Heating, Ventilation & Air Conditioning Equipment

Similar documents
Heating, Ventilation & Air Conditioning Equipment

2015 C&I HVAC RETROFIT APPLICATION FOR PRESCRIPTIVE REBATES

Mailing address: City: State: Zip: Individual or Sole Proprietor LLC, LLP or Partnership C Corporation S Corporation Trust/Estate Exempt Payee

Creating Efficient HVAC Systems

Appendix C. Minimum Equipment Efficiency Standards

Cooling Efficiency Summary of 60-Day Notice - First Steps

5.6 Technical Specification: Premium Efficiency Electric Air Conditioning Equipment

Achieving ENERGY EFFICIENCY with Standard Air-Conditioning Units. Mike West, PhD, PE Advantek Consulting, Inc

Energy Efficiency. Energy Efficient Home Cooling:

1 Project Information. 2 Building Type. 3 Trade Ally/Contractor Information. Appalachian Power Commercial Program HVAC and VFD Rebate Worksheet

1. What percent of a commercial business s energy usage comes from their HVAC system? A. 13% B. 23% C. 33% D. 43% E. 53%

Commercial Energy Efficiency Program. Save money, reduce energy use and earn incentives. Save money, reduce energy use and qualify for incentives

Florida Power & Light Company. Business Heating Ventilation & Air Conditioning ( HVAC ) Program Standards. Effective: November 9, 2015

ENERGY EFFICIENT HVAC DESIGN FOR WARM-HUMID CLIMATE CLIMATE

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

How To Design A Building In New Delhi

QUESTIONS TO ASK WHEN REPLACING YOUR HVAC TOGETHERWESAVE.COM

Commissioning - Construction Documents (Page 1 of 6)

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

HVAC Systems: Overview

North Carolina Heating and Cooling Equipment Incentive Application

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Massachusetts COOL SMART. RESIDENTIAL CENTRAL AC/DUCTED AIR SOURCE HEAT PUMP Rebate Application

HVAC Efficiency Definitions

Poor Performing AC? High Electric Bills? High Humidity?

HVAC, Motors, VFD, Compressed Air, Refrigeration, MISC, Custom

Air-Conditioning Buying Guide

3/29/2012 INTRODUCTION HVAC BASICS

COMMERCIAL HEATING VENTILATION & AIR CONDITIONING (HVAC)

Glossary of Heating, Ventilation and Air Conditioning Terms

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

Heating & Cooling Efficiency

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

Smart School Symposium Heating Ventilation and Air Conditioning Session HVAC Products. Richard Lord

Residential Air Conditioning. Program Standards

HVAC/PLUMBING INCENTIVE CATALOG

EnergyPro Building Energy Analysis. Assisted Living Building

2015 HVAC Calculator User Instruction Manual

South Carolina Heating and Cooling Equipment Incentive Application

Selection Tips For Air-Conditioning Cooling Systems

Introduction To VRF: System Overview, Applications, & Savings Opportunities

CHAPTER 5 Energy Efficient HVAC Design


HVAC. Combat rising energy costs

Massachusetts COOL SMART

Xcel Business Customers: Program and Rebate Summary

Laboratory Test Report for Fujitsu 12RLS and Mitsubishi FE12NA Mini-Split Heat Pumps

Energy Efficiency Tips for Businesses

ENERGY STAR Program Requirements for Residential Air Source Heat Pump (ASHPs) and Central Air Conditioner Equipment. Partner Commitments.

