Fire protection for townhouses that share a common wall. Gypsum Fire Wall



Similar documents
Fire protection for townhouses that share a common wall. Area Separation Wall. Systems

GYPSUM AREA SEPARATION FIREWALLS GA

CertainTeed. Shaftliner For A rea Separation Firewalls

H-Stud Area Separation Wall System

DensGlass Shaftliner for Area Separation Walls

eading Performance Solutions

Moisture Control. System Solutions to Prevent Mold

MOLD AND MOISTURE RESISTANT PAPERLESS SOLUTIONS FOR AREA SEPARATION WALLS

VA25014B0516 VA CINCINNATI PROJECT NO INPATIENT BED TOWER ADDITION (4 TH AND 5 TH FLOORS) SECTION GYPSUM BOARD

Comprehensive test information on fire-rated assemblies incorporating CGC products and systems. Fire-Resistant

Gypsum Board Systems Manual

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

PART 1 GENERAL 1.1 SECTION INCLUDES

Residential Roofing Guide

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Fire Protection. CANADIAN STEEL CONSTRUCTION COUNCIL 201 Consumers Road, Suite 300 Willowdale, Ontario, M2J 4G8. Floor Assembly No.

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

fire & soundproofing Insulation Roxul Safe n Sound Fire and Soundproofing Insulation for Interior Partition Walls and Floors

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

PB301 July Lightweight Building Solutions. Bushfire Protection.

Excerpts from the Canadian National Building Code (NBC)

Comprehensive information on fire-rated assemblies incorporating USG products and systems. Fire-Resistant. Assemblies

Rockwool Flexi Insulation Application Guide

FIRE AND SMOKE PROTECTION FEATURES

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

SAMPLE INSTRUCTIONS. Best Barns USA Assembly Book. the Denver. 12'x 12' or 12'x16' Revised November 29, 2010

EcoTouch Insulation with PureFiber Technology

FireWall. High performance fireresistant. FireWall.

Life safety assurance for modern building designs. Shaft Wall. Systems

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

DuPont Tyvek Commercial Air Barrier Assemblies Exceed Air Barrier Association of America, ASHRAE 90.1

How To Repair A Boat Landing Deck With A Boat Bed

WINDOW INSTALLATION GUIDE FOR NEW CONSTRUCTION - WOOD FRAMING

Tremco Fire Protection Systems Group Technical Bulletin

Mark Cramer Inspection Services, Inc.

Wood-frame Construction, Fire Resistance and Sound Transmission

Discipline: Structural Issued

FIRESTOPPING & SMOKE SEALS

March 14, Installation of Bay, Bow and Garden Windows

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

UL 580 TEST REPORT. Rendered to: ARMSTRONG WORLD INDUSTRIES. SERIES/MODEL: MW Vector PRODUCT TYPE: Ceiling System, 3' OC

Packaged Terminal Air Conditioner Wall Sleeve Installation

FIRE AND SMOKE PROTECTION FEATURES

Sun Windows General Information Sun New Construction Window Installation Instructions

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: FIRESTONE BUILDING PRODUCTS COMPANY, LLC

GYPSUM BOARD Guide Specification. National Gypsum Company SECTION GYPSUM BOARD PART 1 - GENERAL 1.1 SECTION INCLUDES

Fiberglas, Exterior Wall Thermal Insulation

CertainTeed. For Shaftwalls SHAFTLINER

Lightweight Partition Design for Residential and Commercial Buildings

The Case for Cross Laminated Timber: Part 2

Composite Panel Firewall Systems

Page & Turnbull imagining change in historic environments through design, research, and technology

CHAPTER 6 CONSTRUCTION TYPES

Asphalt Shingle Application Requirements

AUTHORIZATION TO MARK

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

GreenGuard Housewrap Installation Guide

CF-Mesa, CF-Light Mesa, CF-Flute, CF-Metl-Plank, CF-Striated, CF-Santa Fe, CF-Architectural Flat, CF...

