Experience Our Innovation

Similar documents
WARRANTY BOOKLET. Commercial Water Heaters. Register online at

Endless Hot Water 24/7

WARRANTY BOOKLET. Continuous Flow Water Heaters. Register online at

Continuous Flow Water Heaters

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

Get more from your hot water

CONTINUOUS FLOW HOT WATER

NOW 6 STAR EFFICIENT. factor RHEEM CONTINUOUS FLOW GAS HOT WATER HOT WATER THAT NEVER RUNS OUT YEAR WARRANTY L/MIN ENERGY GAS

Hot Water Decisions Guide

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

WATER INDUSTRY ACT South Australian Water Heater Installation Requirements. Prepared by the Technical Regulator

Session 2: Hot Water Supply

Integrated Solar Radiant Systems

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Hot Water South Australia

ASPE Seminar Water Heater Piping Strategies. Presented by Joe Kalarickal, EIT Regional Sales Manager AERCO International

HEAVY DUTY STORAGE GAS

Continuous flow direct water heating for potable hot water

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Why worry about your hot water system?

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Home comfort: water heating

Solar hot water systems that give energy efficiency a whole new meaning

Energy saving tips for home

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

Heating and cooling a home in Australia amounts to around

Natural geothermal energy.

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Typical condensing boilers can have an efficiency rating of 89% and up, which is 25% more efficient than a non-condensing boiler.

Codes and High Performance Hot Water Systems. Gary Klein Affiliated International Management, LLC

Hot Water. Heat pump water heaters. Residential and Commercial R410a

SOLAR HOT WATER SOLUTIONS stainless steel roof systems

Energy Efficiency HOSPITALITY.

HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

SOLAR HEATING SYSTEMS.

Electric Flow Boiler

HEATING, VENTILATION & AIR CONDITIONING

WC flushing cistern single or dual flush to fill in 2 minutes WC trough cistern 0.15 per WC Wash basin tap size 1 2

Combi Unit Genius. The energy efficient Building Service Centre

HOT WATER SYSTEMS.

HSQ. Heuston South Quarter Community Heating System User Guide

Energy Efficiency Evaluation Reportii House file number: 9900D00001ii

Link-Up. Solid Fuel Association Guide to Central Heating.

Apartment and Communal Heating Solutions

RHEEM DOMESTIC HOT WATER

your water pressure explained

GAS CONVERSION PROJECT ˆAn Alternative to Oil

Water Heating and Heat Recovery 1

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

CHAPTER 9: WATER HEATING

Itho Products for Hot and Boiling water. product-

SEERS International. Hybrid Hot Water Systems. Innovation Technology

Hot water supply, distribution and use

Winter heating This winter heating guide includes ways to reduce heating costs and provides advice on choosing the right heater to suit your needs.

How to choose a heat pump and use it wisely

Sizing and Selection of Hot Water Generating Plant. Presentation by: Rob Larner & David Dutch

Vaillant s plain English guide to. simple, concise and precise

REFERENCE GUIDE. Hot Water. Experience Our Innovation

WATER. Water Management Protect your building from water damage. Intent. Information & Tips

High-efficient gas boiler CompactGas

GAS HEATING IN COMMERCIAL PREMISES

Solar Hot Water. What systems are available?

ROTEX gas hybrid heat pump. A strong team.

Air Conditioner Water Heater Model ACWH18

Solar Hot Water Heaters

Daikin Altherma Hybrid Heat Pump

Delivering exceptional performance and Ecovalue. Ecocent

Daikin Altherma Hybrid Heat Pump

SPIDERfire: Delivers high efficiency and real savings for today s businesses

Home Energy Efficiency and Conservation: Call to Action. July 23, 2015 Dave Blake and David Wood REEP Green Solutions

First Time Home Buyers Energy Efficiency Workshop Guide

Daikin Altherma Hybrid Heat Pump

SECTION Hot Water Heaters (Hot Water Recirculation Systems and Point-of-Use Water Heaters)

Owner s Manual. Installation Details Owner s Information. 80L to 400L Electric Storage Water Heaters

Technical & Specification Information Bosch 32 Series Water Heaters. Bosch Commercial Series Condensing & Non-Condensing Continuous Flow Water Heaters

UNDERSTANDING CENTRAL HEATING SYSTEMS

Tankless Water Heater A Primer for Contractors, Installers, Builders and Homeowners

Origin s. We ll manage the bulk of your hot water

Greenhouse Gas Implications of HVAC Upgrades in Multi-Unit Residential Buildings

Response: The combi boiler. Response: The fit anywhere combi

Do your own home energy audit

FilterFlow Automatic Water Boilers. Pure Quality

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

Vitocaldens 222-F Compact Gas-Hybrid appliance

ALFEA HYBRID DUO GAZ. New Model 2011

FILLING AND PURGING THE SYSTEM

CASH SAVING BEATS ECO CONCERNS AS MAIN REASON TO GREEN YOUR HOME

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL

FREQUENTLY ASKED QUESTIONS (SOLAR WATER HEATER)

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60

Aquamax Australia Pty Ltd ABN

Commercial Hot Water. Make a difference...

