Refrigerated Design Texas Refrigerated Design Texas 1808 FM 66 / P.O. Box 622 Waxahachie, TX 75167 / 75168 Toll Free (800) 736-9518 Ph. (972) 937-3215 Fax (972) 937-0970 www.rdtonline.com
Table of Contents RDT Welcome.................................................. 3 CHDSS / ZS Outdoor Air-Cooled Line.............................. 4 RDDC Outdoor Air-Cooled Line................................... 7 RDMC Outdoor Dual Compressor Line.............................. 8 RDPL Indoor Parallel Line........................................ 10 IRW Indoor Water-Cooled Line.................................... 12 IRP Indoor Air-Cooled Line....................................... 14 Evaporator Coil Information...................................... 16 Technical Data: ADT / LET Evaporator Coils......................... 17 Technical Data: SM / SME Evaporator Coils......................... 18 RDT Facilities.................................................. 19 2
Refrigerated Design Texas Message from the President: The consideration you are extending to RDT is greatly appreciated. Our place in the industry has been enhanced by the personal relationships we have acquired through the years. We have been in the business for 38 years, with a majority of that time devoted to the design and build of refrigerated products. We have seen compressors, refrigerants, and controls come and go. Many new innovations have advanced our industry and we are honored to be a part of a rapidly expanding technology that becomes more interesting everyday. We are constantly in search of ways to better our product. We tailor our efforts toward what gives you a longer lasting and more economical product. Believe it or not, both can be achieved to a great degree. RDT is committed to protecting your interest. That is how we got here and that is how we intend to stay. We have enjoyed the confidence placed in us by so many and fully intend to continue earning your trust. My family, my associates, and all of us here at RDT thank you for your unwavering support. We will always be here to see to your needs. Sincerely, Randall Dyess President 3
Models CHDSS / ZS Designed for Maximum Dependability and Service 1/4 hp ball bearing fan motors provide years upon years of run time. Our unit includes heavy duty blades and OSHA approved fan guards. Note: CHDSS1-2 Shown Entire weather cover 304 brushed stainless steel. This unit is designed with no external fasteners and no unfinished corners to provide years of operation. RDT s modular base design allows individual units to be exchanged as needed. RDT utilizes the reliable Copeland Copelametic semi-hermetic Compressors (on the CHDSS model line). RDT utilizes the latest technology. Copeland Glacier Scroll Compressors (on the ZS model line). All welded sight glass and drier CHDSS / ZS St Outdoor Air Cooled Stainless Steel Housing Dedicated Condenser Up 4
