Reliability in Surge Protection. Security Systems. www.citel.fr



Similar documents
Surge Protection for Photovoltaic Systems

SURGE PROTECTIVE DEVICES

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

c o m m u n i c a t i o n n e t w o r k s

Características. Starligh SA 9 de julio 1595 Córdoba Argentina /

Quick Connect. quick - simple - efficient.

Rack mounted telephone- and leased line modem for industrial applications

Indoor / Outdoor Antenna

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

PRO-serie cctv cameras

Intersection Preassembled 19-inch Rack

CATALOGUE SURGE PROTECTION LOW VOLTAGE

DIRECT STRIKE PROTECTION. CAT Terminal, Gold, Model III

2G-1.1.0, 200M-2.0.3, 200M-1.0.1

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Application/Connection Examples

System Wiring Design Guide

System Wiring Design Guide

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Research RF Sputtering Packages

Office of Integrated Security Systems Longwood University Camera System Standards

Telephone- and leased line modem for industrial applications TD-36

MTL Surge Technologies. Product Overview

38 Series - Relay interface modules A

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Fiber s Role in the Video Security & Surveillance Network. Curt Carlson Product Manager Transition Networks

GSM Voice Auto Dialer & SMS Sender JC-999

38 Series - Relay interface modules A

Safety technique. Emergency stop module BO 5988 safemaster

Ethernet over Copper Transmission Extenders. Ethernet Transmission over Coaxial or UTP Cable. Fiber Optic and Ethernet Network Solutions

Business Customer Demarcation Information

Application Note: Modbus/RS485 Wiring for Conext Core XC Series Inverters

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

Provides one channel for Ethernet over existing

Terminal and Dimension

TPM Product Type 107-D162-NNT 48-channel digital input and 16-channel digital output module with pluggable terminal

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: LA-1011

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Ethernet over Copper Transmission Extenders

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

WD-AMX Water Detection Controllers

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Easily connect your switchboards to facility management solutions

Model 1756 Test Lead Kit

AXIS T81B22 DC 30W Midspan

Trip circuit supervision relay. Type RXTCS

CalMod Design-Build Electrification Services

EQUIPMENT SPECIFICATIONS

T200, PTP/IEEE 1588 Grandmaster Clock and

EDI Distributor Control Interface Wiring and Setup Instructions

LED - Indicator Panels

Terminal and Dimension

RY2 miniature industrial relays

T1 Backhaul Connectivity Solution All Products :: Application Note

Provides one channel for Ethernet over existing

FEMA ELECTRÓNICA. Serie ISC SIGNAL CONVERTERS WITH GALVANIC ISOLATION. MODEL ISC-IAC for AC Currents ISC-IDC for DC Currents USER S MANUAL

conventional system operation

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

ADACSNET USB Control Module

Installation manual. Generator Paralleling Controller GPC multi-line C

Remote Sources. Facility. Router

Video Camera Installation Guide

Thermistor motor protection

Frequently Asked Questions

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

LOXONE 12 Channel Amplifier

DS 600. A contact free flux gate based current measurement sensor 600A rms

Panel Meters and Controllers Modular Panel Meter Type EDM 35

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Quality passive and active video baluns for long distance transmission of CCTV images High quality transmission products ZEN-BAL-V1

Power over Ethernet technology for industrial Ethernet networks

38. ACCESS CONTROL AND ELECTRONIC SECURITY SYSTEM

Model CFA-24 Transparent Cable Farm Automation Switch

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

OPT SERIAL TO FIBER OPTIC CONVERTER

KONSTANTER SPL / SPL Programmable Electronic Load

ABB Inc. April 19, 2011 Slide 1

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

DLP-PU/E Instruction Manual

1. Franklin Rod Performance 2. LEC/DAS Performance

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

R.C.C.B. s two-pole LEXIC

FIREDEX Conventional Fire Panels

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

A project to optimise quality and energy efficiency must include metering

USER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.

POS UNITS. Installation and user guide. Count, video recording and POS control unit ENGLISH

RELAYS Solar Energy Systems

Transcription:

Reliability in Surge Protection Security Systems www.citel.fr

All devices used in security system are based on integrated circuit that is highly susceptible and vulnerable to lightning and switching surges. If these systems are damaged by a transient, then the entire protection strategy could be compromised : surge protection is highly recommanded. The cost of fully surge protecting a security system is limited and provides peace of mind that your system will be operational when you need it most. CCTV CAMERAS SECURITY ROOM FIRE ALARM ACCESS CONTROL - RAK BNC - RAK16-E-C6 - RAK16-POE-A - DS240-230/G - DS440-230/G - MSB10-400 - DS220-12DC - DS220-24DC - DS230-48DC - MSP - UTPB - DIN BNC - DIN-E-C6 - CXC - MJ8 DLA-06D3 DLA-12D3 DLA-24D3 DLA-48D3

