Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.

Similar documents
LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

Low Profile Unit Cooler

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS

CARRIER REFRIGERATION EQUIPMENT AND PARTS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Installation Manual CLIFC Fan & Coil Variable Speed

PRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS

MAC-120HE-01 Air-Cooled Chiller

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Contents and Nomenclature

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

ARMSTRONG AIR HEAT PUMPS

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

CB29M Bulletin # February 1996

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Cased/Uncased Coils For Gas And Oil Furnaces

Local Dealer:

NSN

KRAMER ELECTRIC DEFROST EVAPORATORS LPE - LVE - MSE - CSE - HSE - CED - KED INSTALLATION, START-UP AND MAINTENANCE INSTRUCTIONS

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Defining Quality. Building Comfort. Heating and Cooling Coils

SECTION HEAT PUMPS

Dehumidification Frequently Asked Questions

IV. Rear Mount System

Slim Contour Unit Cooler

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

HP switch LP switch Discharge thermo Comp. Surface thermo

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Why Daikin? 2015 Houston, Texas USA

SECTION MORTUARY REFRIGERATORS

Slim Line KUC Unit Coolers 60Hz

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Morgue refrigeration unit

How To Understand Evaporator

KONRAD. Hybrid Fancoil Series

HEAVY DUTY STORAGE GAS

AIR-COOLED CONDENSERS Technical Guide

SP H/M/L AFLR /1464/ /1469/ /22/ AFLR /8 1468/1209/ /6050/ /31/28 115

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

catalog Single Package Vertical Air Conditioners and Heat Pumps

Atlas Copco Stationary air compressors

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

A. Section includes air conditioning units, controls and control panels.

C26 Bulletin # November 1997 Supersedes January 1997 (Coil/Furnace Match Up Charts)

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Commercial Portable Air Conditioners

SPLIT-SYSTEM CONDENSING UNITS SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES

SMALL DUCT HIGH VELOCITY COMFORT SYSTEM

Evaluate, Clean, and Tune Guidance

CHILLED WATER DATA ROOM UNITS

ECOCIAT. Domestic hot water heat recovery unit

SECTION AIR CONDITIONING UNIT

THE PSEUDO SINGLE ROW RADIATOR DESIGN

SWIMMING POOL HEAT PUMP

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

Automobile Air Conditioning Primer

Cooling/Heat Pump Convertible Air Handlers

Accumulators and Receivers

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

marine/bespoke split applications

Explosion-Proof Electric Unit Heaters

REGULATORS 175/153 Series

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

Commercial Gas Furnace Upflow

Split System Heat Pump Product Data

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

CEILING CASSETTE FAN COIL UNIT

Split System Cooling Product Data

Split System Heat Pump Product Data

REFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:

Controlled Environment Products & Commercial Refrigeration Price List

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

Product Data. Features/Benefits. AquaForce 30XA Air-Cooled Liquid Chillers. 80 to 500 Nominal Tons (265 to 1740 Nominal kw)

REFRIGERATED COMPRESSED AIR DRYERS

National Grid Small Business Energy Efficiency Program Overview. Central New York Energy Expo March 30, 2010

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Element D Services Heating, Ventilating, and Air Conditioning

ROOF TOP MOUNTED Air Handler Specification

BB-18 Black Body High Vacuum System Technical Description

AMERICAN SOLAR WATER HEATING SYSTEM The Best Water Heating Solution Under The Sun

Split System Cooling Product Data

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Glossary of Heating, Ventilation and Air Conditioning Terms

3Aftermarket Systems. Air Conditioners and Kombos Heater/Pressurizer System Matrix Aftermarket System Requirements...

