Patient Transport. with the Automated Impella Controller

Similar documents
Impella 2.5. with the Impella. Controller. Circulatory Support System. (European Union and Canada only)

MCR1900 Media Converter 19-Slot Chassis

EC-Declaration of Conformity Annex

Waveguide Access Point WGA631. Product Guide

Drayton Digistat +2RF/+3RF

FCC COMPLIANCE STATEMENT FOR AMERICAN USERS

EKOS Cart. Instructions for Use

AXIS 291 1U Video Server Rack Installation Guide

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

3500/62 Process Variable Monitor

BroadBand PowerShield. User Manual

STRATO LED Drivers 70W, Single output

Agilent 87421A/87422A Power Supply

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Scout 1U Rackmount Computer

RM4TG20 three-phase network control relay RM4-T - range V

30 In Compliance October

ST Series POWER SUPPLIES USER INSTRUCTIONS

Standards for fixed-wing ambulance aircraft and equipment. (a) Each air

MAJORSINE Power Inverter

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

How To Power A Power Supply Shelf With A Power Unit (Hp 2920)

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

Operating Manual UWAPS-TINY Series

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Telephone- and leased line modem for industrial applications TD-36

TEST REPORT EN (1997) +A1 (2001)

Cisco ASR 9001-S Router

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/2x15DC/1

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Dual Chamber Temporary External Pacemaker

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

BC Pro UPS System Standby UPS System

Rack mounted telephone- and leased line modem for industrial applications

Redundancy Module QUINT-DIODE/40

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Cisco Nexus 7000 Series Power Supply Modules

Broadband Telecommunications Drop Amplifier

Technical Data FLIR E40bx (incl. Wi-Fi)

ORION TELECOM NETWORKS INC. T1

AXIS T81B22 DC 30W Midspan

Three-phase monitoring relay CM-PFE

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

GPS Vehicle and personal location tracker. User manual

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

R&S SMZ Frequency Multiplier Specifications

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

StructureScan HD Module. Installation Guide ENGLISH

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

User s Manual Before using the inverter, you need to read and save the safety instructions.

Manual. Simrad StructureScan LSS-1 Sonar Module. English

Power Meter Series 700

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Foxboro Evo Process Automation System

EverFlo. EverFlo Q EN, DE DSF 4/16/08

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

Type: DILM32 10(24V50HZ) Article No.:

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 1

581 Rapid Transfer Device (RTD) Instruction Manual. Photo of product, with a.5 point black border

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Type: DILM50(230V50HZ,240V60HZ) Article No.:

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

TMS TANK MANAGEMENT SYSTEM

How to Self-Certify For the CE Mark A Quick Start Guide by Dennis King - EMI Test Lab

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

InnoMedia ESBC B. Quick Install Guide. 1

EMC Test for Compliance with EU EMC Directive 2004/108/EU

Preface. Manual Revisions

15 Series - Electronic step relay and dimmer. Features SERIE

Thyristor-controlled power supplies and battery chargers

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/2

I STAR COMPUTER CO., LTD

Perle Protocol Transparent Media Converter Modules

38 Series - Relay interface modules A

Type: DILM9 10(24VDC) Article No.:

Internet Office UPS System Standby UPS for PCs, workstations and more

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

Mobile Data Power Model: MDP-25

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Telex Operating Instructions

WF720 Wireless Home Phone User Manual

Dialogic I-Gate 4000 Session Bandwidth Optimizer Core

Transcription:

Patient Transport with the Automated Impella Controller

TABLE OF CONTENTS PURPOSE OF THESE INSTRUCTIONS... 2 INDICATION FOR USE... 2 FAA ADVISORY... 2 ABOUT THE IMPELLA SYSTEM... 3 PATIENT TRANSPORT WITH THE IMPELLA SYSTEM... 3 Important Considerations... 4 Battery Operation... 4 Transport with the Automated Impella Controller... 5 Securing the Automated Impella Controller... 5 TRANSFERRING SUPPORT FROM THE IMPELLA CONSOLE TO THE AUTOMATED IMPELLA CONTROLLER... 6 Receiving Hospital Preparation... 6 How to Switch Support... 7 Patient Management Checklist... 7 TRANSFERRING SUPPORT FROM THE AUTOMATED IMPELLA CONTROLLER TO THE IMPELLA CONSOLE... 8 Receiving Hospital Preparation... 8 How to Switch Support... 9 Patient Management Checklist... 9 TRANSFERRING SUPPORT FROM THE AUTOMATED IMPELLA CONTROLLER TO A NEW AUTOMATED IMPELLA CONTROLLER... 10 Receiving Hospital Preparation... 10 How to Switch Support...11 Patient Management Checklist...11 APPENDIX: ELECTRICAL SAFETY TESTING... 12 Transport with the Automated Impella Controller 1