POST AND FRAME STRUCTURES (Pole Barns)

Best Barns USA Assembly Book

Chapter 6 ROOF-CEILING SYSTEMS

Design No. U419 BXUV.U419 Fire Resistance Ratings ANSI/UL 263 "Reprinted from the Online Certifications Directory with permission from UL"

Fire Barrier Duct Wrap 15A

Uncovered Decks & Porches

Fire Resistance of Brick Masonry

SECTION STANDING SEAM METAL ROOFING

RACQUETBALL, HANDBALL OR SQUASH COURTS AND GYMNASIUM WALL SURFACES

PANELIZED HOME INSTALLATION GUIDELINE

Shingle Installation Guide

Window Installation Instructions

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

CertainTeed. GlasRoc Tile Backer

SECTION ALUMINUM FRAMED ENTRANCES and STOREFRONTS. System 402 Flush-Glazed Screw Spline Storefront

fire separating walls #2

usg.com/me USG Middle East, Ltd. Dammam, Saudi Arabia Fax:

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

LP OSB Sheathing & Structural 1 Sheathing

Superform Products Ltd.

Underwriters Laboratories Testing Information

Standard from CSI Part Section Format For Wood Framing For Metal Framing For Gypsum Sheathing

ROXUL Board Insulation Section Master Guide Specification (CAVITYROCK ) Page 1 April 2016

Fire Preventive and Fireproof Performance Test and Evaluation Procedure Manual

CHAPTER 7: Building Systems ROOFING SYSTEMS

ISO Types 1-6: Construction Code Descriptions

The Role of Acoustics in Curtain Wall Design:

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

B. ASTM C 533 Calcium Silicate Block and Pipe Thermal Insulation. C. ASTM C 547 Mineral Fiber Preformed Insulation

INSTALLATION OF A BAY WINDOW

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council RETAINED ON U.S.

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

Built to Last. Built for Beauty. Good. Solid. Logix. TM

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

Additions and Alterations

Transcription:

Fire protection for townhouses that share a common wall Gypsum Fire Wall Systems SA-925

Fire walls between adjoining townhouses must provide fire-resistive ratings to ensure the safety of occupants in adjacent dwellings. Noise attenuation is also important, to ensure that townhouse dwellers are not disturbed by sound from their neighbors. Fire and Sound Separation

User s Guide This brochure explains: Where fire walls are used The components of fire wall systems How to select and specify the appropriate components of a fire wall system Pages Understand Your System Overview 4 Applications Components Performance Testing Select Your System Performance Selector 9 Design Details Design Your System 12 Good Design Practices Specify Your System 13 Application Guide Specifications For More Information Customer Service 800 387.2690 Web Site www.cgcinc.com 3 CGC Gypsum Fire Wall Systems

Overview Effective fire resistance and sound attenuation are important considerations in townhouse design. A fire wall can be used in townhouses up to four stories (13.4 m (44 )) tall and with all common floor-ceiling heights. It must either be continuous from the foundation to the underside of the protected roof sheathing, or continue through the roof to form a parapet. The fire wall is designed to allow for collapse of the construction on the fire-exposed side without collapse of the entire wall. To do this, aluminum breakaway clips attach the separation wall to the adjacent framing. When one side is exposed to fire, the clips are designed to soften and break away, allowing the structure on the fire side to collapse, while the clips on the exposed fire side of the separation wall continue to support the wall. This allows the fire wall to remain intact, protecting the adjacent townhouse. Typical Fire Wall Assembly 50 x 100 mm (2 x 4) stud framing SHEETROCK gypsum panels (as required) 25.4 mm (1 ) SHEETROCK Gypsum Liner Panels sound batts min. 19 mm (3/4 ) airspace between 50 mm (2 ) fire wall and wood framing 50 mm (2 ) H-studs 610 mm (24 ) o.c. 50 mm (2 ) CGC C-Runners CGC aluminum breakaway clip fire blocking as required fire blocking as required 4 CGC Gypsum Fire Wall Systems

Applications CGC Fire Wall Systems are lightweight, non-loadbearing gypsum panel partition assemblies used to provide fire-resistive protection for common walls in townhouse construction. These systems install quickly and easily. Because they weigh at least 50% less than masonry walls, installation proceeds rapidly. In addition, use of these assemblies gains valuable floor space for the building interior, since thickness is 89 mm (3-1/2 ) compared to 200 to 300 mm (8 to 12 ) for a masonry wall without interior finish. 5 CGC Gypsum Fire Wall Systems