Refrigerated Design Texas Oversized individual condenser designed for high ambient summer temperatures. Stainless steel hail guards protect units from any type of abuse. RDT provides its customers with pre-piped suction and liquid lines. Optional Pre-Wired Fused Disconnect RDT provides lifting eyes on all four corners of our unit. UL approved stainless steel electrical enclosure Individual Square D Breaker for each compressor. Solid state defrost clock eliminates mechanical gears and springs. Johnson Micro Set Controls with stainless steel super-hose ar Components Defrost Contactor locks out until compressor pumps down, eliminating erroneous breaker trips. Please Note: Technical Data on Page 6 to 5 Compressors (One Tier) and 10 Compressors (Two Tier) Proven Performance 5
Models CHDSS / ZS TECHNICAL DATA Medium Temperature Compressors 208-230/60/3*** SEMI-HERMETIC SCROLL EVAPORATOR COILS* MODEL HP RLA** MODEL HP RLA** HAG2-0050 0.50 4.3 ADT-040 / SM-052 - - - KAN1-0075 0.75 5.4 ADT-070 / SM-076 - - - KAM1-0100 1.0 6.4 ADT-104 / SM-102 ZB10KCE 1.3 11.9 KAGA-0150 1.5 7.4 ADT-120 / SM--134 ZB11K4E 1.5 11.9 KAKA-0200 2.0 8.7 ADT-156 / SM-156 ZB13KCE 2.0 14.8 ERF1-0311 3.0 14.3 (2) ADT-130 / (2) SM-134 ZF09K4E 3.0 13.0 NRB2-0400 4.0 25.6 (2) ADT-180/ (2) SM-208 ZF13K4E 4.0 18.8 - - - (2) ADT-260 / (2) SM-249 ZF15K4E 5.0 25.2 Low Temperature Compressors 208-230/60/3 SEMI-HERMETIC SCROLL EVAPORATOR COILS* MODEL HP RLA** MODEL HP RLA** KAJA-011E 1 6.5 LET-040 - - - KALA-016E 1.5 8.5 LET-065 - - - EAVA-021E 2.0 9.3 LET-090 ZF06K4E 2.0 11.2 LAHA-032E 3.0 14.7 LET-120 / LET-140 ZF11K4E 3.5 15.5 2DF3-030E 3.0 18.7 LET-180 ZF15K4E 5.0 25.2 2DL3-040E 4.0 30.1 LET-240 / (2)LET-120 ZF18K4E 6.0 27.7 2DA3-060E 6.0 32.6 LET-280 / (2) LET-140 ZF24K4E 7.5 34.7 - - - (2) LET-180 ZF33K4E 10.0 48.7 - - - (2) LET-240 ZF40K4E 13.0 58.2 *The Last Three Digits of the Evaporator Coil Number Designates BTU s in Hundreds. For More Information About Evaporator Coils, see page 16. **The RLA s Listed Here Include Condenser Fan Motors. ***The ZB10KCE, ZB11KCE, and ZB13KCE are 208-230/60/1. 6
Refrigerated Design Texas Model RDDC Designed for Heavy Duty Use RDT s Electrical Panel combines all electrical elements in one, easy-toaccess location. Ball Bearing fan motors provide years upon years of run time. Our RDDC unit includes heavy duty blades and OSHA approved fan guards. Each RDDC is finished in a 304 Stainless Steel Housing. Each unit features head cooling fans to keep the low temperature compressors cool and allow them to operate at maximum efficiency. Each RDDC utilizes the latest in Copeland Discus Compressors Each RDDC features a louvered front that provides ventilation, easy compressor access and a clean look. Each RDT unit provides lifting eyes on all four corners for easy unit placement. Compressor Data 60 Hz, 3 Phase Compressor Data 60 Hz, 3 Phase R-22 Med. Temp. +25º BTU Rated Figure Comp. HP 208-230V Amperage 460V Amperage R-404a Low Temp. -20º BTU Rated Figure Comp. HP 208-230V Amperage 460V Amperage 3DB3A1000 104,000 10.0 43.6 20.0 3DF3A1200 122,000 12.0 48.2 23.6 3DS3A1500 138,000 15.0 59.6 29.0 4DA3-2000 148,000 20.0 66.0 33.0 4DH3-2500 193,000 25.0 82.2 41.1 4DJ3-3000 226,000 30.0 94.0 47.0 6DH3-3500 276,000 35.0 107.0 53.5 6DJ3-4000 335,000 40.0 142.0 71.0 3DS3A100E 49,900 10.0 42.0 18.6 4DA3-101E 51,500 10.1 45.2 22.6 4DL3-150E 68,600 15.0 52.6 26.3 4DT3-220E 81,800 22.0 66.0 33.0 6DL3-270E 102,200 27.0 80.8 40.4 6DT3-300E 114,100 30.0 95.6 47.8 Please Note: More configurations are available. Amperages do not include condenser fan motors. Please consult RDT directly for the latest information. Outdoor Air Cooled Dual Compressor Reliable Time-Tested Performance 7
