In recent years, formicary corrosion has wreaked havoc on. Micro-channel



Similar documents
Indoor Coil Corrosion

Indoor Coil Corrosion Industry Research Report

Indoor Coil Corrosion

Dehumidification Frequently Asked Questions

Automobile Air Conditioning Primer

Rusty Walker, Corporate Trainer Hill PHOENIX

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Refrigeration Basics 101. By: Eric Nelson

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

DESIGN STANDARDS SECTION

Refrigeration Installation 101

Subject: 2005 Air Conditioning Service Guidelines

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Local Dealer:

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Vacuum. How It Relates to Refrigeration And Air Conditioning Service

CENTRAL HEAT PUMP AND AIR CONDITIONER INSTALLATION

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

CONTENTS. 1 cooling technology white paper

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION)

UNDERSTANDING REFRIGERANT TABLES

HVAC Super Pro FAQ. Can HVAC SUPER PRO be used on both hard and soft copper and aluminum tubing?

Air Conditioning 101. STN Presentation AC101

AUTOMOTIVE AIR CONDITIONING

Training Manual SUPER SEAL. Simplifying AC/R Repair. Inside Your Guide PROFESSIONAL FORMULA. Page

BPI Air Conditioning & Heat Pump Professional Training Sample Slides ( ) Agenda

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

CLIMATE CONTROL SYSTEM OPERATION, DIAGNOSIS, AND REPAIR

REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois Information compiled by Frank Prah, CMS

HVAC-02, Air Conditioning Troubleshooting and Repair

HOW HVAC WORKS. How HVAC. Works PAGE 1

10 tips for getting more reliability from your air-conditioning system [reliability]

High School Graduation years 2013, 2014, Unit/Standard Number

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Evaporator Coil. Installation Instructions GENERAL

Defining Quality. Building Comfort. Heating and Cooling Coils

A brief explanation on how air conditioning works and what terms mean

How much do you know about HVAC? Try testing yourself with the following questions and then take a look at the answers on the following page.

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Refrigerant Changeover Guidelines R-502 to R-402A/R-408A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

4AC13/14 SPLIT SYSTEM AIR CONDITIONER INSTALLATION / START-UP INSTRUCTIONS /HOMEOWNERS INFORMATION MANUAL

Test Code: 8297 / Version 1

IV. Rear Mount System

Troubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME

Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test

Get the FACTS about SEER and Deliver Better Customer Value

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

Flushing and Cleaning the A/C System

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

MAC-120HE-01 Air-Cooled Chiller

GUIDELINES ON AIRFLOW AND REFRIGERANT CHARGE VERIFICATION AND DIAGNOSTICS

Solenoid Valves and Their Importance in Refrigeration Systems. October 2007

Chilled Water HVAC Systems

Installation Instructions

Evaluate, Clean, and Tune Guidance

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

4AC13/14 SPLIT SYSTEM AIR CONDITIONER INSTALLATION / STARTUP INSTRUCTIONS /HOMEOWNERS INFORMATION MANUAL

Characteristics of Evaporators

CONDENSING UNIT AIR CONDITIONING INSTALLATION & SERVICE REFERENCE. Important Safety Instructions. Installation Clearances. Shipping Inspection

Geothermal Alliance of Illinois. TXVs Theory and Fundamentals John Haug Senior Application Engineer Emerson Climate Technologies - Flow Controls

Contents and Nomenclature

How To Understand Evaporator

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

A/C refrigerant system, overview

CONDENSING UNIT AIR CONDITIONING INSTALLATION & SERVICE REFERENCE. Important Safety Instructions. Shipping Inspection. Codes & Regulations

A. Section includes air conditioning units, controls and control panels.

The Owners Coated Coil, Cleaning and Maintenance Service Manual.

123 street Salt Lake City, Utah 84092

ARMSTRONG AIR HEAT PUMPS

AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON

Answers to Your Questions from the Webinar

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

Addendum to Florida Academy Catalog for: HVAC Fundamentals HVAC Advanced Fundamentals

ON-VEHICLE INSPECTION

New Trends in the Field of Automobile Air Conditioning

Refrigerant Changeover Guidelines HCFC R-22 to HFC R-404A/R-507. Leading the Industry with Environmentally Responsible Refrigerant Solutions

How To Insure Against Problems With Your Home Warranty

COMPRESSOR REPLACEMENT PROCEDURE

LOBOY 16 AIR CONDITIONERS

MACS Recommended Service Procedures

HVAC Claims: Repair vs. Replacement

SYLLABUS FOR SIX MONTHS - FULL TIME CERTIFICATE COURSE IN REFRIGERATION AND AIR-CONDITIONING. Effective From :- UNDER DEVELOPMENT.

