Pore size and BET surface area. analysis at your fingertips. SA 3100. Gas Adsorption Analyzer



Similar documents
FINESORB Surface Area. as or more than m 2 /g. Distribution of Pore nm. Degas & Analysis Up to 12 Degas & 6 Analysis Station

PHYSISORPTION DETERMINATIONS

ASAP Accelerated Surface Area and

TriStar II Surface Area and Porosity Analyzer

Texture characteristic of membrane materials ASAP, BET

BET Surface Area Analysis of Nanoparticles

Analytical Services. Part number Measurement Description. Single-Point BET with Nitrogen N. Multi-Point BET With Nitrogen N

The PMI Advanced. BET SORPTOMETER BET-201-AELC-2OS Not just products...solutions!

TriStar II Surface Area and Porosity System. The Science and Technology of Small Particles

EXPERIMENTAL METHODS IN COLLOIDS AND SURFACES

Standard Test Methods for Carbon Black Surface Area by Multipoint B.E.T. Nitrogen Adsorption 1

Surface Area and Porosity

Adsorption. December 2014

presented by Neal Leddy CMA Analytical Workshop 2012 SURFACE AREA AND POROSITY

Physical Chemistry Practical Course, Oxford University. Determination of the Surface Area of Alumina by Nitrogen Adsorption at 77K (4 points)

Pharmaceutical Physical Characterization: Surface Area and Porosity

Keysight Technologies How to Choose your MAC Lever. Technical Overview

Appendix A. Fig. 1 Nitrogen adsorption for Activated Carbon from Norit

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index

Motivation Physisorption Chemisorption Outlook

ADSORPTION OF N2 ON SILICA GEL

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

Agilent 4339B/4349B High Resistance Meters

INSTALLATION AND OPERATION OF AUTOSORB-l-C-8 FOR BET SURFACE AREA MEASUREMENT OF POROUS MATERIALS

Weight Loss Determined from Mass Spectrometry Trend Data in a Thermogravimetric/Mass Spectrometer System

[ Care and Use Manual ]

This document is a preview generated by EVS

ProteinChip Energy Absorbing Molecules (EAM)

(S&G 5th ed. Expt 27, 6th, 7th & 8th eds. Expt 26)

Effect of surface area, pore volume and particle size of P25 titania on the phase transformation of anatase to rutile

1.5 GHz Active Probe TAP1500 Datasheet

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID

Micromeritics BET Surface Area and Porosity Analyzer Instrument Information and Generalized Standard Operating Procedure

Agilent Automotive Power Window Regulator Testing. Application Note

Low Temperature Adsorption Versus Pore Size in Activated Carbons

Development of porous materials for hydrogen storage

Use the BET (after Brunauer, Emmett and Teller) equation is used to give specific surface area from the adsorption

Thermo Scientific ConFlo IV Universal Interface

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Agilent 4338B Milliohm Meter

Supporting Information

Agilent Television Power Consumption Testing. Application Note

Integrating CaliberRM with Software Configuration Management Tools

Microsoft Voucher Ordering Processes

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

Industrial Robotics Solutions

Computer Specifications

Reducing Cycle Times and Work in Process Management Costs: Aerospace and Defense Industry

10 Reasons to Choose Image-based ID Readers. White Paper

Image Lab Software for the GS-900 Densitometer

MILESTONE H E L P I N G C H E M I S T S

PROCESS PARTICLE COUNTER (PPC) SENSOR/CONTROLLER FOR OPTIMIZING POWER RECOVERY EXPANDER AND GAS TURBINE PERFORMANCE

Keeping ahead through Claisse expertise in sample preparation by fusion. Safe, simple, high performance

White Paper. 10 Reasons to Choose Image-based Barcode Readers

Hydrogen Adsorption on Nanoporous Biocarbon

ab vacuum manifold for 96 well filter plates This product is for research use only and is not intended for diagnostic use.

Barcode Labeling in the Lab Closing the Loop of Patient Safety

still different technique of assessment.

ISO INTERNATIONAL STANDARD

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

Heterogeneous Catalysis and Catalytic Processes Prof. K. K. Pant Department of Chemical Engineering Indian Institute of Technology, Delhi

TORKEL 820 Battery Load Unit

INSITE. Dimension Data s monitoring offering

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

DMA-1 Direct Mercury Analyzer

Adsorption and Catalysis

CNE Progress Chart (CNE Certification Requirements and Test Numbers) (updated 18 October 2000)

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

PRODUCT DATA. PULSE WorkFlow Manager Type 7756

Understanding European versus U.S. temperature code ratings for solenoidoperated. A White Paper From ASCO

XFA 600 Thermal Diffusivity Thermal Conductivity

Characterization of Gas Shale Pore Systems by Analyzing Low Pressure Nitrogen Adsorption