MODEL RDMC MEDIUM TEMP COMPRESSORS 208-230/60/3*** SCROLL SEMI-HERMETIC MODEL HP RLA** MODEL HP RLA** EVAPORATOR COILS* - - - KAN1-0075 0.75 3.5 ADT-070 / SM-076 - - - KAM1-0100 1.0 4.5 ADT-104 / SM-102 ZB10KCE 1.3 10.0 KAGA-0150 1.5 5.5 ADT-120 / SM--134 ZB13KCE 2.0 12.9 KAKA-0200 2.0 6.8 ADT-156 / SM-156 ZF09K4E 3.0 11.1 ERF1-0311 3.0 12.4 (2) ADT-130 / (2) SM-134 ZF13K4E 4.0 15.0 NRB2-0400 4.0 21.8 (2) ADT-180 / (2) SM-208 *The Last Three Digits of the Evaporator Coil Number Designate the BTU s in Hundreds. For More Information About Evaporator Coils, see page 16. **RLA s Do Not Include Evaporator Fan Motor. ***The ZB10KCE and ZB13KCE are 208-230/60/1. NOTE: For More System Options, Please Contact RDT Directly. The RDMC now supports up allowing more flexibility Standard Features: All Stainless Steel Housing Stainless Steel One Piece Louvers Factory Pre-Piped and Pre-Wired Ball Bearing Fan Motor Low Ambient Control System Rugged Base, Tubular Steel, Polyurethane Painted Fresh Air Over Compressors One Point Electrical Electric Defrost Pre-Wired Time Clocks Compressor Lock Out During Defrost Cycle Stainless Steel Super Hose Connections Micro Set Dual Pressure Control Multi-Circuited Condenser and Oversized Receiver Aluminum Fin Copper Tube Condenser Crankcase Heater Suction Filter Sight Glass, Drier, Liquid Line Valve (All Welded) OSHA Approved Fan Guard Outdoor Air Cooled Vertical 8
Refrigerated Design Texas Designed for Maximum Dependability and Service LOW TEMP COMPRESSORS 208-230/60/3 SCROLL SEMI-HERMETIC MODEL HP RLA** MODEL HP RLA** EVAPORATOR COILS* - - - KALA-016E 1.5 6.6 LET-065 ZF06K4E 2.0 9.3 EAVA-021E 2.0 7.4 LET-090 ZF11K4E 3.5 13.6 LAHA-032E 3.0 12.8 LET-120 / LET-140 ZF15K4E 5.0 21.4 2DF3-030E 3.0 16.8 LET-180 ZF18K4E 6.0 23.9 2DL3-040E 4.0 26.3 (2) LET-120 ZF24K4E 7.5 30.9 2DA3-060E 6.0 28.8 (2) LET-140 to 15 compressors, on larger jobs. *The Last Three Digits of the Evaporator Coil Number Designate the BTU s in Hundreds. For More Information About Evaporator Coils, see page 16. **RLA s Do Not Include Evaporator Fan Motor. NOTE: For More System Options, Please Contact RDT Directly. Optional Features: Copeland Glacier Scroll Compressor Technology (Please Consult Factory for Latest Information) Fused Disconnect Suction Accumulator Oil Separator Air Flow Multi-Circuited 9
