Heating, Ventilation and Air Conditioning Periodic Inspection and Maintenance



Similar documents
Training Syllabus to Instruct/Prepare for the ASE Transit Bus HVAC Test

Elements Elements describe the essential outcomes. 1. Prepare to diagnose and repair air conditioning and HVAC system

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Evaluate, Clean, and Tune Guidance

SPECIFICATION TECHNICAL AIR-CONDITIONING UNITS SINGLE AND SPLIT (DUCTED) (AIR COOLED PACKAGED UNIT)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Why and How we Use Capacity Control

16. APTA PR-IM-S Standard for Pantograph Current Collection Equipment Periodic Inspection and Maintenance

Elements Elements describe the essential outcomes.

MINNESOTA WEST COMMUNITY & TECHNICAL COLLEGE COURSE OUTLINE

COMPETENCY ANALYSIS PROFILE Refrigeration and Air Conditioning Systems Mechanic - Branch 1 313A

MIDLAND COLLEGE SYLLABUS DEMR 1323 AUTOMOTIVE HEATING AND AIR CONDITIONING 2-4

Test Code: 8297 / Version 1

Preventive Maintenance. State Energy Assessment Workshop By: DTE Energy Partnership & Services

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Oil and Coolant Circulating Heating System. Model - OCSM

REQUEST FOR BIDS HVAC PREVENTATIVE MAINTENANCE AND SERVICE JANUARY 18, Issued by: NH Liquor Commission. PO Box 503, Concord, NH 03302

Perkins Statewide Articulation Agreement. Documentation item: Secondary Competency Task List Coversheet

High School Graduation years 2013, 2014, Unit/Standard Number

Transport Air Conditioning TRANSPORT AIR CONDITIONING OPERATOR S MANUAL. for SPLIT SYSTEM. Bus Air Conditioning Units.

MAC-120HE-01 Air-Cooled Chiller

Pump Maintenance - Repair

Heating and Air Conditioning

First irst Co. Products

Elements Elements describe the essential outcomes.

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Addendum to Florida Academy Catalog for: HVAC Fundamentals HVAC Advanced Fundamentals

Name: Air Conditioning, Heating and Refrigeration ( )

THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM

17. APTA PR-IM-S Standard for Third Rail Current Collection Equipment Periodic Inspection and Maintenance

, User s Manual

Federal Wage System Job Grading Standard for Air Conditioning Equipment Mechanic, Table of Contents

Action Plan Template HVAC Page 1

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

NSN

Attachment J-C18.1. HVAC Work Instructions

Air Conditioning 101. STN Presentation AC101

ON-VEHICLE INSPECTION

Skills Canada National Competition Instructions and Competition Details 38 Refrigeration and Air Conditioning / Post - Secondary May 27-30,

GLYCOL CHILLER SYSTEM TROUBLESHOOTING 101

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Refrigeration System Installation & Operation Manual

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

It will be available soon as an 8.5 X 11 paperback. For easier navigation through the e book, use the table of contents.

Refrigerant Changeover Guidelines R-22 to R-407C. Leading the Industry with Environmentally Responsible Refrigerant Solutions

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

Refrigeration Basics 101. By: Eric Nelson

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

Air Conditio. Subaru Air Conditioning Systems. End Wrench

Subject: 2005 Air Conditioning Service Guidelines

CEILING CASSETTE FAN COIL UNIT

10 tips for getting more reliability from your air-conditioning system [reliability]

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

CENTRAL HEAT PUMP AND AIR CONDITIONER INSTALLATION

COMMISSIONING OF HVAC SYSTEMS

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

HVAC-02, Air Conditioning Troubleshooting and Repair

Service Guide. Evaporator Coil Cleaning and Condensate Drain Maintenance Guidelines. ORDER No: UN-SVG001A-EN DATE: October 9, 2007

RULE DRY CLEANERS USING SOLVENT OTHER THAN PERCHLOROETHYLENE

LOBOY 16 AIR CONDITIONERS

A brief explanation on how air conditioning works and what terms mean

Air Conditioning. The opportunity for energy efficiency. Low cost actions to reduce energy usage now

Trouble Shooting. Pump

Flushing and Cleaning the A/C System

Troubleshooting HVAC/R systems using refrigerant superheat and subcooling

Classification and Qualification STANDARDS

UA-NJ Air Conditioning & Refrigeration Division Training Curriculum

Troubleshooting Your Refrigerator

Heat Pump Water Heater IOM Manual

Any Service Technician Can Fix It A Good Service Technician Can Figure Out What s Wrong With It.