Optimization of Water - Cooled Chiller Cooling Tower Combinations

HVAC Simplified Approach Option

incentive application for businesses

FTQ. Daikin Inverter Ducted Heat Pump

Ohio Heating and Cooling Equipment Incentive Application

Lower Energy Costs with Rooftop Air-Conditioning Package Units

HVAC Basic Science - System Capacity

Residential electric heating and cooling rebates

AND SIMPLE HVAC SYSTEMS

Evaporative Cooling for Residential and Light-Commercial

South Carolina Heating and Cooling Equipment Incentive Application

Centralized Vs Decentralized Air Conditioning Systems

Large Energy Savings Per Installation VFDs for Large Chillers

Energy Efficiency in Industrial HVAC Systems

How To Buy A Lennox Power System

The Mean Green Cooling MachineTM

Understanding Heating Seasonal Performance Factors for Heat Pumps

Ductless Heat Pumps. Gary Nordeen January

The XP17 provides comfort without comparison.

Impacts of Refrigerant Charge on Air Conditioner and Heat Pump Performance

Life Cycle Costing Analysis of Water-cooled Chillers. Chillventa Nuremburg, Germany

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

The efficient heat pump

BEC 2012 Vs BEC Summary of Major Amendments

9. Heating and Cooling

Section 2: Estimating Energy Savings and Incentives

NOTICE OF INCORPORATION United States Legal Document

Defining Quality. Building Comfort. Precision. Air Conditioning

Laboratory Performance Testing of Residential Window Mounted Air Conditioners

Strategy Guideline: HVAC Equipment Sizing

Benefits of Water-Cooled Systems vs. Air-Cooled Systems for Air-Conditioning Applications

The ABC s of VRF: A Green HVAC Technology An Ideal Green School Solution. Presented by: Fujitsu General America, Inc.

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Maximize energy savings Increase life of cooling equipment More reliable for extreme cold weather conditions There are disadvantages

Heating, Ventilation and Air Conditioning Rebate Catalog Saving energy for a brighter future

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

ULTRA-EFFICIENT HVAC DESIGN AND CONTROL

4. Building HVAC Requirements

New energy evaluating methodology of Air conditioner and Heat pump

DEEMED SAVINGS TECHNICAL ASSUMPTIONS

HIGH PERFORMANCE CHILLED WATER SYSTEMS. EarthWise HVAC. EarthWise HVAC High Performance CHW Plants

Air Side Economizers and Energy Recovery - Improvements and New Regulations. Richard Lord

for Plans Examiners and Building Inspectors

Green Building Handbook for South Africa Chapter: Heating, Ventilation and Cooling Luke Osburn CSIR Built Environment

Dehumidification Frequently Asked Questions

HEATING, VENTILATION & AIR CONDITIONING

Summer cooling savings guidebook

AC System Equipment Specification, Installation and Operational Options for Improved Indoor Humidity Control

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

CHILLER PLANT CONTROL MULTIPLE CHILLER CONTROLS

Easy Save Plus Energy Efficiency Program Paul Geary

Transcription:

FinAnswer Express Utah Incentive Catalog Effective as of May 19, 2012 Heating, Ventilation & Air Conditioning Equipment Rocky Mountain Power provides incentives for many types of energy-efficient technologies. Please read the following sections carefully to ensure that you follow the appropriate steps for securing your incentive. Equipment may be subject to inspection prior to incentive approval. Incentives for additional measures may be available. For more information about the FinAnswer Express program, eligibility requirements, incentive levels or other general inquiries, contact your local equipment dealer or Rocky Mountain Power. You can visit the program website at rockymountainpower.net/wattsmart and submit your inquiry online, or you can call our energy services hotline at 1-800-222-4335. EVAPORATIVE COOLING Measure description: Evaporative cooling equipment utilizes evaporated water to reduce the temperature of air and provide cool air to a space. Evaporative cooling equipment is very effective in warm, arid climates and uses only a fraction of the energy required for air conditioning equipment. Direct evaporative cooling- Air is blown across wet media, causing the water to evaporate. This process cools the air, but also increases its humidity. Indirect evaporative cooling- A two-stage process wherein the evaporation process cools water which is piped to a coil. Air is blown across the coil to cool the air. This method of evaporative cooling can reduce the temperature of supply air without increasing humidity. Applicability: New construction and retrofit installations are eligible. Equipment eligibility: To qualify for the incentives listed below, equipment must be purchased and installed on or after May 19, 2012*, and meet all other program terms and conditions. Evaporative cooling incentives are available for either the direct OR indirect method of cooling. In retrofit applications where mechanical cooling exists, the mechanical cooling for the space must be removed. Evaporative cooling for new construction applications must be standalone units. Incentives are also available for cooling systems that use a combination of direct evaporative, indirect evaporative, and/or mechanical cooling. For incentive information regarding these combination systems, please reference the IDEC section of this catalog. *Incentives may be available for equipment purchased prior to May 19, 2012. For incentive information regarding equipment purchased prior to May 19, 2012, please contact us. 1. Dated sales receipt/invoice for the installed equipment. 2. Manufacturer information documenting the equipment s Cubic Feet per Minute (CFM) capacity rated according to Industry Standard Rating (ISR). 3. A current copy of the Rocky Mountain Power utility bill for the address where the item(s) are installed. If ISR is not available, please contact us for additional eligible ratings. Equipment code Measure description Incentive HVCEVP Evaporative cooling $0.06/CFM FinAnswer Express Utah Page 1 of 11 rockymountainpower.net/wattsmart

