Technical Note: Comparing R407C and R410A as Alternatives for R22. A Technical Note from the Experts in Business-Critical Continuity



Similar documents
Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity

How To Save Energy On A Power Supply

DCIM Readiness on the Rise as Significant Data Center Capacity Remains Unused. A Research Report from the Experts in Business-Critical Continuity TM

Protecting Our Information, Protecting Our Resources

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

Proper Application of 415V Systems in North American Data Centers. A White Paper from the Experts in Business-Critical Continuity

Liebert : The Right Cooling For IT Environments. Precision Cooling For Business-Critical Continuity

The Effect of Regular, Skilled Preventive Maintenance on Critical Power System Reliability

Directed Circuits Meet Today s Security Challenges in Enterprise Remote Monitoring. A White Paper from the Experts in Business-Critical Continuity TM

Environmental and Safety Impacts of HFC Emission Reduction Options for Air Conditioning and Heat Pump Systems

RS-44 (R424A) : Q & A

Protecting The Critical IT Infrastructure of the United States

Secure Remote Monitoring of the Critical System Infrastructure. An Application Note from the Experts in Business-Critical Continuity

How To Run A Data Center Efficiently

Low-GWP Refrigerants for Air Conditioning and Refrigeration Applications. Samuel F Yana Motta

Data Center Precision Cooling: The Need For A Higher Level Of Service Expertise. A White Paper from the Experts in Business-Critical Continuity

Refrigerants for Residential and Commercial Air Conditioning Applications

It s Your Choice Retrofitting Your Car s A/C System 1EPA. 2 Printed on paper that contains at least 20 percent postconsumer fiber.

Power Management Strategies for High-Density IT Facilities and Systems. A White Paper from the Experts in Business-Critical Continuity TM

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

How To Improve Energy Efficiency In Data Center Management

R-32. The next generation refrigerant for air conditioners and heat pumps

A Performance Comparison of Vapour Compression Refrigeration System Using Eco Friendly Refrigerants of Low Global Warming Potential

SmartDesign Intelligent, Integrated Infrastructure For The Data Center. Solutions For Business-Critical Continuity

R407C GUIDELINES FOR UTILIZATION OF. DATE: August 2009 REFERENCE DOCUMENT NO. RD-0005-E GUIDELINES FOR UTILIZATION OF R407C

Enterprise Remote Monitoring

Liebert CW kW Chilled Water Cooled Precision Air Conditioning For Data Centers

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment. Precision Cooling For Business-Critical Continuity

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM WITH R404A, R407C AND R410A

RS-52 (R428A) RS-52: PHYSICAL PROPERTIES RS-52 R502 Molecular weight Temperature glide o C Boiling point (1 atm)

Mohan Chandrasekharan #1

Engineers Newsletter. HVAC Refrigerants: A Balanced Approach. providing insights for today s hvac system designer. volume Refrigerant History

RS-24 (R426A): Q & A

Data Center Infrastructure Management Managing the Physical Infrastructure for Greater Efficiency

DISCONTINUED PRODUCT. Infrastructure Management & Monitoring For Business-Critical Continuity. Liebert icom-do. User Manual

Engineering White Paper UTILIZING ECONOMIZERS EFFECTIVELY IN THE DATA CENTER

Data Center Rack Systems Key to Business-Critical Continuity. A White Paper from the Experts in Business-Critical Continuity TM

2010 Report of the Refrigeration, Air Conditioning and Heat Pumps Technical Options Committee (RTOC)

The phase out of R22. Phase out of HCFCs

Performance of R-438A in R-22 Refrigeration and Air Conditioning Systems

HCFC phase-out has started.

Liebert IntelliSlot Web Cards

Repair, Retrofit, or Replace Choices for Servicing R-22 Equipment

Virginia Tech. Background. Case Summary. Results

Refrigeration and Air Conditioning with Reduced Environmental Impact

THE REPLACEMENT OF R-22

Ten Steps to Increasing Data Center Efficiency and Availability through Infrastructure Monitoring

REFRIGERANT REFERENCE GUIDE

THEORETICAL AND EXPERIMENTAL EVALUATION OF AUTOMOBILE AIR-CONDITIONING SYSTEM USING R134A

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

REFRIGERANT 410A. Refrigeration Service Engineers Society 1666 Rand Road Des Plaines, Illinois Information compiled by Frank Prah, CMS

Commercial refrigeration has been in the environmental. Refrigerant. as a. Basics Considerations PART 1:

Part A: Fluid properties

PG Student (Heat Power Engg.), Mechanical Engineering Department Jabalpur Engineering College, India. Jabalpur Engineering College, India.

