This chapter discusses Synchronous Data Link Control (SDLC) protocols that you can configure on a BANDIT device s ports. See the following sections:



Similar documents
! encor en etworks TM

Section 11.1, Simple Network Management Protocol. Section 11.2, Port Data Capture

The BANDIT Device in the Network

enetworks TM IP Quality of Service B.1 Overview of IP Prioritization

Configuring a BANDIT Product for Virtual Private Networks

WANPIPE TM. Multi-protocol WANPIPE Driver CONFIGURATION M A N U A L. Author: Nenad Corbic/Alex Feldman

enetworks TM BANDIT, C2C, and VSR-1200 Document Set List of Groups and Modules

WAN Data Link Protocols

enetworks TM Using the Syslog Feature C.1 Configuring the Syslog Feature

Chapter 2 - The TCP/IP and OSI Networking Models

his document discusses implementation of dynamic mobile network routing (DMNR) in the EN-4000.

! encor e networks TM

! encor e networks TM

Introduction to WAN Technologies

Introduction to WAN Technologies

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

Configuring SNA Frame Relay Access Support

Remote Access Server - Dial-Out User s Guide

Legacy vs. IP Version Software 2. Getting Familiar with thesystem

SYNC MAX PCI Adapter

High-Level Data Link Control

PPP encapsulation has been carefully designed to retain compatibility with most commonly used supporting hardware. PPP encapsulates data frames for

Notes Odom, Chapter 4 Flashcards Set:

Designing SDLC, SDLLC, and QLLC Internetworks

How to establish a Leased Line Connection

How To Set Up A Netvanta For A Pc Or Ipad (Netvanta) With A Network Card (Netvina) With An Ipa (Net Vanta) And A Ppl (Netvi) (Netva)

Quectel Cellular Engine

WANs connect remote sites. Connection requirements vary depending on user requirements, cost, and availability.

Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

Service Managed Gateway TM. How to Configure a T1/E1 Connection

Frame Relay and Frame-Based ATM: A Comparison of Technologies

PPP (Point-to-Point Protocol)


Vanguard Managed Solutions

VisorALARM-Manager Application Quick Guide. (Ver. 1.3) Dm 380-I. V:3.0

Issue 1 EN. Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

The BANDIT Products in Virtual Private Networks

DLSw+ Enhanced Load Balancing

Computer Networks. Definition of LAN. Connection of Network. Key Points of LAN. Lecture 06 Connecting Networks

AT&T Managed IP Network Service (MIPNS) MPLS Private Network Transport Technical Configuration Guide Version 1.0

WAN Leased Lines NetPerformer System Reference

Chapter 4 T1 Interface Card

Migrating a Legacy WAN to TCP/IP Infrastructure

How To. Configure E1 links. Introduction. What information will you find in this document?

Nokia E61i Configuring connection settings

Configuring a VPN for Dynamic IP Address Connections

Here is the ed analysis conversation between the customer s support team and Applied Methodologies.

WAN Technology. Heng Sovannarith

WAN Technologies Based on CCNA 4 v3.1 Slides Compiled & modified by C. Pham

These highly flexible interface cards facilitate several important applications:

Vanguard Managed Solutions

Configuring T1 and E1 WAN Interfaces

Data Link Protocols. TCP/IP Suite and OSI Reference Model

1 Getting Started. Before you can connect to a network

DSL-2600U. User Manual V 1.0

NetVanta Series (with Octal T1/E1 Wide Module)

Figure 1 - T1/E1 Internet Access

SRX 210 Services Gateway T1 Interface Configuration

A Brief Overview of SONET Technology

Leased Line + Remote Dial-in connectivity

2. IP Networks, IP Hosts and IP Ports

Exam 1 Review Questions

2. What is the maximum value of each octet in an IP address? A. 28 B. 255 C. 256 D. None of the above

White Paper: Voice Over IP Networks

This course has been retired. View the schedule of current <a href=

Cisco Configuring Basic MPLS Using OSPF

Octal T1-10/100 RIOP Installation Guide

TSX ETY 110 Module 8

Link Layer Discovery Protocol

Configuring Serial Interfaces

PBX Q-SIG Networking, Access to a Frame Relay Network

CCNA R&S: Introduction to Networks. Chapter 5: Ethernet

Issue 2EN. Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

BLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE

NetVanta 3000 Series (with T1/FT1 or T1/FT1 with DSX-1 Network Interface Module)

! encor e networks TM

This document explains how to use your Web Browser to configure the 100BaseT IOPRINT+ Print Server models. Connecting to the IOPRINT+ Print Server

