PowerChute TM Network Shutdown Operating Modes and supported UPS Configurations



Similar documents
PowerChute TM Network Shutdown in Redundant UPS Configurations

Setting up PowerChute Network Shutdown Version 4.0 for advanced configuration.

How To Shut Down A Powerchute On A Hyperv V3.2.2 (Powerchute) On A Powerpack V3 (Powerchip) On An Uniden V3 On A Pc Or Mac (Powercheute)

PowerChute Network Shutdown v4.1 Release Notes

PowerChute Network Shutdown v4.0. Installation Guide. Windows Linux/Unix Mac OS X Hyper-V/SCVMM VMware

PowerChute TM Network Shutdown Security Features & Deployment

Title Page Web/SNMP Management SmartSlot Card

Ambient Temperature In Range Probe X

USER S GUIDE. network management card. Contents. Introduction--1. Control Console--13

Network Management Card

Network Management Card. Installation and Quick Start Manual

Installation Guide. PowerChute Network Shutdown v4.1 Windows Linux/Unix Mac OS X Hyper-V/SCVMM VMware K /2015

How To Log On Main Screen Control Console Menus... 19

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

USER S GUIDE. network management card. Contents. Introduction--1. Control Console--13

Smart-UPS On-Line 230 V

PowerPanel Business Edition Installation Guide

Configurable Events for APC Network Management Card

Dell Smart-UPS 1,500 3,000 VA

Citrix XenServer 5.6 OpenSource Xen 2.6 on RHEL 5 OpenSource Xen 3.2 on Debian 5.0(Lenny)

User s Guide. UPS Network Management Card 2 AP9630, AP9631

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

1. Installing and configuring APC UPS Management

Network Management Card Security Implementation

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Network Management Card

Microsoft Windows Built-In Serial and USB UPS Support

Configuring Security for FTP Traffic

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

Configuring Network Load Balancing with Cerberus FTP Server

Central Administration QuickStart Guide

Eaton NetWatch v5.0 NetWatch on Microsoft Hyper-V server 2008 Installation and configuration guide

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

Upgrading Your Skills to MCSA Windows Server 2012

Firmware upgrade instructions for the Web/SNMP and Network

Coyote Point Systems White Paper

Network Management Card. User Manual

Configuring the Cisco SPA9000 Voice System with the Cyberdata VoIP Intercom for Door Bell Applications

Tripp Lite PowerAlert

Ignify ecommerce. Item Requirements Notes

How To Create An Easybelle History Database On A Microsoft Powerbook (Windows)

Evaluating the Balabit Shell Control Box

Table of Contents Introduction and System Requirements 9 Installing VMware Server 35

StruxureWare Data Center Expert Release Notes

Using Intelligent Power Manager (IPM) & Intelligent Power Protector (IPP) on Virtual Desktop Infrastructure (VDI)

PN5212/PN5320/PN7212/PN7320

Fortinet Network Security NSE4 test questions and answers:

13.1 Backup virtual machines running on VMware ESXi / ESX Server

SGI NAS. Quick Start Guide a

- 1 - SmartStor Cloud Web Admin Manual

StruxureWare Data Center Expert Release Notes

Communication and connectivity the ideal solution for integrated system management and data integrity

vrealize Air Compliance OVA Installation and Deployment Guide

Using ESXi with PowerChute Business Edition

SETTING UP ACTIVE DIRECTORY (AD) ON WINDOWS 2008 FOR EROOM

5 Easy Steps to Implementing Application Load Balancing for Non-Stop Availability and Higher Performance

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

Using SonicWALL NetExtender to Access FTP Servers

Network-Enabled Devices, AOS v.5.x.x. Content and Purpose of This Guide...1 User Management...2 Types of user accounts2

Darstellung Unterschied ZyNOS Firmware Version 4.02 => 4.03

OnCommand Performance Manager 1.1

Introducing Tripp Lite s PowerAlert Network Management Software

Deployment Topologies - DPAdmin An isoagroup Product

WW HMI SCADA-08 Remote Desktop Services Best Practices

APC UPS Management Solutions

Virtual Managment Appliance Setup Guide

VMware vcenter Log Insight Security Guide

RT5kVA and RT6kVA 3U Rack or Tower Uninterruptible Power Supplies Product Guide

Configuration Network Management Card-2

Windows Server 2008 Hyper-V, Windows Server 2008 Server Core Installation Notes

CNS-208 Citrix NetScaler 10.5 Essentials for ACE Migration

Installing and Using the vnios Trial

Konica Minolta s Optimised Print Services (OPS)

vsphere Upgrade vsphere 6.0 EN

Virtual Web Appliance Setup Guide

WhatsUp Gold v16.3 Installation and Configuration Guide

Emerald. Network Collector Version 4.0. Emerald Management Suite IEA Software, Inc.

