Optimux-1553 Fiber Multiplexers for 3 E3/T3 over STM-1/OC-3



Similar documents
Optimux-1551 Fiber Multiplexer for 63E1/84T1 over STM-1/OC-3

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

Optimux-34, Optimux-25

Optimux-134, Optimux-125

Optimux-134, Optimux-125

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

Kilomux-2100/2104. Modular integrating access multiplexer for data, voice, fax and LAN. Data Sheet. The Access Company

FCD-E1E Managed E1 and Fractional E1 Access Device

IPmux-1E TDM Pseudowire Access Gateway

Megaplex-2100/2104 Modules ML-1/2E1/T1, MLF-1/2E1/T1

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

DXC-8R/10A/30 Multiservice Access Nodes

Where to buy > See the product page > Data Sheet. E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

DXC Family. Multiservice Access Node FEATURES

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

WEB RANger-II Internet Access Router

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

Egate-100 Gigabit Ethernet over TDM Aggregation Gateway

TDMoEthernet. Description

Loop-O9310 4E1 or 4T1 Fiber Optical Mux

STM-1 Synchronous Digital Multiplexer and Multiservice Access Node

Loop-IP6700 TDMoEthernet

Optimux-XLT1. Multiple T1 and Ethernet Multiplexer Installation and Operation Manual. Notice

Loop-IP6700 TDMoEthernet

CERAGON. Broadband Wireless Network Solutions GHz Mbps SONET/SDH IP ATM Fast Ethernet Built-in ADM

FOM-5A, 6A. Asynchronous Fiber Optic Modem

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Loop-IP6702 TDMoEthernet

INTRODUCTION TO MEDIA CONVERSION

HDO700 P FIBRE OPTIC TRANSMITTER

8-Port E3/DS3 ATM Line Card Overview

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

CTC Union Technologies Co.,Ltd. Far Eastern Vienna Technology Center (Neihu Technology Park) 8F, No. 60 Zhouzi St., Neihu, Taipei 114, Taiwan

Long Range Ethernet Extender

RADview/TDM. Element Management System for TDM Applications Optimux-T RAD Data Communications Publication 06/05

TrueAlarm Fire Alarm Systems

HARTING mcon 1000 Introduction and features

WaveReady CFM. Optical Link Monitoring System: Continuous Fiber Monitor

Media Converters & Chassis

24-Port Channelized E1/T1 Line Card Overview

ORION TELECOM NETWORKS INC. T1

Loop-V4300 MINI DACS E1/ T1 CONVERTER

SHEET. Skorpion Managed Ethernet Switch Series. EISK8M Series

F2400 FOM II Series Fiber Optic Modem Technical Manual

3500/22M Transient Data Interface

Application. Benefits. Contact us. Solution for Indoor TETRA coverage. TETRA/TETRAPOL Repeater RF/OF High Power. To ensure TETRA coverage everywhere

Application. Key Features. Benefits. Contact us. Solution for GSM-R coverage. AIR Repeater RF/RF GSM-R 900. To ensure GSM-R coverage everywhere

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

FALCO. Broadband Groomer. F-330 Series. Applications. Access system for:

USER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

Gigabit Ethernet Copper-to-Fiber Converters

FlexPoint T1/E1 Copper to Fiber Line Driver

Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications

IPmux-216 TDM Pseudowire Access Gateway

Media Converters & Chassis

Attaching the PA-A1-ATM Interface Cables

2-Pair HDSL1 Adtran Fiber Optic Link System

IPmux-16L Hub-Site Pseudowire Access Gateway

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

HARTING econ 3000 Introduction and features

Manageable 10/100/1000 Mbs Ethernet Modular Multi-Media Switch

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

NetScanner System. Toronto: , Montreal: , Toll Free: ,

T3 Mux M13 Multiplexer

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Setting Up and Testing the MAX Hardware

LT-82 Stationary IR Transmitter

G-TAP A Series // Data Sheet

Airmux-200 Wireless Broadband Multiplexer

Light Link Series 2 LT1550. Laser Transmitter with Erbium Doped Fibre Amplifier. Description. Features

FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications

BV-10 Performance Endpoint Unit PERFORMANCE DEMARCATION FOR NETWORK-WIDE VISIBILITY

Product Overview. Features CHAPTER

EM316T1E1-XY. Features

Product Specifications

10/100/1000 Base-T to Gigabit Fiber Media Converter

Terminal and Dimension

Deliver instant switching in four different modes for data center, control room, pooling, and similar applications.

