Similar documents
The disposable dispersing system ULTRA-TURRAX Tube Drive control (UTTD control)

Laboratory scale mixers

Specials. designed. 3rd edition 2015 English. for scientists 1

Mill Collection. CT 193 Cyclotec TM, CM 190 Cemotec TM, KN 195 Knifetec TM, HM 294 Homogeniser and HM 297 Homogeniser. Labtec Line

Magnetic Stirrers. Patented. Ncm % RET control-visc with white coated heating plate! Mixing Magnetic stirrers

DigiBlock Sample Preparation System APPLICATION NOTES LABTECH INC. Your Lab, Our Tech

Genomic DNA Extraction Kit INSTRUCTION MANUAL

Homogenizer with Direct Controller. Digital Homogenizer with Remote Controller. Homogenizing Stirrer, for use with Tissue Grinders.

DECANTER CENTRIFUGE. CENTRIFUGE TECHNOLOGIES

Material AICLE. 5º de Primaria.: Food and nutrition (Solucionario)

Twin Screw Pump. WANGEN Twin. The hygienic solution for food, cosmetics and chemicals

Nutrients: Carbohydrates, Proteins, and Fats. Chapter 5 Lesson 2

Alfa Laval decanter centrifuge technology. Separating solids from liquids

Monitoring & Recording Hazardous & Non-Hazardous Waste

MEDICAL WASTE DISPOSAL POLICY. EFFECTIVE DATE: January 31, 1991 REVISED DATE: April 1, 2008 I. AUTHORITY TO ESTABLISH DISPOSAL POLICY:

MILESTONE START D. Microwave Digestion System

Vacuum drying oven for non-flammable solvents

GCC STANDARDIZATION ORGANIZATION (GSO)

FOOD PREPARATION VEGETABLE PREPARATION EQUIPMENT

Chromatography...Oh Yeah!

Determination of Specific Nutrients in Various Foods. Abstract. Humans need to consume food compounds such as carbohydrates, proteins, fats,

Mitos P-Pump. product datasheet

Fiber. What is fiber? Fiber is a part of plant food. There are two types of fiber:

Sterilization methods and equipment Lab 1-2

Shakers. designed. to work perfectly

ANALYSIS OF VITAMIN C

M I C R O W A V E O P E N V E S S E L D I G E S T I O N S Y S T E M T HE NEW MIL E STO NE MILESTONE

STABILITY TESTING: PHOTOSTABILITY TESTING OF NEW DRUG SUBSTANCES AND PRODUCTS

BASIS RANGE TMB SERIES

Lab Exercise 3: Media, incubation, and aseptic technique

Utah Division of Solid and Hazardous Waste Solid Waste Management Program

top 5 fat burning tips by steve dennis

ORGANIC SAMPLE PREPARATION

Safety Safety glasses or goggles must be worn in the laboratory at all times.

HMHF DIRECT DRIVE BELT DRIVE. Manufactured by UDY Corporation. Cyclone Models Available:

kymanual or Automatic - it s your Choice

Return to Lab Menu. Acids and Bases in Your House

Manufacturing Services. Operational solutions for chemical, pharmaceutical, nutraceutical and cosmetic companies

Titanium Dioxide Raspberry Solar Cell 2012, 2011, 2005 by David A Katz. All rights reserved

It is an important tool to assess factors that affect the bioavailability of a drug from a solid preparartion.

SPILL PREVENTION, CONTROL, AND COUNTER MEASURES PLAN (SPCC)

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

World Class Equipment worldwide Edition J

STANDARD OPERATING PROCEDURES Safe Autoclave Operations

Running Head: ACTION OF CATALASE IN DIFFERENT TISSUES 1. Action of Catalase in Different Tissues. San Nguyen. Biol 1730.

VX Series Pumps Rotary Lobe Pumps designed for abrasive and viscous liquids. HIGH PERFORMANCE PUMPS DESIGNED FOR TOUGH APPLICATIONS ENGINEERED TO WORK

Nutritional Glossary. Index of Contents

STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

MILESTONE H E L P I N G C H E M I S T S

IDENTIFYING YOUR WASTE

ArtisanLink Staining System is an automated special stains slide

Blood Collection and Processing SOP

DP419 RNAsimple Total RNA Kit. RNAprep pure Series. DP501 mircute mirna Isolation Kit. DP438 MagGene Viral DNA / RNA Kit. DP405 TRNzol Reagent

Laboratory 5: Properties of Enzymes

MORTAR GRINDER FRITSCH MORTAR GRINDER IDEAL FOR

Macromolecules in my food!!