Components CGC Fire Wall Systems have been comprehensively tested for fire resistance ratings only when all of the system components are used together. Substitutions of any of the components are not recommended and are not supported by CGC. Refer to the appropriate product material safety data sheet for complete health and safety information. Gypsum Liner Panels SHEETROCK Gypsum Liner Panels Noncombustible core encased in water-resistant 100% recycled green face and back paper ULC/UL classified for fire resistance (type SLX) Panels are 25.4 mm (1 ) thick and 610 mm (24 ) wide with beveled edges and are available in 2400-4267 mm (8-14 ) lengths Refer to product submittal sheet WB2278 for complete information SHEETROCK HUMITEK Gypsum Liner Panels Noncombustible core encased in a water- and mold-resistant, 100%-recycled blue face and back paper ULC/UL classified for fire resistance (type SLX) Panels are 25.4 mm (1 ) thick and 610 mm (24 ) wide with beveled edges and are available in 2400-4267 mm (8-14 ) lengths Refer to product submittal sheet WB2313 for complete information Metal Framing Components CGC Steel C-Runner, CGC Steel H-Stud Galvanized steel CGC Aluminum Breakaway Clip Performs as a break-away fuse by melting or yielding from the rise in temperature on the fire side of the wall Allows the fire-engulfed structure to collapse independent of the fire wall Related Products Acoustical sealant Highly elastic, water-based sealant CGC All Purpose Joint Compound Versatile performer: tape, finish, texture, laminate, or skim coat Combines single-package, ready-mixed convenience with good taping and topping performance Refer to product submittal sheet J60A for complete information 6 CGC Gypsum Fire Wall Systems

Performance Testing CGC Fire Wall Systems have been independently tested to meet performance requirements for fire resistance, structural performance and sound control. Performance Tests Extensive testing and continuous improvements ensure that CGC Fire Wall Systems will provide the vertical fire resistance and sound performance that projects demand. Testing Methods CGC Fire Wall Systems have been tested to ensure long-term performance. All CGC products and systems undergo exhaustive testing to ensure that they meet exacting standards. CGC s products are Classified as to fire resistance and fire-hazard properties. As part of this protocol, Underwriters Laboratories of Canada, (ULC) and Underwriters Laboratories Inc. (UL) periodically audit production of these materials to ensure compliance with necessary properties. ULC and UL are independent, not-for-profit product safety testing and certification organizations that have tested products for public safety for over a century. Products and systems are tested in accordance with ASTM standards. ASTM International is one of the largest voluntary standards development organizations in the world, and is a trusted source for technical standards for materials, products, systems, and services. Sound Transmission Class (STC) rates the effectiveness of walls and other components at blocking airborne sound. Testing Results Fire Protection Fire walls must ensure that fire does not spread from one townhouse to the next. Building codes mandate that fire walls are tested according to specific test standards, such as CAN/ULC S101, or ASTM E119, Standard Test Method for Fire Tests of Building Construction and Materials, or its equivalent. Fire resistance testing ensures that this critical performance component will not be compromised when the system is properly installed. Fire testing results in the following: ULC/UL Classification of all gypsum panel components for fire resistance ULC/UL listing of system fire resistance Sound Control Sound control test data demonstrate the effectiveness of CGC Fire Wall Systems in attenuating sound. This means that occupants of adjacent buildings will have more privacy. STC ratings up to 60 are available. Moisture/Mold The best way to minimize damage from moisture and mold is to minimize or eliminate exposure to water before, during and after construction. In all cases where moisture intrusion occurs, eliminate all sources of moisture immediately. SHEETROCK HUMITEK Gypsum Liner Panels have a noncombustible, moisture-resistant core encased in a water- and moldresistant, 100% recycled blue face and black paper. When used in conjunction with good construction practices, this product will minimize, but not eliminate, the risk of moisture damage. 7 CGC Gypsum Fire Wall Systems

