System Maintenance and Monitoring



Similar documents
AT&T Private Line Service OC-192 SERVICE DESCRIPTION AND INTERFACE SPECIFICATION

Chapter 4 T1 Interface Card

T3 Module USER MANUAL. Part Number L1 / L1

Product Overview. Features CHAPTER

- T-Carrier Technologies -

Configuring E1 and T1 Interfaces

Configuring E1 and T1 Interfaces

RADview/TDM. Element Management System for TDM Applications Optimux-T RAD Data Communications Publication 06/05

Overview of SDH and SONET overhead processing commonalities and differences.

SNMP Network Node Manager (NNM) Setup Guide

KCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7

Trinity Feature: T1/E1 Configuration

CipherLab 5100 Time Attendance Utility Manual

Maintaining the Content Server

Overview of SDH and SONET overhead processing commonalities and differences.

T3 E3 and T1 E1 Controller Commands on Cisco IOS XR Software

Adtech Data Link Simulators.

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

External Storage 200 Series. User s Manual

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

Handheld LPC Utility Software for Windows. Operation Manual

A Brief Overview of SONET Technology

ACCESS 9340 and 9360 Meter Ethernet Communications Card ETHER

CS SoftDent Practice Management Software Installation Guide for Client/Server Configurations

PA-MC-T3 Multi-Channel T3 Synchronous Serial Port Adapter Enhancement

Cooper Bussmann. Network Management System QuickStart Guide. Read and Retain for Future Reference. Version 1.0

Getting Started with IntelleView POS Administrator Software

Signature Center Getting Started Guide

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

User's Manual. Intego Remote Management Console User's Manual Page 1

Appendix D T1 Overview

1. Overview. 2. F-bit Utilization

RECOMMENDATION ITU-R S.1251

Atlas Event Logging Explanation

10 Gigabit Ethernet WAN PHY

Modbus and ION Technology

Setting Alarms and Inserting Errors

MDM Mass Configuration Tool User s Manual

Access Control Unit User s Guide

Network Management System and ICB Management System Software for T1 User s Guide

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

T3 Mux M13 Multiplexer

SEC 4100 SYSTEM MONITOR Programmable Serial Interface Card Series 2

Appendix B RCS11 Remote Communications

How To Set Up A Modbus Cda On A Pc Or Maca (Powerline) With A Powerline (Powergen) And A Powergen (Powerbee) (Powernet) (Operating System) (Control Microsci

The Fundamentals of DS3

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

PowerLogic ION Setup 3.0

Remote Monitoring of Woodward easygen-3000

Comdial Network Management System User Instructions

ABB solar inverters. Installation and setup instruction Aurora Manager TL software and ABB PVI-USB-RS232_485 adapter

Monitoring Network DMN

Market Central

NATIONAL SECURITY AGENCY Ft. George G. Meade, MD

Doors in a Network Environment

PageR Enterprise Monitored Objects - AS/400-5

Network Management System and ICB Management System Software User s Guide

How To Test A Ds1 Signal

User Manual. Thermo Scientific Orion

This document also includes steps on how to login into HUDMobile with a grid card and launch published applications.

APPLICATION NOTE # Using Sage SMOS for VoIP Testing, IP Phone to IP Phone TABLE OF CONTENTS

24-Port Channelized E1/T1 Line Card Overview

Monitoring and Testing

FirePass NSE RMA4 Replacement Script. FirePass. Network Support Engineer RMA4 Replacement Script, Version 1.01

Connecting and Setting Up Your Laptop Computer

Modbus and ION Technology

Polycom CMA System Upgrade Guide

Deploying Windows Streaming Media Servers NLB Cluster and metasan

DVR4C Remote Viewer Operation Manual Table of Contents EN 3 1. OVERVIEW MINIMUM PC REQUIREMENTS INSTALLING THE PROGRAM...

