KCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7



Similar documents
Handheld LPC Utility Software for Windows. Operation Manual

KI6501 Data Manager. Software User Manual

SA-9600 Surface Area Software Manual

SW43W. Users Manual. FlukeView Power Quality Analyzer Software Version 3.20 onwards

PP8X Printer Driver Installation Instruction

User Manual. Thermo Scientific Orion

KCU Communication. PC Software Installation and User s Guide For KCU-30 / KCU-40 / KCU-50 modules. System requirement: Windows XP or above

CANON FAX L360 SOFTWARE MANUAL

Config software for D2 systems USER S MANUAL

Table of Contents MONITORING SOFTWARE USER MANUAL

Real Time Monitor. A Real-Time Windows Operator Interface. DDE Compliant. (for remote data display)

SNMP-NET Client Shutdown Management Software for Windows 2000/XP/2003 User s Manual

Manual. Sealer Monitor Software. Version

DataLINE Data Retrieval

InsightPower Client. Shutdown Management Software for Windows 2000/XP/2003. User s Manual

Global Water Instrumentation, Inc.

Installing S500 Power Monitor Software and LabVIEW Run-time Engine

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

Transferring Scans from your Dolphin into Destiny

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

1. Installing The Monitoring Software

BMV-602 Data Link Manual

1 Installation. Note: In Windows operating systems, you must be logged in with administrator rights to install the printer driver.

Specific Information for installation and use of the database Report Tool used with FTSW100 software.

Access Control Software Manual

TX3 Series TELEPHONE ACCESS SYSTEMS. Configurator Quick Start. Version 2.2 Mircom Copyright 2014 LT-973

CLEARONE DOCUMENT (REVISION 1.0) October, with Converge Pro Units

PTPhoneManager II. User guide

32 Transferring Projects and Data

UPS Monitoring and Management Software

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

IGSS. Interactive Graphical SCADA System. Quick Start Guide

Brady IP Printer Installation Instructions

RDC-7 Windows XP Installation Guide

Centurion PLUS CPC4 Download Guide

Installation Instructions for 9555 USB Driver

User Manual V1.0. Remote Software

USB HSPA Modem. User Manual

Installing PowerLink on Windows 7 64-bit

User s Manual. Management Software for Inverter

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

PMS. Energy management and monitoring software. Installation and operation instructions

Installing Remote Desktop Connection

Fujitsu SCSI Scanner Installation Procedures Windows 95\98\98SE\ME\2000\XP\Vista

Use your mobile phone as Modem. Intel Easy Steps Intel Corporation All rights reserved.

User's Reference Guide for PowerAlert UPS Management Software Version 10.2 for Windows

UPS Monitoring Software. User manual Borri Power Guardian

FACTORY AUTOMATION MANUAL USB VIRTUAL COM PORT DRIVER INSTALLATION UNDER WINDOWS XP/WINDOWS 2000

Network Printing In Windows 95/98/ME

Supplemental USB Driver Installation Guide

Monitoring Network DMN

HL2170W Windows Network Connection Repair Instructions

SAPIP GUI INSTALLATION. Table of Contents

Guide for Remote Control PDA

Installing the Gerber P2C Plotter USB Driver

ViewPower User Manual

SignTrak STOLS User Guide x4034 SignTrak 05/06/09

Colorfly Tablet Upgrade Guide

IXP120 Alarm Monitor Utility

STIM202 Evaluation Kit

SentryPlus. Shutdown Management Software for Windows. User s Manual

Elo 1725L 17 Touch Screen Monitor Installation Guide. Product Name: Elo 1725L 17- inch Monitor

JVC Monitor Calibration 2 User's Guide

The FlexiSchools Online Order Management System Installation Guide

Acer LCD Monitor Driver Installation Guide

Data Management Software. CL-S10w. Installation Guide

Motorola Phone Tools. Quick Start

User Manual WatchPower

GV-Keyboard. User's Manual V2.0

PCLinq2 Hi-Speed USB Bridge-Network Cable. Quick Network Setup Guide

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

NVMS User Manual

1 Minimum system requirements

Select Correct USB Driver

User s Manual for Fingerprint Door Control Software

Datalogger Graph Software Help

Maintaining the Content Server

Professional Surveillance System User s Manual

VMS A1 Client Software. User Manual (V2.0)

System Requirements. Hiro H50113

AIM SOFTWARE AND USB DRIVER INSTALLATION PROCEDURE

AXIS Camera Station Quick Installation Guide

TEMP MONITOR_S2 Software operation instructions

SECURITY SYSTEM MANAGEMENT SOFTWARE FOR WINDOWS. Quick Start Instructions

SoundLAB Software Download Software from the Bogen website:

Network DK2 DESkey Installation Guide

SubCue Analyzer Software - Introduction

SYNERGY CONFIGURATION SOFTWARE AND HARDWARE SETUP V /02

USER GUIDE WEB-BASED SYSTEM CONTROL APPLICATION. August 2014 Phone: Publication: , Rev. C

Quick Installation and Setup for WinPower Software

EasyGate UMTS Data quick installation guide

Virtual Office Remote Installation Guide

TBS Help Index / On Board Software User Manual

Use only a shielded parallel interface cable that is IEEE 1284-compliant and/or a USB cable that is no longer than 6 feet long (1.8 meters).