INDIRECT-DIRECT EVAPORATIVE COOLING (IDEC) Measure description: Indirect-Direct Evaporative Cooling systems are integrated into air-handling units and use evaporative technologies instead of a chiller to provide cooling for buildings. Evaporative cooling systems work best in dry, arid climates and require much less energy than a chiller. Applicability: New construction and retrofit installations are eligible. Equipment eligibility: Equipment must be purchased and installed on or after May 19, 2012, and meet all other program terms and conditions. IDEC systems must be designed as an integral component of the central air-handling unit and air-distribution system. All components must exceed minimum efficiencies required by International Energy Conservation Code 2009 (IECC 2009). Customer will be required to submit the design parameters of the air-handling system (i.e. supply air flow/temperature, operating set points, fan/pump specifications) and the installed mechanical cooling system. Incentives for IDEC systems are calculated based on climate, building occupancy and cooling system parameters. 1. Dated sales receipt/invoice for the installed equipment. 2. Documentation of IDEC/air-handling unit system parameters, documented by specifying engineer in Table 1. 3. Manufacturer s equipment specification for the mechanical cooling system showing the unit s COP/EER and IPLV ratings at AHRI rated conditions. 4. IDEC calculator savings/incentive summary, supplied by Rocky Mountain Power. Note: Rocky Mountain Power has a calculation software tool available for vendors participating in our Energy Efficiency Alliance (EEA) to calculate project-specific energy savings, project economics and eligible incentives for IDEC projects. Visit our website at rockymountainpower.net/wattsmart for a current list of participating vendors. Equipment code Measure description Incentive* HVCIDC Indirect-Direct Evaporative Cooling $0.12/kWh annual savings + $50/kW average monthly demand savings *To calculate the project savings and incentives, please contact us. Energy and demand savings are subject to Rocky Mountain Power approval. FinAnswer Express Utah Page 2 of 11 rockymountainpower.net/wattsmart

