Federation of European Heating, Ventilation and Air-conditioning Associations



Similar documents
Indoor environment and productivity in office environment

There are several types of air cleaning devices available, each designed to remove certain types of pollutants.

i n d o o r a i r q u a l i t y I AQ EN 13779:2007 European standard Camfil Farr clean air solutions

The Finnish Classification of Indoor Environment and Material Emissions

Federation of European Heating, Ventilation and Air-conditioning Associations

Which filter class for supply air is required in a typical HVAC system?

Quick wins for energy savings in buildings

IEQ-15 Air Distribution System

Federation of European Heating, Ventilation and Air-conditioning Associations

Robert McCabe Director, Health Care Solutions HTS Chicago. Improved Air Quality and Energy Efficiency through Air Handler Filtration System Upgrade

3M Personal Safety Division 3M Center, Building W-75 St. Paul, MN, USA

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

Wildfire Smoke and Your Health

INDOOR AIR QUALITY MEASUREMENT IN SERVER AND BATTERY ROOMS IN ICT COMPANIES IN MACEDONIA

Essam E. Khalil

Breathing The Air In Your Home Is Like Living In A Closed Jar. It s Enough To Make You Sick.

Biological Contamination in the HVAC System

"An Office Building Occupant's Guide to Indoor Air Quality"

Why Measure Carbon Dioxide Inside Buildings? By Rich Prill, Washington State University Extension Energy Program

IAQ - indoor ventilation Air contaminants Molds Requirements for growth Health effects Mold prevention - moisture EH&S mold checks & removal

Trane CleanEffects. Patented technology. Superior performance. READ ONLY

Specification. Indoor Air Quality Management

Calculating the cost of HVAC air filters

Educational Performance, Environmental Management, and Cleaning Effectiveness in School Environments

Take Action on Asthma. Environmental triggers of asthma and allergies

A Breath of Poor Air: Inspecting Indoor Air Quality in the Classroom Ashley Schopieray

: Resin Fibre Discs - Aluminum Oxide, Zirconia Alumina

DATA CENTRES. Camfil Farr Segment Brochure Data Centres Camfil Farr - Clean Air solutions

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

ETC -SV. Class 0 oil-free compressed air through catalysis

Asthma and Housing What s the Evidence What Can We Do?

WATER DAMAGE INVESTIGATION. Massachusetts Department of Public Utilities 1 South Station Boston, Massachusetts

INDOOR AIR QUALITY REASSESSMENT. Sgt. William H. Carney Memorial Academy 247 Elm Street New Bedford, Massachusetts

IEQ Management Plan. Denver Museum of Nature and Science ECF Addition

Radford University. Indoor Air Quality Management Plan

Rehva Task Force 12. REHVA Guidebook no.4. Delft University of. Faculty of Architecture

Construction Indoor Air Quality Management Plans for LEED. Matt Gregg, PE, LEED AP

Information paper 20. Prepared by: David Clark. book:

Camfil. Technical Services Bulletin Tools for Schools Filtration for Improved Indoor Air Quality

The Challenges In Monitoring And Control Of Indoor Air Pollution Due To Combustion In Kitchens In Urban And Rural Areas

Air Quality: Public Health Impacts and Local Actions

Indoor air quality monitoring made easy

THE APPLICATION OF OZONE FOR AIR TREATMENT: CASE STUDY OF A BINGO HALL HVAC SYSTEM

How Does Fortron Air Conditioning Treatment Work?

Indoor Air Quality Issues for Hotels

VENTILATION RATES AND IAQ IN EUROPEAN STANDARDS AND NATIONAL REGULATIONS

Thermal and air quality effects on the performance of schoolwork by children. Field intervention experiments

Mold and Mildew Mold and mildew can be detected by sight, smell and touch.