Energy'Saving,'Thermal'Comfort'and'Solar'Power'Information'Sheet'

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Transcription:

Experience Our Innovation Rinnai Holdings (Pacific) Pte Ltd 47 Tannery Lane #05-01/02 Elite Industrial Buiding II Singapore 347794 T. +65 6748 9011 F. +65 6745 9240 E. Solution@rinnai.sg www.rinnai.sg EXPERIENCE OUR INNOVATION

About Us Helping create a sustainable society as a comprehensive heat-energy appliance manufacturer through measures focusing on the environment, comfort, and safety and peace of mind. Fast and Continuous hot water supply/ Fast recovery rate Structural Loading Space Saving Rinnai Water Heating System Advantages Direct fired heat exchanger means instantaneous water heating with unlimited supply of hot water on demand. This system significantly reduces the load on the structure which will translate to lower cost in reinforcing the concrete and steel structure. Wall mounted heater help save more space and only require a very small footprint. The extra room space from the original system can be give up for other services and equipment. Rinnai Water Heating System Advantages Bringing more convenience, comfort, and peace of mind to people s lifestyles through gas appliances. That is what interfaces between heat and lifestyles is all about. Rinnai has been dedicated to this concept since its founding in 1920. Our aim is to continue providing prosperity to everyday lives through the singular energy source of gas as an industry leader that constantly strives to meet global needs. Rinnai creates and supplies optimum gas appliances for today, tomorrow, and the future. In order to help realize a sustainable society and sustainable planet, Rinnai focuses on the environment, comfort, and safety and peace of mind in its creation and supply of optimum heating appliances. Electrical Saving Smaller Hot Water storage Flexibility for future expansion Smooth operation Servicing & Maintenance There is huge cut down in electrical power consumption by transferring the heating energy to gas (Clean energy). Lower storage required due to higher efficient On Demand system. Lesser energy required to maintain the capacity of hot water stored. Easy modification by adding extra gas heaters if higher capacity is required for future expansion. Hot water supply is not interrupted by break down of individual heater due to the multiple module installation. Only quarterly inspection for cleaning of gas heater filters and priming of pump is required. Low maintenance of system helps to cut down labour cost. 02 03

05Manifold Packs Manifold Packs 04 MANIFOLD PACKS What is a Rinnai Manifold Pack? A Rinnai Manifold Pack consists No. of. Infinity continuous flow water heaters plumbed together to allow higher flow rates than a single unit can provide. What are the key features? Outlet temperature is preset and remains constant, even when the flow varies Peak flow rate cannot be exceeded No flow = no gas consumption No wasteful pilot lights Usually used for dead leg type installations, however ringmain pumps can be fitted if required* *Continuous flow water heaters used on flow and return ringmain systems must have correct pipe and pump selection. For further information, please contact your Rinnai Commercial Representative. What are some suitable applications? Applications include (with suggested temperatures): Sporting Club Change Rooms - temperature set at 42 C or 50 C Shower Blocks in Caravan Parks - temperature set at 42 C or 50 C Cafés, Restaurants and Pubs - temperatures set at 65 C Hot Water Hoses and Manufacturing Processes - temperature set at 75 C or 85 C What will the SYSTEM offer your application? Energy savings, as there are no tank heat losses, pilot lights and the system only uses gas when in operation. Endless hot water for applications where there is a peak demand for only a few hours and then either low or no demand for hours, days or weeks at a time. TYPICAL RINNAI MANIFOLD PACK INSTALLATION. Manifold pack drawing Manifold Pack MP2 MP3 MP4 MP5 MP6 A 375 B 750 1125 1500 1875 2250 Dry Weight 60 kg 90 kg 120 kg 150 kg 180 kg MJ 400 800 1000 1200 This is not a formal engineering drawing Insulation not shown on site pipework Ablution areas: temper as required Installation as per local regulations Details subject to change without notice Non return and cold expansion valves are only required on circulating systems Please refer to Rinnai Commercial Representative when designing systems HD Model HD200 e HD200 i C 245 280 D 410 340 E 510 440 F 610 540 G 1500 H 850