1. Make sure that no client accounts are open. 2. Click on Setup, then click Modem. The Modem Setup window will appear.

Limitation of Liability

2-port STM-1/OC-3 Channelized E1/T1 Line Card for Cisco Series Internet Routers

Managing Faults. 9.1 What Is Fault Management? CHAPTER

NortechCommander Software Operating Manual MAN R6

ORION TELECOM NETWORKS INC. T1

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

WebMeter Internal Web Server Feature

Tenor SNMP Implementation

ISDN Phone Lines with Metasys

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

Crow Limited Warranty. Print Version 017

DS-3 Technology and Testing Overview

Remote PC Guide for Standalone PC Implementation

L5354 ControlNet Communications Interface

CS SoftDent Practice Management Software Installation Guide for Client/Server Configurations

MN-700 Base Station Configuration Guide

E1+Jitter+Wander+Data

Intel Device View. User Guide

64-Bit Compatibility with Micromeritics Applications

TruePort Windows 2000/Server 2003/XP User Guide Chapter

How to Obtain an OPC License--5. Creating a System Code 5 Entering an Authorization Code 6. Getting Started with SNMP Editor--7

2-Pair HDSL1 Adtran Fiber Optic Link System

Network Monitoring. SAN Discovery and Topology Mapping. Device Discovery. Send documentation comments to

Digital Trunks. Objectives. When you finish this module, you will: Understand the different types of digital trunks.

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

Canopy T1/E1 Multiplexer. User Guide. T1E1Mux-UG-en Issue 3 September 2004

DTAP3000 DTSX3000 Control Visualization Software LAS2.0 Data Conversion Guide

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

Transcription:

CHAPTER 16 This chapter describes the system maintenance and monitoring capabilities available in the element management system (EMS), and includes the following sections: Getting System Information, page 16-2 Provisioning the MTAC RS-232 Port on the Cisco 6732, page 16-5 Shutting Down the Ethernet for System Protection, page 16-5 Monitoring Performance, page 16-7 16-1

Getting System Information EMS Version EMS provides the following information about your NE, its plugin cards, and EMS: EMS Version, page 16-2 NE Information, page 16-2 Plugin Card Information, page 16-4 One-Day Performance Monitoring, page 16-7 Performance Monitoring Codes, page 16-8 NonSONET Performance, page 16-8 Monitoring SONET Performance, page 16-9 To view the version of EMS software currently running on a workstation, select Help > Version from either Cisco 6700 NetView or Cisco 6700 NodeView. EMS displays the date and release number of the software in use. NE Information Step 1 From Cisco 6700 NetView, double-click the node. EMS launches Cisco 6700 NodeView. 16-2

Step 2 Double-click the node nameplate to launch the NE provision window. (See Figure 16-1.) Figure 16-1 INE Provision Window Information provided includes: NE Name Alias NE Locations NE Node Types NE Time of Day NE Uptime NE Backplane Version NE Loaded Software Version (this refers to the MCC, or embedded, software, not the version of EMS software that runs on your workstation) NE CLEI (common language equipment identifier) Code NE Serial Number NE Backplane Type Alarm Status Problem List 16-3

Plugin Card Information Step 1 From Cisco 6700 NodeView, select Objects > Plugin Card Details. EMS displays the plugin card detail information window. (See Figure 16-2.) Figure 16-2 Plugin Card Detail Window Step 2 In the drop-down Card ID menu, select a card to display that card s information, which includes: System Name Card ID Card Type Admin Status Operation Status Software Version (this refers to the MCC, or embedded, software, not the version of EMS software that runs on your workstation) Backup Software Version FPGA 1 FPGA 1 Backup Version FPGA 2 FPGA 3 FPGA 4 CLEI Code Serial Number 16-4

Provisioning the MTAC RS-232 Port on the Cisco 6732 The Cisco 6732 metallic test access card (MTAC) offers an EIA/TIA-232 interface (the older but more widely recognized term RS-232 is used in this chapter) for local access through an EMS workstation. See the application note RS-232 Connection for the workstation provisioning procedure. Step 1 From Cisco 6700 NodeView, double-click the MTAC RS-232 port icon. EMS launches the MTAC RS-232 provisioning window. (See Figure 16-3.) Figure 16-3 MTAC Provisioning Window Step 2 Step 3 Set the following parameters: Baud Rate Select the interface baud rate. Number of Bits Select the number of bits for the connection. Parity Select None, Even, or Odd parity. Stop Bits Select the number of stop bits. Flow Control Select None or Hardware flow control. Test Access Select the MTAC interface used, Front or Backplane. Target ID Leave blank. Click Apply to provision the MTAC RS-232interface. Note You cannot provision an MTAC RS-232 port on a Cisco 6705 or Cisco IAD1101. Shutting Down the Ethernet for System Protection The Ethernet port on the Cisco IAD1101 and on the Cisco 6705 main control card (MCC) can be shut down to secure the NE and prevent unauthorized system access. 16-5