Mechanical Cooling Information IDEC Information (see Footnotes) Customer Table 1. Indirect-Direct Evaporative Cooling System Information Table (Submit copy of table with application) Customer name Facility address Facility city, State, Zip Rocky Mountain Power account number Rocky Mountain Power rate schedule Facility type IDEC system cost ($) Direct evaporative installed? (circle one) YES NO Mechanical cooling installed? (circle one) YES NO Type of Indirect Evaporative Cooling 1 (check one)? Air to Air Indirect (i.e. Crossflow Plate) Coil to Coil Indirect (i.e. Heat Pipe) Water Cooling Tower to Coil None Design air flow (CFM) Design supply air temperature ( F) Supply fan horsepower Design static pressure (inches H 2O) Proposed and/or Existing Type of Mechanical Cooling (check one)? Chilled Water Coil, Water Cooled Chilled Water Coil, Air Cooled DX Refrigerant Coil, Air Cooled None AHRI Mechanical Cooling Nameplate Capacity 2 AHRI Mechanical Cooling Efficiency 2 tons BTU/hr EER COP kw/ton AHRI Mechanical Cooling Part Load Rating 2 IPLV SEER IEER kw/ton 1. For further information or descriptions of indirect evaporative stages, please consult the 2007 ASHRAE Handbook HVAC Applications, Chapter 51. 2. Refer to cut sheets provided by mechanical cooling system manufacturer for information on these parameters. Please circle the correct units associated with the values provided. AHRI = Air-conditioning, Heating, and Refrigeration Institute SEER = Seasonal Energy Efficiency Ratio EER = Energy Efficiency Ratio IEER = Integrated Energy Efficiency Ratio COP = Coefficient of Performance IPLV = Integrated Part Load Value CFM = Cubic Feet per Minute FinAnswer Express Utah Page 3 of 11 rockymountainpower.net/wattsmart

HEATING VENTILATION AND AIR CONDITIONING (HVAC) Measure description: High-efficiency cooling equipment can significantly reduce annual energy costs compared to standard-efficiency units. Incentives are available for high-efficiency air conditioning, heat pump and evaporative cooling equipment. Applicability: New construction and retrofit installations are eligible. Equipment eligibility: Equipment must be purchased and installed, and meet all other program terms and conditions. Incentives of $25/ton, $50/ton and $75/ton for unitary air conditioning/heat pump equipment are only available for equipment purchased and installed on or after May 19, 2012. Incentives may be available for equipment purchased prior to May 19, 2012. For incentive information regarding equipment purchased prior to May 19, 2012, please contact us. Incentives for room air-conditioners used in a business will be approved based on requirements and amounts listed in the Home Energy Savings program. Please visit www.homeenergysavings.net. Incentives are available for equipment meeting or exceeding the efficiency requirements listed in Tables 2, 3, and 4. As noted in the tables below, efficiency ratings will be determined by the standard applicable to the equipment. This directory is available at www.ahridirectory.org Heat pumps must meet both the cooling mode and heating mode efficiency requirements to qualify for per ton cooling efficiency incentives. Packaged Terminal Heat Pumps (PTHPs) can replace electric resistive heating; however, in such cases, electric resistive heating must be removed. 1. Dated sales receipt/invoice for the installed equipment. 2. AHRI certificate or other manufacturer information documenting the efficiency and capacity of the equipment at the applicable standard as listed in Tables 2, 3, and 4. 3. A current copy of the Rocky Mountain Power utility bill for the address where the item(s) are installed. FinAnswer Express Utah Page 4 of 11 rockymountainpower.net/wattsmart