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

CC145. Air Conditioning System. Operation Manual. CC145 Compact Cooler 4/2013 P.N A

STATEMENT OF WORK FOR MAINTENANCE OF AIR CONDITIONERS

A. The Commissioning Authority (CxA) has been contracted or will be contracted directly with the Owner for this project.

Customized Assessment Blueprint

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

T-Series Air Conditioner T62 Model

REFRIGERATION & AIR-CONDITIONING UNIT IIT KHARAGPUR

Air Conditioning System

AUTOMATIC CONTROL HEATING, VENTILATION AND AIR CONDITIONING SYSTEM

Central Air Conditioning Plants

HEATER, AIR CONDITIONING AND VENTILATION

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

SERVICE BULLETIN AIR CONDITIONER COMPRESSOR FAILURES ALSO SEE BULLETIN #SB3-304AS (SYSTEM CONTAMINATION)

SWIMMING POOL HEAT PUMP

Mechanical Engineering Technician- Plant Technician

DUFFERIN-PEEL CATHOLIC DISTRICT SCHOOL BOARD

ICE AIR. Console Water Source Heat Pump (WSHP) OPERATING & MAINTENANCE MANUAL. Wo r l d C l a s s C o m f o r t.

Aerosphere Midibus. Air Conditioning System. Operation Manual. Aerosphere Midibus 05/2013 P.N A

A Guide to Trouble-Free Cooling Towers

Recommended Practice for Installation of Transit Vehicle Fire Protection Systems

Transcription:

APTA STANDARDS DEVELOPMENT PROGRAM RECOMMENDED PRACTICE American Public Transportation Association 1666 K Street, NW, Washington, DC, 20006-1215 APTA RT-VIM-RP-004-02 Rev 1 First Published: Feb. 2, 2002 First Revision June 28, 2013 APTA Rail Transit Standards Vehicle Inspection and Maintenance Working Group Heating, Ventilation and Air Conditioning Periodic Inspection and Maintenance Abstract: Heating, ventilation and air conditioning (HVAC) are essential for passenger comfort, and in some North American climates, health. This Recommended Practice for inspection of air comfort systems is for all transit systems that consider properly functioning HVAC systems a prerequisite for revenue service. Keywords: air conditioning, light rail, heating, heavy rail, HVAC, periodic inspection and maintenance, ventilation Summary: This Recommended Practice discusses HVAC systems in a general manner, including compressors, motors, fans, filters, condensers, heaters and evaporator coils. It also covers the basic outline for operational checks. Scope and purpose: This Recommended Practice is intended for use by rail transit systems as a guide for developing systematic and comprehensive, equipment specific, HVAC inspection procedures. This document is created for the use of those developing HVAC inspection and maintenance programs for rail transit systems. This Recommended Practice represents a common viewpoint of those parties concerned with its provisions, namely, transit operating/planning agencies, manufacturers, consultants, engineers and general interest groups. The application of any standards, practices or guidelines contained herein is voluntary. In some cases, federal and/or state regulations govern portions of a transit system s operations. In those cases, the government regulations take precedence over this standard. APTA recognizes that for certain applications, the standards or practices, as implemented by individual transit agencies, may be either more or less restrictive than those given in this document. 2013 American Public Transportation Association. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the American Public Transportation Association.