Caution Placing the Ethernet port out of service should only be performed after all provisioning is complete. You cannot communicate with the NE if this port is disabled, and a solid inter node data link (INDL) has not been established between the NE in question and a remote NE. Before disabling the Ethernet port, Cisco Systems recommends backing up the NE database so you can retrieve and use the information if any system difficulties occur. (See Backing Up the System Database on page 14-2.) Step 1 From Cisco 6700 NodeView, double-click the Ethernet port LED on the MCC card. EMS launches the Ethernet line provision window (see Figure 16-4). Figure 16-4 Put Ethernet Port Out of Service Step 2 Set the Admin Status of the Ethernet port to OutOfService. 16-6

Step 3 Click Apply to put the Ethernet port out of service. EMS displays a warning message. (See Figure 16-5.) Figure 16-5 Ethernet Shutdown Warning Message Step 4 Click Yes to disable the Ethernet port. Caution The Ethernet port remains inoperable until you send a remote instruction from an EMS workstation using an INDL to place the port back in service. Monitoring Performance Performance monitoring is the action of collecting data on the signal over a period of time to detect degradations in the section, line, or path. The parameters that are collected are based on signal integrity, number of protection switches, and number of failures. One-Day Performance Monitoring All Cisco 6700 Series line interface modules are synchronized to Greenwich Mean Time (GMT), rather than the Time of Day setting on the EMS workstation. One-day performance monitoring (PM) tests use GMT, not the EMS time of day, to determine the start and end times of the 24-hour monitoring window. 16-7

Performance Monitoring Codes NonSONET Performance Table 16-1 through Table 16-6 show the codes for monitoring degradations on sections, lines and paths. Table 16-1 Performance Monitoring Codes NonSONET CV-L Coding violation line The count of BPVs and EXZs occurring over the accumulation period. An EXZ increments the CV-L by one, regardless of the length of the zero string. For a B8ZS-coded signal, BPVs that are part of the zero substitution code are excluded from the count. ES-L Errored second line The count of seconds during which one or more of the following has occurred: BPVs, EXZs and LOSs. For a B8ZS-coded signal, BPVs that are part of the zero substitution code are excluded. SES-L Severely errored second line CV-P Coding violation path CSS-P Controlled slip second path The count of seconds during which 1,544 or more BPVs or EXZs, or one or more LOS defects, have occurred. For DS1-ESF paths, this parameter is a count of detected CRC-6 defects. For DS1-SF Paths, this parameter is a count of defected FEs. Only applies to DS1 extensions and Multiple Interface Group Features. This parameter is a count of seconds during which a CS has occurred. Counts of CSs can be accurately made only in the NE of the DS1 signal where the CS took place. ES-P Errored second path For DS1-ESF, this parameter is a count of one-second intervals containing one or more CRC-6 errors or one or more CS events, or one or more SEF or AIS defects. In the case of DS1 SF, this parameter is a count of one second intervals containing one or more FE events, or one or more CS events, or one or more SEF or AIS defects. FC-P Failure count path The number of LOS/LOF/AIS-L (near-end) or RDI-L (far-end) failures. Count is incremented only when the failure goes from off to on. PSC-P PSD-P SAS-P SES-P Protection switch count path Protection switch duration path Severely errored frame/alarm indication signal path Severely errored second path The number of switches between working and protect fibers when in 1+1 linear mode. The number of seconds that the facility has been on the protection fiber. Only applicable if revertive line switching is used. The number of seconds containing one or more SEFs, or one or more AIS defects. For DS1-ESF paths, this parameter is a count of seconds during which at least one of the following has occurred: 320 or more CRC-6 errors, or one or more SEF or AIS defects. For DS1-SF paths, an SES is a second containing the occurrence of eight FEs (if both Ft and Fs bits are considered), four FEs (if only Ft bits are considered), or one or more SEF or AIS defects. 16-8

