The Florida Building Code



Similar documents
Hurricane Damage. How Wind Forces Affect Homes

The Florida Building Code

SINGLE FAMILY RESIDENCE HURRICANE MITIGATION APPLICATION

APPLICATION INFORMATION FOR RESIDENTIAL ROOFING AND RESIDENTIAL ROOFING PACKET

providing documentation that validates the year of construction. Acceptable documents include

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

IGNITION-RESISTANT CONSTRUCTION: THE WHY BEHIND THE WHAT

Florida Building Code, 5th Edition (2014) June 30 th, 2015

Detached accessory structures that contain no conditioned floor area are exempt.

Commercial Residential Model Reviews

Protecting YOUR NEW HOME FROM Wind Damage

REQUIREMENTS FOR SUBMITTING PLANS FOR NEW CONSTRUCTION

Asphalt Shingle Application Requirements

Development Services City of Lawrence, KS

CITIZENS PROPERTY INSURANCE CORPORATION. STREET ADDRESS: Gulf Blvd, Maderia Beach, FL Six story masonry residence

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Repairs, Remodeling, Additions, and Retrofitting

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

Wind Mitigation Discount Plan

ISO Types 1-6: Construction Code Descriptions

Wind Mitigation Inspection

Estimated Cost of Repair

Mark Cramer Inspection Services, Inc.

Protecting Your Home From Hurricane Wind Damage

Appendix B Florida Building Code Building Section Public Shelter Design Criteria

Informational Bulletin

FLORIDA PUBLIC HURRICANE LOSS PROJECTION MODEL. Engineering Team Final Report. submitted to: Dr. Shahid Hamid. Director

2008 Florida Residential Wind Loss Mitigation Study

Damage Assessment of Woodframe Residential Structures in the Wake of Hurricane Katrina

How To Make A House Safe

Advanced Wind Mitigation Methodologies Pt. 2 Online Retrofit Course. Section 1: Introduction

FLORIDA PRODUCT APPROVAL

Pre-Drywall Inspection Report

Wind vs. Water and Unique Monroe County Mitigating Factors for Wind Damage

Architectural Inspection Site Structures

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Building Condition Assessment Report

SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE NOTICE TO PROPERTY OWNER

PLEASE RETURN DENIAL COMMENTS WHEN RESUBMITTING PLANS*

Basic Assessment and Characterization of Damage

SECTION 3 ONM & J STRUCTURAL ANALYSIS

PLAN SUBMITTAL INFORMATION

CITY OF FLORIDA CITY Building and Zoning Department 404 West Palm Drive Florida City, FL ROOFING PERMIT APPLICATION

South Carolina Department of Insurance

ELIGIBLE REPAIR PROJECT PARAMETERS

CITY OF WHITE BEAR LAKE BUILDING INSPECTION DEPARTMENT 4701 Highway 61 White Bear Lake, MN Fax: Re-Roofing: Asphalt Shingles

Residential Building Permits

Florida Building Code Advanced Training: Residential Roofing Shingles

Chapter 6 ROOF-CEILING SYSTEMS

Text Box 1 Important Actions, Questions and Constraints to Consider on Standards and Vulnerability

Substantial Improvement/Damage (FEMA 50% Rule) Frequently Asked Questions and Information

Protecting Roofing Systems Against Windstorm Damage

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

2014 FLORIDA BUILDING CODE

RESIDENTIAL ROOF PERMITTING A REFRESHER WORKSHOP September 11, 2014

Shingle Roofing: What s below the surface is important

Patio Covers / Carports

Sample Drawing Package for One and Two Family Dwelling Applications

Replacing your condominium windows and doors

CITIZENS PROPERTY INSURANCE CORPORATION BUILDING TYPE II AND III MITIGATION VERIFICATION AFFIDAVIT

CLOSED-CELL SPRAY FOAM Resisting Wind Uplift in Residential Buildings

Notice to Property Owners

Metal Roof Systems in High-Wind Regions

ROOF CONSTRUCTION Roof Styles Gable Roof Hip Roof Gambrel Roof

Florida Building Code Cost and Loss Reduction Benefit Comparison Study

Protecting Your Home from Wind Damage

Structural Assessment Report

Vision Home Inspection

CERTIFICATE OF COMPLIANCE Prescriptive Residential Re-roof Project Name:

A study of hurricane mitigation cost effectiveness in Florida

Building Construction and Development in Norristown: A User s Guide to the Land Development and Building Permit Process 1/25/11

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Materials and Colors

THIS GUIDE WAS PREPARED BY THE CYCLONE TESTING STATION WITH SUPPORT FROM NORTHERN TERRITORY, QUEENSLAND AND WESTERN AUSTRALIAN GOVERNMENTS

8/18/14. Introduction to. Framing. Terminology and Concepts

Above the Flood: Elevating Your Floodprone House. Federal Emergency Management Agency. Federal Emergency Management Agency

Page & Turnbull imagining change in historic environments through design, research, and technology