PURPOSE OF THESE INSTRUCTIONS These instructions are designed for healthcare professionals to facilitate the safe transport of patients supported with the Automated Impella Controller from one medical facility to another. This manual contains clinical and technical information to guide healthcare professionals before, during, and after transport. INDICATION FOR USE The Automated Impella Controller and Impella Catheters have been cleared by the FDA for hospital-to-hospital transport via ambulance, helicopter, or fixed-wing aircraft. The Automated Impella Controller is qualified for safe use by healthcare professionals to facilitate the transport of patients supported by the Impella Systems from one medical facility to another. The Impella System performs lifesustaining functions. To use the system during transport you must understand and follow the Impella instructions for use. The transport team should include one person fully trained in the use of the Automated Impella Controller and Impella Catheter. FAA ADVISORY The Automated Impella Controller has been subjected to, and passed the EMC/EMI tests as specified in IEC 60601-1-2 (General requirements for safety Collateral standard: Electromagnetic compatibility Requirements and tests). Refer to the Electrical Safety Testing Appendix in this manual for more information. The Automated Impella Controller does not meet the requirements for conducted emissions of RTCA/DO-160G section 21.4 and has not been tested for radiated emissions per RTCA/DO-160G section 21.5. Abiomed recommends that air transport carriers follow the guidance FAA Advisory Circular AC No: 91-21.1B. Section 8-a of FAA Advisory Circular AC No: 91-21.1B states: Equipment tested and found to exceed the section 21, Category M, emission levels are required to be evaluated in the operator s M-PED selected model aircraft for electromagnetic interference (EMI) and radio frequency interference (RFI). All navigation, communication, engine, and flight control systems will be operating in the selected aircraft during the evaluation. 2 User Manual

ABOUT THE IMPELLA SYSTEM The Impella 2.5, 5.0, and LD are intravascular microaxial blood pumps that support a patient s circulatory system. The Impella Catheter is inserted through the femoral or axillary artery into the left ventricle or, in the case of the LD, surgically via the ascending aorta. When properly positioned, the Impella delivers blood from the inlet area, which sits inside the left ventricle, through the cannula, to the outlet opening in the ascending aorta. Users monitor the correct positioning and functioning of the Impella on the display screen of the Automated Impella Controller. PATIENT TRANSPORT WITH THE IMPELLA SYSTEM Patients are placed on the Automated Impella Controller for either partial (Impella 2.5) or full (Impella 5.0/LD) circulatory support for periods up to 6 hours. If, during this time, a patient requires additional resources and specialized teams at another location (eg, a larger facility such as a transplant center), the patient may be transferred safely to such a location using the Automated Impella Controller. Maintaining optimal patient hemodynamic status and correct Impella position are two key factors in managing patients supported with the Impella System during transport. Steps should be taken to eliminate or minimize any aspect of the transport that might adversely affect these two factors. Abiomed encourages the establishment of a relationship between outlying centers (SPOKE facilities) and tertiary-care centers (HUB facilities). Criteria for accepting patients into a program should be determined between hospitals in advance of the need for a transfer. Transport with the Automated Impella Controller 3