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

Refrigerated. Fred C. Gilbert Co. 106 Norris Road Bakersfield, Ca fax

Product Data. Split System Cooling F-EN. March 2015

Transcription:

COMPACT UNIT FOR CEILING OR WALL MOUNT Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain. MJ-40 400 600 7 13 5/8 8 125 5 1/4" 0.65 0.35 3/8" OD 3/8" OD 1/2" OD 7 MJ-70 700 1050 7 13 5/8 8 125 51/4" 0.65 0.35 3/8" OD 3/8" OD 1/2" OD 9 MJ-90 900 1350 7 13 5/8 9 125 5 1/4" 0.65 0.35 3/8" OD 3/8" OD 1/2" OD 10 MJ-120 1200 1800 7 20 5/8 9 250 5 1/4 (2) 1.3 0.7 3/8" OD 3/8" OD 1/2" OD 15 PEERLITE protective coated coils designated by a "-P" after model number TEXTURED ALUMINUM CABINET Fan Dia. Motor Amps ECM Motor Amps Connections 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V 115 V 230 V Inlet Suction Drain SF-105 1000 1500 9 11 3/8 14 300 8" 0.73 0.45 0.30 0.15 3/8" OD 3/8" OD 1/2" OD 14 SF-135 1300 1950 9 14 3/8 14 300 8" 0.73 0.45 0.30 0.15 3/8" OD 3/8" OD 1/2" OD 16 SF-175 1700 2550 9 17 3/8 14 300 8" 0.73 0.45 0.30 0.15 3/8" OD 3/8" OD 1/2" OD 18 SF-235 2300 3450 9 7/8 20 3/8 15 300 8" 0.73 0.45 0.30 0.15 3/8" OD 1/2" OD 1/2" OD 22 SF-305+ 3000 4500 11 23 3/8 16 500 10" 0.75 0.45 0.60 0.30 1/2" OD 1/2" OD 1/2" OD 27 + External equalized expansion valve recommended. (External equalizer tube field installed) Optional EC motors designated with a *A model number suffix. Approx.

Fan Dia. Motor Amps ECM Motor Amps Connections 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V 115 V 230 V Inlet Suction Drain LS-55 550 825 5 10 14 125 5 1/4" 0.65 0.35 N/A N/A 3/8" OD 1/2" OD 1/2" OD 9 LS-105 1050 1575 5 16 1/2 14 125 5 1/4" 0.65 0.35 N/A N/A 3/8" OD 1/2" OD 1/2" OD 12 LS-135 1350 2025 5 20 1/2 14 200 5 1/4" (2) 1.46 0.90 N/A N/A 3/8" OD 1/2" OD 1/2" OD 16 LS-180 1800 2700 5 24 1/2 15 225 5 1/4 (2) 1.46 0.90 N/A N/A 3/8" OD 1/2" OD 1/2" OD 17 LS-240+ 2400 3600 6 5/8 24 16 1/2 300 8" 0.73 0.45 0.30 0.15 1/2" OD 1/2" OD 1/2" OD 23 LS-310+ 3100 4650 8 30 5/8 20 3/8 400 10" 0.73 0.45 0.60 0.30 1/2" OD 5/8" OD 5/8" MF 36 LS-400+ 4000 6000 7 1/2 38 18 1/4 600 8" (2) 1.46 0.90 0.60 0.30 1/2" OD 5/8" OD 5/8" MF 44 + External equalized expansion valve recommended. (External equalizer tube field installed) Approx. TEXTURED ALUMINUM CABINET Fan Dia. Motor Amps 115 V 230V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V 115 V 230 V 115 V 230 V 115 V 230 V Inlet Suction Drain + External equalized expansion valve recommended. (External equalizer tube field installed) Optional EC motors designated with a *A model number suffix. ECM Motor Amps Heaters Amps Heaters Watts Connections Approx. LS50E1 LS50E2 500 750 5 10 14 125 5 1/4" 0.65 0.35 N/A N/A 1.80 0.95 215 215 3/8" OD 1/2" OD 1/2" OD 10 LS95E1 LS95E2 950 1425 5 16 1/2 14 125 5 1/4" 0.65 0.35 N/A N/A 4.20 1.74 480 400 3/8" OD 1/2" OD 1/2" OD 13 LS125E1 LS125E2 1250 1875 5 20 1/2 14 200 5 1/4" (2) 1.3 0.7 N/A N/A 4.31 2.16 495 495 3/8" OD 1/2" OD 1/2" OD 17 LS160E1 LS160E2 1600 2400 5 24 1/2 15 225 5 1/4 (2) 1.3 0.7 N/A N/A 5.05 2.52 580 580 3/8" OD 1/2" OD 1/2" OD 19 LS210E1+ LS210E2+ 2100 3150 6 5/8 24 16 1/2 300 8" 0.73 0.45 0.3 0.15 7.52 3.83 865 880 1/2" OD 1/2" OD 1/2" OD 24 LS280E1+ LS280E2+ 2800 4200 8 30 5/8 20 3/8 400 10" 0.73 0.45 0.6 0.3 9.80 4.90 1125 1125 1/2" OD 5/8" OD 5/8" MF 38 LS360E2+ 3600 5400 7 1/2 38 18 1/4 600 8" (2) 0.9 0.6 0.3 6.10 1400 1/2" OD 5/8" OD 5/8" MF 47 LS540E2+ 5400 8100 7 1/2 50 18 1/4 800 8" (3) 1.35 0.9 0.45 8.00 1850 1/2" OD 5/8" OD 5/8" MF 145