Surge protectors for CCTV cameras Combined CCTV surge protectors The MSP-VM-2P series is designed to protect Pan Tilt Zoom security cameras connected to a CCTV network from transient overvoltages. It is a triple protection for video signal, 24 V or 230 Vac power supply and RS485 data signal lines. Technical data MSP-VM24-2P MSP-VM230-2P Max. video line voltage 6 Vdc 6 Vdc Max. data line voltage 8 Vdc 8 Vdc Max. power line voltage 30 Vac/Vdc 255 Vac 8/20 µs impulse - 10 times 5kA/10kA (video) 5kA/10kA (video) BNC surge protectors This surge protector is designed to protect a single BNC coaxial line and can be used in multiline configuration in the RAK 16- BNC panel Technical data Max. line voltage 8/20µs impulse - 10 times CXC06-B/FM 6 Vdc 10 ka BNC Female/Male BNC surge protectors Technical data Nominal voltage line (DC) DIN-BNC 6 Vdc 300 A BNC Female/Female Video Balun surge protectors UTPB-1 series is a single channel video balun with surge protection. They are used to interface DVR s, CCTV cameras and multiplexers. Technical data UTPB-1 UTPB-1J Transmission signal 1 channel 1 channel Transmission distance up to 600 m up to 600 m Isolation voltage 4 kv 4 kv BNC-male 2 wires screw terminal BNC-male jumper 2 wires screw terminal

CAT6 surge protectors Technical data Max. line voltage DIN-E-C6 7.5 Vdc 400 A RJ45/RJ45 CAT5 and POE surge protectors Technical data MJ8-POE-A MJ8-POE-B MJ8-CAT5E Max. line voltage 60 Vdc 7.5 Vdc (1,2,3,6) 8 Vdc 60 Vdc (4,5,7,8) 2 ka 2 ka 2kA (line/ground @ 8/20µs) Shielded RJ45 Shielded RJ45 Shielded RJ45 Surge protectors for Control Rooms 19 rack surge protectors Technical data RAK16-BNC RAK16-E-C6 RAK16-POE-A Number of ports 16 16 16 Maximum line voltage 7.5 Vdc 7.5 Vdc 60 Vdc Nominal discharge current 300 A 400 A 300 A BNC RJ45 RJ45

Surge protectors for Access Control and Fire Alarm System AC surge protectors Technical data DS240-230/G DS440-230/G MSB10-400 AC network 230 V 230 V 230 V Configuration Single-phase 3-phase +N Single-phase Max. operating voltage 255 V 255 V 255 V Nominal discharge current 20 ka 20 ka 3 ka Maximum discharge current 40 ka 40 ka 10 ka Wiring Screw terminal Screw terminal Wires Mounting DIN rail DIN rail Wall/Flange Remote signalling Option Option No DC surge protectors Technical data DS220-12DC DS220-24DC DS230-48DC Nominal DC voltage 12 Vdc 24 VdC 48 Vdc Max. operating voltage 24 Vdc 38 VdC 65 Vdc Nominal discharge current 10 ka 10 ka 20 ka Maximum discharge current 20 ka 20 ka 30 ka Wiring Screw terminal Screw terminal Screw terminal Mounting DIN rail DIN rail DIN rail Remote signalling Option Option Option Dataline surge protectors Technical data DLA-06D3 DLA-12D3 DLA-24D3 DLA-48D3 Typical application RS422 RS232/RS485 4-20mA 48 V line Configuration 1pair+shield 1 pair+shield 1 pair+shield 1 pair+shield Nominal line voltage 6 V 12 V 24 V 48 V Max. line current 300 ma 300 ma 300 ma 300 ma Nominal discharge current 5 ka 5 ka 5 ka 5 ka Maximum discharge current 20 ka 20 ka 20 ka 20 ka Mounting DIN rail DIN rail DIN rail DIN rail

Reliability in Surge Protection BR121202A - Document could be modified without notice Head office CITEL-2CP 2, rue Troyon 92316 Sèvres CEDEX France Tél. : +33 1 41 23 50 23 Fax : +33 1 41 23 50 09 e-mail : contact@citel.fr Web : www.citel.fr Factory CITEL-2CP 3 impasse de la Blanchisserie BP 56 51052 Reims CEDEX France Tél. : +33 3 26 85 74 00 Fax : +33 3 26 85 74 30 Germany CITEL Electronics GmbH Alleestrasse 144, Tor 5 D-44793 Bochum Germany Tél. : +49 234 54 72 10 Fax : +49 234 54 72 199 e-mail : info@citel.de Web : www.citel.de USA CITEL Inc. 10108 USA Today Way Miramar, FL33025 USA Tel : (954) 430 6310 Fax : (954) 430 7785 e-mail : info@citel.us Web site : www.citel.us China Shanghai Citel Electronics Co,Ltd 499 Kang Yi Road Kang Qiao Industrial Zone 201315 Pudong, Shanghai P.R. CHINA Tél. : +86 21 58 12 25 25 Fax : +86 21 58 12 21 21 e-mail : shanghai@citel2cp.com Web : www.citel.cn Czech Republic CITEL ELECTRONICS Kundratka 17A 18000 Praha Czech Republic Tél. : +420 284840-395 Fax : + 420 284840-195 e-mail : citel@citel.cz Web : www.citel.cz Russia CITEL RUSSIA Bolchaya Pochtovaya Str 26B/1 RU-105082 Moscow Russia Tél. : +7 495 669 32 70 e-mail : info@citel.ru Web : www.citel.ru India CITEL INDIA A - 54 - South Extension, Part-II New Delhi - 110049 India Tél. : +91 11 2626 12 38 e-mail : indiacitel@gmail.com Web : www.citel.in