Important Considerations 1. Planning is critical to success. Abiomed representatives can help with planning for transport. They can be contacted 24 hours a day at 1-800-422-8666. 2. Abiomed recommends that air transport carriers follow the guidance FAA Advisory Circular AC No: 91-21.1B. 3. The Automated Impella Controller should be fully charged prior to transport. Keep the controller connected to AC power (or an AC inverter) whenever possible. 4. Do not stress the connector cable from the controller to the Impella Catheter. Such tension could move the catheter out of correct position and compromise patient circulatory support. 5. Carefully monitor purge pressures during changes in altitude. 6. The controller should be positioned to allow easy access to the display screen and soft buttons to view alarms and make any necessary changes. 7. Maintain ACTs between 160 and 180 or at the level recommended by the physician responsible for the patient. 8. If possible, place the controller and the red Impella plug at the level of the patient s heart during transport. 9. Decrease the flow rate if CPR is necessary. Battery Operation The Automated Impella Controller is designed to operate for at least 60 minutes on battery power. Transport teams should take this into consideration when planning the transport. If the total transport time is expected to include more than 60 minutes during which the system will be disconnected from AC power, arrangements should be made to use a vehicle with a built-in DC to AC power inverter. 4 User Manual

Transport with the Automated Impella Controller 1. Unplug the Automated Impella Controller from AC power. 2. Rotate the T-knobs to unlock the controller from the cart. 3. Lift the controller off the cart using the blue handle. 4. Place the controller on a flat surface (seat, bench, shelf, or stretcher) or hang the controller on the end of the stretcher using the bed mount. 5. Remove the purge solution from the IV pole on the cart and place it on the IV pole of the stretcher or transport vehicle. 6. Secure the controller. If the controller is left unsecured, it can become a dangerous projectile inside the transport vehicle or aircraft. Securing the Automated Impella Controller Options for securing the Impella System during transport will vary by transport provider. Transport providers should take into consideration their particular vehicle, stretcher design, and accessory mounting options when planning to transport a patient supported by the Impella System. 1. The Automated Impella Controller has a bed mount on the back of the housing that may be used to hang the controller on the stretcher while the patient is transported inside the hospital. 2. Straps may be used to secure the Automated Impella Controller to a flat surface in the transport vehicle. 3. The bed mount may be used as a loop through which to secure the straps. Transport with the Automated Impella Controller 5

TRANSFERRING SUPPORT FROM THE IMPELLA CONSOLE TO THE AUTOMATED IMPELLA CONTROLLER If the sending hospital uses the Impella Console (MPC), follow these steps to switch support from the Impella Console to the Automated Impella Controller before transport. This may require coordination with the receiving center to get the system to the sending hospital before transport. Receiving Hospital Preparation Gather the following items prior to switching support: 1. Automated Impella Controller 2. White connector cable 3. Purge cassette 4. Purge solution (recommended 20% dextrose with 50 IU/mL of heparin) 6 User Manual

How to Switch Support 1 Prepare 2 Switch 3 Prime A. Turn on the Automated Impella Controller. B. Open the purge cassette and spike a new bag of purge solution. C. Insert the purge cassette into the controller. D. Open the white connector cable and plug it into the controller. A. Disconnect the blue cable from the catheter. B. Connect the white cable to the catheter. C. Confirm re-starting the catheter on the controller. (The MPC system will still be purging the catheter at this point.) A. Press PURGE SYSTEM on the controller and select Change Purge Fluid. (NOTE: There may be purge alarms on the console. Continue with the purge fluid change to complete the transfer. Check the alarms once the transfer has been completed.) B. Complete the purge fluid change, making sure to flush the purge tubing. C. Disconnect the old purge tubing. D. Connect the new purge tubing. Patient Management Checklist Check each of the following once patient support has been transferred: Confirm Impella placement using echocardiography. Tighten the Tuohy bore on the Impella Catheter to prevent catheter migration. (Tighten all the way to the right) For patients supported with the Impella 2.5 Catheter, attach a saline pressure bag pressurized to 350 mmhg to the red sidearm and complete the Transfer to Standard Configuration under the PURGE SYSTEM menu. Contact the local team or the 24 hour clinical support line (1-800-422-8666) with any questions or concerns. Transport with the Automated Impella Controller 7

TRANSFERRING SUPPORT FROM THE AUTOMATED IMPELLA CONTROLLER TO THE IMPELLA CONSOLE If the receiving hospital uses the Impella Console (MPC), follow these steps to transition from the Automated Impella Controller to the Impella Console after transport. Receiving Hospital Preparation Gather the following items prior to switching support: 1. Impella Console system (Console, infusion pump, and Impella Power Supply on cart) 2. Blue connector cable 3. Grey pressure transducer cable 4. Infusion pump tubing 5. CM-Set 6. Purge solution (recommended 20% dextrose with 50 IU/mL of heparin) 8 User Manual