TWO WAY AIR DISCHARGE FOR UNIFORM BOX TEMPERATURE Fan Dia. Motor Amps ECM Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V 115 V 230 V Inlet Suction Drain. TM-100 1000 1500 4 5/8 20 3/8 16 125 5 1/4" 0.65 0.30 N/A N/A 3/8" OD 3/8" OD 1/2" OD 11 TM-135 1350 2025 4 5/8 20 3/8 16 250 51/4" (2) 1.30 0.60 N/A N/A 3/8" OD 3/8" OD 1/2" OD 15 TM-180 1800 2700 4 5/8 20 3/8 16 250 51/4" (2) 1.30 0.60 N/A N/A 3/8" OD 3/8" OD 1/2" OD 15 TM-250 2500 3750 5 5/8 20 3/8 16 300 8" 0.73 0.45 0.30 0.15 3/8" OD 3/8" OD 1/2" OD 16 TM-350 3500 5250 5 5/8 20 3/8 16 300 8" 0.73 0.45 0.30 0.15 3/8" OD 3/8" OD 1/2" OD 16 Optional EC motors designated with a *A model number suffix. TEXTURED ALUMINUM CABINET PEERLESS EXCLUSIVE PIE PLATE COIL CONSTRUCTION AVAILABLE WITHOUT DRAIN PAN (S MODEL) OR WITH DRAIN PAN (D MODEL) Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain. P-82S 850 1275 8 7/8 8 7/8 4 1/2 150 8" 0.73 0.45 3/8" OD 3/8" OD - 7 P-83S 1100 1650 8 7/8 8 7/8 5 1/2 150 8" 0.73 0.45 3/8" OD 3/8" OD - 9 P-103S 1350 2025 10 7/8 10 7/8 5 1/2 200 10" 0.73 0.45 3/8" OD 3/8" OD - 12 P-104S 1600 2400 10 7/8 10 7/8 6 1/2 200 10" 0.73 0.45 3/8" OD 3/8" OD - 14 P-82D 850 1275 9 1/2 9 1/2 8 1/8 150 8" 0.73 0.45 3/8" OD 3/8" OD 1/2" OD 9 P-83D 1100 1650 9 1/2 9 1/2 8 1/8 150 8" 0.73 0.45 3/8" OD 3/8" OD 1/2" OD 10 P-103D 1350 2025 11 1/2 11 1/2 8 1/8 200 10" 0.73 0.45 3/8" OD 3/8" OD 1/2" OD 13 P-104D 1600 2400 11 1/2 11 1/2 8 1/8 200 10" 0.73 0.45 3/8" OD 3/8" OD 1/2" OD 15