Table 16-1 Performance Monitoring Codes NonSONET (continued) SEFS-P Severely errored A count of seconds containing one or more SEFs, or one or more frame second path AIS defects. UAS-P Unavailable second path A count of one-second intervals during which the DS1 path is unavailable. A DS1 path is said to be unavailable at the onset of 10 contiguous SESs. The 10 SESs are included in unavailable time. Once unavailable, the DS1 path becomes available at the onset of 10 consecutive seconds with no SESs. The 10 seconds with no SESs are excluded from unavailable time. Monitoring SONET Performance Table 16-2 Performance Monitoring Codes SONET Section CV-S Coding violation Coding Violation - Count of B1 BIP-8 violations. section ES-S Errored second section SES-S Severely errored second section SEFS-S Severely errored frame second section Number of seconds that at any time during the second either at least one BIP error occurred, or an SEF/LOS was present. Number of seconds during which 155 or more BIP errors occurred or an SEF/LOS was present. Number of seconds during which an OOF/LOS occurred. Table 16-3 Performance Monitoring Codes SONET Line CV-L Coding violation Count of B2 BIP-8 violations. line ES-L Errored second line Number of seconds that at any time during the second either at least one BIP error occurred, or an SEF/LOS/AIS-L was present. SES-L Severely errored second line Number of seconds during which 154 or more BIP errors occurred or an SEF/LOS/AIS-L was present. UAS-L Unavailable second line Number of seconds that a line is unavailable. A line is unavailable when 10 consecutive SESs have been detected, and begins at the beginning of the SES sequence (back in time). It is cleared at the beginning of 10 nonsess. FC-L Failure count line Number of LOS/LOF/AIS-L failures. Count is incremented only when the failure goes from off to on. PSC PSD Protection switch count line Protection switch duration line Number of switches between working and protect fibers when in 1+1 linear mode. Number of seconds that the facility has been on the protection fiber. Only applicable if revertive line switching is used. 16-9

Table 16-4 Performance Monitoring Codes Far-End SONET Line CV-L Coding violation far-end line ES-L Errored second far-end line SES-L Severely errored second far-end line UAS-L Unavailable second far-end line FC-L Failure count far-end line Count of B2 BIP-8 violations at the far-end. This is carried in the Remote Error Indicator (REI) overhead byte. Number of seconds that at any time during the second either at least one REI error occurred or an RDI-L was present. Number of seconds during which 154 or more REI errors occurred or an RDI-L was present. Same as the near-end, except it is based on SES-FE. Same as the near-end, but counts RDI-L failures. Table 16-5 Performance Monitoring Codes SONET Path CV-P Coding violation Count of B3 BIP-8 violations. path ES-P Errored second path Number of seconds that at any time during the second either at least one BIP error occurred, or an SEF/LOS/AIS-L/AIS-P/LOP was present. SES-P Severely errored second path Number of seconds during which 2400 or more BIP errors occurred, or an SEF/LOS/AIS-L/AIS-P/LOP was present. UAS-P Unavailable second path Number of seconds that a line is unavailable. A line is unavailable when 10 SESs have been detected, and begins at the beginning of the SESs (back in time). It is cleared at the beginning of 10 nonsess. FC-P Failure count path Number of LOS/LOF/AIS-L/AIS-P/LOP failures. Count is incremented only when the failure goes from off to on. Table 16-6 Performance Monitoring Codes Far-End SONET Path CV-P Coding violation far-end path ES-P Errored second far-end path SES-P Severely errored second far-end path UAS-P Unavailable second far-end path FC-P Failure count far-end path Count of B3 BIP-8 violations at the far-end. This is carried in the remote error indicator (REI) overhead byte. Number of seconds that at any time during the second either at least one REI error occurred, or an RDI-P was present. Number of seconds during which 2400 or more REI errors occurred, or an RDI-P was present. Same as the near-end except it is based on SES-FE. Same as the near-end, but counts RDI-P failures. 16-10