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Todd M. Rossi, Ph.D. President

Cased/Uncased Coils For Gas And Oil Furnaces

SECTION AIR CONDITIONING UNIT

BVCAA inc HVAC Service Bid Sheet Item Description. Materials Labor Total 3/24/2015

How To Design A Refrigeration System

How To Clean Water From An Ammonia Refrigeration System

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

Glossary of Heating, Ventilation and Air Conditioning Terms

Evaporator Coil Installation Instructions

INSTALLATION INSTRUCTIONS

Recharge Procedure for Telemark TVP-2000 and TVP-3500

Transcription:

As seen in the October issue of Micro-channel Evaporator-coil Technology An overview of all-aluminum micro-channel evaporator-coil technology, including technical differences HVAC professionals need to be aware of when installing or servicing. B y M a t t L a t t a n z i a n d D o u g P r i e s t l e y All images courtesy of NORDYNE. An example of an aluminum micro-channel evaporator coil. In recent years, formicary corrosion has wreaked havoc on the heating and cooling industry. As the No. 1 cause of evaporator-coil leaks, formicary corrosion has gotten worse for a host of reasons: Chinese-manufactured drywall, tighter home construction, different materials used in insulation and carpeting, new adhesives and more. The list of blame goes on and on. Regardless of the cause, HVAC manufacturers have been quick to address the problem with fast fixes, such as coatings and different lubricants, as well as long-term product changes such as all-aluminum coil construction. 14 RSES Journal OCTOBER 2012 What is formicary corrosion? Formicary literally means ants nest. So, formicary corrosion, as it relates to evaporator coils, is referring to small wandering pits that resemble the tunnels in an ants nest. This corrosion attacks copper and copper alloys exclusively, and is prevalent in southern climates with high humidity. Four components are necessary for formicary corrosion to happen: copper, moisture, oxygen and an organic acid (from such items as adhesives, cabinets, countertops, foam insulation, laminates, oil based paints, paneling, plywood, silicone caulking, latex paints, cosmetics, disinfectants, deodorizers, wallboard and other common household/construction products). In areas such as the southeastern Unites States, all four of these components are commonly found inside the central A/C system. But if one component can be eliminated, so can the corrosion and the resulting leaks. History of micro-channel The automotive industry shares many of the same manufacturing challenges faced in HVAC: cost, size and weight. In the early 1990s, the automotive industry had a significant challenge relative to air-conditioning systems the industry had to transition from R-12 to more environmentally friendly R-134a, a refrigerant that operates at slightly higher condensing pressures. Faced with these issues, the automotive industry investigated alternative coil technologies to improve the performance of their systems while maintaining or reducing size and weight. The answer was all-aluminum micro-channel coil

Four components are necessary for formicary corrosion to happen: copper, moisture, oxygen and an organic acid... A close-up view of a micro-channel evaporator-coil s allaluminum construction. technology. It became the industry standard, and now, 20 years later, this technology is being used in residential heating and cooling systems. Overview and benefits Micro-channel coils are aluminum-extruded channels that are mechanically brazed to aluminum fins. The coil has three basic components: micro-channel tubes, aluminum fins and two manifolds. All three components are brazed together in a hydrogen/nitrogen brazing furnace. The lack of oxygen and water vapor in the brazing process ensures a robust reliable braze joint. Additionally, the product quality is further amplified due to one homogeneous braze joint as opposed to more than 300 braze joints typically found on standard coppertube/aluminum-fin coils. The two manifolds facilitate a two-pass process. In the first pass, the high-pressure superheated refrigerant is de-superheated and condensed into a liquid. The second pass subcools the liquid refrigerant below its saturation temperature prior to entering an expansion device. This construction provides a coil that is typically 50% lighter and uses, on average, 50% less refrigerant when compared to a copper-tube/aluminum-fin coil design. Heat transfer is also enhanced, leading to smaller, more-efficient coils. Additionally, the all-aluminum uniform design provides a structurally robust coil. The biggest benefit, however, is relative to formicary corrosion. What technicians need to know Many online HVAC forums are filled with misinformation about installing and maintaining micro-channel evaporator coils. The coils are not more complicated than traditional copper-tube/aluminum-fin coils, but they are more sensitive to accurate charging. If technicians have questions about OCTOBER 2012 RSES Journal 15