Model RDPL Liquid Line Solenoids Evaporator Pressure Regulator Diagnostic Centers sound an alarm if any of the following are detected: compressor overload, low liquid refrigerant level in the receiver, low oil pressure, or high system head pressure. They can operate audible or visible in-store alarms, or can automatically phone a service location. Complete Manifold System - Pre-Piped and mounted with temperature control, electric solenoid and service valve as needed Additional Standard Features: R-404a Low Temperature. R-22 Medium Temperature. Heavy-Gauge Welded Steel Frame Primed and Painted with two (2) Coats of Polyurethane. Receiver With Relief Valve and Liquid Level Indicator. UL Listed and Labeled Pre-Wired Control Panels Feature a Single-Point Electrical Connection, Individually Fused Circuits with Toggle Switches, Definite Purpose Contactors, and Breakers. Oil Float and Return System On Dual Uneven And Three or More Compressor Systems. Compressors may be Even or Uneven Horsepowers, with Satellites; Up to Six Compressors on a Single System. Head Fans Provided on All Low-Temperature Compressors. Stainless Steel Super Hose Connection R-404a Low Temp. -20º Sentronic Oil Switch Large Capacity, Oversize Receiver - For remote condenser operation Compressor Data BTU Rated Figure Comp. HP 60 Hz, 3 Phase 208-230V Amperage 460V Amperage 2DL3-040E 21,800 4.0 26.3 10.2 2DA3-060E 25,200 6.0 28.8 10.2 3DB3A075E 36,200 7.5 31.5 16.1 3DF3A090E 44,200 9.0 39 16.9 3DS3A100E 49,900 10.0 42.0 18.6 4DL3-150E 68,600 15.0 52.6 26.3 4DT3-220E 81,800 22.0 66.0 33.0 6DT3-300E 114,100 30.0 95.6 47.8 The RDPL is RDT s Su R-22 Med. Temp. +25º Compressor Data BTU Rated Figure Comp HP 2DC3-0500 43,300 5.0 2DL3-0750 63,800 7.5 3DA3A0750 87,500 7.5 3DB3A1000 104,000 10.0 3DS3A1500 138,000 15.0 4DA3-2000 148,000 20.0 4DH3-2500 193,000 25.0 4DJ3-3000 226,000 30.0 6DH3-3500 276,000 35.0 6DJ3-4000 335,000 40.0 Parallel System Allows One Compressor to 10
Refrigerated Design Texas Pre-Wired Defrost Panel (Where Electric Defrost Is Required) Designed for Maximum Capacity and Versatility Oil Reservoir Suction Accumulator - Prevents Flood Back Liquid Site Glass Oil Separator - Assures adequate oil supply under varying load conditions Replaceable Core Suction Filter Optional Features: R-22 Low Temp. With Demand Cooling Remote Air Cooled Condensers, Water Cooled, Evaporator Cooled Replaceable Core Liquid Filter Drier perior Parallel System 60 Hz, 3 Phase. 208-230V Amperage 460V Amperage 22.3 10.4 31.6 13.8 41.0 20.0 43.6 20.0 59.6 29.0 66.0 33.0 82.2 41.1 94.0 47.0 107.0 53.5 142.0 71.0 R-22 Low Temp. with Demand Cooling -20º Percentage Liquid Level Indicator - For quick, accurate reference of refrigerant charge, with an optional alarm (can be in communication package) Compressor Data BTU Rated Figure Comp. HP 60 Hz, 3 Phase 208-230V Amperage 460V Amperage 2DF3-0300 15,000 3.0 16.8 8.1 2DA3-0600 21,300 6.0 28.8 10.2 3DB3A0750 26,000 7.5 31.5 16.1 3DS3A1000 42,100 10.0 42.0 18.6 4DL3-1500 58,400 15.0 52.6 26.3 4DT3-2200 69,600 22.0 66.0 33.0 6DT3-3000 104,100 30.0 95.6 47.8 Please Note: More configurations are available. Please contact the factory directly for the latest information. NOTE: Dimensions of Racks Conform to the Number of Compressors. Height Is 72 on Most Applications. Front-to-Back Dimensions will be 40, with 30 Length Required per Compressor. (Example: A 3-Compressor Rack would be 40 X 90 X 72 ) Run Multiple Evaporator Coils 11
