Operating Instructions Serial Monitor 4040. ROBERT RIELE GmbH & Co KG



Similar documents
WinPFT File Transfer Utility (Catalog No ND7)

PRN_LOAD :22

AC500. Software Description. Scalable PLC for Individual Automation. Installation of the AC500 Control Builder PS501

Korosi Monitoring System (KMS) Software Manual

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

Operating Instructions

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units

SECTION 3 - INSTALLATION

Vicon Flash Upgrade Software

User Manual. Thermo Scientific Orion

CashFlow Programming Module CPM

Operating manual. SpectralTransfer. - Backup of measurement data - Backup and recovery of user-defined methods - Software and methods update

Chapter 3 Software Installation

Lab: Data Backup and Recovery in Windows XP

File Management Utility. T u t o r i a l

Installing the Gerber P2C Plotter USB Driver

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

IP SERIAL DEVICE SERVER

Vicon Flash Upgrade Software

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

PTPhoneManager II. User guide

CNC File Transfer Box. Connecting the CNC File Transfer. CNC Transfer Program

How To Connect A Directsofl To A Powerpoint With An Acd With An Ctel With An Dm-Tel Modem On A Pc Or Ipad Or Ipa (Powerpoint) With A Powerline 2 (Powerline

Empowered by Innovation. Setting Up and Using Fax Mail. P/N July 2006 Printed in U.S.A.

Keep it Simple Timing

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Addendum Advanced POS Printer Drivers

Allworx Installation Course

Lab - Data Backup and Recovery in Windows XP

Manual. Danfoss Central Station Communications Software Version 3

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

32 Transferring Projects and Data

Exeba -ATS. User Guide. Escan Technologies Corporation

Chapter 2 Utility Manager

FLoader User's Manual

DCOM Setup. User Manual

SA-9600 Surface Area Software Manual

testo easyheat Configuration and Analysis software Instruction manual

Instruction manual. testo easyheat Configuration and Analysis software

USB PC Adapter V4 Configuration

WindO/I-NV2 Utility Pass-Through Tool

Colorfly Tablet Upgrade Guide

Setting Up Your FTP Server

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

C-more Remote Access, Data Log, FTP File Transfer, and Tutorial

Handheld LPC Utility Software for Windows. Operation Manual

RDC-7 Windows XP Installation Guide

EPIC 950 THERMAL TICKET PRINTER

CentreWare Internet Services Setup and User Guide. Version 2.0

Maintaining the Content Server

ISK 200 Driver Installation

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

Update Firmware from GUI

Windows 95, Windows 98, Windows NT 4.0, Windows 2000, or Windows XP. Pentium PC Minimum RAM: 16 MB RAM Windows 95, Windows 98;32 MB RAM Windows NT 4.

When upgrading your TAPIT software make sure that all call accounting data has been exported before you begin the installation process.

DataLINE Data Retrieval

4 Networking Generators

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

PM1122 INT DIGITAL INTERFACE REMOTE

Installing ABACUS ELECTRICS USB Optical Probes under Windows 7

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

Guide to Installing BBL Crystal MIND on Windows 7

OFFICE KEYBOARD (MT1210 & MT1405) OFFICE FEATURES

VENTIsupport Version 1

Unique Micro Design Advanced Thinking Products. Model S151 UMD Transfer Utility for the Nippondenso BHT Series User Manual

DSA-1000 / PRT-1000 Device Server / Thermal Printer

History of Revisions. Ordering Information

APPLICATION. Using the PB-100 to Make Calls and Announcements From a Database. Using the PB-100 for All-Call Dialing

[HOW TO RECOVER AN INFINITI/EVOLUTION MODEM IDX ] 1

Centurion C4 Transfer Guide using C4 File Transfer Utility

Procedure for updating Firmware of EZ4 W or ICC50 W

GE Healthcare Life Sciences UNICORN Administration and Technical Manual

Installation Instruction STATISTICA Enterprise Small Business

Iridium Extreme TM Satellite Phone. Data Services Manual

Possum HC2006 SERO! Telephone. Firmware Upgrade and Software Manual firmware version 2.00+

1. Preparations Before Updating or Recovering

SYNERGY CONFIGURATION SOFTWARE AND HARDWARE SETUP V /02

MULTIFUNCTIONAL DIGITAL SYSTEMS. Network Fax Guide

ScanWin Installation and Windows 7-64 bit operating system

Chapter 1 Downloading Images to Your Computer (Windows)

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

EasySuite. User Guide V1.0

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

1 MAXDATA SR1202 Firmware Update

Using Bluetooth-Enabled PosiTector 6000 with Statistical Process Control Software

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

SHARP Digital Signage Software Pro PN-SS05 OPERATION MANUAL

DeviceNet Communication Card

SOFTWARE INSTALLATION INSTRUCTIONS

Operating Instructions

User Guide Wintex Software

DiskPulse DISK CHANGE MONITOR

LDCDP GdW. L force Controls. Ä.GdWä. Software Manual. Industrial PC. WindowsR CE Thin Client. Operating system

Using These Manuals. How to Use the. Software User Guide. Display examples: 1. Understanding How to Use Your Camera.