Table 2. A/C Efficiency Requirements, Incentive Levels & Equipment Codes Equipment Type Size Category Equipment Code Sub-Category Unitary Commercial Air Conditioners, Air-Cooled Unitary Commercial Air Conditioners, Water Cooled Unitary Commercial Air Conditioners, Evaporatively Cooled < 65, 000 Btu/hr (single phase) < 65, 000 Btu/hr (three phase) 65,000 Btu/hr and < 135,000 Btu/hr 135,000 Btu/hr and < 240,000 Btu/hr 240,000 Btu/hr and < 760,000 Btu/hr 760,000 Btu/hr < 65,000 Btu/hr 65,000 Btu/hr and < 135,000 Btu/hr 135,000 Btu/hr < 65,000 Btu/hr 65,000 Btu/hr and < 135,000 Btu/hr 135,000 Btu/hr HVACSA1 HVACPA1 Package Systems- HVCSA3 Split Sytems- HVCPA3 HVCUWC HVCUWC Split System Split System Split System and Split System and Split System and Split System and Split system and Split System and Minimum Efficiency Requirement(s) & Customer Incentive CEE Tier 1 CEE Tier 2 $50/ton* $75/ton* 14.0 SEER 15.0 SEER 12.5EER 14.0 SEER 15.0 SEER 11.6 EER 14.0 SEER 15.0 SEER 12.5EER 14.0 SEER 15.0 SEER 11.6 EER 11.5 EER 12.8 IEER 11.5 EER 12.3 IEER 10.3 EER 11.1 IEER 9.7 EER 10.9 IEER 13.8 IEER 13.0 IEER 10.6 EER 12.1 IEER 10.2 EER 11.4 IEER 14.0 EER 13.8 EER 15.1 IEER 13.8 EER 14.6 IEER 14.0 EER 13.8 EER 15.1 IEER 13.3 EER 14.1 IEER 1. Equipment that meets or exceeds the efficiency requirements listed for the equipment category in the above table may qualify for the listed incentive. Equipment must meet both listed efficiency requirements to qualify for the listed incentives. 2. Equipment size categories and capacities are specified in terms of net cooling capacity at AHRI standard conditions as determined by AHRI Standard 210/240 for units < 65,000 Btu/hr, AHRI Standard 340/360 for units 65,000 Btu/hr, and AHRI Standard 310/380 for PTAC and PTHP units. 3. Units rated only with an IPLV may qualify for the listed incentives if the value meets or exceeds the minimum IPLV established as part of the Consortium for Energy Efficiency Commercial Unitary Air Conditioning and Heat Pump Specification effective January 16, 2009. Equipment must be purchased and installed on or after May 19, 2012 to qualify for this incentive. EER = Energy Efficiency Ratio SEER = Seasonal Energy Efficiency Ratio IEER = Integrated Energy Efficiency Ratio IPLV = Integrated Part Load Value CEE = Consortium for Energy Efficiency AHRI = Air Conditioning, Heating, and Refrigeration Institute FinAnswer Express Utah Page 5 of 11 rockymountainpower.net/wattsmart

Table 3. Air-Cooled Heat Pump Efficiency Requirements, Incentive Levels & Equipment Codes Equipment Type Heat Pumps, Air-Cooled (Cooling Mode) Size Category Equipment Code Sub-Category < 65, 000 Btu/hr (single phase) < 65, 000 Btu/hr (three phase) 65,000 Btu/hr and < 135,000 Btu/hr HVCSH1 HVCPH1 Split systems- HVCSH3 Package Systems- HVCSH3 Split System Split System Split system and single package Minimum Efficiency Requirement(s) & Customer Incentive CEE Tier 1 CEE Tier 2 $50/ton* $75/ton* 14.0 SEER 15.0 SEER 12.5 EER 14.0 SEER 11.6 EER 14.0 SEER 14.0 SEER 11.6 EER 11.1 EER 12.1 IEER 15.0 SEER 15.0 SEER 12.5 EER 15.0 SEER 135,000 Btu/hr and Split system and 10.7 EER < 240,000 Btu/hr single package 11.7 IEER 240,000 Btu/hr Split system and 10.1 EER single package 10.7 IEER < 65, 000 Btu/hr HVCSH1 Split system 8.5 HSPF 9.0 HSPF (single phase) HVCPH1 Single package 8.0 HSPF 8.5 HSPF < 65, 000 Btu/hr Split system 8.5 HSPF 9.0 HSPF (three phase) Single package 8.0 HSPF 8.5 HSPF Heat Pumps, Split systems- 47 F db/43 F wb Air-Cooled 65,000 Btu/hr and HVCSH3 outdoor air 3.4 COP (Heating Mode) < 135,000 Btu/hr 17 F db/15 F wb (See Note 2) Package Systems- outdoor air 2.4 COP 135,000 Btu/hr HVCSH3 47 F db/43 F wb outdoor air 3.2 COP 17 F db/15 F wb outdoor air 2.1 COP 86 F Entering Water Heat Pumps, 14.0 EER (Cooling Mode) Water-Source < 135,000 Btu/hr HVCWSH 68 F Entering Water (See note 2) 4.6 COP (Heating Mode) 1. Equipment that meets or exceeds the efficiency requirements listed for the size category in the above table may qualify for the listed incentive. Equipment must meet both listed efficiency requirements to qualify for the listed incentives. 2. Incentives for heat pumps are available per ton of cooling capacity ONLY. No incentives are paid per ton of heating capacity. Heat pumps must meet both the cooling mode and heating mode efficiency requirements to qualify for per ton cooling efficiency incentives. 3. Equipment size categories and capacities are specified in terms of net cooling capacity at AHRI standard conditions as determined by AHRI Standard 210/240 for units < 65,000 btu/hr, AHRI Standard 340/360 for units 65,000 btu/hr, and AHRI Standard 310/380 for PTAC/PTHP units. 4. Units rated only with an IPLV may qualify for the listed incentives if the value meets or exceeds the minimum IPLV established as part of the Consortium for Energy Efficiency Commercial Unitary Air Conditioning and Heat Pump Specification effective January 16, 2009. Equipment must be purchased and installed on or after May 19, 2012 to qualify for this incentive. EER = Energy Efficiency Ratio SEER = Seasonal Energy Efficiency Ratio IEER = Integrated Energy Efficiency Ratio CEE = Consortium for Energy Efficiency IPLV = Integrated Part Load Value HSPF = Heating Seasonal Performance Factor COP = Coefficient of Performance AHRI = Air Conditioning, Heating, and Refrigeration Institute FinAnswer Express Utah Page 6 of 11 rockymountainpower.net/wattsmart