MODEL IRW MEDIUM TEMP COMPRESSORS 208-230/60/3** SCROLL SEMI-HERMETIC MODEL HP RLA MODEL HP RLA EVAPORATOR COILS* - - - KAN1-0075 0.75 3.5 ADT-070 / SM-076 ZB10KCE 1.3 10.0 KAM1-0100 1.0 4.5 ADT-104 / SM-102 ZB11KCE 1.3 10.0 KAGA-0150 1.5 5.5 ADT-120 / SM--134 ZB13KCE 2.0 12.9 KAKA-0200 2.0 6.8 ADT-156 / SM-156 ZF09K4E 3.0 11.1 ERF1-0311 3.0 12.4 (2) ADT-130 / (2) SM-134 ZF13K4E 4.0 15.0 NRB2-0400 4.0 21.8 (2) ADT-180/ (2) SM-208 *The Last Three Digits of the Evaporator Coil Number Designates BTU s in Hundreds. For More Information About Evaporator Coils, see page 16. **The ZB10KCE, ZB11KCE, and ZB13KCE are 208-230/60/1. NOTE: For More System Options, Please Contact RDT Directly. The IRW is RDT s Indoor Water Standard Features: Micro Set Dual Pressure Control Stainless Steel Super Hose Connections Individual Oversized Condenser Circuit and Receiver One Point Electrical Electric Defrost Pre-Wired Time Clocks Compressor Lock Out During Defrost Cycle Pre-Piped To Common Supply and Return Header Adjustable Water Regulators Vibration Eliminator for Quiet Leak-Free Operation Sight Glass Drier Suction Filter Inlet and Outlet Rotolock Valves Strong Structural Steel Rack Indoor Water Cooled 12
Refrigerated Design Texas Designed for Maximum Dependability and Service LOW TEMP COMPRESSORS 208-230/60/3 SCROLL SEMI- EVAPORATOR COILS* HERMETIC MODEL HP RLA MODEL HP RLA - - - KALA-016E 1.5 6.6 LET-065 ZF06K4E 2.0 9.3 EAVA-021E 2.0 7.4 LET-090 ZF11K4E 3.5 13.6 LAHA-032E 3.0 12.8 LET-120 / LET-140 ZF15K4E 5.0 21.4 2DF3-030E 3.0 16.8 LET-180 ZF18K4E 6.0 23.9 2DL3-040E 4.0 26.3 (2)LET-120 ZF24K4E 7.5 30.9 2DA3-060E 6.0 28.8 (2) LET-140 Cooled Refrigeration System * The Last Three Digits of the Evaporator Coil Number Designates BTU s in Hundreds. For More Information About Evaporator Coils, see page 16. NOTE: For More System Options, Please Contact RDT Directly. Optional Features: Fused Disconnect Suction Accumulator Oil Separator Pre-Piped Crankcase Pressure Regulator Rack Can Be Expanded To Accommodate Up To Ten Units Rack can be Two-Tier to allow for space conservation. Quiet Design 13
MODEL IRP MEDIUM TEMP COMPRESSORS 208-230/60/3*** SCROLL SEMI-HERMETIC MODEL HP RLA** MODEL HP RLA** EVAPORATOR COILS* - - - KAN1-0075 0.75 5.4 ADT-070 / SM-076 ZB10KCE 1.3 11.9 KAM1-0100 1.0 6.4 ADT-104 / SM-102 ZB11KCE 1.5 11.9 KAGA-0150 1.5 7.4 ADT-120 / SM--134 ZB13KCE 2.0 14.8 KAKA-0200 2.0 8.7 ADT-156 / SM-156 ZF09K4E 3.0 13.0 ERF1-0311 3.0 14.3 (2) ADT-130 / (2) SM-134 ZF13K4E 4.0 18.8 NRB2-0400 4.0 25.6 (2) ADT-180/ (2) SM-208 *The Last Three Digits of the Evaporator Coil Number Designates BTU s in Hundreds. For More Information About Evaporator Coils, see page 16. **The RLA s Listed Here Include Condenser Fan Motors. ***The ZB10KCE, ZB11KCE, and ZB13KCE are 208-230/60/1. NOTE: For More System Options, Please Contact RDT Directly. The IRP is RDT s Indoor air - dedicated condens e Standard Features: Factory Pre-Piped and Pre-Wired Ball Bearing Fan Motor Low Ambient Control System Rugged Base, Tubular Steel, Polyurethane Painted One Point Electrical Electric Defrost Pre-Wired Time Clocks Compressor Lock Out During Defrost Cycle Stainless Steel Super Hose Connections Micro Set Dual Pressure Control Multi-Circuited Condenser and Oversized Receiver Aluminum Fin Copper Tube Condenser Suction Filter Sight Glass, Drier, Liquid Line Valve (All Welded) OSHA Approved Fan Guard RDT s Indoor 14