TWO WAY AIR DISCHARGE FOR UNIFORM BOX TEMPERATURE PEERLESS EXCLUSIVE PIE PLATE COIL CONSTRUCTION LOUVERED PANEL EASILY REMOVABLE FOR EASY SERVICING Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain. TP-82D 1500 2250 9 1/2 16 9 1/2 300 8" (2) 1.00 0.50 1/2" OD 3/8" OD 1/2" OD 18 TP-83D 2000 3000 9 1/2 18 9 1/2 300 8" (2) 1.00 0.50 1/2" OD 3/8" OD 1/2" OD 20 TP-84D 2500 3750 9 1/2 20 9 1/2 300 8" (2) 1.00 0.50 1/2" OD 3/8" OD 1/2" OD 24 TP-103D 3000 4500 11 1/2 18 11 1/2 400 10" (2) 1.00 0.50 1/2" OD 3/8" OD 1/2" OD 26 TEXTURED ALUMINUM CABINET IDEAL FOR HIGH HUMIDITY APPLICATIONS REQUIRING LOW AIR VELOCITY TWO WAY AIR DISCHARGE FOR UNIFORM BOX TEMPERATURE LARGE CAPACITY UNIT BUILT FOR CEILING MOUNT THERMALLY PROTECTED, PERMANENTLY LUBRICATED EC MOTORS Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain. HJ-500 5000 7500 10 4/8 54 29 7/8 600 10" 0.6 0.3 1/2" OD 7/8" O.D. 1" FPT 102 HJ-750 7500 11250 10 4/8 54 29 7/8 600 10" 0.6 0.3 1/2" OD 7/8" O.D. 1" FPT 104 HJ-1000 10000 15000 13 76 29 7/8 1200 10" (2) 1.2 0.6 1/2" OD 7/8" O.D. 1" FPT 128 HJ-1250 12500 18750 13 76 29 7/8 1200 10" (2) 1.2 0.6 1/2" OD 7/8" O.D. 1" FPT 155 HJ-1550 15500 23250 15 4/8 76 29 7/8 1200 10" (2) 1.2 0.6 7/8" OD 1-1/8" O.D. 1" FPT 200 HJ-1800 18000 27000 15 4/8 76 29 7/8 1800 10" (3) 1.8 0.9 7/8" OD 1-1/8" O.D. 1" FPT 235 HJ-2100 21000 31500 15 4/8 98 29 7/8 2400 10" (4) 2.4 1.2 7/8" OD 1-1/8" O.D. 1" FPT 255 HJ-2700 27000 40500 15 4/8 98 29 7/8 2400 10" (4) 2.4 1.2 7/8" OD 1-1/8" O.D. 1" FPT 267 EC motors designated with a *A model number suffix.