Table 4. Other HVAC Equipment Efficiency Requirements, Incentive Levels & Equipment Codes Equipment Type Packaged Terminal Air Conditioners (PTAC) Packaged Terminal Heat Pumps (PTHP) (Heating & Cooling Mode) Equipment Code HVCPTA HVCPTH Room Air Conditioner RACRES All sizes Heat Pumps, Ground-source or Groundwater-source (Heating & Cooling Mode) See note 2 Ground-source or Groundwater-source Heat Pump Loop Size Category Sub-Category Minimum Efficiency Requirement(s) 8,000 Btu/hr Single package 12.2 EER > 8,000 Btu/hr and < 10,500 Btu/hr Single package 11.9 EER 10,500 Btu/hr and 13,500 Btu/hr Single package 10.7 EER > 13,500 Btu/hr Single package 9.9 EER 8,000 Btu/hr Single package 12.2 EER 3.4 COP > 8,000 Btu/hr and 11.5 EER Single package < 10,500 Btu/hr 3.3 COP 10,500 Btu/hr and 10.7 EER Single package 13,500 Btu/hr 3.1 COP > 13,500 Btu/hr Single package 9.8 EER 3.0 COP Residential used in a business See Note 5 HVCGSH All sizes 77 Entering Water HVCHPL All Sizes Open Loop Closed Loop ENERGY STAR Qualified Customer Incentive $25 / ton $50 / ton $30 each (See note 5) $50 / ton $25/ton 1. Equipment that meets or exceeds the efficiency requirements listed for the size category in the above table may qualify for the listed incentive. Equipment must meet both listed efficiency requirements to qualify for the listed incentives. 2. Incentives for heat pumps are available per ton of cooling capacity ONLY. No incentives are paid per ton of heating capacity. Heat pumps must meet both the cooling mode and heating mode efficiency requirements to qualify for per ton cooling efficiency incentives. 3. Equipment size categories and capacities are specified in terms of net cooling capacity at AHRI standard conditions as determined by AHRI Standard 210/240 for units < 65,000 btu/hr, AHRI Standard 340/360 for units 65,000 btu/hr, and AHRI Standard 310/380 for PTAC/PTHP units. 4. Ground and Water Source Heat Pumps must meet or exceed listed efficiency requirements when rated in accordance with ISO-13256-1 to qualify for an incentive. 5. Incentive will be paid at $/unit as listed in the Home Energy Savings program on date of purchase. Program changes to Home Energy Savings went into effect November 14, 2012. Please see their website for more details regarding incentive offerings and efficiency requirements: www.homeenergysavings.net * Equipment must be purchased and installed on or after May 19, 2012 to qualify for this incentive. EER = Energy Efficiency Ratio COP = Coefficient of Performance PTAC = Packaged Terminal Air Conditioner PTHP = Packaged Terminal Heat Pump FinAnswer Express Utah Page 7 of 11 rockymountainpower.net/wattsmart