Refrigerated Design Texas Designed for Maximum Dependability and Service LOW TEMP COMPRESSORS 208-230/60/3 SCROLL SEMI-HERMETIC MODEL HP RLA** MODEL HP RLA** EVAPORATOR COILS* - - - KALA-016E 1.5 8.5 LET-065 ZF06K4E 2.0 11.2 EAVA-021E 2.0 9.3 LET-090 ZF11K4E 3.5 15.5 LAHA-032E 3.0 14.7 LET-120 / LET-140 ZF15K4E 5.0 25.2 2DF3-030E 3.0 18.7 LET-180 ZF18K4E 6.0 27.7 2DL3-040E 4.0 30.1 (2)LET-120 ZF24K4E 7.5 34.7 2DA3-060E 6.0 32.6 (2) LET-140 cooled, horizontal air flow, er, individual fan. *The Last Three Digits of the Evaporator Coil Number Designates BTU s in Hundreds. For More Information About Evaporator Coils, see page 16. **The RLA s Listed Here Include Condenser Fan Motors. NOTE: For More System Options, Please Contact RDT Directly. Optional Features: Fused Disconnect Suction Accumulator Oil Separator Pre-Piped Crankcase Pressure Regulator Rack Can Be Expanded To Accommodate Up To Ten Units Rack can be Two-Tier to allow for space conservation. Air-Cooled System 15
RDT s Pre-Pipe Pipe and Pre-Wire Feature Standard Features: Correct Refrigerant Nozzle Properly Installed Liquid Line Solenoid Mounted Inside Cover Pre-Wired to Switch and Thermostat All Welded Expansion Valve Pre-Piped Suction and Liquid Line with Copper Caps Pressure Tested Shipped Under Pressure to Assure Leak Proof System Pre-Wired Thermostat Pre-Wired NEMA Disconnect Switch with Waterproof Cover RDT s Value Added Package Is Unmatched In The Industry Correct Nozzle Installed All Welded Expansion Valve Installed Pump Down Solenoid Pre-Piped And Pre-Wired Thermostat Mounted And Pre-Wired Copper Caps Typical Evaporator Model ADT or LET Pre-Wired NEMA Disconnect With Weatherproof Cover Typical Evaporator Model SM or SME 16
Refrigerated Design Texas Walk-In Freezer: Model LET MODEL: FAN 208/1 HTR 208/1 HTR 208/3 INLET SUCTION DRAIN LBS LENGTH MODEL: FAN 208/1 HTR 208/1 HTR 208/3 INLET SUCTION DRAIN LBS LENGTH LET-035 1.0 3.9 2.3 1/2 OD 5/8 OD 3/4 MPT 24 29.5" LET-140 3.0 11.7 6.8 1/2 OD 7/8 OD 3/4 MPT 62 61.5" LET-040 1.0 3.9 2.3 1/2 OD 5/8 OD 3/4 MPT 26 29.5" LET-160 4.0 15.7 9.0 1/2 OD 1-1/8 OD 3/4 MPT 81 77.5" LET-047 1.0 3.9 2.3 1/2 OD 5/8 OD 3/4 MPT 26 29.5" LET-180 4.0 15.7 9.0 1/2 OD 1-1/8 OD 3/4 MPT 84 77.5" LET-065 2.0 7.8 4.5 1/2 OD 5/8 OD 3/4 MPT 43 45.5" LET-200 5.0 19.6 11.3 1/2 OD 1-1/8 OD 3/4 MPT 101 93.5" LET-075 2.0 7.8 4.5 1/2 OD 7/8 OD 3/4 MPT 45 45.5" LET-240 6.0 23.5 13.6 1/2 OD 1-1/8 OD 3/4 MPT 121 109.5" LET-090 2.0 7.8 4.5 1/2 OD 7/8 OD 3/4 MPT 45 45.5" LET-280 6.0 23.5 13.6 1/2 OD 1-1/8 OD 3/4 MPT 124 109.5" LET-120 3.0 11.7 6.8 1/2 OD 7/8 OD 3/4 MPT 60 61.5" NOTE: LAST THREE DIGITS OF COIL NUMBER DESIGNATE BTU IN HUNDREDS (I.E. LET-120 