This document explains how to use your Web Browser to configure the 100BaseT Print Server models

Talk2M ewon Internet Connection How To

Configuring connection settings

Smart Solutions for Network IP Migration

Introduction to Wide Area Network Protocols

TCP/IP Network Connectivity and ION Meters

SMC7004ABR Barricade Broadband Router Installation Instructions

GlobalSCAPE DMZ Gateway, v1. User Guide

CONTROL MICROSYSTEMS DNP3. User and Reference Manual

MN-700 Base Station Configuration Guide

Appendix A QUICK Specifications

High Performance VPN Solutions Over Satellite Networks

A More Secure and Cost-Effective Replacement for Modems

Software User Guide UG-461

Network administrators must be aware that delay exists, and then design their network to bring end-to-end delay within acceptable limits.

CORPORATE NETWORKING

Contents Introduction Why Fax over IP? How Real-time Fax over IP works Implementation with MessagePlus/Open Summary. About this document

IP Addressing and Subnetting. 2002, Cisco Systems, Inc. All rights reserved.

Load Balancing ContentKeeper With RadWare

Tech Note Cisco IOS SNMP Traps Supported and How to Conf

VPN over Satellite A comparison of approaches by Richard McKinney and Russell Lambert

User's Guide bintec R4100 / R4300 Serial Unit. Copyright July 17, 2006 Funkwerk Enterprise Communications GmbH Version 0.9

Installation & Configuration Manuel. Socket Server. OpenAT application

Transcription:

encor! enetworks TM Version A, September 2010 2010 Encore Networks, Inc. All rights reserved. SDLC Protocol Configuration This chapter discusses Synchronous Data Link Control (SDLC) protocols that you can configure on a BANDIT device s ports. See the following sections: Section 4.1, SDLC with IP Section 4.2, SDLC 1490 Configuration Section 4.3, SDLC Routing Note: See the Protocols Module for a full list of protocols. 4.1 SDLC with IP To provide support for legacy networks in banking, manufacturing, and other businesses, the BANDIT products can use SDLC-to-IP protocol conversion or transport. This is a cost-effective solution for upgrading legacy SDLC networks to IP; it provides a more immediate upgrade at a lower cost than does replacement of legacy products. There are two ways to use SDLC with IP: SDLC over IP Transport SDLC to IP Conversion 4.1.1 SDLC over IP Transport In the SDLC network, the mainframe uses a front-end processor (FEP) to talk with the remote terminals. The BANDIT sits between the FEP and the IP network. The BANDIT device receives SDLC transmissions from the FEP and spoofs the response that is, the BANDIT responds to the FEP as if the BANDIT were the remote SDLC device. Then the BANDIT encapsulates SDLC within IP packets, and sends the transmission to the remote device (Figure 4-1). For information on trademarks, safety, limitations of liability, and similar topics, see Notices. Home Module: Protocols Document 4

Page 2 Protocols Module, Document 4 Figure 4-1. SDLC over IP Transport On the remote end, a BANDIT device receives the transmission, removes the IP packets surrounding SDLC, and sends the SDLC transmission to the remote SDLC device. (The BANDIT on the remote side is spoofing the SDLC devices by polling them as if it were the FEP.) Note: In the legacy SDLC network, the connection between the FEP and the remote SDLC devices was over leased lines. In this setup, the connection is over the public internet or a private IP network. There is a BANDIT, acting as an IP gateway router, at each end. 4.1.2 SDLC to IP Conversion There is no front-end processor. The network mainframe sends IP packets (through an IP router) to the remote end of the network. In this setting, there is no SDLC on the host network only IP (Figure 4-2). Figure 4-2. SDLC to IP Conversion A BANDIT is the IP router on the remote end, spoofing the SDLC devices. The BANDIT receives the IP packets from the mainframe, converts IP to SDLC, and sends the SDLC transmissions to the SDLC devices. In reverse, the BANDIT receives SDLC from the devices, converts SDLC to IP, and sends the IP packets to the mainframe.