Performance Testing Sustainability The LEED (Leadership in Energy and Environmental Design) program is a guideline for building solutions established by the U.S. Green Building Council (USGBC). LEED's mission is to transform the building industry by establishing a common standard of measurement to define what constitutes a green building. To this end, LEED provides a framework for assessing building performance and meeting sustainability goals. This framework assigns points for certain sustainability criteria, such as sustainable site development, water savings, energy efficiency, materials selection and indoor environmental quality. Specific products cannot be LEED-certified, because there are many contingent factors in each project that must be considered. However, certain products may assist you in obtaining LEED points for your design solution. For example: CaGBC LEED Credits MR 2 Construction Waste 2.1 Divert 50% of project waste (by weight or volume) from landfill (1 point) Management 2.2 Divert another 25% of project waste (by weight or volume) from landfill (1 point) Recycled Content MR 4 4.1 If sum of project materials by value have 7.5% post-consumer or 15% post-industrial (1 point) 4.2 If sum of project materials by value have 15% post-consumer or 30% post-industrial (1 point) Local/Regional Materials MR 5 5.1 If 10% of project materials are shipped less than 800 km (500 miles) by truck, or less than 2400 km (1500 miles) by rail (1 point) 5.2 If 20% of project materials are shipped less than 800 km (500 miles) by truck, or less than 2400 km (1500 miles) by rail (1 point) Low-Emitting Materials EQ.4 4.2 Drywall installation (less than 50g/L per CSCAQM, Table 1) (1 point) The following chart lists CGC Fire Wall System products that may be eligible for LEED points. Using products with a high recycled content is only one part of the equation. Another key measure of sustainability is embodied energy, which assesses the total energy required to produce a particular material or building component and get it to a building site. For example, if you use a product with a high recycled content but need to ship it across the country, the embodied energy costs of transportation may outweigh any environmental advantages of using a recycled product. It may be more environmentally sound to ship products made of virgin material from a plant close to a job site. CaGBC LEED Credits MR 4.1 and 4.2 EQ 4 MR 5.2 Product Family Post- Post- Embodied Density VOC c Mfg. Raw Materials Consumer Industrial Energy a,b lbs./cu.ft. Efficiency (% by weight) SHEETROCK Panels ~5% 0%-95% 3.6MJ/kg 43-50 none 95+% 95% gypsum, 5% paper, percent varies across 95% 1% starch; special panel with 23 plants nationwide d 36.5% wax and glass fibre Joint Compound Drying Type 0 0 3 MJ/kg 100 <2 g/l 98% Limestone and latex Joint Compound Setting Type 0 0 3 MJ/kg 100 none 98% Plaster of paris, limestone & mica SHEETROCK Acoustical Sealant 0 0 <65 g/l Limestone, water, acrylic polymer For more information on LEED, visit the following web sites: U.S. Green Building Council Leadership in Energy & Environmental Design www.usgbc.org www.usgbc.org/leed/leed_main.asp Canada Green Building Council www.cagbc.org Notes (a) Megajoules per kilogram. (b) Transportation of gypsum board accounts for over 10% of the board s embodied energy, while mining accounts for less than 1%. (c) Section 01350 of the Material Specifications adopted by the Collaborative for High Performance Schools (CHPS) for VOC emissions. All FIBEROCK panels use FGD gypsum, but the FGD gypsum content of SHEETROCK panels changes from plant to plant and even day to day at any one plant, due to availability. The recycled contents above are approximate. While FGD gypsum is not available everywhere in Canada, CGC does have plants strategically located to meet your needs. Evaluation should be made for each job on the benefits of using FGD instead of natural gypsum. 8 CGC Gypsum Fire Wall Systems