FOR 12,000 BTU) Walk-In Cooler: Model ADT MODEL: 115 V 208 V INLET SUCTION DRAIN LBS LENGTH MODEL: 115 V 208 V INLET SUCTION DRAIN LBS LENGTH ADT-040 1.8 1.0 1/2 OD 5/8 OD 3/4 MPT 28 29.5" ADT-140 5.4 3.0 1/2 OD 7/8 OD 3/4 MPT 63 61.5" ADT-052 1.8 1.0 1/2 OD 5/8 OD 3/4 MPT 31 29.5" ADT-156 5.4 3.0 1/2 OD 7/8 OD 3/4 MPT 67 61.5" ADT-065 1.8 1.0 1/2 OD 7/8 OD 3/4 MPT 34 29.5" ADT-180 5.4 3.0 1/2 OD 7/8 OD 3/4 MPT 69 61.5" ADT-070 3.6 2.0 1/2 OD 7/8 OD 3/4 MPT 45 45.5" ADT-208 7.2 4.0 1/2 OD 1 1/8 OD 3/4 MPT 82 77.5" ADT-090 3.6 2.0 1/2 OD 7/8 OD 3/4 MPT 48 45.5" ADT-260 9.0 5.0 1/2 OD 1 1/8 OD 3/4 MPT 103 93.5" ADT-104 3.6 2.0 1/2 OD 7/8 OD 3/4 MPT 49 45.5" ADT-312 10.8 6.0 1/2 OD 1 1/8 OD 3/4 MPT 124 109.5" ADT-120 3.6 2.0 1/2 OD 7/8 OD 3/4 MPT 51 45.5" ADT-370 10.8 6.0 1/2 OD 1 1/8 OD 3/4 MPT 127 109.5" ADT-130 3.6 2.0 1/2 OD 7/8 OD 3/4 MPT 53 45.5" NOTE: LAST THREE DIGITS OF COIL NUMBER DESIGNATE BTU IN HUNDREDS (I.E. ADT-120 FOR 12,000 BTU) NOTE: WHEN MEDIUM - LARGER VELOCITY COILS ARE NEEDED FOR LARGER APPLICATIONS, PLEASE CONSULT THE FACTORY 17
Walk-In Freezer: Model SME MODEL FAN 208/1 HTR 208/1 INLET SUCTION DRAIN LBS LENGTH SME-040 1.1 5.3 1/2 OD 7/8 OD 3/4 FPT 82 31.5" SME-054 2.2 8.7 1/2 OD 7/8 OD 3/4 FPT 120 53.5" SME-065 2.2 8.7 1/2 OD 7/8 OD 3/4 FPT 120 53.5" SME-090 3.3 10.5 1/2 OD 7/8 OD 3/4 FPT 160 75.5" SME-130 3.3 15.7 1/2 OD 7/8 OD 3/4 FPT 174 75.5" SME-174 4.4 20.9 1/2 OD 1 1/8 OD 3/4 FPT 218 97.5" NOTE: LAST THREE DIGITS OF COIL NUMBER DESIGNATE BTU IN HUNDREDS (I.E. SME-130 FOR 13,000 BTU) Walk-In Cooler: Model SM MODEL 115V 208V INLET SUCTION DRAIN LBS LENGTH MODEL 115V 208V INLET SUCTION DRAIN LBS LENGTH SM-052 2.1 1.1 1/2 OD 7/8 OD 3/4 FPT 42 31.5" SM-134 6.3 3.3 1/2 OD 7/8 OD 3/4 FPT 117 75.5" SM-076 4.2 2.2 1/2 OD 7/8 OD 3/4 FPT 64 53.5" SM-156 6.3 3.3 1/2 OD 7/8 OD 3/4 FPT 123 75.5" SM-090 4.2 2.2 1/2 OD 7/8 OD 3/4 FPT 70 53.5" SM-179 8.4 4.4 1/2 OD 7/8 OD 3/4 FPT 149 97.5" SM-102 4.2 2.2 1/2 OD 7/8 OD 3/4 FPT 83 53.5" SM-208 8.4 4.4 1/2 OD 1 1/8 OD 3/4 FPT 164 97.5" SM-108 6.3 3.3 1/2 OD 7/8 OD 3/4 FPT 105 75.5" SM-249 10.5 5.5 1/2 OD 1 1/8 OD 3/4 FPT 206 119.5" NOTE: LAST THREE DIGITS OF COIL NUMBER DESIGNATE BTU IN HUNDREDS (I.E. SM-108 FOR 10,800 BTU) NOTE: WHEN MEDIUM - LARGER VELOCITY COILS ARE NEEDED FOR LARGER APPLICATIONS, PLEASE CONSULT THE FACTORY 18
Refrigerated Design Texas Our Facilities: Providing the best equipment to our customers requires RDT to ensure a safe and productive work environment. So, in 2001, RDT moved to its current 7 acre location in Waxahachie, Texas. Our large manufacturing area and ample office space ensures that RDT has the resources to continue to grow and at the same time provide the same service and customer satisfaction our customers have come to know. 19
Refrigerated Design Texas, Inc. 1808 FM 66 / P.O. Box 622 Waxahachie, TX 75167 / 75168 Toll Free (800) 736-9518 Fax (972) 937-0970 www.rdtonline.com Please note that RDT reserves the right to make changes in specification, at any time. Product information reflected in this catalog current as of August 2003.