Administration guide. Host software WinCCU Installation. Complete gas volume and energy data management

Phone: Fax: Web: info@ctiautomation.net

MT-350 SMS. Operation Manual. PORTech Communications Inc.

Transcription:

Operating Instructions Serial Monitor 4040 ROBERT RIELE GmbH & Co KG Software Version 1.0 Documentation Version 05.2005

1 Introduction to Serial Monitor 4040 The software Serial Monitor 4040 was developed for the RIELE product: Photometer 4040 The operator controls the photometer via a PC which employs menu-driven software. Several tasks can be performed: Like the method editor of Photometer 4040 the software Serial Monitor 4040 supports the adapting of methods to the photometer. With special functions the user can upload and download pre-programmed methods. Additionally, methods can be created and edited on the PC. Customer defined methods can be stored in an external file. The operating of Photometer 4040 by the remote control can be demonstrated. The user can easily recognize the meaning and performance of the defined instruction set. General operating software contained in FLASH MEMORY of Photometer 4040 can be updated. Data file can be downloaded from Internet, floppy disk or CD ROM. The EDP can be demonstrated in a special terminal window. The contents of the window can easily transferred to other applications. ROBERT RIELE GmbH & Co KG Page 2 Introduction to Serial Monitor 4040

2 INSTALLING This chapter describes requirements and procedures for starting Serial Monitor 4040. 2.1 System requirements The minimum and recommended system requirements needed to install and run the program are as follows: Photometer Version 1.0 or higher Windows 95 Version 4.00.950 or higher Windows 98 Windows NT Version 4.0 or higher Windows 2000 Windows XP 2.2 Installation of software Insert the RIELE CD into the CD-ROM drive. In the run dialog box enter e.g.: D:\Riele_CD\Ph4040\Smon4040\setup.exe Select the button <OK> to invoke the Serial Monitor 4040 Installer. The Serial Monitor 4040 installation program starts. ROBERT RIELE GmbH & Co KG Page 3 INSTALLING

Confirm or enter new path of Serial Monitor 4040: C:\Cavo25RR\Smon4040 Select the button <Continue> to run the installer and follow the instructions. 2.3 Organisation of software Serial Monitor 4040 software is completely installed in a directory, e.g.: C: \Cavo25RR \Smon4040 \Dl_4040 \Files Other directories like \Windows\System are not changed or affected. The registry of Windows is updated. The directory C:\Ca_appsw is empty and may be deleted. 2.4 Deinstallation of software Use of the official deinstallation tool of Windows is recommended as the registry of Windows is updated. The software product is named with: Serial Monitor 4040 Also a special EXE-file can be used for deinstallation. The name of the file is Caindreg.exe. Its location is the directory of the application Serial Monitor 4040. In any case, the file Method.dbf containing all application data will not be cleared. The location of this file is the directory: \Files. ROBERT RIELE GmbH & Co KG Page 4 INSTALLING

3 STARTING Before starting the software connect PC and photometer in following manner: Switch off PC and Photometer 4040. Connect PC and Photometer 4040 with a data interface cable. For further information see: Service manual of Photometer 4040, chapter 6.1 Communication protocol Switch on PC and Photometer 4040. Start the program Serial Monitor 4040.EXE The program shows the following window. At the first time control and correct the language and COM port with the menu CONFIGURATION. ROBERT RIELE GmbH & Co KG Page 5 STARTING

4 Menu CONFIGURATION The menu CONFIGURATION makes the setting of different parameters possible. The settings are saved by the program and therefore correctly adjusted at the next program call. 4.1 Deutsche Sprache... selects German language 4.2 English language... selects English language 4.3 Configure Interface... selects COM port, baud rate, parity, data bits, stop bits. The default settings of the serial interface are as follows: Baud rate:... 9600 bit/s Data format:... 7 data bits, 1 stop bit Parity:... even For further information see: Service manual of Photometer 4040, chapter 6.1 Communication protocol 4.4 Set device selects different models of Photometer 4040 ROBERT RIELE GmbH & Co KG Page 6 Menu CONFIGURATION