Performance Selector 2 Hour Fire-rated Construction Non-loadbearing Acoustical Performance Reference Construction Detail Description Test Number STC ARL Index 25.4 mm (1 ) SHEETROCK Gypsum Liner Panels ULC Des W314 SA925 1 50 mm (2 ) CGC H-Studs 610 mm (24 ) o.c. or UL Des U336 89 mm (3 1 2") minimum 19 mm (3/4 ) air space both sides separating liner panels from adjacent construction 292 mm (11 1 2") Fire wall (non-loadbearing) ULC Des W314 46 RAL-TL-88-353 SA925 2 25.4 mm (1 ) SHEETROCK Gypsum Liner Panels or UL Des U336 50 mm (2 ) CGC H-Studs 610 mm (24 ) o.c. Protected wall (bearing or non-loadbearing) of wood or steel studs each side min 19 mm (3/4 ) from liner panels 12.7 mm (1/2 ) SHEETROCK Gypsum Panels 54 57 RAL-TL-88-348 Based on 50 mm (2 ) mineral wool batt on one side RAL-TL-88-351 Based on 2x4s and 75 mm (3 ) mineral wool batt one side 58 RAL-TL-88-347 Based on 2x4s and 50 mm (2 ) mineral wool batt on both sides 60 RAL-TL-88-350 Based on 2x4s and 75 mm (3 ) mineral wool batt on both sides Note These systems do not provide a fire rating for adjacent wood- or steel-framed walls. 9 CGC Gypsum Fire Wall Systems

Design Details Basic Interfaces Intersection at Roof 50 mm (2") CGC C-Runner roof rafter saw cut roof deck roof truss Exterior Wall Intersection (as required) SHEETROCK Gypsum Panels 2 X 4 stud weather barrier fire blocking as required SHEETROCK Gypsum Panels as required 50 mm (2") CGC H-Stud 50 mm (2") CGC C-Runners 2 x 4 stud framing 1.6 mm (0.063") CGC aluminum breakaway clip 25.4 mm (1") SHEETROCK Gypsum Liner Panels exterior sheathing exterior cladding Intermediate Floor Foundation two 50 mm (2") CGC C-Runners 10 mm ( 3 /8") TYPE S pan head screw 31 mm (1 1 /4") TYPE W or S screw sound insulation (optional) sealant fire blocking as required acoustical sealant 25.4 mm (1") SHEETROCK Gypsum Liner Panels joist 50 mm (2") CGC C-runner power-driven fastener 610 mm (24") o.c. sealant as required Runner Installation Components 35 mm (1 3 /8") 50 mm (2") 50 mm (2") space runner 6 mm ( 1 /4") apart 25 mm (1") 50 mm (2") 50 mm (2") 64 mm (2 1 /2") CGC C-Runner CGC H-Stud 1.6 mm (.063 ) CGC Aluminum Breakaway Clip 10 CGC Gypsum Fire Wall Systems

Clip Spacing Requirements 1220 mm roof (4') plywood roof deck Typical firewall roof parapets (height as required by code) ledgers trusses attic 15.9 mm ( 5 /8") SHEETROCK FIRECODE Gypsum Panel (as required) ceiling line intermediate floor/ceiling assembly fire wall 7 m (23') upper most 7 m (23') of wall requires CGC aluminum clips at 3 m (10') o.c. fire blocking at floor line intermediate floor/ceiling assembly intermediate floor/ceiling assembly 13.4 m (44') proven structural stability to 13.4 m (44'); Additional CGC aluminum clips must be added 1.5 m (5') o.c. for the wall section below the upper most 7 m (23') 50 mm (2") H-stud adjacent framing Note As allowed by code, 16 mm (5/8 ) SHEETROCK FIRECODE Core Gypsum Panels may be used as underlayment to roof sheathing with panels extending 1220 mm (4 ) on both sides of fire wall and possibly roof side at rake end. Clip placement on page 10 is for typical construction. 11 CGC Gypsum Fire Wall Systems

