Software ECN # Change/Update Description Version 6.2.0.0 Mar252013 This version is continuation from 6.0.0.34/35 Added dual HC2 oven models and features from 6.5.0.18 Digital outputs from 2nd HC2 are available to use for Autocarb cooling option Single iomonitor program which can be used to connect to Primary or Secondary HC2 6.2.0.1 May312013 Add option to display blower settings on overview screen Add high blower limit setup in setup wizard Add new HC2 updater files (hc2xwd.o, hc2updater.exe, load_system) Fixed: Rail exercise option (for single rail single CBS config) Fixed: board animation issue when units are in inch (issue noticed in 6.0.0.36 and 6.2.0.0) Fixed: delayed cooldown with blower failure option Fixed: Power loss warning could not regenerate after acknowledged ActiveX functions corrected: (GetFurnaceBeltSpeed, GetRailWidth, GetFurnaceOxygenPPM) Fixed: security setup issue when user do not have access to load recipe. When program start with this user login, a recipe can be loaded. Now user cannot login to start oven program. Fixed: in version 6.2.0.0, profile port4 was reporting temperature from analog input3 instead of analog input16 Setup wizard defaults: Page1: Checked ON for Keep log files for 120 days option Make overview zone labels editable using overview studio program Fixed: when default recipe is created by oven program, records in recipe file were duplicated (issue in 6.2.0.0 version only). Normally default recipe is created when setup wizard is run. 6.2.0.2 June132013 ECN130017 001 Modifications to Hc2DriverUpdate utility so that HC2 firmware files can be uploaded even if HC2 linux side updater is not running Setup wizard correction: RPM channel# column on page7 will display only when both, blower RPM setup and delayed cooldown with blower failure, options are selected
6.2.0.3 Oct152013 Revise Lot tracking feature to add trailing edge events (based on 5.5.0.17 version) and SECS\GEM functionality Fixed: for 1705 model, belt channel on page7 was OFF by default Fixed: audible warning for blower failure Fixed: program crash related same recipe open in edit and operate mode Fixed: board animation travel length on overview display Add Czech language ini file 6.2.0.4 Feb042014 Add message when oven program starts to make sure oven is empty, no products in oven Fixed: Belt speed slowdown issue noticed on rare applications where boards are entered at high speed Fixed: Energy saving setup issue: when minimum blower speed is nonzero, in main program Energy saving option cannot be set, comes up with a message to enter number between min100 even if proper value is entered. Fixed: Autopurge/standby option issue: after Normal flow, Low N2 flow is not activated even oven is empty. Also modification made such that instead of direct sensor input check, oven empty logic using board count is used to trigger or reset low/normal flow timers Fixed: When blower group D & E are set for LMH, and recipe is loaded for the first time after HC2 reboot, warning for group D and E is displayed that it is set for lower than MIN value Fixed: Onscreen blower speed display issue for Chinese language. If recipe was set Low blower speed, the display was showing High but % value was correct. Fixed: Rise rate alarm issue for cool zone flux heater channels during recipe to recipe load Update to ActiveX "CHellerCommCtrl::genericInterface()" function to allow to read monitoring thermocouple data by 3rd party programs Local data log file for monitoring TC logs single decimal temperature now
6.2.0.4 " Fixed: Custom alarm/warning digital output function issue when option is set for active low digital input Fixed: Custom alarm/warning timer reset mechanism is corrected. Timers were reseting when acknowledge all alarm button is pressed even if warning is not generated yet Revise: if popup message for custom warning is already displayed on overview screen, new warning will not popup another message. Revised: Autolube timers will not be reset on oven program restart. Elapsed time from previous program run will be stored and used when program restarts. Add: option for SECS/GEM settable digital outputs Add: option in setup wizard to disable audible alarm/buzzer silense button in main oven program Add: when there is no communication between PC and HC2, but HC2 is controlling the oven, SMEMA will be off not allowing new boards into oven Default computer controlled N2 switch position will be ON for a default recipe created by oven program as part of oven setup Revised: 1913 single HC2 model, page7: zone13 channels can stay OFF if set OFF. In previous versions, the channels were resetting to ON state by design when setup wizard was accessed.