4.5 Download operating system updates general operating software contained in FLASH MEMORY of Photometer 4040. The general operating software is supplied as a file. The actual file has the name P_100.hex. It can be downloaded by internet (see http://www.riele.de / Products / Photometer 4040 / Operating system). Besides specific files with different names are existing and can be used. Before proceding with uploading the specific file of general operating software should be copied to the directory Dl_4040 ( see chapter 2.3 Organisation of software). Before starting the procedure of download the Photometer 4040 has to be set to DOWNLOAD by [MODE], [SERIAL], [5] and [ENTER]. The Photometer 4040 displays: DOWNLOAD Attention: During the following procedure the FLASH MEMORY of Photometer 4040 will be erased and programmed electrically. The complete procedure needs up to seven minutes. During this operation be careful that there is no power fail out. Do not interrupt the connection between PC and Photometer 4040. The password is: 4040 ROBERT RIELE GmbH & Co KG Page 7 Menu CONFIGURATION

Select the first option Download to photometer and confirm with [ENTER]. Attention: Do not select the second option Resume after malfunction - without having a malfunction. In case of a malfunction the Photometer 4040 displays more than10 minutes after start: DOWNLOAD Vx.x PLEASE WAIT Contact your dealer for getting help. An open dialog is shown. Open the file e.g. P_100.hex. Never open the file D_load.hex. The download begins The window is closed and the progressbar shows the proceding of operation. After three up to seven minutes the Photometer 4040 stops the transferring of data with a reset operation. The new operating system is working. ROBERT RIELE GmbH & Co KG Page 8 Menu CONFIGURATION

After updating the general operating software of Photometer 4040 several initialization procedures have to be done by using service tools and utilities. A detailed description of the service tools is contained in the service manual of Photometer 4040 (see chapter 3.3 Service tools). A detailed description of the utilities is contained in the operating manual of Photometer 4040 (see chapter 8 Utilities). When errors appear during operation, first of all they have to be confirmed with [ENTER] before remedying (see chapter OM chapter 10 - ERROR MESSAGE / CORRECTION). Make a system initialization by applying the tool S1: With this function the default parameters will be set. Make a free methods initialization by applying the tool S2: This operation is optional. Attention! With this function all methods edited by the user are deleted without call-back. In the case of doubt these methods should be checked before: Scroll through all methods with the method editor and note them down for an optional later new programming. Make a parameter initialization by applying the tool S3: This operation is optional. Attention! The extended memory for the parameters of all nonlinear methods is deleted by this function without call-back and the corresponding user defined methods become useless. Make a setting of attribut of PCB layout by applying the tool S12: Software applications may be dependent on this attribut. Make a patients data initialization by applying the tool S13: Attention! The memory of patients data mangement is cleared completely. Define the laboratory name by applying the utility U17: The name of the laboratory can be stored permanently. Define the user names by applying the utility U2: The names of maximum five users can be stored permanently. Do a dark level adjustment by applying utility U1. Control the settings by applying utility U12. 4.6 Exit... quits the application ROBERT RIELE GmbH & Co KG Page 9 Menu CONFIGURATION

5 Menu TERMINAL The items of menu TERMINAL demonstrate the operating of Photometer 4040 by the remote control and EDP. 5.1 Remote control The menu REMOTE CONTROL gives the user the possibility to remote the photometer. All instructions are embedded in a STX / ETX / BCC-protocol. Each information represented by an ASCII-string starts with a start character (start of text = STX) and stops with an end character (end of text = ETX). After each ETX a block code character called BCC is send. The BCC is the result of a XOR-function including the information and the ETX. Protocols are accepted by the receiver with an acknowledgement (ACK) or a negative acknowledgement (NAK) character. Select the menu REMOTE CONTROL. Activate on Photometer 4040 the utility program REMOTE by [MODE], [SERIAL], [3] and [ENTER]. The Photometer 4040 displays: REMOTE ON The program shows the following window: Send button for instruction Close button for interface Single line edit for instruction History of data dialog Actual COM-port ROBERT RIELE GmbH & Co KG Page 10 Menu TERMINAL