Autoclave Safety. Autoclaves are sterilizers using high pressure and high temperature steam. The potential safety risks for the operators are:

IDENTIFICATION OF POLYMERS 1998 by David A. Katz. All rights reserved

Procedure for Protein Analysis. Protein Extraction

Nu G Medical Waste System Technology (Pyrolysis / Thermal Decomposition)

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.

Customer: Cardiff Hospital NHS (United Kingdom) Machine:

Solid dosage forms testing: Disintegration test and tablet friability and hardness

WASTE WATER TREATMENT for surface treatment applications

DETERGENTS. Application Recommendations. Application/ Concerns. Recommended Detergent. Articles Cleaned/ Soil Removed. Cleaning Method.

Vitamins & Minerals Chart

High pressure reactors Where are your limits?

Handling Corrosive or Abrasive Liquids

Laboratory Biosafty In Molecular Biology and its levels

FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

Hazardous Waste Procedures

Name. Lab 3: ENZYMES. In this lab, you ll investigate some of the properties of enzymes.

Fundamental Autoclave Techniques

Screw Cap Micro Tubes

CLINICAL AND RELATED WASTE OPERATIONAL GUIDANCE

LOCAL ARRANGEMENTS FOR WASTE DISPOSAL (BEGBROKE SITE)

BIO MEDICAL WASTE MANAGEMENT

ABEL Positive Displacement Pumps

Chuck Neece Director Research and Development FUMPA BioFuels

Revised EHS Biosafety. 1 Select appropriate containers/bags for autoclaving.

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

7. Chemical Waste Disposal Procedures

CappController Pipette Controller. Operation Manual Version:

RET control-visc. The Magnetic Stirrer for Scientists. designed. Phil S. Baran Ph.D. Baran uses IKA equipment. to work perfectly

DYNO -MILL ECM. Dispersion and wet grinding technology brought to perfection. High-efficiency agitator bead mill. Willy A. Bachofen AG Maschinenfabrik

OSMOSIS AND DIALYSIS 2003 BY Wendy Weeks-Galindo with modifications by David A. Katz

MZToothed colloid mill

Kompressoren. Adsorption Dryer AD

MOISTURE (Karl Fischer, Buffered)

Chapter 3: Separating Mixtures (pg )

Course Curriculum for Master Degree in Food Hygiene /Faculty of Veterinary Medicine

Appendix H IBC Managing Biohazardous Waste SOP

TEACHER ACTIVITY GUIDE

Sealed Air Corporation. Intermediate Bulk Containers For Aseptic and Non Aseptic Products

INDUTAINER COLLAPSIBLE IBCs FOR LIQUIDS

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

Queen s University Environmental Health & Safety

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

Transcription:

ULTRA-TURRAX Tube Drive System

ULTRA-TURRAX Tube Drive ULTRA-TURRAX Tube Drive control 3 Principle World s first: universal disposable disperser system with hermetically sealable sample tubes. Protection and security are provided for infectious sample materials, toxic and high-odor substances under defined conditions (time, energy, volume). Test procedures are easily duplicated with no cross-contamination between samples. The control model provides a turbo function and reverse rotation switch to optimize mixing and crushing performance. The control USB interface enables PC operation and data storage. Procedure The sample containers (tubes) are easily attached to the drive unit. Desired speed and duration are set, then the test is started. An acoustic signal indicates completion of experiment. All tubes are available in two sizes: 20 ml tube : working volume from 2 to 15 ml 50 ml tube : working volume from 15 to 50 ml ULTRA-TURRAX Tube Drive UTTD One-of-a-kind disposable dispersing system with hermetically sealable disposable sample tubes. Provides a means for safe processing of infectious, toxic sample materials and strong-smelling substances. - Dispersing, stirring, and grinding with a single drive unit - No possibility of cross-contamination - High level of user safety - Suitable for individual use or use in series - Anti-locking function - Chemical-resistant plastic - Simple and safe disposal Technical data Motor rating input / output 20 / 17 W Speed range / turbo speed 300-6.000 rpm Display LED (timer) Speed display scale (0-9) Timer 1-59 s (300-6.000 rpm) 1-29 min (300-4.000 rpm) Reversal of rotating direction interval - General Data Dimensions (W x D x H) 100 x 160 x 40 mm Weight 0,75 kg Protection class acc. to DIN EN 60529 IP 20 Ident. No. Single Unit 3646000 Ident. No. Workstation* 3645000 ULTRA-TURRAX Tube Drive control UTTD control The control version offers these additional advantages: - USB interface for experiment control and documentation - Collecting tray for protection against leaking liquids - Simple, precise and multilingual menu navigation with OLED display - Programmable sample conditions (library) - Tubo button for short-term, intensive mixing, dispersing and grinding - Adjustable reverse operation Technical data Motor rating input / output 20 / 17 W Speed range / turbo speed 400-6.000 rpm / 8.000 rpm Display OLED Speed display digital Timer 10 s - 30 min (infinitely adjustable) Reversal of rotating direction interval 10-60 s General Data Dimensions (W x D x H) 122 x 178 x 48 mm Weight 1,0 kg Protection class acc. to DIN EN 60529 IP 20 Ident. No. Single Unit 4135300 Ident. No. Workstation* 3827500 * For information on workstation, see page 11.