Introduction. Creating Water Quality Confidence. Sample Communication and Guidance - Natural Treatment. Terminology Guidelines

Material Safety Data Sheet 1. PRODUCT AND COMPANY INDENTIFICATION

SAFETY DATA SHEET. Trade name: Master Clear Seal-5 Revised: 5/29/2015

Make your home a healthier home

Indoor Environmental Quality Management Plan

SAFETY DATA SHEET TIDYFOAM E2 HAND CLEANER SANITIZER

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Emission report Honda accord/cu1

1. IDENTIFICATION. US IVD HCCA, portioned BD Bruker US IVD HCCA, Portioned

PEOSH. Indoor Air Quality Training for Asthma-Friendly Schools Part I PEOSH Indoor Air Quality Standard Overview. Eric Weren, MSIH

Indoor-outdoor environmental coupling and exposure risk to extreme heat and poor air quality during heat waves

Material Safety Data Sheet

National Environment Protection (Ambient Air Quality) Measure. Appendix 6

Costs of air pollution from European industrial facilities an updated assessment

Indoor Air Quality- What You Need to Know

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

Energy saving in The air filtration field

3M Personal Safety Division E C O R D. Cartridge. Filter. and. Guide. User Information to Help Optimize Protection

MATERIAL SAFETY DATA SHEET

SAFETY DATA SHEET. 955 Connecticut Ave, Suite 5202 Bridgeport, CT Tel: Date Prepared: July 22, 2015

CARPET CARE PROGRAM. Dustbane Products Limited

Material Safety Data Sheet

Direct Fresh Air Free Cooling of Data Centres

SAFETY DATA SHEET. PC39: Cosmetics, personal care products. This product has no classification under CHIP.

Oakland Unified San Jose Unified Stanford University Santa Ana Unified Newhall Unified Clovis Unified Merced Union High School Grossmont Union High

Technical Cleaning Ó

SAFETY DATA SHEET CLEENOL LIFT WAX FREE POLISH

Public Employees Occupational Safety and Health Program

INDOOR AIR QUALITY POST-OCCUPANCY ASSESSMENT. Massachusetts Department of Revenue 100 TradeCenter, Suite 760 Woburn, MA

Both health-care facility classification and area classification, as per CSA, determine the design requirements.

SECTION 3: COMPOSITION/INFORMATION ON INGREDIENTS 3.1. Substances Not applicable 3.2. Mixture

Glossary of Heating, Ventilation and Air Conditioning Terms

Impacts of air pollution on human health, ecosystems and cultural heritage

Health and the environment: addressing the health impact of air pollution

Basics of HVAC Cleaning

Guidelines for Mold Remediation (Removal)

AccuClean. For Air That s As clean READ ONLY

AUTOMOTIVE GAS OIL. Robert Shisoka Hydrocarbon Management Consultancy

SAFETY DATA SHEET BOSTIK AQUAGRIP 536

Indoor Air Quality. 2. Test and identify sources that contribute to poor indoor air quality.

Safety Data Sheet. Substance. Revision 1.01 modified: 15/03/2011 SECTION 1: Identification of the substance/mixture and of the company

Transcription:

Federation of European Heating, Ventilation and Air-conditioning Associations Address: Rue Washington 40 1050 Brussels Belgium www.rehva.eu info@rehva.eu Tel: +32 2 514 11 71 Fax: +32 2 512 90 62

Use of REHVA Guidebook Power Point Presentations This Power Point Presentation can be freely used for training purposes by REHVA members. It is prepared by the main author to the REHVA Guidebook. Please refer the original author always when making the presentation. Inform REHVA secretariat each time the presentation is used: info@rehva.eu

Air Filtration in HVAC Systems by Jan Gustavsson(ed.), Alain Ginestet, Paolo Tronville Marko Hyttinen

Filtration Guidebook Aimed for designers, manufacturers, installers and building owners in education Discussing pollutants and their effect on indoor quality and the roll of air filters to improve IAQ criteria for selecting air filters efficiency energy (air flow resistance) hygienic consideration life cycle costs (LCC) and environmental impact (LCA) Air filters in real life operation of air filter from air intake to disposal of soiled filters