WATER-CHILLING EQUIPMENT Measure description: Water-chilling equipment (e.g., chillers) is commonly used to provide cooling for a variety of building types and process loads. Chillers come in many different types (centrifugal, rotary screw, scroll and reciprocating) and typically reject heat either through air-cooled or water-cooled condensers. High efficiency chillers can yield significant energy cost savings compared to standard efficiency units. Applicability: New construction and retrofit installations are eligible. Technical assistance and financial incentives for comprehensive chiller projects are also available through Rocky Mountain Power s Energy FinAnswer program. For more information about Energy FinAnswer, contact Rocky Mountain Power or your vendor before purchasing your equipment. Equipment eligibility: Eligible chiller projects must meet the following requirements: 1. Chillers must exceed the minimum efficiency requirements in Table 5; 2. Chiller must not be a backup service unit; 3. IPLV ratings must account for Variable Frequency Drives (VFD) installed on the chiller compressor, if applicable; 4. Chiller loads must be primarily for comfort cooling (human comfort in occupied spaces). For chillers with loads less than 80% comfort cooling, please contact us before purchasing equipment; 5. Projects must not incorporate significant deviations from the standard chiller operational practices; (e.g., non-standard chilled water or condenser water set points, ice production during off peak hours, changes in chiller sequencing, etc.); 6. Equipment must be purchased and installed, and meet all other program terms and conditions. 1. Dated sales receipt/invoice for installed. 2. Manufacturer s equipment specification sheet showing the unit s Full Load and IPLV ratings and Net Cooling Capacity at AHRI rated conditions (AHRI Standard 550/590). 3. A completed copy of the Chiller Information Table, see Table 5. 4. A current copy of the Rocky Mountain Power utility bill for the address where the item(s) are installed. Equipment code Measure description Incentive* HVCCHL Chiller $0.12/kWh annual savings + $50/kW average monthly demand savings *To calculate the project savings and incentives, complete Table 5 and submit a copy with your application via email to: ut.hvacr@rockymountainpower.net. Energy and demand savings are subject to Rocky Mountain Power approval. FinAnswer Express Utah Page 8 of 11 rockymountainpower.net/wattsmart

Chiller data (see Notes) Vendor Customer Table 5. Chiller Minimum Efficiency Requirements (IECC 2009 Table 503.2.3 (7)) Heat Rejection Type Size Category (tons) Maximum Full Load (kw/ton) Path A Maximum IPLV (kw/ton) Maximum Full Load (kw/ton) Path B Maximum IPLV (kw/ton) Air cooled All < 150 tons 1.255 0.960 NA 1 NA 1 150 tons 1.255 0.941 NA 1 NA 1 Water cooled Reciprocating, Rotary, Screw, or Scroll Centrifugal < 75 tons 0.780 0.630 0.800 0.600 75 tons and < 150 tons 0.775 0.615 0.790 0.586 150 tons and < 300 tons 0.680 0.580 0.718 0.540 300 tons 0.620 0.540 0.639 0.490 < 300 tons 0.634 0.596 0.639 0.450 300 tons and < 600 tons 0.576 0.549 0.600 0.400 600 tons 0.570 0.539 0.590 0.400 1. NA means that this requirement is not applicable and cannot be used for compliance. Table 5. Chiller Information Table (Submit copy of table with application) Customer name Facility address Facility city, State, Zip Rocky Mountain Power account number Rocky Mountain Power rate schedule Facility type Company name Company city Company contact name Chiller is a backup service unit YES NO Chiller cost ($) Cost adder for chiller Chiller heat rejection (circle one) AIR WATER Chiller type (from Table 4) Does the chiller include a VFD (circle one)? YES NO *AHRI chiller capacity (tons) *AHRI chiller full load (COP or kw/ton) *AHRI chiller IPLV (kw/ton) * Refer to cut sheets provided by chiller manufacturer for information on these parameters. AHRI = Air-conditioning, Heating, and Refrigeration Institute COP = Coefficient of Performance IPLV = Integrated Part Load Value COP kw/ton FinAnswer Express Utah Page 9 of 11 rockymountainpower.net/wattsmart