Building Construction. Structural Systems 1. Load-bearing wall construction 2. Skeleton framing 3. Combination of the two

SUBSTANTIAL IMPROVEMENT OR SUBSTANTIAL DAMAGE APPLICATION REVIEW

Fortified For Safer Living

FORTIFIED Home. The key to resilient communities

Larry Haight's Residential Roofing Co, Inc NE 95th Street Redmond, Washington Phone: (425) Fax: (425)

Walls. Add Strength and Water Resistance When Repairing Your. Replace damaged framing members when walls are open

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

Transcription:

The Florida Building Code Florida s Response to Hurricane Risk Rick Dixon Florida Building Commission

Florida Building Commission Architect Structural Engineer Mechanical Engineer Fire Protection Engineer AC or Mechanical Contractor Electrical Contractor Plumbing Contractor General Contractor Roofing Contractor Residential Contractor Swimming Pool Contractor Manufactured Building Rep Building Products Manufacturer Green Building Industry Rep Governor Appointed Chairman Three Municipal Building Officials One County Building Official Department of Financial Services Representative Persons with Disabilities Rep League of Cities Representative Building Owners and Managers Rep Insurance Industry Representative Public Education Representative

The Commission is Responsible for: Updating the Florida Building Code Triennially Interpreting the Code Maintaining a Product Approval System

Florida Building Code Includes Multiple Volumes Building Residential Existing Building Plumbing Mechanical Fuel Gas Electrical Energy and Accessibility Coordinated with the Florida Fire Prevention Code

Code Characteristics Based on National Model Codes The International Code Council s family of codes Updated every 3 years Can be Amended at any time to fix Glitches Modified for Florida Specific Needs Numerous Additions for Hurricane Protection Primary Wind Engineering Standard, ASCE 7 2005 Alternative Design Methods Derived from ASCE 7 are allowed

Hurricanes and Florida Building Codes 1940 s 50 s hurricanes led to the South Florida Building Code in Dade and Broward Counties 1960 s hurricanes and 1970 s booming growth led to the state mandate for local adoption and enforcement of the State Minimum Building Code 1970 s 80 s hurricanes and coastal environmental concerns led to the hurricane protection specific Coastal Building Code 1990 s hurricanes led to first statewide wind engineering code and the consensus exercise that authorized the Florida Building Code, the first State controlled code 2002 the State developed Florida Building Code preempted local codes

Building Codes Before 1993 Before the mid 1970 s building codes were a local option 1974 Florida law required local adoption, amendment and enforcement of State selected model codes State Minimum Building Code Two main codes were adopted and enforced locally South Florida Building Code Dade and Broward Counties Standard Building Code Everywhere Else Hurricane protection requirements were derived empirically and provided prescriptive specifications for indigenous construction types

1986 Coastal Building Zone and Code Coastal beach and dune systems were damaged by construction practices Rapid development of coastal land increased risks to the public and local, state and federal governments The first engineering design based codes were applied to the coastal rim requiring elevated and wind resistant buildings The State regulated part of the zone and local governments the remainder The State began development of a deemed to comply prescriptive standard based on the engineering standard

1992 Hurricane Andrew! The first major test of the locally managed building code system and non indigenous construction of the 1970 80 s boom The best hurricane code in the USA failed! Reaction was swift and demonstrative statewide

Miami Dade Response to Andrew Improved Roof System Requirements 1993 Major structural and building component upgrades 1994 Engineered design using ASCE 7 1988 required New building product wind testing standards implemented Building Product Approval System Expanded and Enhanced

State of Florida Response to Andrew 1993 New law requiring Licensing/Certification of Local Government Building Code Enforcement Officials Florida Board of Building Codes and Standards Adopts the Deemed to Comply Standard initiated in 1986 as the Minimum Standard for Wind Design Throughout the State Creating the First Wind Engineering Based Design Requirements in Florida building codes outside Dade and Broward

State of Florida Response to Andrew The Move to Take Over Building Codes from Local Control 1994 Preliminary study on a single State controlled code 1996 Florida Building Code Study Commission began work 1998 Study Commission recommendations adopted in law 2000 Legislature reviews Florida Building Code, modified the Code and authorized implementation 2002 All legal challenges resolved, the 2001 FBC takes effect March 1 2004 Hurricanes Charley, Frances, Jeanne and Ivan

2002, Florida Building Code Improvements Higher design wind pressures in South Florida and most coastal areas Wind borne debris protection of windows in all coastal areas and South Florida Improved roof covering systems requirements Product approval system to ensure products comply with wind resistance and impact resistance requirements Improved window performance labeling requirements to improve enforcement of the code

Window Protection Requirement

Impact of Pre 1974 Florida Codes Codes such as the South Florida Building Code were developed empirically and were appropriate to the construction practices they were based on. However, they are reactive and only adjusted for new construction methods after hurricanes revealed failures

