustic release system. Underwater interlink cables are used for connecting the BJS to the main Antares junction box and to the scientific equipments MII and seismometer (Fig.12). The installation and the connection of these cables is made by means of the Victor 6000 (Fif.13). Figure 15. Seismometer module A multiparameter seismometer module for sea floor motion observation proposed by Geosciences Azur and integrated by Guralp System has been also connected on the BJS to respond to both operational and scientific goals (Fig.15). The module is composed of a very broad band (0.0028 at 50Hz) seismometer, an accelerometer, 2 tiltmeters, a differential pressure gauge and an absolute pressure sensor Paroscientific. A bell was placed over the seismometer to prevent noise from bottom currents. Few days after the connection, on 9th November, the instrument recorded an uncommon magnitude 4 seismic event between Toulon and Corsica; the available data contributed to a better location of this event (Fig.16). Figure 13. BJS at 2500m depth VII. SCIENTIFIC RESULTS During the same Texrex cruise different scientific modules have been connected to the BJS on the sea bed at 2500m, and are now delivering real time data. Generic oceanographic sensors have been deployed on the MII (developed by DT- INSU) for monitoring in real time of key oceanographic parameters as: temperature, salinity, current velocity and Figure 16. Seismometer data

VIII. CONCLUSION This new infrastructure has been developed in a very short time by IFREMER, in partnership with DT-INSU, CPPM and Geosciences Azur. It has been deployed at 2500m in the Mediterranean Sea in November 2010 and is now fully operational, with scientific modules already connected, providing real time data. This new infrastructure installed on the ANTARES site presents all the capabilities for European demonstration mission with real time data acquisition, in order to test new developed instruments and observatory technologies ACKNOWLEDGMENT We thank all the technical teams in IFREMER, DT-INSU, Geosciences Azur and CPPM, which have worked on this project. We thank OSEAN Technology for their work on the controller of the BJS. We thank D.Poizac (BTS electrotechnical Lycée Rouvière) for his advices and his work on the power system We thank also the crew of the R/V Pourquoi Pas? and the ROV team of Victor6000 for their skill and support at sea during the TEXREX cruise. REFERENCES [1] P.Valdy, V.Ciausu, P.Leon, P.Moriconi, V.Rigaud, Y.Hello, P.Charvis, A.Deschamps Deep Sea Net: an affordable and expandable solution for deep sea sensor network OCEANS 2007. [2] D.Lefevre Sea&Earth Sciences around Antares poster ESONET, december 2010 [3] I.Puillat, R.Person, C.Leveque, JF.Drogou, M.Diepenbroek, P.Garreau, C.Waldmann, Y.Auffret Standardisation prospective in Esonet NoE and a possible implementation on the ANTARES Site Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, detectors ans Associated Equipment, Vol 602, 2009,pp 240-245 [4] R.Person, P.Favali, C.Barnes, Y.Kaneda, J.Delaney, S.Hsu Seafloor Observatory Science OceanObs 2009