How to Switch Support 1 Prepare 2 Switch 3 Confirm A. Turn on the Impella Console. B. Set up the infusion pump and tubing. C. Connect the gray pressure transducer cable to the CM-Set and the Impella Console. D. Plug the blue cable into the console. E. Press PURGE SYSTEM on the Automated Impella Controller, select Change Purge Fluid, and complete the procedure to bolus the purge system. (Do NOT flush the purge fluid from the cassette). A. Disconnect the purge cassette tubing ( Purge System Open alarm will sound) B. Connect the new purge tubing and start the infusion. C. Disconnect the white cable from the Impella Catheter. D. Connect the blue cable to the Impella Catheter. A. Once the Impella Catheter is connected to the Impella Console, a message will appear on the screen asking you to confirm re-starting the Impella Catheter at the previously set performance level. B. Press OK within 10 seconds to confirm restarting the Impella Catheter. Patient Management Checklist Check each of the following once patient support has been transferred: Confirm Impella placement using echocardiography. Tighten the Tuohy bore on the Impella Catheter to prevent catheter migration. (Tighten all the way to the right) For patients supported with the Impella 2.5 Catheter, attach a saline pressure bag pressurized to 350 mmhg to the red sidearm. Contact the local team or the 24 hour clinical support line (1-800-422-8666) with any questions or concerns. Transport with the Automated Impella Controller 9

TRANSFERRING SUPPORT FROM THE AUTOMATED IMPELLA CONTROLLER TO A NEW AUTOMATED IMPELLA CONTROLLER If the receiving hospital uses the Automated Impella Controller, follow these steps to transition from the sending hospital s Automated Impella Controller to the new Automated Impella Controller after transport. Receiving Hospital Preparation Gather the following items prior to switching support: 1. Automated Impella Controller from receiving hospital 10 User Manual

How to Switch Support 1 Prepare 2 Switch 3 Confirm A. Confirm that the new controller is powered on and ready. B. Press PURGE SYSTEM on the original controller, select Change Purge Fluid, and complete the procedure to bolus the purge system. (Do NOT flush the purge fluid from the cassette). C. Disconnect the yellow luer connector from the Impella Catheter to release the pressure in the purge cassette. A. Transfer the purge cassette and purge solution from the original controller to the new controller. B. Reconnect the yellow luer connector to the Impella Catheter. C. Remove the white connector cable from the original controller and plug it into the catheter plug on the front of the new controller. A. Once the Impella Catheter is connected to the new controller, a message will appear on the screen asking you to confirm re-starting the Impella Catheter at the previously set flow rate. B. Press OK within 10 seconds to confirm restarting the Impella Catheter. Patient Management Checklist Check each of the following once patient support has been transferred: Confirm Impella placement using echocardiography. Tighten the Tuohy bore on the Impella Catheter to prevent catheter migration. (Tighten all the way to the right) For patients supported with the Impella 2.5 Catheter, attach a saline pressure bag pressurized to 350 mmhg to the red sidearm and complete the Transfer to Standard Configuration under the PURGE SYSTEM menu. Contact the local team or the 24 hour clinical support line (1-800-422-8666) with any questions or concerns. Transport with the Automated Impella Controller 11