Project Project Reference for MANIFOLD PACKS Kitchens in Resort World Sentosa - Universal Studio Singapore 25 Outlets TS424E/3PAV etc 0.2 x 1.6m & Onward 4,500L/h @ 60deg Pool Heating System What is a Rinnai Pool Heating System? Rinnai Pool Heating system consist of No. of Infinity continuous flow water heaters plumbed together with heat exchanger to heat up the water which contains chlorine or other chemicals. What are the key features? High durability of Infinity continuous water heater itself High speed recovery Space saving Pool Heating System Pool Heating System Bungalow house @ Andrew Road 13 Outlets TS224E/1PAV etc 0.2 x 0.8m & Onward 2,250L/h @ 60deg 06 07

Demand Duo DEMAND DUO What is A Rinnai Demand Duo SYSTEM? Rinnai Demand Duo is the combination of between 1 and 6 gas continuous flow water heaters with a storage tank. The storage tank allows a short period of high hot water flow rate, greater than the continuous flow rate of the Infinity water heater(s). TYPICAL RINNAI DEMAND DUO INSTALLATION. Demand Duo How does IT work? Demand Duo is a complete packaged storage hot water system made up of one or more Heavy Duty water heaters with a manifold system, primary pump(s), thermostat and a stainless steel storage tank. The thermostat senses the temperature of the water in the tank, and when it drops below the set point, the primary pump is activated. This flow in turn starts the Rinnai continuous flow Infinity water heater which returns heated water to the tank. What are some suitable applications? Hotels & Motels Apartment Blocks Student Accommodation Shower Blocks Commercial Kitchens Commercial Laundries Installations of this type typically have a predictable hot water volume, usually based on number of people living in a particular building either showering, washing or eating, or industrial machines that require regular peaks of water. Demand Duo are often used on projects on a flow and return system to distribute the water around the building. It should be noted that flow and return systems continually lose heat through the circulation pipework and this adds running costs to the project. How is the selection made? Refer to the table for selection examples on pg10. What are the benefits of rinnai Demand Duo? Demand Duo storage hot water systems hold 250 to 315 litres of hot water per system. This is available where high peak flow rates for short periods of time are common. This is not a formal engineering drawing Insulation not shown on site pipework Tank control box cover not shown Ablution areas: temper as required Installation as per local regulations Details subject to change without notice Recovery is matched by selecting the required number of Rinnai Infinity water heaters. The heater(s) can also be mounted many metres (remotely) from the tank. Note: Extended primary pipe runs must be oversized and/or a primary pump upgrade. Please contact your Rinnai Commercial Representative for further information. Rinnai Demand Duo systems can also be used instead of Manifold Packs for projects where limited gas supply is available. Model DD1 DD2 DD3 DD4 DD5 DD6 A 375 B N/A 725 1100 1475 1850 2225 C 1825 2200 2575 2950 3325 D 715 E PTR INCLUSIONS 1 x HT575 2 x HT575 3 x HT575 + Tee 1 x HT575 & 1 x Boiler Valve Primary Pump UPS20-60B UP25-80B UP25-80B UP25-80B UP25-80B x 2 UP25-80B x 2 Mj Rating (HD200 s) 200 400 800 1000 1200 Total System Weight (315 L) 92 115 135 155 175 190 Tank Model 250 Litre 315 Litre HD Model HD200 e HD200 i F 285 J 410 340 G 385 H 1475 1855 K 510 440 I 1690 2080 Dry Weight L 610 540 60 kg 72 kg Wet Weight 310 kg 385 kg M 1500 08 09