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

MPX100 Intelligent Ethernet Test Probe

Perle 10/100 Ethernet Media Converters

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

SOLUTIONS FOR AN EVOLVING WORLD IMUX T1/E1 Multiplexer. with common logic redundancy IMUX 2000 T1/E1 1

HES-3106-RF Series Managed CPE Switch

MICROSENS. Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) General. Features

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

Transcription:

Where to buy > See the product page > Data Sheet Optimux-1553 STM-1/OC-3 terminal multiplexer for grooming high-order legacy traffic (TDM) over SDH/SONET networks Up to three E3 or T3 data channels multiplexed using a single hot-swappable card Any Traffic over Fiber Optional 1+1 redundant network interface (single-ended MSP/APS); 1+1 protection of E3/T3 tributaries and power supply for complete carrier-class hardware redundancy and serviceability Plug-and-play operability Optimux-1553 is a unique STM-1/OC-3 terminal multiplexer for transport of high-order legacy PDH traffic over SDH/SONET. Three E3 or T3 tributary channels are mapped into a standard channelized STM-1/OC-3 uplink, extending the local loop up to 80 km (50 miles), while creating a transmission layer fully compatible with regional and national SDH/SONET networks. The Access Company

Optimux-1553 Power supply and uplink modules in Optimux-1553 can be backed up and are field-serviceable. Uplink 1+1 single-ended MPS/APS redundancy is supported in compliance with the G.841 and GR-253-CORE standards. Power supplies are also backed up and are hot-swappable. These features ensure that Optimux-1553 has no single point of failure, and is fully compatible with carrier class requirements. Optimux-1553 is available with either coaxial or fiber optic short/long haul uplink interfaces. The unit provides high availability, and high-quality performance monitoring of the traffic path, from the SDH/SONET network to the customer premises. The simplicity, compact size and low power consumption of Optimux-1553 allow easy rack installation on both customer premises and telecommunication facilities. Setup, control, status monitoring, and diagnostics information can be performed using one of the following methods: ASCII terminal connected to the DB-9 control port Telnet host via the dedicated Ethernet port Network management station (NMS) running RADview-EMS, RAD s client-server CORBA-based SNMP network management application. NMS is connected via the dedicated Ethernet port RAD s Web-based remote access terminal application, via the dedicated Ethernet port TFTP for software update and remote configuration, via the dedicated Ethernet port. Figure 1. Optimux-1553 Back Panel Showing the Interface Ports

Data Sheet Specifications UPLINK (NETWORK) Interfaces Electrical (Coax) STS-3 Fiber Optic STM-1/OC-3 Compliance Bellcore GR-253-CORE, Bellcore GR-499-CORE, ITU-T G.703, G.707, G.783, G.841, G.957, RFC 3592 Redundancy 1+1 Line Rate 155.52 Mbps ±20 ppm Copper Line Attenuation Typically 12.7 db at 78 MHz using RG-59-B/U cable Copper Impedance 75Ω Connectors Electrical: BNC Fiber Optic: ST, SC, FC, SC/APC Line Code Electrical: CMI Fiber Optic: NRZ scrambled Specifications and Ranges See Table 1 E3/T3 INTERFACE Compliance Bellcore GR-253-CORE, Bellcore GR-499-CORE, ITU-T G.783, ITU-T G.823, RFC2496 Data Rate T3: 44.736 Mbps E3: 34.368 Mbps Line Code B3ZS Impedance 75Ω, unbalanced Jitter According to Bellcore GR-499-CORE and ITU-T G.823 Connectors 3 pairs of unbalanced BNC connectors (one Tx and one Rx for each E3/T3 tributary channel) SUPERVISORY & MANAGEMENT PORTS Control Port Interface: V.24/RS-232 Connector: DB-9, female Format: asynchronous Baud rate: 9,6 kbps, 19,2 kbps, 38,4 kbps, 57,6 kbps, 115,2 kbps, autobaud detect Ethernet Ports Interface: 10/100BaseT Connector: shielded RJ-45 Mode of operation: autonegotiation, full/half-duplex ALARM RELAY Rating 60 VDC max or 30 VAC max, at 0.5A max Input Alarm 10 VDC min, 48 VDC max, at 0.5A max Connector Dry contact, DB-9 female Figure 2. Optimux-1553 Units in a Point-to-Point Topology