SDLC Protocol Configuration Page 3 Note: Non-use of a front-end processor is called NCP bypass (Network Control Protocol bypass). 4.1.3 Configuring SDLC with IP Perform the following steps to configure the BANDIT device for SDLC with IP: 1 Set up a serial port or a CSU/DSU T1/E1 port to carry the SDLC 1490 protocol. See Section 4.2, SDLC 1490 Configuration. 2 Set up a path for data entering this port to reach the remote IP host. (The path will also be used in the reverse direction, for data from the remote IP host to reach the SDLC device.) See Section 4.3, Defining Global Paths. 3 SDLC is secure because the lines are private. IP travels over the public internet. To set up secure transmissions, IP uses VPN tunnels. See The BANDIT Products in Virtual Private Networks, to set up a VPN tunnel for the connection over the public internet. 4.2 SDLC 1490 Configuration SDLC 1490 configuration provides connectivity between SDLC devices in conformance with the IBM recommended SDLC protocol standards. SNA devices comprise the following: IBM SNA host, terminals, routers, and bridges IBM SNA-compatible hosts, terminals, routers, and bridges You can use the SDLC 1490 COnfiguration option to make the following connections: Local SDLC Terminal to Remote SDLC/Frame Relay host, as shown in Figure 4-3 (A host is typically an IBM-compatible 3745 or an AS400.) Local SDLC host to Remote SDLC/Frame Relay terminal, as shown in Figure 4-4

Page 4 Protocols Module, Document 4 Unit Host Frame Relay Host Unit Unit Host Figure 4-3. Local SDLC Connected to Remote SDLC/Frame Relay Hosts SNA Host Unit Unit 1 SNA Host IBM Router SNA Host Unit Figure 4-4. Local SDLC Host Connected to Remote SDLC

SDLC Protocol Configuration Page 5 How to Configure SDLC 1490 Note: You must complete the SNA Routing Table with the addresses of all units in your network. (See Section 6.1, SNA Routing for 1490.) Also see Section A.2.9, SDLC 1490 Configuration Statistics. 1 From the Main Menu, select Advanced Configurations, Data Configurations, and select a serial port or a CSU/DSU T1/E1 port. Then select Undefine Logical Protocol. Finally, select Protocol, SDLC 1490 Configuration. When you select SDLC 1490 Configuration (E) from the Logical Port Protocol Selection menu, the following menu is displayed: SDLC 1490 Config Parameters : ------------------------------- 1) Speed : 9600 2) Polling Emulation Type : TERMINAL 3) Data Format : NRZ 4) Idle Character : FLAG 5) DCD : FORCED 6) User Buffers HWM : 18 7) User Buffers LWM : 12 8) SDLC 1490 s Enter Choice : 2 Select Speed. This option allows you to set the synchronous clock speed that units configured as DCE will use to provide clocking to the user s equipment. The following menu will be displayed. Configure Synchronous Clock Speed ---------------------------------- 1) 2400 2) 4800 3) 9600 4) 19200 5) 38400 6) 48000 7) 56000 8) 64000 9) 96000 A) 128000 B) 192000 C) 256000 D) 384000 E) 512000 F) 768000 G) 1024000 H) 1536000 I) 2048000 J) External(DTE) Enter Choice :

Page 6 Protocols Module, Document 4 Note: This menu reflects that, when this port is DTE, the speed is provided by the external device connected to the port. 3 Polling Emulation Type. This option allows you to specify whether the unit port is connected to a terminal or to a host. Select Polling Emulation Type from the SDLC 1490 Configuration menu. The following menu appears. Configure SDLC2 Type (HOST/TERMINAL) -------------------------------------- 1) Host End 2) Terminal End Enter Choice : a If the unit is connected to a host, select Host End. If the unit is connected to a terminal, select Terminal End. 4 Select Data Format. The following options are displayed: Configure Data Format ------------------------ 1) NRZ 2) NRZI Enter Choice: a Select the data format your host/terminal expects to receive: Non-Return-to-Zero (NRZ) or Non-Return-to-Zero Inverted (NRZI). 5 Select Idle Character. This parameter specifies whether Mark or Flag characters (7E) should be transmitted between frames. The following menu is displayed: Configure Idle Character ------------------------- 1) MARK 2) FLAG Enter Choice: a Select one of the following options: Mark. This option configures the unit to send solid Mark characters (all binary ones) in the idle state, except when the Poll/Final (P/F) bit (bit 0x10 of the second byte of the frame) is clear (off). This exception was explicitly designed for compatibility with IBM AS400s. However, it does not reflect the actual state of an HDLC line over halfduplex modems.