REMOVABLE SIDE PANEL & HINGED DRAIN PAN Fan Dia. Motor Amps ECM Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V 115 V 230 V Inlet Suction Drain PLP-380 3800 4560 13 1/2 22 1/2 12 1/4 600 10" 0.75 0.45 0.60 0.30 1/2" OD 5/8" O.D. 1" FPT 35 PLP-500 5000 6000 13 1/2 27 12 1/4 600 10" 0.75 0.45 0.60 0.30 1/2" OD 7/8" O.D. 1" FPT 38 PLP-600 6000 7200 13 1/2 33 12 1/4 600 10" 0.75 0.45 0.60 0.30 1/2" OD 7/8" O.D. 1" FPT 46 PLP-750 7500 9000 13 1/2 38 12 1/4 1200 10" (2) 1.50 0.90 1.20 0.60 1/2" OD 7/8" O.D. 1" FPT 55 PLP-900 9000 10800 13 1/2 45 12 1/4 1200 10" (2) 1.50 0.90 1.20 0.60 1/2" OD 7/8" O.D. 1" FPT 64 PLP-1000 10000 12000 13 1/2 45 12 1/4 1200 10" (2) 1.50 0.90 1.20 0.60 1/2" OD 7/8" O.D. 1" FPT 67 PLP-1250 12500 15000 13 1/2 54 12 1/4 1200 10" (2) 1.50 0.90 1.20 0.60 1/2" OD 7/8" O.D. 1" FPT 81 PLP-1500 15000 18000 13 1/2 63 12 1/4 1800 10" (3) 2.25 1.35 1.80 0.90 1/2" OD 7/8" O.D. 1" FPT 90 PLP-1750 17500 21000 13 1/2 72 12 1/4 1800 10" (3) 2.25 1.35 1.80 0.90 1/2" OD 7/8" O.D. 1" FPT 99 PLP-2000 20000 24000 13 1/2 81 12 1/4 2400 10" (4) 3.00 1.80 2.40 1.20 1/2" OD 1-1/8" O.D. 1" FPT 120 PLP-2500 25000 30000 13 1/2 99 12 1/4 3000 10" (5) 3.75 2.25 3.00 1.50 1/2" OD 1-1/8" O.D. 1" FPT 155 PLP-3000 30000 36000 13 1/2 117 12 1/4 3600 10" (6) 4.50 2.70 3.60 1.80 1/2" OD 1-1/8" O.D. 1" FPT 180 Optional EC motors designated with a *A model number suffix. Externally equalized expansion valves required - ¼ tube provided. BUILT FOR LOW TEMPERATURE WALK-IN STORAGE ROOMS ELECTRIC DEFROST WITH DEFROST TERMINATION AND FAN DELAY CONTROL REMOVABLE SIDE PANEL & HINGED DRAIN PAN Model No. +20 F (SST) BTU/HR 10 TD -10 F -20 F (SST) (SST) Dimensions (Inches) PSC ECM Heaters Connections Approx. -30 F (SST) H W D CFM Fan Dia. (Quantity) Motor Amps Motor Amps Amps Watts Inlet Suction Drain PLP-430E 5000 4400 4300 4000 13 1/2 27 12 1/4 600 10" 0.45 0.30 4.48 1030 1/2" OD 5/8" O.D. 1" FPT 38 PLP-640E 7500 6600 6500 5900 13 1/2 38 12 1/4 1200 10" (2) 0.90 0.60 6.24 1435 1/2" OD 7/8" O.D. 1" FPT 55 PLP-760E 9000 7900 7700 7100 13 1/2 45 12 1/4 1200 10" (2) 0.90 0.60 7.24 1665 1/2" OD 7/8" O.D. 1" FPT 61 PLP-860E 10000 8800 8600 7900 13 1/2 45 12 1/4 1200 10" (2) 0.90 0.60 7.24 1665 1/2" OD 7/8" O.D. 1" FPT 67 PLP-1070E 12500 11000 10800 9900 13 1/2 54 12 1/4 1200 10" (2) 0.90 0.60 9.95 2253 1/2" OD 7/8" O.D. 1" FPT 80 PLP-1290E 15000 13200 12900 11900 13 1/2 63 12 1/4 1800 10" (3) 1.35 0.90 12.35 2840 1/2" OD 7/8" O.D. 1" FPT 90 PLP-1560E 17500 15400 15100 13800 13 1/2 72 12 1/4 1800 10" (3) 1.35 0.90 14.41 3308 1/2" OD 7/8" O.D. 1" FPT 105 PLP-1720E 20000 17600 17200 15800 13 1/2 81 12 1/4 2400 10" (4) 1.80 1.20 16.41 3775 1/2" OD 1-1/8" O.D. 1" FPT 120 PLP-2150E 25000 22000 21500 19800 13 1/2 99 12 1/4 3000 10" (5) 2.25 1.50 18.84 4330 1/2" OD 1-1/8" O.D. 1" FPT 155 PLP-2580E 30000 26400 25800 23700 13 1/2 117 12 1/4 3600 10" (6) 2.70 1.80 21.20 4875 1/2" OD 1-1/8" O.D. 1" FPT 180 (230/60/1) EC motors designated with a *A model number suffix. Externally equalized expansion valves required - ¼ tube provided.