Good Design Practices Use this section as a reference if questions arise during the design or application of CGC Fire Wall Systems. This section is an overview of good design, application, installation and safety considerations that should be addressed when CGC s products and systems are used. This section outlines some major issues, but is not intended to be a comprehensive review. We recommend that architects and contractors seek the assistance of safety professionals, especially at the professional construction site, because there are many factors to consider that are not included here. For safety and material handling information, please refer to Chapter 13 of The Gypsum Construction Handbook, Centennial Edition. 1 System Performance CGC Inc. conducts tests on products and systems to meet performance requirements of established test procedures specified by various agencies. Upon written request we will provide test certification for published fire, sound, structural and other pertinent data covering systems designed and constructed according to our published specifications. Substitutions of any of the components are not recommended and are not supported by CGC Inc. 2 Clip Attachment Fire wall systems require attachment of aluminum breakaway clips to adjacent framing on both sides of the H-Studs. Clips are attached to each stud and vertical C-Runners with one 10 mm (3/8 ) TYPE S screw, and to adjacent framing with one 31 mm (1-1/4 ) Type W or TYPE S Screw. The system may be stacked to a maximum height of 13.4 m (44 ), and normally require a vertical clip spacing of 3 m (10 ) o.c. max. However, when the wall has a stacked height exceeding 7 m (23 ), clip spacing along each stud below the 7 m (23 ) stacked height must be reduced to 1.5 m (5 ) o.c. max. (see illustration on page 11). When the fire wall system is used as an exterior wall, with adjacent framing on only one side, clips must be spaced as noted in Section 3.2 of the Application Guide Specifications. Note, for this case, that two 10 mm (3/8 ) TYPE S screws are required for clip attachment to the vertical H-Studs. 3 Sound Control For maximum sound control with wall systems, seal the entire perimeter and between the horizontal, back-to-back Construction C-Runners at the intermediate levels with a minimum 6 mm (1/4 ) bead of Acoustical Sealant. 4 Limitations For use as a common 2-hr. fire resistance rated wall separating townhouses. Not to be used for shear walls. 5 Additional See SA100, Fire-Resistant Assemblies, for fire- and sound-rated systems; SA200, Acoustical Assemblies, for sound- Information rated systems; and SA934, Moisture-Resistant Assemblies, for information on moisture resistance. 12 CGC Gypsum Fire Wall Systems

Application Guide Specifications This guide specification is provided to assist you in specification of CGC Fire Wall Systems. If you have additional questions or would like more information regarding this or other CGC products and systems, please contact CGC at 800 387.2690. Part 1: General 1.1 Specify to meet project requirements. Scope 1.2 A. All materials, unless otherwise indicated, shall be manufactured by CGC Inc., and shall be installed in accordance Qualifications with its current printed directions. B. System must be built in accordance with applicable model code research reports. 1.3 All materials shall be delivered in their original unopened packages and stored in an enclosed shelter providing Delivery and Storage protection from damage and exposure to the elements. Damaged or deteriorated materials shall be removed from the of Materials premises. Installed panels should be protected from the environment and dry before enclosing the wall. Warning: Store all SHEETROCK Gypsum Panels flat. Panels are heavy and can fall over, causing serious injury or death. Do not move unless authorized. Use caution not to exceed floor limits or cause tripping hazards. 1.4 In cold weather during gypsum panel joint finishing, temperature within the building shall be maintained within the Environmental range of 13 to 21 C (55 to 70 F). Adequate ventilation shall be provided to carry off excess moisture. Storage and Conditions installation of products must be protected at all times from adverse environmental conditions and elements. Part 2: Products 2.1 A. 25 mm (1 ) SHEETROCK Gypsum Liner Panels (HUMITEK), 610 mm (24 ) wide, beveled edge, lengths as required. Materials B. CGC Steel H-Studs (200HS25), galvanized, lengths as required. C. CGC Steel C-Runners (200CR25) galvanized, x 3 m (10 ) length. D. CGC Aluminum Angle Clip 50 x 64 x 1.6 mm (2 x 2-1/2 x 0.063 ) Aluminum Breakaway Clips. E. Joint Treatment Select a CGC Joint System. F. Fasteners Screws (31 mm (1-1/4 ) Type W) (31 mm (1-1/4 ) TYPE S) (10 mm (3/8 ) TYPE S, pan head). G. Sound batts 25 mm (1 ), 38 mm (1-1/2 ), 50 or 75 x 400 mm (2 or 3 x 16 ) or 610 x 1220 mm (24 x 48 ). H. Acoustical sealant. 13 CGC Gypsum Fire Wall Systems