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

Five Strategies for Cutting Data Center Energy Costs Through Enhanced Cooling Efficiency

Liebert HPM Designed for top level performance and reliability. Precision Cooling for Business-Critical Continuity

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

Industry insight. Refrigerant gases: an industry in transition.

IT White Paper IP TELEPHONY AND RELIABILITY: PROTECTING MISSION-CRITICAL PHONE SYSTEMS FROM POWER THREATS

Low GWP Replacements for R404A in Commercial Refrigeration Applications

Data Center Users Group Special Report Inside the Data Center 2008 and Beyond. A White Paper from the Experts in Business-Critical Continuity TM

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

R-32. The next generation refrigerant for air conditioners and heat pumps. Superior energy efficiency and low GWP

NFPA 70E 2012 Rolls Out New Electrical Safety Requirements Affecting Data Centers

Substitute Aerosol Solvents and Propellants Under SNAP as of August 10, 2012 SNAP Information:

Reference Guide: SmartDesign Approach: Common Data Center Challenges:

Economizer Fundamentals: Smart Approaches to Energy-Efficient Free-Cooling for Data Centers

Knürr DCL Modular Rack Cooling from 6 kw to 60 kw

IT White Paper MANAGING EXTREME HEAT: COOLING STRATEGIES FOR HIGH-DENSITY SYSTEMS

SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

Liebert CRV Row-Based Cooling Intelligent Precision Cooling For Data Center Equipment

The EC Ozone Regulation. Legislative Update and Strategies for HCFC Phase-out

Liebert. Liebert Universal Monitor Monitoring, Control And Remote Communications For Critical Applications

News in Data Center Cooling

R441A An EPA- Approved Multi-blend Pure Hydrocarbon Refrigerant

HFCS, REFRIGERATION AND AIR-CONDITIONING: MINIMISING CLIMATE IMPACT, MAXIMISING SAFETY

Power and Cooling Best Practices for IP Communications. A White Paper from the Experts in Business-Critical Continuity

STATE UNIVERSITY OF NEW YORK COLLEGE OF TECHNOLOGY CANTON, NEW YORK COURSE OUTLINE. ACHP 104 Refrigeration & Air Conditioning Service II

Automobile Air Conditioning Primer

Capacitors Age and Capacitors Have an End of Life. A White Paper from the Experts in Business-Critical Continuity TM

Refrigerant Update and Beyond. Stephen Niles Refrigeration/Commercial Sales Manager

Meeting the FCC Backup Power Mandate From Site Audit to Total Site Solutions. DC Power, Outside Plant & Services for Business-Critical Continuity

Fujitsu General New Zealand Ltd

RagingWire Enterprise Solutions

DECISION TIME? A REPAIR OR REPLACEMENT GUIDE FOR HVAC EQUIPMENT REPAIR OR REPLACEMENT GUIDE

Performance 17 Two-Stage Air Conditioner with Puron Refrigerant

7. COST AND EMISSION REDUCTION ANALYSIS OF HFC EMISSIONS FROM REFRIGERATION AND AIR-CONDITIONING IN THE UNITED STATES INTRODUCTION...

Blade Servers and Beyond: Adaptive Cooling for the Next Generation of IT Systems. A White Paper from the Experts in Business-Critical Continuity

The Development of Heat Pump Water Heaters Using CO 2 Refrigerant

Transcription:

Technical Note: Comparing R407C and R410A as Alternatives for R22 A Technical Note from the Experts in Business-Critical Continuity