A traditional copper coil showing formicary corrosion. Field failure in this particular coil occurred just two months from manufacture date. installing or servicing these coils, they should go directly to their distributor or the manufacturer, as other online answers may be incorrect. Installation The installation of micro-channel evaporator coils follows the same process as a traditional fin-in-tube coil. The installer will need to: gbraze with nitrogen; ginstall a liquid-line filter-drier; gfollow the triple evacuation method; and gweigh in the additional charge. These are the same practices that should be followed when installing any HVAC component or system. Installers should always refer to the manufacturer s installation instructions for the proper size or metering device. Some micro-channel coils may have dual applications and may need a piston or TXV change. The installation of these metering devices is very similar to a copper-tube/aluminumfin coil, and no special tools are required. In most cases, brazing is not necessary when installing a TXV. It is best practice to have a small flow of nitrogen when brazing in any lineset, but it is critical with micro-channel coils. If the installer brazes without nitrogen, oxidation 16 RSES Journal OCTOBER 2012 The coils are not more complicated than traditional copper-tube/aluminum-fin coils, but they are more sensitive to accurate charging. flakes can form on the inside of the copper and can clog the narrow micro-channels inside the coil. In many cases, the evaporator coil has a filter screen at the inlet of the metering device that also can become clogged by oxidation flakes. Always install the liquid-line filter-drier as close to the evaporator as possible. This will catch any debris or moisture before entering the metering device. When evacuating the system, technicians should use the triple evacuation method and always use a micron gauge to determine if the correct vacuum is reached. Do not rely

One of the benefits of micro-channel coils is that they require less refrigerant. However, this means there is also less room for error when charging the system, as technicians need to be within ounces of the correct charge, not pounds. on a gauge set alone to determine if the correct vacuum is reached. Charging One of the benefits of micro-channel coils is that they require less refrigerant. However, this means there is also less room for error when charging the system, as technicians need to be within ounces of the correct charge, not pounds. When charging a micro-channel system, any additional charge should be weighed in with a refrigeration scale. Technicians should not use a bathroom or fish-type scale, as they do not have the accuracy of the refrigeration scale. When adding OCTOBER 2012 RSES Journal 17

This close-up view of a micro-channel evaporator coil shows the micro-channels and fins. charge to dial in the system, add small amounts of refrigerant at a time. It is also necessary to allow the system to level out in between adding refrigerant. Wait a minimum of 10 minutes between each addition. To ensure accuracy, gauge sets should use the shortest hoses possible not a hose that is as long as the technician is tall. Since micro-channel systems use less refrigerant, the trapped liquid in the high-side hose can affect the charge levels in the system. Always use some type of low-loss fittings on your gauge set, and meter the trapped refrigerant in the highside hose back into the system through the low-side hose. Remember to meter the refrigerant during this process. If there are any questions regarding the charge levels in a micro-channel system, it might be necessary to remove the entire amount of refrigerant and weigh it back into the system. Repair If a micro-channel evaporator coil needs a repair, the technician should refer to the specific manufacturer s installation instructions. Repair kits using epoxy do exist, but in many cases, a coil replacement might be a better or preferred option. While providing much greater resistance to formicary corrosion, micro-channel evaporator coils are not more difficult to install or service if the technician follows standard industry practices and the manufacturer s instructions. Obtaining the correct system charge can be accomplished efficiently and within a reasonable period of time. Matt Lattanzi is the Director of Product and Warranty Management at NORDYNE, a heating and cooling manufacturer special- izing in residential systems. Lattanzi is a member of ASHRAE and serves on various AHRI committees. For more information, e-mail lattanzimh@nordyne.com or visit www.heynordyne.com. Doug Priestley is the Technical Services Supervisor at NORDYNE and based out of the company s O Fallon, MO, corporate office. Priestley oversees HVAC contractor training materials, including online courses and NATE-recognized continuing education hours. For more information, e-mail tech_services@nordyne.com or visit www.nordyneu.com. The Triple Evacuation Method 1. First vacuum: Pull the system down to 1,500 microns. 2. Break the vacuum with nitrogen; release nitrogen. 3. Second vacuum: Pull the system down to 1,500 microns. 4. Break the vacuum with nitrogen; release nitrogen. 5. Third vacuum: Pull the system down to a minimum of 500 microns. 6. Charge the system. 18 RSES Journal OCTOBER 2012