Technical Data Sheet

RGK60 RGK50 RGAM10 RGAM20 RGAM4 Generator set control units

Bluetooth HC-06 with serial port module Easy guide

Quick Start Using DASYLab with your Measurement Computing USB device

NVMS USER MANUAL. Version 2.1.0

Moxa Device Manager 2.0 User s Guide

Transcription:

KCU-02 Monitor Software Installation User Manual For Windows XP and Windows 7 Headquarters : No.3, Lane 201, Chien Fu ST., Chyan Jenn Dist., Kaohsiung, TAIWAN Tel : + 886-7-8121771 Fax : + 886-7-8121775 URL : http://www.kutai.com.tw

TABLE OF CONTENTS Section Page Section 1 Application Installation... 3 Section 2 System Setting... 6 Section 3 Connecting to Network... 8 Section 4 Monitoring... 11 Section 5 Parameter Setting... 15 Section 6 Figure Recording... 18 2

SECTION 1 : Application Installation 1. Insert the installation Disk into CD ROM drive. 2. Double click on file setup.exe to begin installation. Figure 1-1 3. Select the primary installation directory and press Next. Figure 1-2 4. The Installation Wizard will display the summary of installation content, and then press Next. Figure 1-3 3

5. Software installing Figure 1-4 6. Installation completed. Press Next Figure 1-5 4

7. Install Run-Time Engine Driver software. Figure 1-6 Figure 1-7 8. When the Run-Time Engine Driver installation is completed, press OK to finish installation process. Figure 1-8 9. Click on Yes to restart. Figure 1-9 5

SECTION 2 : System Setting In the system setting, user can modify data, event log, record path and data extraction parameters and interface language. Open KCU-02 Monitor.exe, then click Option (See Figure 2-1), to open Option setting window (See Figure 2-2). Each System setting is illustrated below: Event Log Record Path Setting the Event Log Record Path to file, when a Note or alarm generated, the system will automatically record the contents of the event, and save to file when leaving exiting monitoring. Attention:Event Log Record is not available on ATS-PLC Data Log Record Path When opening the monitor, the system will record the data at regular intervals and stored to file, this setting can change the directory of the data chart record and stored. Figure 2-1 Options Models available with Data Log Record:AMF-10, GCU-100, GCU-3000 Figure 2-2 Program Setting Data Acquisition Interval The system retrieves data every few seconds and store into file. Data are retrieved daily until 23:59pm and then system automatically retrieves and save data into a new file after 00:00am. Attention : More frequent the recording interval is, larger the size of stored file becomes. 6

Data Storage Interval When connection is terminated, system will automatically retrieve the data and store into file. The setting of data retrieval and saving to file can be adjusted according to the amount of data accumulated. Intermittent data saving ensures preservation of records. Attention : The efficiency of the system will be affected if the data storage is set frequent. Language By changing the setting of display interface language, the language from event log language will also change accordingly. Attention:System changes will take effect after restarting the application. 7

SECTION 3 : Connecting to Network 3.1 Device Connection Install the KCU-02 into the expansion slot at the back of the controller. Via the RS485 cable, connect PC to the RS485 device then connect from device to KCU-02, make sure the controller is power on and then run file KCU-02 Monitor.exe. Click COM Port key to enter port setting (Figure 3-1). Figure 3-1 Choose the correct COM port and baud rate (the baud rate must be consistent with the Controller) and then click Connect (Figure 3-2). Figure 3-2 Selecting COM port and Baud rate System resumes to main screen and automatically searches for all installed devices. (Figure 3-3). Figure 3-3 Searching for device 8

The searching process may take a few seconds only and then display all connected device(s). Figure 3-4 Connected Device 3.2 Re-Scan for device To update or scan for installed device(s), go to the main screen and click on the Scan Device key (Figure 3-5) Figure 3-5 Re-Scan for Device 3.3 Disconnect To disconnect or remove device, click on the Disconnect key from the main screen. (Figure 3-6) Figure 3-6 9

3.4 Online Controller Listing After the system completes searching available controller(s), all connected controller(s) and status will be displayed on the top left of the screen. 1. Thumbnail of the connected controller. 2. Controller ID and model name. 3. Indication of the current displayed monitor of corresponding controller on the display screen. 4. The 3 types of controller status (As shown below). Operating Warning or Shutdown Offline Status 3.5 Event Overview When the controller sends out a Note signal, the system will record the corresponding controller ID, Note message and time of occurrence in the event log. (As shown from the below illustration). 1. Event ID( Don t care) 2. Description of event 3. Time of occurrence Figure 4-9 Ensure whether the Modem is connected 10