PATTERN 3/8" PLATE FIN 3/8" PLATE FIN 3/8" OFF CENTER 1/2" PLATE FIN 5/8" OFF CENTER TUBE OD NOMINAL 3/8" 3/8" 3/8" 1/2" 5/8" TUBE SPACING 1" 1" 1" 1.25" 1.5" ROW SPACING.866" 1" 1" 1.083" 1" OR 1.5" FIN EDGE RIPPLED STRAIGHT STRAIGHT RIPPLED STRAIGHT FIN SURFACE CORRUGATED FLAT FLAT CORRUGATED FLAT FINS PER INCH 6-16 4-10 2-10 6-12 2-6 FIN THICKNESS 0.0075-0.013 0.0075-0.013 0.013 0.0075 0.02 TUBE WALL THICKNESS.016 Smooth.013 Rifled.016 Smooth.013 Rifled.016 Smooth.025 Smooth.016 Smooth.016 Smooth ENDPLATE MATERIAL Galv. / Alum. Galv. / Alum. Galv. / Alum. Galv. / Alum. Galv. / Alum. ALUMINUM EVAPORATOR COILS FOR FROST-FREE COMMERCIAL AND HOUSEHOLD REFRIGERATOR APPLICATIONS ALUMINUM COILS CAN BE PROVIDED WITH COPPER TIPS JOINED WITH PEERLESS PATENTED EUTECTIC JOINT OR FLUXLESS SOLDER JOINT

FOR AFTER-COOLER OR OIL-COOLER APPLICATIONS All ALUMINUM CONSTRUCTION FOR CORROSION RESISTANCE AND REDUCED WEIGHT FIN AND TUBE DESIGNED TO WITHSTAND THE MOST RUGGED CONDITIONS WHILE PROVIDING MAXIMUM EFFICIENCY AVAILABLE IN 3/8, 5/8 AND 3/4 OD TUBING PEERLITE PROTECTIVE COATING AVALIABLE INTEGRAL FIN-TO-TUBE HEAT TRANSFER PRODUCT FABRICATED FROM SOLID OR MULTIPORT ALUMINUM EXTRUSIONS BY THE PEERLESS SKYVE/FIN PROCESS EXTREMELY DURABLE CONSTRUCTION WITH VERY EFFICIENT HEAT TRANSFER USED IN AUTOMOTIVE, COMMERCIAL REFRIGERATION, AEROSPACE AND HEAVY EQUIPMENT REFRIGERATION AND OIL COOLER APPLICATIONS VARIOUS FIN SPACING AVAILABLE CAN BE FABRICATED INTO A VARIETY OF SHAPES OR SUPPLIED IN STRAIGHT LENGTHS UP TO 30 FEET PEERLITE PROTECTIVE COATING OPTIONAL CAPABILITIES ALLOYS TEMPERS 1100 F 1050/1435 F 1060 F 3003 F 3102 F 6063 F 3065 F OTHER ALLOYS SUBJECT TO INQUIRY ROUND TUBING MIN OD MIN WALL MAX OD MAX WALL MICRO-MULTIPORT TUBE.100 OR < HEIGHT MACRO-MULTIPORT TUBE 1 UP TO 4 1/2 SINGLE VOID HOLLOW TUBE 1 UP TO 4 1/2 1/4 OD -.020 WALL 7/8 OD -.080 WALL (LARGER UPON REQUEST).020 OR < WEB AND WALL >.020 WEB AND WALL >.025 WALL

1201 W. Wabash Ave. Effingham, IL 62401 Ph: (217) 342-0400 Fax: (217) 342-0412 Email: sales@peerlessofamerica.com Web: www.peerlessofamerica.com July 2009