Netwatch Installation For Windows

Owner of the content within this article is Written by Marc Grote

UPS Monitoring Software. User manual Borri Power Guardian

Build Your Knowledge!

Lab Configure Basic AP Security through IOS CLI

Bosch Video Management System High Availability with Hyper-V

Remote Monitoring Service - Setup Guide for InfraStruXure Central and StruxureWare 1 5

For protection from laptops to high availability facilities - and everything in between - APC is a partner you can count on

UPS Monitoring Software User Manual. Emily2

MIGRATING TO AVALANCHE 5.0 WITH MS SQL SERVER

Implementing and Managing Windows Server 2008 Hyper-V

Installing and Configuring vcenter Support Assistant

T1kVA and T1.5kVA Tower Uninterruptible Power Supplies Product Guide

Contents Notice to Users

Simplifying power management in virtualized data centers

Upgrading Your Skills to MCSA Windows Server 2012

Server Software Installation Guide

Installing and Configuring vcenter Multi-Hypervisor Manager

TESTING & INTEGRATION GROUP SOLUTION GUIDE

CenterMind P+ Solution for efficient power management

Transcription:

[APPLICATION NOTE #170] PowerChute TM Network Shutdown Operating Modes and supported UPS Configurations By Sarah Jane Hannon ABSTRACT PowerChute TM Network Shutdown software works in conjunction with the UPS Network Management Card to provide graceful, unattended shutdown of multiple computer systems over a network. This Application Note describes each supported UPS configuration and lists the UPS families that support each configuration. Lastly, a table summarizing which UPS Network Management Card supports which UPS model for each configuration is provided. APPLICATIONS IT Server Rooms, Data Centers, Remote Branch Offices, Distributed Networks. CUSTOMER BENEFITS Graceful network-based shutdown Sequenced server shutdown Integration with VMware & Hyper-V Support for virtual clusters Virtual machine migration/shutdown Intuitive PowerChute setup wizard Browser accessible Command file integration Redundant & Parallel UPS support Event logging HTTPS communications IPv6 support Introduction You can configure PowerChute Network Shutdown to operate in several different modes or configurations as follows: Single UPS configuration Redundant UPS configuration Parallel UPS configuration Advanced UPS configuration Note: From PowerChute Network Shutdown v4.0, all UPS configurations support virtual clusters and virtual machine migration. This is to facilitate the migration of virtual machines across geographic locations.

Single-UPS Configuration In a Single-UPS configuration, each server or group of servers is protected by a single UPS. Each server has one PowerChute Network Shutdown Agent communicating with a single NMC inserted in the UPS. This single UPS provides the full power capacity of the load for all connected servers. When an event that requires shutdown occurs, PowerChute Network Shutdown triggers a safe system shutdown command for all connected server(s). Figure 1 Single UPS Configuration Supported UPS s All Smart-UPS models with a SmartSlot (including Smart-UPS VT), the Galaxy 300 (3:1 & 3:3), Galaxy 3500 (3:1 & 3:3), the Galaxy 5000, Galaxy 7000, Symmetra 1-Phase, Symmetra 3-Phase and Symmetra PX. 2

Redundant UPS Configuration In a Redundant-UPS Configuration, PowerChute Network Shutdown recognizes a group of up to four UPS s as a single UPS system. In this configuration, one PowerChute Network Shutdown Agent on a server communicates with up to four NMCs (depending on the number of UPS s in the configuration). Typically, the servers have multiple (dual or triple) power cords. Each UPS has its own NMC, which has a unique IP address. In addition, all the NMCs use the same HTTP port and the same administrator user name and authentication phrase. Each UPS has the capacity to supply power to the load on its own. The first UPS provides all the power for the load, the additional UPS(s) act as reserve. The UPS s have to be the same model type and each UPS must have enough battery power to support the system during a power outage. This configuration may have either two or three UPS s. Figure 2 Redundant UPS configuration Recommendation: Please read Application Note #98 (AN-98) Using PowerChute Network Shutdown in a Redundant-UPS Configuration for further information including event handling in different shutdown scenarios. Supported UPS s All Smart-UPS models with a SmartSlot (including Smart-UPS VT), Galaxy 3500 (3:1 & 3:3), Symmetra 1-Phase and Symmetra 3-Phase. 3