Purpose The purpose of this document is to provide a brief overview of refrigerants R410A and R407C, describe their characteristics and compare their environmental impact, regulatory compliance and resulting system efficiency. Background Chlorodifluoromethane (R22 or HCFC22) has been used as a refrigerant within refrigeration, industrial cooling, air conditioning and heating applications for many years. The low ozone depletion potential of R22 compared to CFC11 and CFC12 combined with its excellent refrigerant properties have helped facilitate the transition away from CFCs. However, even if HCFCs, such as R22, are less damaging to the ozone layer than CFCs, they still contain ozone-destroying chlorine. In addition, R22 is a greenhouse gas and the manufacture of R22 results in a byproduct (HFC23) that contributes significantly to global warming. Therefore R22 is being phased out and replaced with ozone-friendly refrigerants. As the manufacture of R22 is phased out over the coming years to end production of HCFCs, alternatives such as R407C and R410A will be manufactured. R407C and R410A R407C is a non-ozone depleting blend of three HFC refrigerants (R32, R125, R134A) and was designed to match as closely as possible R22 pressure and performance to allow a smooth transition from R22 to R407C. It exhibits performance characteristics similar to R22. R410A is a non-ozone depleting blend of two HFC refrigerants (R32, R125) and was designed to provide benefits in efficiency and system size by increasing system pressure and taking advantage of thermodynamic and transport properties. It exhibits higher pressures and refrigeration capacity than R22. The properties and performance of R407C and R410A are compared in Table 1. Under the terms of the Montreal Protocol, the U.S. agreed to a phase-out schedule as follows: January 1, 2010 Equipment manufacturers can no longer manufacture equipment that contains R22. Chemical manufacturers may still produce R22 to service existing equipment, but not for use in new equipment. January 1, 2020 Manufacturers will no longer be able to produce R22 to service existing equipment. 1

R407C and R410A Comparative Data Properties/Performance R407C R410A Comments Ozone depletion potential, ODP, (CFC11=1.0) Global warming potential, GWP, (CO2=1.0 [100 yr integrated time horizon]) Maximum allowable concentration in the workplace (ppm) Flammable No No Toxicity Very Low Very Low Relative energy efficiency -7 to -3 b -2 to +2 c ratio, EER (%) a Change in discharge -15 to -8 b -9 to -11 c temperature ( F) a Change in discharge pressure (psi) a +15 to +40 b +131 to +150 c Table 1. Properties and performance of R407C and R410A. 0 0 ODP value for R22 is 0.055. The lower the value, the better the environmental performance. 1600 1725 GWP value for R22 is 1600. The lower the value, the better the environmental performance. 1000 1000 a Compared with R22. b Values compared with HCFC-22 in unmodified split system heat pumps and an unmodified window air conditioner using the Department of Energy cooling test conditions A and B. c Values compared with HCFC-22 in split system heat pump with capacity-matched compressor using the DOE cooling test conditions A and B. Source: DuPont Fluorochemicals Advantages and Disadvantages of R407C and R410A R407C Advantages Less harmful influence on the environment than R22. Value of global warming potential of R407 is similar to that of R22 but ozone depletion potential is zero. Exhibits thermo-physical properties that are similar to R22, so when changing from R22 to R407C, minimal alterations in the refrigeration system are required. An R22 system and an R407C system use many of the exact same components. Disadvantages Multiple significant leaks (50 wt. %), and recharges, can in some cases cause the refrigerant composition to change, which could have a minor impact on energy efficiency and heat transfer conditions. 2

R410A Advantages Less harmful influence on the environment than R22. Value of global warming potential of R410A is higher than that of R22 but ozone depletion potential is zero. Characteristics of R410A permit using a smaller displacement compressor, less coil and less refrigerant while maintaining system efficiencies comparable to current R22 equipment. Disadvantages Operating pressures more than 50 percent higher than R22, which requires thicker walled tubing, high pressure compressors and use of components capable of withstanding these high pressures. An R22 system and an R410A system use none of the same components. A complete redesign of an R22 system is required to use R410A.The high operating pressures can also restrict the use of R410A to smaller systems, especially on water cooled systems. Conclusion Both R407C and R410A are less harmful to the environment than R22 and they offer equivalent performance and higher capacity alternatives to R22. They have the same designation (A1) in ASHRAE Standard 34 Designation and Safety Classification of Refrigerants. Because both refrigerants are widely available, their resulting system performance is very similar and they have a common classification within the Montreal Protocol, they are equal alternatives for projects where compressorized cooling is included. Currently R410A is being used extensively for most new, small residential air cooled systems. 3

Emerson Network Power 1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800.877.9222 (U.S. & Canada Only) 614.888.0246 (Outside U.S.) Fax: 614.841.6022 EmersonNetworkPower.com Liebert.com While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions. Specifications subject to change without notice. 2008 Liebert Corporation. All rights reserved throughout the world. Trademarks or registered trademarks are property of their respective owners. Liebert and the Liebert logo are registered trademarks of the Liebert Corporation. Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2009 Emerson Electric Co. TN-00007 Emerson Network Power. The global leader in enabling Business-Critical Continuity. AC Power Embedded Computing Outside Plant Connectivity Embedded Power Power Switching & Controls DC Power Monitoring Precision Cooling EmersonNetworkPower. com Racks & Integrated Cabinets Services Surge Protection