Optimux-1553 INDICATORS Power A, B Green: Power is OK Red: Power fault Off: No power System TST (yellow): On: Unit is in test mode Blinking: Downloading new software FLT (red): Access and control card is in fault condition ON A/B (green): On: The 3E3/3T3 card is active Blinking during auto-baud detect process Alarm MAJ (red): On: Major Alarm Blinking: Major Alarm + ACO button pressed MIN (yellow): On: Minor Alarm Blinking: Minor Alarm + ACO button pressed Uplink Front and Rear Panels: SYNC A/B LOSS (red): Electrical/optical signal not present or out-of-frame detected on uplink (A/B) respectively AIS A/B (yellow): AIS signal detected on uplink A/B Rear Panel only (on uplink module): SIG (green): Signal detected on the respective uplink card Ethernet (Rear Panel only) 100 (green): On: operating at 100 Mbps Off: operating at 10 Mbps LINK/ACT: Green: Ethernet link integrity Yellow: Traffic activity Station Clock Interface (Rear Panel only) OK (green): External valid E1/T1 clock source exists on clock connector E3/T3 Tributary Channels (Front Panel only) SYNC LOSS (red): Loss of signal detected on the respective non masked channel AIS (yellow): On: AIS signal detected on the respective non masked channel Blinking: The channel is masked and the LED status for the masked channels parameter is set to Blink by the user Off: The channel is masked and the LED status for the masked channels parameter is set to Off by the user OR the channel is not masked and no Loss of Signal or AIS is detected on the respective channel.

Data Sheet Table 1. Uplink Interface Options Module Name (Ordering Option) Wavelength Fiber Type Transmitter Type Power Coupled into Fiber Receiver Sensitivity Typical Max. Range [nm] [μm] [dbm] [dbm] [km] [miles] Connector Type OP-M/CX/155 - Copper cable - - - 135m 443 ft Coax interface See Note 1 OP-M/SC/85L OP-M/FC/85L OP-M/ST/85L OP-M/SC/13M OP-M/ST/13M OP-M/SC/13L OP-M/FC/13L OP-M/ST/13L OP-M/SC/15L OP-M/FC/15L OP-M/ST/15L OP-M/SC/13LH OP-M/FC/13LH OP-M/ST/13LH OP-M/SC/15LH OP-M/FC/15LH OP-M/ST/15LH OP-M/SC/SF1 Tx: 1310 Rx: 1550 OP-M/SC/SF2 Tx: 1550 Rx: 1310 850 62.5/125 multimode 1310 62.5/125 multimode 1310 9/125 single mode 1550 9/125 single mode 1310 9/125 single mode 1550 9/125 single mode 9/125 single mode (single fiber) 9/125 single mode (single fiber) OP-M/SC/SF3 Tx/Rx: 1310 9/125 single mode (single fiber) Laser (VCSEL) -14 to -20-26 2.0 1.2 SC, FC, ST LED -14 to -20-31 2.0 1.2 SC, ST Laser -8 to -15-31 20 12.4 SC, FC, ST Laser -8 to -15-31 20 12.4 SC, FC, ST Laser (long haul) Laser (long haul) 0 to -5-34 40 24.8 SC, FC, ST 0 to -5-34 80 49.7 SC, FC, ST Laser WDM -8 to -15-29 20 12.4 SC Laser WDM -8 to -15-29 20 12.4 SC Laser (SF3) -8 to -15-27 20 12.4 SC/APC Notes: 1. For copper cables (coax interface), a range of 135m is attainable when using RG-59 B/U (at 78 MHz, in accordance with the square root frequency law). 2. The ranges specified above were calculated according to the following typical attenuation rates (with a 3 db margin): 3.5 db/km for 850 nm multimode 0.4 db/km for 1310 nm single mode 0.25 db/km for 1550 nm single mode

Optimux-1553 DIAGNOSTICS Uplink and Tributary Links Local Loopback Remote Loopback GENERAL Power AC: 100 to 240 VAC (±10%), 50 to 60 Hz DC: -48 VDC (-40 to -60 VDC) Power Consumption AC: 77 VA max, 0.4A max DC: 37W max, 1A max Physical Height: 4.4 cm (1.75 in) Width: 44.0 cm (17.3 in) Depth: 30.0 cm (11.8 in) Weight: 5.0 kg (11.0 lb) max. Environment Temperature: 0 C to 55 C (32 F to 131 F) Humidity: Up to 90%, non-condensing Figure 3. Optimux-1553 Extending an SDH/SONET Network towards Remote Customers