Contents Introduction iii Participants The American Public Transportation Association greatly appreciates the contributions of Daniel Wilson, who provided the primary effort in revising this Recommended Practice. At the time this document was revised, the working group included the following members: Jayendra Shah, Chair Ken Morford, Vice Chair Vicki Porter, Secretary Dave Barber Damian Barnhart, Sherif Bastawros Richard Berk Steve Bethel Jerry Blackman Stephen Bonina Lisa Cobb John Condrasky Richard Curtis Paul Denison Phil Eberl Bill Egan Chris Eichin Marc Gagne Curt Grau John Green Scott Grogan Terry Hildebrandt Ben Holland Paul Jameison Rick Kinding Henry Kolesar Paul Kovacs Brian Ley John MacEwen John Sadorra Richard Seaton George Shaffer John Shea, Jr. Melissa Shurland Michelle Swayzer Clive Thornes Wilson Wallace Michael Wetherell 1. Frequency of conduct... 1 2. Requirements and specific tasks... 1 2.1 Materials... 2 2.2 Tools... 2 2.3 Safety/personal protective equipment... 2 2.4 Training requirements... 2 2.5 Inspection and maintenance... 3 2.6 Correction of deficiencies... 5 References... 6 Abbreviations and acronyms... 6 Summary of document changes... 6 Document history... 6 Project Consultant: Gordon S. Campbell Interfleet Technology Inc. Project Team: Charles Joseph American Public Transportation Association 2013 American Public Transportation Association ii

Introduction APTA RT-VIM-RP-004-02 First Revision June 28, 2013 This introduction is not a part of APTA RT-VIM-RP-004-02 First Revision June 28, 2013, Standard for. This Recommend Practice for Heating, Ventilation and Air Conditioning Periodic Inspection and Maintenance for rail transit vehicles represents a common viewpoint of those parties concerned with its provisions, namely, transit operating/planning agencies, manufacturers, consultants, engineers and general interest groups. The application of any standards, practices or guidelines contained herein is purely voluntary. In some cases, federal and/or state regulations govern portions of a rail transit system s operations. In those cases, the government regulations take precedence over these recommended practices. APTA recognizes that for certain applications, the standards or practices, as implemented by individual rail transit systems, may be either more or less restrictive than those given in this document. This Standard is intended to assist RTS personnel in performing basic maintenance and inspection procedures on rail transit door systems. Since each rail transit rail cars may be different, the procedures and steps described in this document will not necessarily be applied to, nor required for, every RTS maintenance and inspection procedure. APTA recommends the use of this standard by: Individuals or organizations that operate rail transit systems; Individuals or organizations that contract with others for the operation of rail transit systems; and Individuals or organizations that influence how rail transit systems are operated (including but not limited to consultants, designers and contractors). 2013 American Public Transportation Association iii

Heating, Ventilation and Air Conditioning Periodic Inspection and Maintenance 1. Frequency of conduct Periodic inspection and maintenance tasks on the HVAC systems should be performed on regularly scheduled intervals as determined by the rail transit system. The frequency of any task contained within periodic maintenance and inspection should comply with all applicable federal, state and local regulations. Further, in the conduct of a rail transit system s periodic inspection and maintenance programs, frequencies for individual tasks may be established based on a number of additional factors, including but not limited to: OEM-recommended intervals; industry experience; operating environment/conditions; historical data; performance requirements; failure analysis; rail transit system s testing and experience; and Reliability-centered maintenance programs. 2. Requirements and specific tasks NOTE: Release of refrigerant into the atmosphere is illegal. All personnel conducting repair, recovery or evacuation on HVAC systems must possess current EPA certification according to Section 608 of the Clean Air Act of 1990, as amended. WARNING: Only trained and qualified personnel should work on HVAC systems. High voltage, high pressure, rotating equipment, chemical hazards and extremes of temperature are present and can cause serious personal injury. All precautions mandated by the rail transit system and federal, state and local regulatory agencies, including the wearing of personal protective equipment, must be followed. WARNING: Compressed air used for cleaning must be reduced to less than 30 psi, according to OSHA 29 CFR 1910.242b. WARNING: Use only those cleaning products and lubricants proved safe and authorized for use by the rail transit system. Consult original equipment manufacturer (OEM) and Material Safety Data Sheet (MSDS) references for suitability of each application to prevent personal injury and damage to the equipment. 2013 American Public Transportation Association 1