APPENDIX: ELECTRICAL SAFETY TESTING EMI Conducted and Radiated Emissions Country or Standard Test Description 60601-1-2 Radiated emissions, 30 1000 MHz, Group 1 Class A 60601-1-2 Conducted emissions, 150 khz 30 MHz, Group 1 Class A Test Standard CISPR 11 / EN55011 CISPR 11 / EN55011 US FCC 47CFR 15C Cert Title 47 CFR Part 15 Subpart C Intentional Radiator EU EU ETSI EN300-330-1 V1.5.1 (2006-04) ETSI EN300-330-2 V1.3.1 (2006-04) V1.5.1 (EMC) &(ERM); (SRD); Radio Equip. in the Frequency Range 9 KHz to 25 MHz and Inductive Loop Systems in the Frequency Range 9 KHz to 30 MHz; Part 1: Technical Characteristics and Test Methods V1.3.1 (EMC)& (ERM); Short Range Devices (SRD); Radio Equipment in the Frequency Range 9 KHz to 25 MHz and Inductive Loop Systems in the Frequency Range 9 KHz to 30 MHz; Part 2 EU ETSI EN 301 489-1 Issued: 2007/04/01 EU ETSI EN 301 489-3 Issued: 2002/08/01 Canada RSS 210 Issue: 7 June 2007 A2.6 V1.7.1 Electromagnetic compatibility and Radio spectrum Matters (ERM);Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common Technical Requirements V1.4.1 (ERM) & (EMC) Standard for Radio Equipment and Services; Part 3: Specific Conditions for Short-Range Devices (SRD) Operating on Frequencies between 9 KHz and 40 GHz Low Power License Exempt Radiocommunication Devices (All Frequency Bands) Canada RSS-GEN Issue: 2 June 2007 General Requirements and Information for the Certification of Radiocommunication Equipment 12 User Manual

EMC Tests and Standards IEC 60601-1-2 Test Description Test Standard Harmonic current emissions; Class A IEC 61000-3-2 Limitation of voltage fluctuations and flicker IEC 61000-3-3 Electromagnetic radiated field immunity IEC 61000-4-3 Electromagnetic conducted field immunity IEC 61000-4-6 Voltage dips and interruptions on AC power mains IEC 61000-4-11 Magnetic fields immunity IEC 61000-4-8 Electrically fast transients on AC power mains IEC 61000-4-4 Surge on AC power mains IEC 61000-4-5 Electrostatic discharge IEC 61000-4-2 Review of EMC identification, markings and documents Section 6 Transport with the Automated Impella Controller 13

Parameter Temperature Automated Impella Controller Electrical Specifications Specification Operating: 10 C to 40 C (50 F to 104 F) Storage: -15 C to 50 C (5 F to 122 F) Relative humidity Operating: 95% Storage: 95% Atmospheric pressure Dimensions Weight Maintenance and repair interval AC operation Internal battery operation Characteristic values Electrical system Operating: 8000 ft (750 hpa) to -1000 ft (1050 hpa) Storage: 18,000 ft (500 hpa) to -1000 ft (1050 hpa) Height: 351 mm (13.8 in), Width: 443 mm (17.4 in), Depth: 236 mm (9.3 in) Maximum: 11.8 kg (26.1 lbs) 12 months (work must be performed by technicians authorized by Abiomed) 100-230 V AC (nominal); 47-63 Hz; 1.1 A 14.4 V DC (nominal); lithium ion Max. power consumption under load 120 VA 9.7 fuses; 2 Amp. 250 V. 5 mm x 20 mm, slow blow fuses Run time without AC power (full charged batteries) 60 minutes minimum (charging duration of at least 5 hours) Installation in accordance with pertinent regulations is required for use in medical facilities (eg, VDE 0100, VDE 0107, or ICE stipulations). Observe country-specific regulations and national deviations. Clinical support 24 hours per day, 7 days a week: 1-800-422-8666 (US) +49 (0) 1805 2246633 (EU) www.abiomed.com Abiomed, Inc. 22 Cherry Hill Drive Danvers, Massachusetts 01923 USA Voice: 978-777-5410 Facsimile: 978-777-8411 Email: marketing@abiomed.com Abiomed Europe GmbH Neuenhofer Weg 3 52074 Aachen, Germany Voice: +49 (241) 8860-0 Facsimile: +49 (241) 8860-111 Email: europe@abiomed.com 2011 Abiomed, Inc. All rights reserved. The ABIOMED logo and ABIOMED are registered trademarks of Abiomed, Inc. in the U.S.A. and certain foreign countries. Recovering hearts. Saving lives. is a trademark of Abiomed, Inc. Impella is a registered trademark of Abiomed Europe GmbH, a wholly owned subsidiary of Abiomed, Inc., in the U.S.A. and certain foreign countries. December 2011 HCS-PM-1211-0267-0 0086