Demand Duo Selection Table Rinnai Demand Duo System Selection Table No. of Rooms 3-4 Star Rated 42 86 126 167 209 251 293 335 377 418 460 502 544 No. of Rooms 5 Star Rated 33 67 98 130 163 195 228 260 293 325 358 390 423 Rinnai Model TS124E(I)/1250L TS224E(I)/1250L TS324E(I)/2250L TS424E(I)/2250L TS524E(I)/2315L TS624E(I)/3250L TS724E(I)/3315L TS824E(I)/3315L TS924E(I)/4250L TS1024E(I)/4315L TS1124E(I)/4315L TS1224E(I)/5315L TS1324E(I)/5315L Recovery Litres @ 32º Rise (28º-60º) 1,375 2,500 3,875 5,000 6,255 7,500 8,820 9,945 11,125 12,510 13,635 15,075 16,200 First Hour Litres @32º Rise (28º-60º) 1,125 2,250 3,375 4,500 5,625 6,750 7,875 9,000 10,125 11,250 12,375 13,500 14,625 Tank Size (Litres) 250 250 2 x 250 2 x 250 2 x 315 3 x 250 3 x 315 3 x 315 4 x 250 4 x 315 4 x 315 5 x 315 5 x 315 Heaters 1 x Infinity24 2 x Infinity24 3 x Infinity24 4 x Infinity24 5 x Infinity24 6 x Infinity24 7 x Infinity24 8 x Infinity24 9 x Infinity24 10 x Infinity24 11 x Infinity24 12 x Infinity24 13 x Infinity24 Gas Rate MJ/Hour (Nominal) 188 376 564 752 940 1,128 1,316 1,504 1,692 1,880 2,068 2,256 2,444 Project References For DEMAND DUO Indoor System Retrofitting Project Sentosa Resorts & Spa (Beaufort hotel) Star Rate 5star No. of rooms 210 5 x TS 224E/1250L & 2 x TS 124E/1250L 1.5m x 0.8m 15,250L/h (Total) @ 60C 2nd hour & onward 13,500L/h (Total) @ 60C NSRCC 2nd hour & onward Changi coast walk 59 showersrooms TS424I/2250L 1.6m x 2m 5,000L/h @ 60C 4,500L/h @ 60C Project 586 456 TS1424E(I)/5315L 17,325 15,750 5 x 315 14 x Infinity24 2,632 628 488 TS1524E(I)/6315L 18,765 16,875 6 x 315 15 x Infinity24 2,820 669 521 TS1624E(I)/6315L 19,890 18,000 6 x 315 16 x Infinity24 3,008 711 753 795 837 553 586 618 651 TS1724E(I)/6315L TS1824E(I)/7315L TS1924E(I)/7315L TS2024E(I)/7315L 21,015 22,455 23,580 24,705 19,125 20,250 21,375 22,500 6 x 315 7 x 315 7 x 315 7 x 315 First Hour Delivery: Tank volume + 1,125litres per 1 heater. Hotel: 3-4 star 35L/min, 5star 45L/min. Allows for showers, meals and laundry. 17 x Infinity24 18 x Infinity24 19 x Infinity24 20 x Infinity24 3,196 3,384 3,572 3,760 New Project Wangz Hotel 2nd hour & onward Outram Road 41rooms TS324I/1250L & TS124I/1250L 1.6m x 2m 5,000L/h @ 60C 4,500L/h @ 60C For further information, please contact your Rinnai Commercial representative. 10 11

Project Project References For DEMAND DUO Project Outdoor System New Project The Legend of Fort Canning Park 74rooms TS 424E/2250E 2.2m x 1.4m @60C 5,000L/h @ 60C 2nd hour & onward 4,000L/h @ 60C Outdoor System New Project Park Regis Hotel @60C 2nd hour & onward Merchant Road 203rooms TS 924E/4315L 3.6m x 2m 11,385L/h @ 60C 10,125L/h @ 60C New Project Hotel Grand Chancellor @60C 2nd hour & onward Belilios Road 328rooms 2 x TS624E/2315L & 1x TS524E/2315L 2.4m x 2.0m (Bigger system) 21,015L/h (Total) @ 60C 19,125L/h (Total) @ 60C Retrofitting Project Hotel Miramar 200rooms TS 224E/1315L 1.5m x 0.8m @60C 2,565L/h @ 60C 2nd hour & onward 2,250L/h @ 60C 12 13

Project What is Hybrid system of Rinnai Gas system and Electric Heat pump? Since recovery rate of Electric Heat Pump System is quite slow and require big space, Rinnai Gas system is used to boost EHP(*1) system for faster recovery when demand of hot water is at peak. *1 : Electric Heat Pump system is supplied by the other party. Solar Pre-Heat System Introduction & Drawing What are rinnai Commercial Solar Pre-Heat systems? Rinnai Commercial Solar hot water systems provide solar pre-heated water to the Rinnai Commercial gas hot water systems such as the Manifold Pack or Demand Duo system. It can reduce fuel cost at each building and greenhouse gas emissions. Solar Pre-Heat System HYBRID SYSTEM with EHP The system is selected according to the daily hot water demand for the application, the required solar contribution, and what solar zone the system is located in. Project: City Gas Senoko Plant Project Reference: Resorts World Sentosa Resorts World Sentosa Star Rate 6 hotels Rinnai Solution 14 5 star Crockfords Hotel Festive Hotel Hard Rock Hotel Singapore Equarius Hotel Hotel Michael Spa Villas Concept Drawing Required valves not shown Please contact your Rinnai Commercial Representative for further details TS2024I 4m x 0.5m 22,500L/h @ 60C Width Height Depth Weight Solar Panels 1025 1937 80 36 kg Solar Tank 2080 NA 66 kg 15