2.1 Materials The following materials are normally required for inspection and maintenance of HVAC systems: OEM and rail transit system manuals, including schematics and drawings; cleaning solutions; lubricants as approved by OEM ; refrigerant as specified by OEM; compressed air; and filters and filter dryers as specified by OEM. 2.2 Tools The following tools are typically required for inspection and maintenance of HVAC systems: recovery/evacuation unit and recovery Cylinder;* refrigeration service gauges;* vacuum pump; mechanics toolbox; special tools; Volt Ohm Meter* electronic, ultrasonic or ultraviolet leak detector, or other leak identification device;* air flow hood, anemometer or other velocity/volume-measuring device;* portable test unit; scale, to weigh quantity of refrigerant installed and/or recovered; and temperature measuring device. NOTE: Tools marked with an asterisk require periodic calibration as specified by the rail transit system s practices. 2.3 Safety/personal protective equipment Appropriate personal protective equipment, meeting minimum ANSI standards and as required by the rail transit system, shall be worn at all times in the performance of these inspection and maintenance tasks. 2.4 Training requirements Rail transit systems and/or their maintenance contractors should develop and execute training programs that provide employees with the knowledge and the skills necessary to safely and effectively perform the tasks outlined in this Recommended Practice. These programs should include but not limited to the following: Fundamentals of Refrigeration On Car System Operation Description, Location, Operation, and Function of each Line Replaceable Unit (LRU) System Evacuation and Dehydration System Pump-Down and Charging Principals of HVAC Controls Safety Devices and Lockouts HVAC Mechanical and Electrical Schematics Preventive Maintenance Troubleshooting and System Calibration 2013 American Public Transportation Association 2

Corrective Maintenance Maintenance and Operation Safety Hazards EPA 608 Certification Training APTA RT-VIM-RP-004-02 First Revision June 28, 2013 2.5 Inspection and maintenance The following suggested inspection and maintenance procedures are intended for use in conjunction with the OEM s recommended inspection and maintenance procedures. In the event of a conflict between this Recommended Practice and the manufacturer s recommendations, the manufacturer s recommendations should prevail. 2.5.1 System de-energized inspections Microprocessor fault data logs and vehicle maintenance history files should be available and reviewed before work begins. Diagnostic information can pinpoint components that are repeatedly failing, perhaps intermittently. Troublesome components can be identified and receive more detailed inspection and functional checks. 2.5.1.1 General mechanical inspections a. Inspect housing latches/fasteners for damage and security. Replace/repair as required. b. Inspect housing seals for integrity and air bypass. c. Inspect housing, panels and structure for corrosion. d. Inspect fresh air and return air filters, louvers and grilles. Clean or replace according to OEM instructions or rail transit system requirements. e. Inspect all mechanical mounting components for damage and security. 2.5.1.2 Compressor a. For open-drive compressors, check the drive/motor coupling for security, proper alignment and excessive wear and play. b. Verify oil level in accordance with OEM procedures. c. For open drive compressors, check compressor shaft seal for refrigerant leakage. Repair or replace when leakage exceeds OEM recommendations. d. Check for refrigerant leakage on compressor fittings, gaskets and seals. e. Refer to APTA Recommended Practice APTA RT-RP-VIM-010-02, Electrical Motor Periodic Inspection and Maintenance, for motor inspection. f. Extract oil sample where possible and acid test for proper color and acid content. 2.5.1.3 Piping a. Inspect piping for dirty or oily areas. Clean those areas and then use a leak detector to check for leaks. Repair as required. b. Check indicator on filter/dryer and replace dryer if it indicates moisture in the system. c. Clean all drain pans, drain pipes and nozzles. Inspect for leaks and repair as necessary. d. Ensure that all drains are free-running. e. Check condition of vibration-eliminator piping. f. Ensure that expansion valve sensing bulbs are in correct location and in firm contact with evaporator discharge line, where possible without removing insulation. g. Check for integrity and proper installation of piping insulation. 2013 American Public Transportation Association 3