Work on the Filtration Guidebook Task Force Jan Gustavsson (Ed.) Alain Ginestet Paolo Tronville Marko Hyttinen Sweden France Italy Finland Reviewers Denis Bémer France Carmine Casale Italy Gian Vincenzo Fracastoro Italy Jorma Railio Finland Olli Seppänen Finland Minna Väkevä Finland Acknowledgments Language: Derrick Braham, UK Layout: Jarkko Narvanne, Finland

Contents of the guidebook 1. Air Filtration in a nutshell 2. Terminology 3. Use of air filters - WHY 4. General engineering criteria 5. Filtration principle 6. Particulate air filter test methods 7. Particulate air filters 8. Gas phase air filters 9. Particulate air filters in service 10. Hygienic consideration of air filters 11. Application and selection of air filters 12. Certification of air filters 13. Air filtration check list 14. References

G-FILTER F-FILTER WHY AIR FILTRATION Work Shop Clima 2010 Antalya, 10-05-09 Jan Gustavsson, JG filter Technology Chemical FILTER HEPA, ULPA

Filtration - costs Air flow 1 m 3 /s =1000 L/s Operation time 6000 hours Air Filters F7 + F7 Average pressure drop 120Pa + 100Pa Filter Replacement 2 times/year Filter cost 30 /filter Fan Efficiency 0.5 Energy price 0.1 / kwh Air flow/person 20 L/s People served by 1 m 3 /s 50 Energy (Q Pa T/η fan /1000) 2640 kwh/year Energy cost 264 /year Filter cost 120 /year Total cost 384 /year Cost / person 8 /year 0,15 /week 0,03 /day What are we talking about? A piece of cake? But important

Why air filters Clean industry? Goal = Output Good relationship between cleanliness and quality. Money talks

Why air filters - Offices? Goal = lower costs? Few studies Improved air filtration (First and Rosenfeld 1997) Financial benefits from improved indoor environment exceed the filtration cost by a factor of 20 Reduction of exposure to particles (Bekö et al 2007) Considering pollutants, morbidity, mortality, productivity, working period, cleaning, energy and filtration cost etc. Considering different stakeholders; employers, building owner and society Regardless of perspective, particle filtration is anticipated to lead to annual savings significantly exceeding the running costs for filtration HOWEVER

Why Air filters - Offices? However Economic losses resulting from even a small decrease in productivity caused by sensory pollutants emitted from soiled air filters have the potential to substantially exceed the annual economic benefits of filtration

Why Air filters - Ventilation system Old problem With no cleaning the ventilation will be short-lived Keep the system clean keep the designed Air Flow influence Temperature, RH reduce indoor contaminants from humans, building materials, equipment keep the efficiency of equipment fan, heating, cooling etc. Keep indoor surfaces clean Avoid Microorganisms in the system Remove Outdoor contaminants

Why Air filters - Hygiene (IAQ) Intake of Air and Food - 24 hours Liquid (3kg) Indoors 80% -90% of time Air (20-30 kg) Solid food (1kg) What are the requirements for Air?

WHO - IAQ Healthy indoor air is a human right and all groups, individuals or organizations associated with a building have a responsibility to work to achieve an acceptable air quality Principle 1. The human right to health - everyone has the right to breathe healthy indoor air - influence on quality of life (not only health) Principle 2. Respect for autonomy (self-determination) everyone has the right to expect others to respect their individual judgement in their own evaluation of personal exposure and its effect. Principle 3. do no harm ignorance about indoor air quality is no excuse Principle 4. doing good responsibility to promote good IAQ - Principle 9. We have a responsibility

We know Outdoor pollutants (types, levels and sizes) in most big cities Exposure to urban air pollution is associated with a broad range of acute and chronic health effects 50% of Outdoor airborne pollutants are carried into buildings and have a large impact on Indoor Air Quality The most widespread indoor cause and source for these health impacts is outdoor air Productivity influenced by pollutants Comfort influenced by pollutants No technical problem to take most of the pollutants in air filters