Data Sheet Ordering STANDARD CONFIGURATIONS OP-1553/3E3T3/AC/R/SC/13L OP-1553/3E3T3/AC/SC/13L OP-1553/3E3T3/48/R/SC/13L OP-1553/48/R OP-1553/3E3T3/AC/R/SC/13L/D OP-1553/AC/R SPECIAL CONFIGURATIONS OP-1553/*/$/#/!/?/+/^ OP-1553-M/*/S Additional tributary module Note: Each module should be ordered separately. OP-M/?/+ Uplink interface module only (see Table 1) Note: Uplink modules and tributary modules are ordered separately. Legend * Tributary interface module: 3E3T3 Module with 3 E3/T3 links 2X3E3T3 Two 3 E3T3 modules $ Station clock: STC Optional station clock Note: For tributary module redundancy, order two modules. Each tributary module may be defined either as E1 or T1 channels. # Power supply: AC 100 to 240 VAC 48-48 VDC AD 100 to 240 VAC power supply plus redundant -48 VDC power supply! Redundant power supply: R Redundant power supply of the same type? Uplink connector: ST ST fiber SC SC fiber FC FC fiber Note: For single fiber connection, only SC type connectors are available. For 1310 nm multimode LED option, only SC and ST type connectors are available. + Optical wavelength and transmitter type (not relevant with CX option): CX Electrical interface with coaxial BNC connectors 13 1310 nm, multimode LED 13L 1310 nm, single mode, laser diode 15L 1550 nm, single mode, laser diode 13LH 1310 nm, single mode, long haul laser diode 15LH 1550 nm, single mode, long haul laser diode 85L 850 nm, multimode VCSEL SF1 Transmit 1310 nm, receive 1550 nm SF2 Transmit 1550 nm, receive 1310 nm SF3 1310 nm single wavelength laser Note: For single-fiber applications, a device with the SF-1 connector should always be used opposite the device with the SF-2 connector, and vice versa. The SF-3 connector can be used on both sides of the link. ^ Redundant STM-1 uplink (default = single uplink): D Redundant uplink for unidirectional 1+1 protection SUPPLIED ACCESSORIES AC power cord (when AC power supply is ordered) DC adapter plug (when DC power supply is ordered) RM-34 Hardware kit for mounting one Optimux-1553 unit into a 19-inch rack OPTIONAL ACCESSORIES CBL-DB9F-DB9M-STR Control port cable Power Supply OP-1553-PS/AC: 100 to 240 VAC OP-1553-PS/48: -48 VDC

Optimux-1553 Data Sheet Table 2. Optimux Comparison Table Feature OP-108L OP-108/106 OP-134/125 OP-1032/1025 OP-45/45L OP-1551 OP-1553 Uplink Fiber Optic Fiber Optic E3, Fiber Optic Fiber Optic T3, Fiber Optic Copper, Copper, STM-1/OC-3 STM-1/OC-3 Bandwidth (Mbps) Number of trunks Ethernet support Special features Card version for LRS-102/ MP-4100 108 108/106 34/25 or 134/125 1000 (Proprietary) 45 155 155 4 E1 4 E1/4 T1 16 E1/16 T1 16 E1/16 T1 21 E1/28 T1 21/42/63 E1 3 E3/3 T3 28/56/84 T1 Reduced power Redundant, Full bandwidth, 3xGbE User Ring support Full redundancy Full redundancy consumption hot-swappable Ethernet license interfaces (Optimux-45) cost-effective uplinks activation Works with Works with OP-108C OP-34C/OP-25C 179-100-06/11 (2.0) Specifications are subject to change without prior notice. 1997 2011 RAD Data Communications Ltd. The RAD name, logo, logotype, and the terms EtherAccess, TDMoIP and TDMoIP Driven, and the product names Optimux and IPmux, are registered trademarks of RAD Data Communications Ltd. All other trademarks are the property of their respective holders. International Headquarters 24 Raoul Wallenberg Street Tel Aviv 69719, Israel Tel. 972-3-6458181 Fax 972-3-6498250, 6474436 E-mail market@rad.com North America Headquarters 900 Corporate Drive Mahwah, NJ 07430, USA Tel. 201-5291100 Toll free 1-800-4447234 Fax 201-5295777 E-mail market@rad.com www.rad.com Order this publication by Catalog No. 803424 The Access Company