6.2.0.4 " Setup wizard update/corrections: Page1: by default "Keep log files for 120 days" option is unchecked Page2: Light Tower Setup window, change Alarm label to Buzzer Page2: remove unused Idle mode energy saving feature checkbox Page3: for 1914(single HC2) RL model, heater channel I/O selection labels are updated as Top2, Bottom2, Top1, Bottom1 Page6: animation3 and 4 check box issue, was getting unchecked for certain options Page6: SMEMA9851 New board delay option was tied to Lot Tracking option selection; now it is tied to SMEMA9851 interface selection Page6: four seperate edit boxes for predefined board length per lane Event log entry text for blower group AE is changed as below: from "Heat Zone Blower A" to "Blower Group A" "Heat Zone Blower B" to "Blower Group B" "Heat Zone Blower C" to "Blower Group C" "Analog Fan" to "Blower Group D" "Global Blower Control" to "Blower Group E" Fixed: at midnight date rollover, if oven is in cooldown mode, previous recipe name was getting logged instead of cooldown Update HC2DriverUpdate.exe: file upload progress is displayed within Step4 section instead of seperate popup window 6.2.0.5 Feb212014 RevA ECN140003 001 Fixed: Program crash relating to control rail option Fixed: SECS/GEM event 1040(recipe change) not being generated for cooldown if board count or smema options are not enabled Update: O2 Analyzer warnings for abnormal DDE data PPM=1, DDE link comm error PPM= 2, 4,5,..., O2 is not monitoring Fixed: ActivX function GetChannel() to report board processed count for all lanes (channel#49, 50, 51, 54) Fixed: NotificationEvent 60(board entry) and 61(board exit) was not generated for lanes 3 and 4. Also return data value is lane#1,2,3,4.
6.2.0.6 May162014 Fixed: setup wizard issue from 6.2.0.5 where Max board allowed by SMEMA was getting enabled when setup wizard is accessed Fixed: CBS Up/Down labels missing for few oven models Fixed: heat zone autoacknowledge warning for zones on a 2nd HC2 for dual HC2 model ovens Fixed: channel0 parameter change were not saving in edit mode, copypaste function issue for channel setup window Fixed: a rare issue with Mapmonw DDE link Fixed: overview studio operation for RL oven models with cool zones Update to data log file creation to add column header when new file is created Add: new option for Index info to barcode log file feature Add: Yamaha APCO option Add: new option to load autoclean recipe before manual cooldown load Add: new option, startup sequence controlled digital output Add: new option, Secs/Gem SMEMA control Add: new option, Secs/Gem settable warning EC 6.2.0.7 June092014 Add: light tower color (yellow or red) and buzzer setup for Secs/Gem configurable warning EC Fixed: overview layout for SMEMA indicator overlapping with blower speed display Fixed: Blower speed LMH settings were not matching to actual output, mixed up with adjacent channel Fixed: Channel setup screen flashing issue Fixed: For certain oven model setup with cool zone, cursor was not moving in sequence from channel to channel Fixed: Secs/Gem EC change event (30250) for blower speed change (groups A(39),B(40),C(41),D(35),E(34)) Align board animation bars for all 4 lanes, lane 3 and 4 were offset Fixed: Top1 label was attached to warnings, alarms for all zones Fixed: SECS/GEM SMEMA on/off control: if SMEMA2 without board count is selected, EC was not resetting to 0 after board entry Fixed: SMEMA9851 for lane3 and lane4 was not working without board count option Fixed: Blower setting on overview display to reflect Max setting in cooldown mode
6.2.0.8 July152014 Add: option for rail width SP in mm Update: ActiveX function Get/SetRailwidth(), SECS/GEM ID and data log entry for rail SP to support units in mm Add: option to display Alarm window access button on main overview screen Fixed: labels were missing in main program Edit > Analog control2 setup window Update: Oven.xml, event and data log text file is changed to unicode (UTF8) for asian language support. Add: Utility > SECS/GEM SMEMA option submenu to enable/disable option in main program Fixed: Secs/Gem CEID 1040 was not generated is cooldown is loaded manually Fixed: Board animation option: if animation is disabled in setup wizard after it was enabled, animation is displayed if board enters the oven. Only way to fix this was by deleting the OVW file; now animation is displayed based on setup wizard selection. Fixed: closed loop standby option: standby PPM setting was not editable, it was copy of normal PPM level Fixed: SMEMA indicator was misplaced on overview after using overview studio 6.2.0.9 July312014 Fixed below issues Program crash after accessing channel setup screen ActiveX function for GetRailWidth() Heat channel setup: cannot switch to manual mode Channel color issue for bottom 13 zone on 1913 model Add delay for Dansensor comm loss after turning N2 switch on to allow Rapidox to report proper PPM other than 1 6.2.0.10 Aug222014 RevB ECN140042 001 Fixed: communication issue for 1914(Single HC2) RL model Add new ActiveX function GetRailWidthFloat() Fixed: Audible alarm for Dansensor warning when Alarm2 Low is set Fixed: Offset entry program issue for channel 0 and 1, was writing 0 only This version is verified on Windows 8.1 64bit system as well.