CHROMOCTANE O N LINE ANALYZER

Inspired Partnership. Software Support Directed by You

Derivation of the BET and Langmuir Isotherms

Customer Support. Superior Service Solutions for Your Laser and Laser Accessories. Superior Reliability & Performance

Particle testing in cleanroom high-pressure gas lines to ISO made easy with the MET ONE 3400 gas calibrations

Toxicity. Toxicity monitoring technologies for on line, on location and the laboratory

AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes

OCTOBER Russell-Parametric Cross-Sectional Volatility (CrossVol ) Indexes Construction and Methodology

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

ORGANIC SAMPLE PREPARATION

Agilent P940xA/C Solid State PIN Diode Switches

Multi Tube Rotator. Model No. 4632Q CE CECN /05/11

The Global Chemical Industry: US, China and Global Status and Opportunities, 2015

PCI Express 1.0 (2.5 GT/s) Protocol Test

HFM Heat Flow Meter Thermal Conductivity Analyzer

Supporting Information

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Accuracy counts! SENSORS WITH ANALOG OUTPUT

CASE STUDY. Environnement S.A. Industrial Site Noise Monitoring

Agilent Cary 60 UV-Vis

CASE STUDY. Automotive Components. Bosch Drancy, France Brake NVH Testing. Braking Systems. France. Automotive. PULSE, Transducers

Surface Parameters of Stannic Oxide in Powder, Ceramic and Gel Forms by Nitrogen Adsorption Techniques l

POLLUTED EMISSION TREATMENTS FROM INCINERATOR GASES

A Complete Solution for Method Linearity in HPLC and UHPLC

Transcription:

Pore size and BET surface area analysis at your fingertips. SA 3100 Gas Adsorption Analyzer

The History of Beckman Coulter Particle Characterization Introducing The SA 3100 Surface Area and Pore Size Analyzer A complete solution for characterizing the surface of solid materials. The SA 3100 utilizes the well-established gas adsorption technique to measure the surface area and porosity of solids. Everything you need is incorporated into one powerful and easy-to-use package. With an internal PC and flexible software, the SA 3100 gives you the information you need: BET and Langmuir surface area, BJH Adsorption and Desorption, Pore Size Distribution, t-plot, total pore volume and more. Data is displayed in real-time on the easy-to-read touch screen. Plus, the SA-View Windows viewing software allows you to view, print and archive your data. Whether you are in a quality control or R&D environment, the SA 3100 is the most versatile and easy-to-use gas adsorption analyzer available today. For over 40 years the Particle Characterization Group (PCG) of Beckman Coulter has provided answers and solutions to those involved in the testing and measurement of the physical properties of particles. Offering a complete family of instruments, including: History of Innovation Coulter Counters 1954 Pore Characterization Analyzers 1975 Photon Correlation Spectroscopy Analyzers 1983 Zeta Potential Analyzers 1988 Laser Diffraction Analyzers 1989 Surface Area/BET Analyzers 1993 Digital Pulse Processing 1999 Image Analyzers 2000 We are in a unique position to offer solutions for most particle analysis needs. World-class support, including being listed as an ASTM certified laboratory and with service only a company such as Beckman Coulter can provide. Purchasing an instrument from us will deliver performance, versatility and peace of mind. The Beckman Coulter Technology Center

Designed with The Technology the user in mind. The gas adsorption technique is performed Taking ease-of-use to a new level. by the addition of a known volume of gas (adsorbate), typically nitrogen, to a solid material in a sample vessel at cryogenic temperatures. At cryogenic temperatures, weak molecular An innovative touch screen allows easy control of all instrument functions without the use of an external computer. A completely integrated, fully automated system allows for true walk-away analysis. Intuitive software prompts the user each step of the way. Using the latest technology to achieve maximum speed of analysis. Intelligent Learn function decreases analysis time of routine samples by referencing stored sample isotherms. Novel sample tube design minimizes equilibration time. attractive forces will cause the gas molecules to adsorb onto (attach to the surface of) a solid material. An adsorbate (gas) is added to the sample in a series of controlled doses, the pressure in the sample vessel is measured after each dosing. There is a direct relationship between the pressure and the volume of gas in the sample vessel. By measuring the reduced pressure due to adsorption, the Concurrent manifold dosing during sample equilibration eliminates unnecessary delays. Combining versatility, accuracy and power for a complete solution. A Sample Port, three degassing ports, a powerful CPU, vacuum pump and automated dewar lift are all integrated into a single unit. Nitrogen, Argon or Krypton adsorbate gases can be used to meet your application needs. Exceptional Accuracy is achieved by referencing the true saturation vapor pressure for each data point. ideal gas law can then be used to determine the volume of gas adsorbed by the sample. The resulting relationship of volume of gas adsorbed vs. relative pressure at constant temperature is known as an adsorption Isotherm. From the analysis, and the cross-sectional area of the adsorbate gas molecule, the surface area and pore size distribution of the sample can be derived. The SA-Prep Surface Area Outgas Station For customers who need extra capacity Prepare up to 6 samples simultaneously Flow degassing with Nitrogen, Argon or Helium Temperature range from ambient to 400 C

Sample Analysis Has never been so simple. The User-defined Sample Profiles make using the SA 3100 incredibly simple. Choose a profile and you can produce results quickly, accurately and easily. Running samples is as easy as... 1 1 Load your prepared sample in the analysis position. 2 2 Select a profile. 33 View your results in minutes. The SA 3100 utilizes a totally self-contained vacuum system. Easy to read screen complete with simple touch pad operation. Sample pre-treatment or outgassing is completely internal. No additional outgassing apparatus is required. Sample outgassing is done concurrently with sample analysis. Automated Dewar Lift for walk-away operation.