SDLC Protocol Configuration Page 7 Flag. This option configures the unit to send HDLC Flag characters (0x7e with no zero insertion) in the idle state, which is the normal state. 6 Select DCD. This parameter specifies whether Data Carrier Detect (DCD) is FORCED or SWITCHED. The following menu is displayed: Configure DCD -------------------- 1) SWITCHED 2) FORCED Enter Choice: Note: DCD is effective only on ports with DCE interfaces. 7 Select one of the following: Switched. This option allows you to activate DCD only when valid data is sent to the port. Forced. This option allows you to activate DCD at all times. 8 The high-water mark (HWM) and low-water mark (LWM) control the flow of traffic through the SDLC link. For example, suppose traffic is being passed from a high-speed Frame Relay link through an SDLC link. When the buffers in the SDLC link are filled to the level specified in the High Water Mark setting and the SDLC link is in danger of becoming congested, the SDLC link sends a message to the high-speed link, requesting that it slow down the flow of traffic. When the SDLC link has emptied its buffers to the level specified in the Low Water Mark setting, the SDLC link sends another message to the high-speed link, asking it to resume its normal flow. Do the following: a Select High Water Mark. The following prompt is displayed: Enter User Buffer HWM (16 to 31)[18]: b Type the high-water mark buffers you want to use and press Enter. (It is strongly recommended that the default value be used.) c Select Low Water Mark. The following prompt is displayed:

Page 8 Protocols Module, Document 4 Enter User Buffer LWM(10 to 15)[12]: d Type the low-water mark buffers you want to use and press Enter. (It is strongly recommended that the default value be used.) 9 s are the SNA terminal devices with control unit (CU) addresses. To make entries in the controller table, select SDLC 1490 s. The following prompts are displayed: Empty Table Add Table Entry Enter SDLC Address(2 Hex Digits): a Type an SDLC address with two hexadecimal digits and press Enter. The following prompt is displayed: Do you want rest of the parameters to be default?(y/n) b Do one of the following: Select Yes to use default parameters. If you select y, you are given the opportunity to add more SDLC Addresses to the table. The following prompt appears. Repeat Step 9a. Select No. If you select n, the following prompt is displayed: For the following, press <Enter> for default value[xxx] Enter Receive Window Size(1 to 7)[7]: c Receive Window Size. This option reflects the SDLC Sliding Window protocol. Type the Receive window size you want, and press Enter. The following prompt is displayed. Enter Transmit Window Size (1 to 7)[7]:

SDLC Protocol Configuration Page 9 d Transmit Window Size. This option reflects the SDLC protocol transmit window size. Type the size you want to use and press Enter. The following prompt is displayed. Enter Acknowledge Timer T1 (Seconds)(1 to 60)[3]: e Acknowledge Timer T1. This option reflects the amount of time the system waits for acknowledgment of transmitted frames. Type the Acknowledge Timer T1 (time in seconds) and press Enter. The following prompt is displayed: Enter Maximum Retries N2(0 to 60)[5]: f Maximum Retries N2. This option reflects the number of times the system tries to retrieve an acknowledgment. Type the Maximum Retries N2 and press Enter. The unit will display a message confirming that the entry was added and then prompts you for the next SDLC Address. Entry Added Enter SDLC Address (2 Hex Digits): 10 Do one of the following: a Repeat Step 9a. b If you have finished entering SDLC addresses, press Escape to return to the SDLC 1490 Configuration Parameters menu. 4.3 SDLC Routing In addition to Protocol Emulation (Spoofing) and Bit Sync Encapsulation, and SNA 1490, you can configure the unit to support SDLC using SDLC Routing. When a unit port is configured for SDLC Routing, it reads only the addressing portion of the SDLC frame. This is a more efficient method of transmitting SDLC than SNA RFC 1490. The DCD (SWITCHED) and Idle Character (MARK) options are intended primarily for use with half-duplex SNA/SDLC applications, particularly in conjunction with the IBM AS400.

Page 10 Protocols Module, Document 4 LCA = Local Address Configuration for SDLC Routing Unit B Terminal N 1 Frame Relay DLCI 16 LCA = C1 Unit A (Host) 1 DLCI 16 DLCI 17 DLCI 18 DLCI 16 Unit C Terminal N 1 LCA = C2 LCA = C3 LCA = C1, C2 DLCI 16 Unit D Terminal N 1 LCA = C3 Figure 4-5. Sample Network for SDLC Routing How to Configure SDLC Routing Note: Make sure you have configured a Frame Relay port with a matching DLCI. This protocol is proprietary and requires a unit at both ends of the link. Note: See Section A.2.10, SDLC Routing Statistics, for a description of the statistics used to monitor this protocol. 1 From the Main Menu, select Advanced Configurations, Data Configurations, and select a port. Then select Undefine Logical Port, Protocol, SDLC Routing. When you select SDLC Routing from the Logical Port Protocol Selection Menu, the following menu is displayed: SDLC Routing Parameters : SERIAL ----------------------------------- 1) Speed : 9600 2) Data Format : NRZ 3) DCD : FORCED 4) Idle Character : FLAG 5) Routing Entries Enter Choice : 2 Speed. This option allows you to specify a synchronous clock speed for units configured for DCE. Select Speed. The following menu of speeds is displayed.