[APPLICATION NOTE #170] Operating Modes and Supported UPS Configurations Parallel-UPS Configuration In a Parallel-UPS Configuration, two or more UPS s (up to nine depending on the model) support the load. Each UPS does not need to be capable of supporting the load on its own as the combined output of all UPS s in the configuration can share the load. However, depending on the size of the load there may be reserve UPS(s) available. Redundancy is provided if there is at least one more UPS than is required to support the load. An example of a Parallel Redundant Configuration is if three 5kVA UPS s are supporting an 8kVA server load; one of the three UPS s can fail and the load can still be supported by the remaining two UPS s. A Parallel Capacity Configuration exists if three 5kVA UPS s are supporting a 13kVA bank of servers. All three UPS s are required to continue supporting this load. In this configuration, you have one PowerChute Network Shutdown Agent on a server communicating with several Network Management Cards (NMC) installed on UPS s which have already been configured to operate in parallel mode. Each UPS has its own NMC, which has a unique IP address. In addition, all the NMCs use the same HTTP port and the same administrator user name and authentication phrase. PowerChute Network Shutdown recognizes that the UPS s are set-up in a Parallel configuration and will monitor the changing load on the UPS s (as a single device) so the software can modify how the events are aggregated depending on the level of redundancy in the system at any given time. All UPS s in a Parallel-UPS configuration must be of the same UPS family (model and firmware version). Figure 3 Parallel UPS Configuration Set-Up Recommendation: Please read Application Note #169 (AN-169) Using PowerChute Network Shutdown in Parallel Redundant or Parallel Capacity UPS Configurations for further information including event handling in different shutdown scenarios. Supported UPS s Smart-UPS VT (Parallel-Capable), Galaxy 300 (3:1 & 3:3), Galaxy 3500 (3:1 & 3:3), Galaxy 5000, Galaxy 7000, Symmetra PX 250 and Symmetra PX 500. For information on using a Parallel Silcon UPS system, please read the following: http://www.apcmedia.com/salestools/pmar- 78JCEG_R0_EN.pdf 4

Advanced UPS Configuration Supported UPS Models PowerChute Network Shutdown v4.0 has introduced a new Advanced UPS configuration which enables a single PowerChute Agent to monitor multiple UPS setups and initiate graceful shutdown based on different redundancy levels. Each UPS setup can be a single UPS or a UPS group of 2 or more UPS s. For example, one UPS setup may be a group of UPS s with N+2 redundancy while another setup may be a single UPS. All Smart-UPS models with a SmartSlot (including Smart-UPS VT), the Galaxy 300 (3:1 & 3:3), Galaxy 3500 (3:1 & 3:3), the Galaxy 5000, Galaxy 7000, Symmetra 1-Phase, Symmetra 3- Phase and Symmetra PX. For details on configuring Advanced Redundant Setups, please see the Using PowerChute Network Shutdown in Advanced Redundant Setups Application Note. Figure 4 Advanced UPS Configuration Set-Up Recommendation: Please see the Application Note Using PowerChute Network Shutdown in an Advanced Redundant Setup for further information and details on different advanced redundant setups. 5

UPS Network Management Cards & UPS Configurations UPS Configuration UPS Model UPS Network Management Card All Smart-UPS models with a SmartSlot AP9630 / AP9630CH Smart-UPS VT Models AP9631 / AP9631CH Galaxy 3500 (3:1 & 3:3) AP9617*, AP9618*, AP9619* Symmetra 1-Phase Symmetra 3-Phase Symmetra PX (excluding PX 250 & 500) *Does not support Next Generation UPS models (e.g. SMX, SMT, SRT Smart-UPS) Single and Advanced Galaxy 300 (3:1 & 3:3) Galaxy 7000 AP9630CH Galaxy 5000 Symmetra PX 250 Symmetra PX 500 Silcon DP3500E & Silcon BC3 (Single UPS AP9617, AP9618, AP9619 Configuration only). All Smart-UPS models with a SmartSlot AP9630 / AP9630CH Redundant Parallel Smart-UPS VT Models Galaxy 3500 (3:1 & 3:3) Symmetra 1-Phase Symmetra 3-Phase Smart-UPS VT (Parallel Capable Models) Galaxy 3500 (3:1 & 3:3) Galaxy 300 (3:1 & 3:3) Galaxy 7000 Galaxy 5000 Symmetra PX 250 Symmetra PX 500 Silcon DP3500E & Silcon BC3 AP9631 / AP9631CH AP9617*, AP9618*, AP9619* *Does not support Next Generation UPS models (e.g. SMX, SMT, SRT Smart-UPS) AP9630 / AP9630CH AP9631 / AP9631CH AP9630CH AP9617, AP9618, AP9619 6