The IKA Tubes DT TUBE 5 Tube lid ST TUBE Tube with stirring device 20 ml 50 ml Suitable for: - Mixing - Stirring - Extractions - Preparation of soil sample suspensions ST Tube - Dissolving properties of drugs - Incorporation of coloured pigments into a solvent - Accelerated dissolution of sugar solutions - Extraction of plant substances - Accelerated dissolution of tablets, dragées, suppositories and capsules - Mixing of fluids with higher viscosities liquid + powder Rotor Stator DT TUBE Tube with rotor-stator element 20 ml 50 ml Suitable for: - Dispersion - Homogenization - Suspensions - Pharmacokinetics - Metabolism studies - Diagnosis DT Tube - Homogenization of tissue samples including brain, liver, muscle tissue, kidney and lung - Milling of plant samples including rosemary, rapeseed, tomato seeds, grapes, potatoes, cress, leaves and roots - Production of O/W and W/O emulsions - Homogenization of effluent samples liquid + sample Rotor drive Pestle Membrane Membrane fixation BMT G / S TUBE Tube for grinding with glass balls (G) or with stainless steel balls (S) 20 ml 50 ml Suitable for: - Dry milling of dry and brittle samples (e.g. kaolin, gypsum, colored pigments, tablets) - Cell maceration - Processing of materials mixed with fluids BMT G/S Tube - Decomposition of animal, plant and human cells - Dry milling of e.g. pigments, building materials and coal samples - Dry milling of freeze-dried samples - Milling of samples to determine water content balls + sample Vessel All tubes are also available with a pierceable membrane and gamma-sterilized M Tube - Sample extraction from dissolved pharmaceuticals - Addition of a reaction partner, e.g. for pigment reactions - Storage of samples in the tube, with option to remove material from the closed container at any time gamma-sterilized Tube - Homogenization of sterile samples e.g. for medical, pathology or pharmaceutical use - Storage of sterile sample material after preparation directly in sample vessel (even at temperatures down to -20 C) - Simple handling preparation of aseptic samples in the laboratory

s and Industries potato beetle 7 potatoes cherry leaves chicken, lean meat color pigments compost conductivity paste cress seeds crude oil dry frozen leaves fat cream fibrin-cells algaes amnion apple leaves brain of pigs capsules carrots catalysts cheese grape pods grass heart hop pellets ivy kidney liver lung lymph nodes malt pellets medicine analeptic muscle tissue mushrooms, dried nematode oil ointments potato shells raspberry leaves roots rosemary sage dried salad oil sediment seeds silicon carbid sludge soil samples starch grains sugar-coated tablet sunflower kernels textiles paints and pigment thymus tobacco leaves tomato seeds trachea turkey liver turkey meat umbilical cord Industries Agriculture Biology Botany Brewery Building Materials Industry Chemical Industry Cosmetics Ecology Environmental Protection Food Analysis Genetic Research Hematology Human Medicine Immunology Medicine Paint and Varnish Industry Pathology Pharmacy Petrochemistry Tobacco Industry flavor capsules food paste fruit juice concentrates fuel oil giblets grape leaves oleander leaves olives without stone orange peel vegetable vegetable mixture waste water wood Veterinary Institute pills plant leaves plant lice plums leaves IKA offers a free Hotline 1234568-00-90 Mon-Friday-8-5pm pork meat