Impact of Post 1993 Florida Codes Overall Most Catastrophic Structural Failures of Buildings Due to Wind Pressure Were Resolved Gable end failures were resolved with bracing criteria Wood frame wall racking failures were resolved by bracing with a complete layer of plywood sub sheathing Pulling apart at roof to wall, wall to wall and wall to foundation intersections were resolved by metal connector requirements for wood walls and reinforced concrete column and beam requirements for concrete block walls to create a continuous load path Roof deck detachment failures were resolved by enhanced nailing requirements

2004 and 2005 Hurricane Seasons Charley Jeanne Francis Ivan High Winds, Fast Moving, Moderate Rain Moderate Winds, Slow Moving, Heavy Rain Moderate Winds, Slow Moving, Heavy Rain Coastal High Winds and Storm Surge Event Wilma Dennis Moderate Winds, Fast Moving, Moderate Rain Coastal Moderate Winds and Storm Surge Event

2004 Hurricanes

Lessons for Post 1993 and Pre Florida Building Code Houses Catastrophic structural failures generally solved HOWEVER Building components and claddings continued to fail Roof coverings Asphalt Shingle and Roof Tiles Exterior Insulation and Finish Systems EIFS Vinyl Siding Windows and Entry Doors Garage Doors Aluminum screen enclosures and structures continued to fail

Lessons for 2001 Florida Building Code Houses Successes: No Catastrophic Structural Failures Windows and Doors Resisted Wind Pressures Better Garage Doors Resisted Wind Pressures Better Window Protection Reduced Wind Borne Debris Damage Shingle Roof Covering Performed Better Metal Roof Coverings Performed Well Overall, the Building Structure Performed Well in High Winds and Components and Cladding Wind Resistance Were Improved HOWEVER Several Problems Were Identified

Lessons for 2001 Florida Building Code Houses Problems Identified: Roof Tile Detachment at Hips, Ridges and Eaves Extensive Soffit Damage Better Aluminum Screen Enclosure Performance but Still Failures Wind Borne Debris Water Intrusion At the interface of first story masonry and second story wood walls At attic vents At the interface of windows and doors to walls Through windows Through masonry walls

Florida Building Code Improvements 2004 2007 Improved requirements for wood to masonry wall interfaces Allow unvented attics under certain conditions Improved requirements for roof tile attachment Adopt standard that rates asphalt shingles based on wind speed Require improving roof deck nailing when reroofing Adopt wind pressure criteria for soffits Adopt requirements for labeling of windows, garage doors and shutters for wind pressure Eliminate partially enclosed design option Amend panhandle wind borne debris requirement

Research and Future Code Improvements Improved Window Water Leakage Standard Improved Window/Wall Interface Construction Criteria Improved Soffit Installation Requirements Soffit Water Leakage Test Standard Improved Understanding of Wind Borne Debris Characteristics and Window Protection Systems Capacities Improved Analytical Models for Wind Effects in Treed and Open Terrain and at the Water to Land Interface Improved Analytical Models for Wind Borne Debris Characteristics and Impacts Wind Tunnel Testing for Wind Pressure Characteristics on Structures Large Scale and Full Scale Testing of Building Assemblies and Buildings Advancement of Roof Covering Systems Attachment and Wind Resistance Improved Prediction of Wind Speeds for Building Design Standards

Impact of Florida Building Codes Mean Loss vs Year Built Mean (A Loss/ A Cov. Limit, %) Mean (A Loss/ A Cov. Limit, %) 25 A l Wind Speeds 100-120 mph 20 80-100 mph > 120 mph 15 10 5 0 1950 1955 1960 1965 1970 1975 1980 1985 1990 1995 2000 Year Built 1.2 80-100 mph 1.0 0.8 0.6 0.4 0.2 Mean (A Loss/ A Cov. Limit, %) A Loss/ A Cov. Limit, %) 0.50 0.45 All Wind Speeds 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00 1950 1955 1960 1965 1970 1975 1980 1985 1990 1995 2000 Year Built There is a noticeable reduction in loss for recently built homes. >2002 5 100-120 mph 4 3 2 0.0 1950 1955 1960 1965 1970 1975 1980 1985 1990 1995 2000 Year Built 0 1950 1955 1960 1965 1970 1975 1980 1985 1990 1995 2000 Year Built 25 > 120 mph Mean (A Loss/ A Cov. Limit, %) 20 15 10 5 >120 mph winds include some envelope failures. 0 1950 1955 1960 1965 1970 1975 1980 1985 1990 1995 2000 23 Year Built

Summary The State Building Codes have a dramatic impact on reducing hurricane damage and losses Beginning with the first wind engineering standards based codes in the mid 1990 s and improving steadily over time Catastrophic structural failures as seen in Hurricane Andrew have been solved Performance of roofing systems that reduce water damage have improved significantly Other components and cladding resistance to wind have improved and steps have been taken to improve resistance to water intrusion Component and cladding performance can be improved more with improved understanding of wind characteristics and its effect on building surfaces Research and code evolution are continuing