Part 3: Execution 3.1 A. Foundation Solid Wall Position 50 mm (2 ) C-Runner and securely attach to foundation with power-driven fasteners at both ends and spaced 610 mm (24 ) o.c. Space adjacent runner sections 6 mm (1/4 ) apart. Caulk under runner at foundation with min. 6 mm (1/4 ) bead of acoustical sealant. B. First Floor Install H-studs and liner panels to a convenient height (max. 610 mm (2 )) above the floor line. Install two thicknesses of 25 mm (1 ) liner panels vertically in C-Runner with long edges in H-Stud. Install H-Studs and liner panels alternately until wall is completed. Cap top of panels with horizontal C-Runner. Fasten C-Runner flanges at all corners both sides with 10 mm (3/8 ) TYPE S screws. C. Intermediate Floors and Bottom of Trusses Cap top of liner panels and H-Studs with C-Runner. Attach C-Runner for next row of panels to the C-Runner below with end joints staggered at least 300 mm (12 ). Fasten the C-Runners together with double 10 mm (3/8 ) screws at ends and 610 mm (24 ) o.c. Attach all H-Studs and vertical C-Runners to adjacent framing with Aluminum Breakaway Clips. Clips attaching H-Studs and vertical C-Runners to adjacent framing on both sides require attachment to the H-Stud and C-Runner with one 10 mm (3/8 ) TYPE S screw. Clips attaching H-Studs and vertical C-Runners to adjacent framing on only one side and with exterior exposure on the other side require attachment to the H-Stud and C-Runner with two 10 mm (3/8 ) TYPE S screws. Attachment to the adjacent framing is with one 31 mm (1-1/4 ) Type W or TYPE S screw. Locate horizontal C-Runner joint within 610 mm (2 ) of the intermediate floor. Install fire blocking between the solid wall system and adjacent framing at floor lines, bottom of truss line, and any other locations required by the applicable code. D. Roof Continue installing H-Studs and liner panels for succeeding stories as described. Cut the liner panels and H-Studs to roof pitch and length as necessary to follow the roof pitch. At roof, cap liner panels and H-Studs with C-Runner. Attach all H-Studs to adjacent framing with Aluminum Breakaway Clips. Clips attaching H-Studs and vertical C-Runners to adjacent framing on only one side and with exterior exposure on the other side require attachment to each vertical framing member with two 10 mm (3/8 ) TYPE S screws. 3.2 CGC Fire Wall Systems are suitable for exterior walls with an appropriate weather barrier installed over the system Exterior Wall and under an exterior cladding. Exterior exposure is limited to 718 Pa (15 psf) wind load and requires vertical clip spacing of 1220 mm (4 ) o.c. maximum. Exterior exposure requires attachment of the aluminum breakaway clips to each vertical steel framing member with two 10 mm (3/8 ) TYPE S screws. Attachment of the clips to adjacent framing is with one 31 mm (1-1/4 ) Type W or TYPE S screw. Uppermost clips should be placed as close to the roof line as practical attachment allows. 14 CGC Gypsum Fire Wall Systems

About the cover: Project Townhomes at Meridian Square Indianapolis, IN Design and Construction Ryland Homes Photographer Albert Vecerka/Esto

Customer Service 800 387.2690 Web Site www.cgcinc.com Metric Specifications CGC Inc., will provide metric conversions on its products and systems to help specifiers match metric design sizes. In addition, some products are available in metric dimensions from selected manufacturing plants. Refer to SA100, Fire-Resistant Assemblies, for additional information and a Table of Metric Equivalents. Trademarks The following trademarks used herein are owned by United States Gypsum or a related company: FIRECODE, SHEETROCK, USG. LEED is a registered trademark of the U.S. Green Guilding Council. Notice We shall not be liable for incidental and consequential damages, directly or indirectly sustained nor for any loss caused b application of these goods not in accordance with current printed instructions or for other than the intended use. Our liability is expressly limited to replacement of defective goods. Any claim shall be deemed waived unless made in writing to us within thirty (30) days from date it was or reasonably should have been discovered. Note All products described here may not be available in all geographic markets. Consult your local sales office or representative for information. Safety First! Follow good safety and industrial hygiene practices during handling and installation of all products and systems. Take necessary precautions and wear the appropriate personal protective equipment as needed. Read material safety data sheets and related literature on products before specification and/or installation. CGC Inc. 350 Burnhamthorpe Rd. W., 5th Floor Mississauga, ON L5B 3J1 SA-925 EWB-W152/rev. 12-06 2004, CGC Inc., CP Printed in Canada