Speed sensor MiniCoder GEL 47 Flange assembly Technical information version 08.0 The MiniCoder family from Lenord + Bauer offers spacesaving solutions for the contactless measurement of rotational movements with direction sensing. The MiniCoders operate from 0 Hz on for the detection of very slow movements without pulse loss and up to 5 khz for the direct integration into high-speed motors and machines. The high interference immunity ensures reliable function even under adverse operating conditions. This MiniCoder GEL 47 with its standard flange and unique design solves almost all installation problems. Main features module range from m = 1.0 to m = 3.5 measuring frequency from 0 to 5 khz integrated frequency divider (option) simple flange-mounting without adjustment robust stainless steel casing straight or side cable outlet customized cable fittings very high protection class IP 68 wide temperature range -40 C to +10 C high electromagnetic compatibility Fields of application rail vehicles - traction control - wheel slip prevention - engine speed machine automation - measurement of speed and position in machines and motors Output signals signal forms: - single-track square-wave signals - two 90 -shifted square-wave signals for direction sensing - two signals with potential separation can be supplied with different voltages (option) All signals are also available in their inverted form. Internet: http://www.lenord.de E-Mail: info@lenord.de Lenord, Bauer & Co. GmbH Dohlenstrasse 3 46145 Oberhausen, Germany Telefon +49 (0)08 9963-0 Fax +49 (0)08 6769
Technical data Electrical data supply voltage U B = 10... 30 V DC, reverse polarity protected current consumption without load I B < 60 ma; I < 30 ma (with frequency divider) B output input signals and output frequency square-wave, 0... 5 khz duty.5 +/- 0.5 ² ) 0 r ise time ( m cable) > 10 V/µ s max. cable length electromagnetic compatibility isolation connection strength Mechanical data m odule * admissible working air gap and operating temperature range 100 m push-pull driver I m ax rail vehicles: EN 5011-3- industry applications: EN 50081-1 500 V = 0 ma and ; EN 5008-1 and 6 x 1 mm for signal pattern E, F, V, X 1 x 0.34 mm for signal pattern D, H screen connected at encoder (recommended), optionally insulated cable specification LK 1069 and LK 1070: are available on request m = 1.0; 1.5; 1.5; 1.75;.0;.5;.5; 3.0; 3.5 (other modules between 1.0 and 3.5 available on request) ) 0.7 mm ± 0.6 mm (recommended nominal value -40 C... +10 C 1 ) storage temperature range -40 C... +10 C protection class IP 68 vibration resistance (EN 60068 part -6) 00 m/s shock resistance (EN 60068 part -7) 000 m/s w idth of measuring toothed-wheel > 10 mm taking into account all tolerances form of material weight housing measuring toothed-wheel of measuring toothed-wheel with m cable without fittings involute teeth, slotted teeth, others on request ferromagnetic steel approx. 550 g stainless steel 1) Reduced air gap for modules 1.0 and 1.5 (air gap from 0.1... 0.8 mm). ) Tolerance dependent on the module of the toothed wheel. * Conversion from module (M) to diametric pitch (D.P.) D.P. = 5.4 M Frequency Divider This option can be used to reduce the signal output frequency by a given factor. This is useful for applications in which the detection of a pre-specified toothed wheel would otherwise produce an output frequency too high for the control electronics. Lenord +Bauer DS-47(08.0)
Pin layouts, Dimensions Pin layout 6 O F A. K? JE E A? K H 6 O F A. K? JE E A? K H / - " % - = @ / - " % - @ EL E@ A H / - " %. = @ / - " %. @ EL E@ A H > =? / - " %, A A? JHE? = O EI = JA @ M D EJA C HA O F E > =? / - " % 8 M D EJA / - " % 0 A A? JHE? = O EI = JA @ M D EJA / - " % : > =? M D EJA > H M > H M C HA O F E Dimension GEL 47 X F XXXX X (straight cable outlet) Dimension GEL 47X G XXXX X (side cable outlet) DS-47(08.0) Lenord +Bauer 3
Installation drawing, EMC and ESD instructions Installation drawing EMC instructions To ensure the certified electromagnetic compatibility (EMC), the following installation instructions must be observed: Connect the screen at the end of the cable using a large contact surface, if possible. Keep all unscreened cables as short as possible. Keep grounding connections as short as possible using large cross-sections (low-induction grounding strip, ribbon cable) If the event of differences in potential between machine ground and ground of electronic circuit, appropriate measures must be taken to prevent equalizing currents from flowing via the cable shield (e.g. by providing for large-section equipotential bonding conductors or by using cables with separate double shielding where the shields are connected only at one end). Lay signal and control cables away from power lines. The power supply must correspond to installation class 0 or 1 in according with B.3 of EN 61000-4-5 of 1995. ESD instructions (Components sensitive to electrostatic discharge) As with any other electronic device, the MiniCoder must be connected with the necessary precautions against the risk of electrostatic discharge. Connector pins and connecting wires must not be touched without suitable discharge protection devices. Observe the instructions of EN 100 015-1. 4 Lenord +Bauer DS-47(08.0)
Supply voltage concept GEL 47 V 1. The MiniCoder supply is electrically isolated from the supply of the evaluation electronics.. The MiniCoder supply is not electrically isolated from the evalution electronics. (The screen is applied to the sensor and to the electronics and is interrupted in the conduit box) DS-47(08.0) Lenord +Bauer 5
Examples of customized cable connections Encoder end standard cable, straight outlet standard cable, side outlet flexible conduit, straight outlet flexible conduit, side outlet rubber conduit, straight outlet flexible conduit, extended side outlet Cable end flexible conduit connection and cable end open rubber conduit and cable end open round connector with flexible conduit HTS connector with flexible conduit connector with shrink moulded sleeve round connector, 90 elbow with flexible conduit 6 Lenord +Bauer DS-47(08.0)
Type code Type code GEL 47 E F V X D H Signal pattern square-wave signal square-wave signals and their inverse signals two square-wave signals offset by 90 two square-wave signals offset by 90 and their inverse signals two square-wave signals 90, electrically isolated two square-wave signals 90 and their inverse signals, electrically isolated 1 4 6 8 A Frequency divider no frequency divider frequency divider frequency divider 4 frequency divider 6 frequency divider 8 frequency divider 10 F G S T Cable outlet straight, cable length m side outlet 90, cable length m with straight special fittings on request with side outlet special fittings on request M 1 0 0 M 1 5 M 1 5 0 M 1 7 5 M 0 0 M 5 M 5 0 M 3 0 0 M 3 5 0 Module M... module 1.00 module 1.5 module 1.50 module 1.75 module.00 module.5 module.50 module 3.00 module 3.50 0 1 only available with signal pattern E and F Temperature range -40... 10 C -40... 135 C (on request) 47 Ordering information If customized cable, conduit and connectors are required, please supply detailed specifications. DS-47(08.0) Lenord +Bauer 7
We have agencies in: Austria Belgium Canada Denmark Finland France Germany Great Britain Israel Italy Korea Malaysia Norway Portugal Sweden Switzerland Spain the Czech Republic the Netherlands the USA Turkey Lenord, Bauer & Co. GmbH Dohlenstrasse 3 46145 Oberhausen, Germany Phone: +49 08 9963-0 Fax: +49 08 6769 info@lenord.de www.lenord.de Subject to technical modifications and typographical errors. For the latest version please visit our web site : www.lenord.de. 8 Lenord +Bauer DS-47(08.0)