How to work with the ULTRA-TURRAX Tube Drive System 9 Advantages STEP 1 : Dispersing of mint leaves. STEP 3 The tube is attached onto the drive system. STEP 2 The mint leaves are combined with ethanol and are placed in a DT Tube. Stir, disperse, homogenize and grind using a single drive unit No possibility of cross-contamination Hermetically sealable disposable sample tubes No cleaning required High level of user safety Suitable for individual use and use in series Gamma-sterilized tubes Tubes with pierceable membrane lids Tubes with 2 to 15 ml and 15 to 50 ml Anti-locking function Increases safety due to low voltage (24 V) Chemical-resistant plastic Simple and safe disposal Worldwide service guaranteed by IKA Reproducible tests Patented STEP 4 The dispersion is started. STEP 10 The tube is labeled and stored as a reference sample. STEP 5 The mint leaves are homogenized by the rotor-stator unit in the DT Tube. STEP 6 The dispersion is stopped. STEP 7 The tube is removed from the drive system. STEP 8 Test result: the mint leaves are dispersed homogeneously. STEP 9 If required the sample can be extracted for analysis with a syringe through the pierceable membrane of the tube lid. IKA

Questions and Answers ULTRA-TURRAX Tube Drive Workstation UTTD Workstation UTTD control Workstation 11 Included with delivery ULTRA-TURRAX Tube Drive 1 - ULTRA-TURRAX Tube Drive control - 1 ST-20 Tube with stirring device 2 2 DT-20 Tube with rotor-stator element 2 1 BMT-20 G / S Tube for grinding with glass (G) or 2 1 stainless steel balls (S) Removal hook for removal of rotor-stator element 1 1 Power supply 1 1 Ident. No. Workstation 3645000 3827500 The IKA Tubes: The IKA ULTRA-TURRAX Tube Drive: What material are the tubes made of and against which solvents are they resistant? The tubes are manufactured from polypropylene (PP), polyetheretherketone (PEEK), a thermoplastic elastomer (TPE), polyethersulfone (PES) and polyetheretherketone with teflon (PEEK + PTFE). The balls are manufactured from either stainless steel AISI 304 or soda-lime glass. All plastic materials conform to the FDA regulations. The parts have a good stability against weak acids, chlorides, hypochlorides and many other chemicals. What volumes can be processed in the tubes? Tubes are available in two sizes: 20 ml and 50 ml. The working volume range is from 2 to 50 ml. What does cross-contamination mean? Cross-contamination refers to the contamination of a sample with a second sample. For example, residue on a processing tool may be transferred into future tests. Because the UTTD tubes are closed and used only one time, cross-contamination is prevented. Can the tubes be used several times or for longer periods (> 30 min)? IKA does not recommend using tubes multiple times or for periods longer than 30 minutes. Tubes may leak and cause fluid to pass into the drive. This may lead to serious drive damage or failure. Can the balls of the BMT Tubes be used for several times? After each experiment, balls can be cleaned, sterilized and reused. Can other ball sizes and materials be used for the BMT Tubes? It is possible to use balls made of other materials with the UTTD (e.g. ceramic). The size of the balls is variable, but should not exceed a diameter of 6 mm. For cell disruption, IKA recommends using balls with a diameter < 2 mm. Can I use the UTTD for my special application? Please consult the IKA application database to see if your application has already been tested. If no similar items have been tested, you may send a sample to our test laboratory. We will be happy to test, analyze and report results directly to you. If you prefer, we will send you a demo UTTD unit to test in the privacy of your own lab. IKA provides these services at no cost to the customer. What are the advantages of the UTTD against the conventional dispersing systems? Safety: Storage: Disposable: The hermetically sealed tubes prevent the user from coming in contact with toxic or infectious samples. The tubes are used only once and can then be used for sample storage. Tubes can be discarded after one use. No time or money is wasted on expensive sterilization of a dispersing tool. Why is the reproducibility better than similar systems? Because the tests are carried out in a defined closed vessel (tube), the conditions are always identical. In addition, the test time and the speed can be precisely controlled. With the UTTD control, application programs can be stored so that the experiment conditions can be precisely duplicated. What are the benefits of the turbo and reverse buttons on the UTTD control? The turbo and reverse functions provide superior mixing and grinding effects. The additional functions provide the ability to achieve good process results with samples that are difficult to process with the basic version of the UTTD. Why can I use the tubes only once? Are the sterilized tubes really sterile? The tubes are intended for single use to prevent cross-contamination and avoid the need for cleaning. Also, the tube membrane is made of a flexible plastic which can only be exposed to high mechanical stress for a limited time. The sterilized tubes are first blister packed and then gamma sterilized. To further guarantee sterility, an expiration date is printed on the packaging. On a rotational basis, revalidation is performed to ensure the tubes are sterile in accordance with ISO 11137-1. Our Product Manager Mr. Oliver Vogelsang is happy to provide answers to your questions regarding the UTTD: Mr. Vogelsang Picture Here Tel: +49 7633 831-173 E-mail: ov@ika.de

You are optimally equipped and ready to go with the UTTD case. Subject to technical changes.