Example for using remote instructions: Enter the character "B" to the single line edit for instruction and push the button Send. The command B gives the information about the firmware of Photometer 4040. The PC sends a protocol B to Photometer 4040. In history of data dialog the line appears: TxD:B TxD means: Transfer of data from PC to Photometer 4040 Photometer 4040 accepts the instruction with an acknowledgement character. In history of data dialog the line appears: RxD:ACK RxD means: receipt of data from Photometer 4040 Photometer 4040 sends to the PC the information about the software version. In history of data dialog the line appears: RxD:BV1.2a 29.04.05 D /1.0 The PC accepts the instruction with an acknowledgement character. In history of data dialog the line appears: TxD:ACK After a complete dialog Photometer 4040 sends M0 (Module 0 = M0) and C (Command = C) and is ready to accept a new instruction. For further details see Service Manual chapter 6.1 communication protocol ROBERT RIELE GmbH & Co KG Page 11 Menu TERMINAL

5.2 Printout to screen The menu PRINTOUT TO SCREEN shows the operating of EDP mode. The EDP mode of Photometer 4040 supports STX / ETX / BCC-protocol or CR /LF protocol. In menu PRINTOUT TO SCREEN all instructions are embedded in a STX / ETX / BCC-protocol. Each information represented by an ASCII-string starts with a start character (start of text = STX) and stops with an end character (end of text = ETX). After each ETX a block code character called BCC is send. The BCC is the result of a XOR-function including the information and the ETX. Protocols are accepted by the receiver with an acknowledgement (ACK) or a negative acknowledgement (NAK) character. Select the menu PRINTOUT TO SCREEN. Activate on Photometer 4040 the utility program EDP by [MODE], [SERIAL], [2] and [ENTER]. The Photometer 4040 displays: EDP OFF 1/ON 0/OFF Select the option [1]. Photometer 4040 displays: EDP ON 0/S-E-B 1/CR-LF Select the option [0] and confirm with [ENTER]. Photometer 4040 displays: METHOD NO. INPUT 1-250 The program shows the following window after selecting e.g. method 1 (C/F): ROBERT RIELE GmbH & Co KG Page 12 Menu TERMINAL

6 Menu METHODS The menu METHODS enables the user to upload and download pre-programmed methods. Additionally, methods can be created and edited on the PC. All methods are stored in a database called Methods.dbf situated in the subdirectory Files. The data base has the format of a dbase III-file. The file may be replaced with a pre-programmed file. 6.1 read from photometer... fills the database Methods.dbf with all user defined methods. The function also reads the status of the photometer and defines the range of the free programmable methods. If the database is not empty, the methods read will be merged with the existing ones. Select the menu READ FROM PHOTOMETER. Activate on Photometer 4040 the utility program REMOTE by [MODE], [SERIAL], [3] and [ENTER]. The Photometer 4040 displays: REMOTE ON The program shows the following window during reading from Photometer 4040: ROBERT RIELE GmbH & Co KG Page 13 Menu METHODS

6.2 write to photometer... stores all user defined methods of the database Methods.dbf to the photometer. The database methods will be merged or overwritten with the existing ones of Photometer 4040. Select the menu WRITE TO PHOTOMETER. Activate on Photometer 4040 the utility program REMOTE by [MODE], [SERIAL], [3] and [ENTER]. The Photometer 4040 displays: REMOTE ON The program shows the following window during writing to Photometer 4040: ROBERT RIELE GmbH & Co KG Page 14 Menu METHODS

6.3 Edit The browse view (write-protected): Browse view Form view Delete record Append record Go bottom Next record Previous record Go top The form view for fields to edit: ROBERT RIELE GmbH & Co KG Page 15 Menu METHODS

6.4 clear... deletes and packs all records of the database Methods.dbf 6.5 pack... packs the database Methods.dbf 6.6 Organization of the working memory of methods The working memory of Photometer 4040 is divided in two areas: The area of write-protected methods including basic methods with all available calculation procedures. The area starts with method 1 (End point with factor). With the function Methods write to photometer it is not possible to change the contents of this area. The area of not write-protected and write-protected methods. With the function Methods write to photometer it is possible to change the contents of this area. 6.7 Write protection of methods A method of Photometer 4040 can be protected against clearing und editing. The form view of the edit mode allows setting a checkbox with the name protected. Setting and resetting of the checkbox is only possible with a password. After writing to photometer a protected method can be cleared in the database. But the protected method of the Photometer 4040 can not be cleared. ROBERT RIELE GmbH & Co KG Page 16 Menu METHODS

7 Menu? The menu? employs the item: Info...shows information about application name and version ROBERT RIELE GmbH & Co KG Page 17 Menu?

ROBERT RIELE GmbH & Co KG Page 18