SDLC Protocol Configuration Page 11 Note: When the port is configured as DTE, as opposed to DCE, the parameters menu reflects that the speed is provided by the device connected to the unit. In this case, you do not need to configure speed. If you attempt to configure the speed, the following message is displayed and you are returned to the parameters menu: Port is DTE, Cannot Change Speed Configure Synchronous Clock Speed ---------------------------------------------------- 1) 2400 2) 4800 3) 9600 4) 19200 5) 38400 6) 48000 7) 56000 8) 64000 9) 96000 A) 128000 B) 192000 C) 256000 D) 384000 E) 512000 F) 768000 G) 1024000 H) 1536000 I) 2048000 Enter Choice: 3 Data Format. This option allows you to specify whether the data format should be Non- Return-to-Zero (NRZ) or Non-Return-to-Zero Inverted (NRZI). Select Data Format. The unit will display the menu below: Configure Data Format ------------------------------- 1) NRZ 2) NRZI Enter Choice: 4 Enter the number of the format your host/terminal expects to receive. 5 DCD. This option allows you to specify whether Data Carrier Detect (DCD) is FORCED or SWITCHED. Select DCD from the SDLC Routing Parameters menu. The unit will display the following menu: Configure DCD --------------------- 1) SWITCHED 2) FORCED Enter Choice:

Page 12 Protocols Module, Document 4 Note: DCD is effective only on ports with DCE interfaces. a Switched. This option allows you to activate DCD only when valid data is sent to the port. If you want to do this, select SWITCHED (1) and the unit will redisplay the SDLC Routing Parameters menu. b Forced. This option allows you to activate DCD at all times. If you want to do this, select FORCED (2) and the unit will redisplay the SDLC Routing Parameters menu. 6 Idle Character. This option allows you to specify whether MARK or FLAG characters (7E) should be transmitted between frames. Select Idle Character. The following menu is displayed: Configure Idle Character --------------------------------- 1) MARK 2) FLAG Enter Choice: a Mark. This option allows you to configure the unit to send solid Mark characters (all binary ones) in the idle state, except when the Poll/Final (P/F) bit (bit 0x10 of the second byte of the frame) is clear (off). If you want to do this, select MARK (1) from the Configure Idle Character menu. This exception was explicitly designed for compatibility with IBM AS400 s. However, it does reflect the actual state of an HDLC line over half-duplex modems. b Flag. This option allows you to configure the unit to send HDLC Flag characters (0x7e with no zero insertion) in the idle state (normal state). If you want to do this, select FLAG from the Configure Idle Character menu and type the number of the option you want. 7 Routing Entries. This option allows you to create a routing table that maps the controller addresses, DLCIs, and ports. Select Routing Entries. The following prompt is displayed: Add SDLC Routing Table Entry Enter SDLC Address: a Type the SDLC Address and press ENTER. The unit will display the following prompt: Enter Path Name (1 to 10 Characters):

SDLC Protocol Configuration Page 13 b Path Name. This option allows you to identify the Global Path entry that corresponds to the path this traffic will take through the network. You do this by entering the name you assigned to the Global Path. A global path entry contains information such as port numbers, path types, channel numbers, DLCIs, and X.121 addresses. This option is accessed from the Main Menu. Select GPT Name. The following prompt is displayed: Enter GPT Name: c Enter the Global Path Name and press Enter. If you enter a name that is not already associated with a Global Path, you are prompted to enter the path now: Path Name Does Not Exist In GPT Table. To Add Global Path Entry, Press "Y". Press Escape Otherwise. d Press Enter or type Y. The unit will display the following menu: Global Path Types ------------------ 1) X25 SVC 2) X25 PVC 3) Frame Relay PVC 4) Port Type 5) IP/UDP 6) Voice Enter Choice : (1 to 6)[1] : Note: You cannot save this configuration if a valid GPT Name has not been entered. e Press ESC to view the table of entries you have made. You can add, delete, or change the entries as necessary. When you have finished making changes, press ESC four times to return to the Main Menu.

Page 14 Protocols Module, Document 4