Software The SA-View data archiving and viewing software gives you the flexibility you need. Drop-down menus and toolbars let you view all aspects of your data, the way you want to see it, quickly and easily. Is reproducibility important to you? The overlay function lets you compare data from run to run, instrument to instrument, or last year and today. Print reports directly from the SA 3100 or from the SA-View software. The choice is yours. View isotherms, data tables, BET plots and more, from one or several samples, at a glance. Applications Adhesives Alloys Abrasives Carbonates Carbons Catalysts Cements Ceramics Clays Cosmetics Detergents Explosives and Ordnance Fibers Films Fertilizers Filters Glass Food Additives Graphite Metal Powders Minerals Paper Pharmaceuticals Pigments Polishing Compounds Polymers Resins Soils and Sediments

WORLDCLASS GLOBAL SUPPORT AUSTRALIA (61) 2 9844 6000 GERMANY (49) 2151 333 625 MEXICO (52) 5 559 1635 SWEDEN (46) 8 564 85900 CANADA (1) 905 819 1234 HONG KONG (852) 2814 7431 NETHERLANDS (31) 2972 30630 SWITZERLAND 0800 850 810 CHINA (86) 10 6515 6028 ITALY (39) 2 25221 SINGAPORE (65) 3393633 TAIWAN (886) 2 2378 3456 EASTERN EUROPE, MIDDLE EAST AND AFRICA (41) 22 994 0707 FRANCE (33) 1 49 909083 JAPAN (81) 3 5404 8359 LATIN AMERICA (1) (305) 380-3810 SOUTH AFRICA (27) 11 805 2014 / 5 SPAIN (34) 91 728 7900 UNITED KINGDOM (44) 1494 429162 UNITED STATES (1) 800-523-3713 Visit our web site: www.beckmancoulter.com TECHNICAL SPECIFICATIONS SURFACE AREA MEASUREMENT RANGE SPECIFIC SURFACE AREA RANGE: From >0.01 m 2 /g PORE SIZE RANGE MESOPORE SIZE DISTRIBUTION RANGE: 3 to 200 nm MICROPORE VOLUME AND AREA BET SURFACE AREA TYPICAL REPRODUCIBILITY: <2% CV PRESSURE MEASUREMENT OVERALL PRESSURE RANGE: Vacuum to 1000 mm Hg MINIMUM RELATIVE PRESSURE: 6 x 10-5 SAMPLE PRESSURE RESOLUTION: 0.046 mm Hg TRANSDUCER LINEARITY: <0.1% BFSL TRANSDUCER REPEATABILITY: 0.0125% BFSL CALIBRATED MANIFOLD TEMPERATURE AT: 45 C Stability ± 0.1 C VACUUM PUMP VOLUME RATE DISPLACEMENT: 1.5 m 3 /hr POWER CONSUMPTION: 130W ULTIMATE VACUUM: 10-3 mm Hg SAMPLE PREPARATION SYSTEM NUMBER OF OUTGAS PORTS: 3 FURNACE SPECIFICATIONS TEMPERATURE Range: 30 to 350 C Settability: 1 C Stability: 5 C Accuracy: ±5 C ENVIRONMENTAL AND POWER REQUIREMENTS UNIVERSAL ONE-DESIGN: Autoswitch power supply, 90-250 Volts 50/60 Hz. 150W OPERATIONAL POWER CONSUMPTION: Nominally 500W OPERATING TEMP. RANGE: 10-35 C STORAGE TEMP.: 0-50 C OPERATING ALTITUDE: up to 10,000 ft. above MSL OPERATING/STORAGE RELATIVE HUMIDITY: 10-85% RH non-condensing GAS REQUIREMENTS GAS PURITY: Helium 99.995% Absorbates 99.9% (or better) DIMENSIONS 71.1 cm (21 ) height x 50.8 cm (20 ) width x 53.3 cm (21 ) depth WEIGHT: 80 lbs. with vacuum pump COULTER, COULTER COUNTER, Beckman Coulter are registered trademarks of Beckman Coulter Inc. Copyright 2000 Beckman Coulter Inc. All rights reserved. Specifications subject to change without notice. MS Windows is a registered trademark of Microsoft Corp. P/N: 7221500 RevC