2.5.1.4 Condensers and evaporators a. Clean the condenser and evaporator coils and fins with compressed air according to 29 CFR 1910.242(b), or use an appropriate cleaning solution. If desired, the effectiveness of cleaning can be measured as a function of pressure drop across the condenser; rail transit system experience and OEM recommendations can establish the appropriate level. b. Inspect for damage to fins and coils, and evidence of leaking. Repair per OEM instructions. c. Clean and inspect all fan blades. Check that fans rotate freely and without obvious bearing noise. d. Clean evaporator drain pans and drain lines. 2.5.1.5 Electrical a. Inspect wiring for chaffing or other damage, and tighten any loose connections. b. Inspect fusible link for continuity and/or damage. c. Verify operation of evaporator airflow switch device d. If applicable, inspect all motor commutator and brushes and brush holders, replace as necessary. e. Lubricate motors, if required. f. If heaters are checked with a resistance test, verify resistance values. Check that properly rated fuses are installed in the heating system. Verify that heating resistance element mounting, insulators and hardware are properly installed and not damaged. g. Inspect all contactors, contactor coils for cleanliness and integrity. h. Perform insulation resistance test on high-voltage circuits. i. Inspect contactor tips for signs of arcing. j. Refer to APTA Recommended Practice APTA RT-RP-VIM-010-02, Electrical Motor Periodic Inspection and Maintenance, for motor inspection. 2.5.2 System-energized functional tests 2.5.2.1 Controller a. Verify correct controller software version is installed. b. Verify correct operation of controller using an operational test that verifies appropriate control modes. c. Where hard logic is used, check contactor operation. 2.5.2.2 Refrigerant circuit operation a. Perform an operational (functional) check of the HVAC system. Monitor gauge pressures versus vehicle temperature to determine acceptable operation. This procedure is done by cycling the HVAC unit through its various cooling modes by simulating ambient and in-car temperatures through the use of a computer or other portable test unit. b. Verify that airflow is sufficient. c. Check refrigerant level in receiver sight glass, if unit is so equipped. d. Verify proper condensate flow. e. Verify pump down on reciprocating compressor systems. f. Verify superheat at evaporator suction line, if equipped with adjustable thermal expansion valves. g. Verify no flash gases (bubbles) in liquid line sight glass, if unit is so equipped. NOTE: Flash gases may be indicative of a low refrigerant charge or a piping restriction. h. Check proper pressure switch operation, as required. i. Inspect for icing along suction lines, thermal expansion valves and at the evaporator. 2013 American Public Transportation Association 4

2.5.2.3 Heaters a. Verify that all heaters are operational and are heating the air as required. This may be done by checking heater resistance when not in operation, by checking power consumption in operation, or by checking the temperature near the heater. b. Check resistance to ground. c. Verify heater contactor operation. 2.5.2.4 Mechanical a. Check for excessive vibration or noise while in operation. b. Check compressor oil for proper color and level. Perform acid test as required. c. Check unloaders for proper setting and operation. 2.6 Correction of deficiencies Any deficiencies uncovered during the inspections required in Section 2.5.1 through 2.5.2 should be corrected and documented in accordance with rail transit system procedures and OEM recommendations. 2013 American Public Transportation Association 5

References American Public Transportation Association Recommended Practice: APTA RT-VIM-RP-010-02, Electrical Motor Periodic Inspection and Maintenance (Document was previously numbered as APTA RT-RP-VIM-0-02) Code of Federal Regulations, 29 CFR 1910.242(b), Compressed Air Used for Cleaning. U.S. Environmental Protection Agency, Clean Air Act (CAA) of 1990, as amended, Section 608. Abbreviations and acronyms ANSI American National Standards Institute CAA Clean Air Act CFR Code of Federal Regulations EPA United States Environmental Protection Agency HVAC heating, ventilation and air conditioning MSDS Material Safety Data Sheet OEM original equipment manufacturer OSHA Occupational Safety and Health Administration psi pounds per square inch Summary of document changes 1. Document formatted to the new APTA standard format. 2. Sections have been renumbered and moved around. 3. Two new sections added, Summary of document changes and Document history 4. Some global changes to section headings and numberings resulted when sections dealing with references and acronyms were moved to the end of the document and other cosmetic changes, such as capitalization, punctuation, spelling, grammar and general flow of text. 5. Changes in the following sections: a) 2.1 Materials added references to OEM b) 2.2 Tools added Volt Ohm Meter c) 2.4 Training Requirements listing of areas of training programs d) 2.5.1.5 Electrical added verify operation of airflow switch e) 2.5.2.4 Mechanical added perform acid test Document history Document Version Working Group/Task Force Vote Public Comment/ Technical Oversight CEO Approval Policy & Planning Approval Publish Date First published July 2001 - - Jan 24, 2002 Feb 2002 First revision 1 st Qtr 2013 March 2013 May 14, 2013 June 14, 2013 June 28, 2013 2013 American Public Transportation Association 6