We know - example Fine particles - underestimated health risk Air pollution and mortality in six U.S. cities Mortality rate 1.3 1.2 1.1 1.0 0.9 0 10 20 30 40 Fine particles PM 2.5 (<2.5 µ m), µ g/m 3 Ultra-, Nano- or Fine- particles Clear connection between fine particles and health effects as mortality and respiratory problems Effect on the development of children s lung capacity Underestimated risk (long term) WHO - no harmless concentration limit Official requirements under review Europe and U.S. PM 10 to PM 2.5

Air Filters IAQ problems An Air filter is one component in a ventilation system and cannot contribute to better IAQ by itself, but is a prerequisite for the system and other components to work properly but it can also be a source of IAQ problem Manufacturing Release of particles/gases/microorganisms in operation Decrease in efficiency Smell from removed pollutants Microbial in filters Survive and release VOC(Ketones, alcohols...) Die and release endotoxins, gases/particles Grow and give off microorganisms, spores Replacing filters Dumping/Disposal Global environment (LCA)

Perceived air Several studies have shown filters to have a negative effect on perception of indoor air quality as Influence from new filters is negligible after some days off-gassing Soiled air filters Negative effect of perceived indoor air quality Filter 0.05 olf/m 2 floor area Low pollution office 0.10 People 0.07 Increase sick building syndromes Decrease productivity Release microorganisms, endotoxins etc..

Standards - Recommendations Maximum permissible concentrations of pollutants are set by national regulations and WHO but no standard values, relevant to health protection or limit values based on technical parameters are available for Indoor Air Quality. Comfort criteria are sometimes specified and are normally related to air flow rates, CO 2 concentrations or indirectly by discomfort VDI 6022, EN 13779 and REHVA (No 9) define requirements on air filters and systems to achieve good IAQ and avoid hygienic problems based on some studies and practical experiences No specific criteria for pollutants in IAQ design

AIR FILTERS vs. IAQ There are some recommendations based on experiences and a few studies Filter Class vs. Indoor Air Class EN13779 Indoor Air Quality Outdoor Air Quality IDA 1 (high) IDA 2 (medium) IDA 3 (moderate) IDA 4 (Low) ODA 1 (pure air) F9 F8 F7 F5 ODA 2 (dust) F7+F9 F6+F8 F5+F7 F5+F6 ODA 3 (very high F7+GF *) +F9 F7+GF *) +F9 F5+F7 F5+F6 concentrations of dust or gases) *) GF Gas filter 2

Hygienic aspects - Design F7 F9 + - + Humidity Max. 90 % RH (peaks) Max. 80 % RH (avg. 3 days) Two step filtration is recommended Min. F5 or if possible F7 in the 1 st stage Min. F7 or if possible F9 in the 2 nd stage Min. F7 if only one filter step is used For hygienic reasons the filters should be replaced frequently The first filter step should be replaced after 2000 hours operation The second filter (or the filter in the recycled system) after 4000 h The efficiency may not decrease during operation.

Acceptability of filtered air Chemical reactions with filtrated dust reacts with reactive outdoor air gases such as ozone and oxidation products can be formed, which could explain some of the negative effect of perceived air. Activated carbon is effective against O 3 Some new studies indicate that a combination of particle filters and activated carbon will remove a significant fraction of ozone and improve the acceptability of the filtered air. These filters could replace commonly existing filters and would have particle removal efficiencies comparable to standard filters. They will improve the indoor air quality with little or no modifications to the air handling system.

Air filters- possibilities Protect Ventilation system Keep the function of the system Stop contaminants from entering the system Hygienic reasons Particles Micro-organisms Allergens Carcinogens Gases, ozone Productivity, comfort But; Carefully design and operation is a must

Air Filtration today tomorrow Today - Use existing knowledge Air Filtration Guidebook Efficiency Operation time and conditions Filter and energy design (LCC/LCA) Replacement and disposal Tomorrow Guidelines for Indoor Environment based on pollutants. Comfort criteria and air filters Requirements based on real filter efficiencies. Not on classifications as F7, F8. The meaning of classes will change Air filters in real life Criteria for LCC and LCA calculations Benchmarking of existing installations

Thank you for your attention To order the REHVA guidebooks : www.rehva.eu / section Bookstore or through your national member