SECTION 4 : Monitoring KCU-02 is able to connect to several controllers via RS485 at the same time. By clicking on different controller icon on the left of the screen, the display screen will immediately open up the corresponding controller s monitoring screen. The current supportive modules include AMF-10, AMF-11, GCU-100, GCU-3000, ATS-22, ATS-33, ATS-34, ATS-PLC. * Majority of the display content and function of the ATS-PLC, is synchronized with actual operation Example:Monitoring GCU-100 Figure 4-1 Controller Monitoring Screen 4.1 Virtual Operation On the PC monitoring screen, all functions and lightings are virtually displayed and synchronized with the actual controller status (See Figure 4-2) Attention : The displayed screen varies with different controller connected. Figure 4-2 Virtual Operation 4.2 Generator Status As shown in Figure 4-3. There are total of seven types of generator operation status. Figure 4-3 Generator Status 11

Running Engine Shut-down Engine Coiling down Idle Stop Pre-Heat Cranking 4.3 Other Information Shown in Figure 4-4 Attention:The displayed frame varies with different connected control modules. Maintain (HH:mm):Maintain service countdown. Run Hr.(H:m):Hours of operating. Battery:DC Voltage. Figure 4-4 Other Information 12

4.4 Connection Status As shown in Figure 4-5 displays the current controller connection status. Link:There are two connection methods to KCU-02 module, USB Port Connection and Modem Connection. It will display the connection method here. Device : The control module of current connection. Figure 4-5 Connection Status Connection Status Connecting Disconnecting 4.5 Instrumentation As shown in Figure 4-6. The instrumentation displayed content, meter scales and related settings vary according to different control module connected. Attention:The displayed frame varies with different connected control modules. Figure 4-6 Instrumentation 13

The Figure 4-7 is emergency power meter. Under voltage setting on 180VAC Over voltage setting on 250VAC Figure 4-7 4.6 Emergency Stop Button This is emergency stop button shown in Figure 4-8. The system will automatically send out emergency stop command when clicked on it. Figure 4-8 Emergency Stop Button When controller system internal setting allow remote access, then the button will appear to be accessible status (Figure 4-9); When access is deactivated, the button will appear as un-accessible shows in (Figure 4-10). Attention:When the remote access is cancelled, all executing button are deactivated on the virtual operation display. Figure 4-9 Figure 4-10 If remote access is activated, when click on the emergency stop button, a pop up window will appear and requesting for confirmation of execution. Click OK and system will immediately execute emergency engine stop. Ensure whether to activate emergency stop 14

The pointer will pop up when clicking on the emergency stop button with the controller switch OFF. It will show OFF mode already SECTION 5 : Parameter Setting From main screen, select Controller Setting to open parameter setting. Controller must be switched to OFF status prior to programming, otherwise system will not be permitted to enter parameter setting screen (See Figure 5-1). Figure 5-1 Attention : Controller must be switched to OFF status prior to programming, otherwise system will not be permitted to enter parameter setting screen (See Figure 5-2). Figure 5-2 Can only enter setting at OFF Mode After opening up the setting page, and changed the parameter(s), if the new setting differs from previous setting, the green markers (See Figure 5-3) on the left of the parameter will be highlighted, indicating has changed the setting and waiting to be updated. :Default setting or setting not changed. :Parameter(s) changed and awaiting to be updated. Figure 5-3 15

Example:In Figure 5-4, 2 parameters have been changed, after clicking on the Update button the system will execute remote update. The update process usually take a few seconds only, some updates are immediately effective and displayed (Reference from Figure 4-7) Figure 5-4 Modified Entry will be marked Default, in anytime, user can click on the Default key to resume to factory settings. Any setting that differs from the default, the markers will be highlighted. Click on the Update key to continue setting update. Figure 5-5 Update Complete 16

Section 6 : Recording Record key is available on the top left of all monitoring screen (See Figure 6-1). Click on the Record key to open and view Graph Recording (See Figure 6-2). Figure 6-1 Once the system is online, it will immediately begins to record data according to user s setting and transforming each periodic recording into curve chart. Each chart s vertical coordinates will be automatically adjusted by system. Figure 6-2 Graph Record Log 6.1 Show Curve Lines The selection box enable user to choose whether to display curves which enables user to better observe certain curve graphic. : Show Curve Lines : Hide Curve Lines Figure 6-3 Selection box 17

6.2 Drop-Down Menu Scale Range It can adjust the length of data to be showed at once with scale range of 1 minute, 10 minute, 30 minutes, 1 hour, 5 hours, 10 hours and one day. Figure 6-4 Within 10 minutes Range Figure 6-5 Within 1 minute Range 6.3 History Record To view history files, click File button and select history file of which the file names shows the file currently being reviewed. Furthermore, the data acquisition will continue processing wile files are being opened and reviewed. Click on Close File to return to data acquisition menu. Attention:The record file can only be selected according to the current monitoring module. If the current monitoring module is GCU-3000, then only GCU-3000 record file can be selected. Figure 6-6 History File Record Log 18

6.4 Function of Cursor Click on Cursor button to activate the coordinate axis on each diagram. The coordinate axis on the diagrams will move along with the motion of mouse simultaneously (See Figure 6-7) and display the time period of cursor position (See Figure 6-8). Figure 6-7 Cursor moves with the mouse Current time of the cursor Figure 6-8 Shower the current time 19