PORTABLE CLASSROOM CONTROL Measure description: 365/366-day programmable thermostats provide the capability to independently program occupied and unoccupied temperature set points for each day of the year. For portable classrooms unoccupied during summer months and occupied on fixed schedules the rest of the year, 365/366-day programmable thermostats reduce unnecessary heating and cooling during unoccupied periods and offer significant energy savings. Applicability: New construction and retrofit installations that meet eligibility requirements may qualify for an incentive. Equipment eligibility: Equipment must be installed and meet all other program terms and conditions. Thermostats must be installed in a portable classroom that is mechanically cooled, unoccupied during summer months and must have either local or remote 365/366 day programmable thermostatic setback capability. 1. Dated sales receipt/invoice for the installed equipment. 2. Manufacturer specification sheet. 3. A current copy of the Rocky Mountain Power utility bill for the address where the item(s) are installed. Equipment code Measure description Incentive DPRGTH 365/366 day programmable thermostat $150 / thermostat OCCUPANCY BASED PACKAGED TERMINAL AC/HP CONTROLS Measure description: Occupancy based Packaged Terminal Heat Pump (PTHP) and Packaged Terminal Air- Conditioning (PTAC) controllers are a combination of a control unit and occupancy based sensor that operate in conjunction to provide occupancy controlled heating and/or cooling. The control unit is operated by an occupancy sensor that is mounted in the room and turns the PTHP/PTAC on and off. Applicability: This incentive is available for installation of new occupancy based control on all sizes of PTHP/PTAC units with no existing occupancy based control. New construction and retrofit applications only are eligible for incentives. Equipment eligibility: Eligible controller units must include an occupancy sensor and have the capability to set back the zone temperature during extended unoccupied periods and set up the temperature once the zone is occupied. To qualify for the incentive listed below equipment must be purchased and installed and meet all other program terms and conditions. 1. Dated sales receipt/invoice for the installed equipment. 2. Manufacturer s equipment specification sheet. 3. Itemized listing of quantity, description, manufacturer, model number and other identifying information as appropriate. 4. A current copy of the Rocky Mountain Power utility bill for the address where the item(s) are installed. Equipment code Measure description Incentive HVCPTC PTAC/PTHP Control $50 / controller FinAnswer Express Utah Page 10 of 11 rockymountainpower.net/wattsmart

PROGRAMMABLE THERMOSTATS Measure description: ENERGY STAR programmable thermostats provide improved control for HVAC zones where occupancy varies according to a predictable schedule. Applicability: Prior to October 30, 2009, incentives were available for customers who replaced a nonprogrammable thermostat with a qualifying ENERGY STAR programmable thermostat in a retrofit application. Incentives were not offered for thermostats installed in new construction applications or where required by International Energy Conservation Code 2009. Equipment eligibility: Incentives are no longer available for ENERGY STAR programmable thermostats. FinAnswer Express Utah Page 11 of 11 rockymountainpower.net/wattsmart