Amsterdam Data Centre AM2 Amsterdam IBX+ Data Centre Location Luttenbergweg 4 1101 EC Amsterdam The Netherlands About Equinix Inc Equinix, Inc. (Nasdaq: EQIX), connects more than 4,500 companies directly to their customers and partners inside the world s most networked data centers. Today, enterprise, cloud, networking, digital media and financial services companies leverage the Equinix interconnection platform in 32 strategic markets across the Americas, EMEA and Asia-Pacific. By connecting directly to their strategic partners and end users, customers are forming dynamic ecosystems inside Equinix. These interconnected ecosystems enable companies to optimize the performance of their content and applications and protect their vital digital assets. From Airports 12.3 mi (19.8 km) to Amsterdam Schiphol Airport (AMS) Location Orientation 0.06 mi (100m) to AM2 Amsterdam IBX+ Equinix Data Center. 8.2 mi (13.2 km) to Central Amsterdam ft 2 Breakdown Gross 96,2875 ft 2 Colocation Area 39,827 ft 2 Flex Space 18,836 ft 2 Satellite Platform Available The presence of AMS-IX, the largest Internet exchange in Europe, makes the AM2 data center an important hub for the networks serving the continent. This is one of many state of the art IBX centers in key metropolitan areas throughout Europe that offer a full range of premium colocation, interconnection and support services to a wide range of secure digital ecosystems built by networks, enterprise, content, cloud and IT services companies and financial institutions. Global SLA 99.999+% Power availability 99.99+% Temperature and Humidity availability 99.99+% Cross Connect availability Cooling Cooling Capacity Up to 2 kw/m² (6826 BTUH) Cooling Plant Cooling towers in N+1 Chillers in N+1. Cooling circuits in 2N CRAC-units in N+2. Security Physical Fireproof door, security officer in armored office window, secured mantrap, turnstiles to access data center and card reader for room entry Human 24x7 security guards Electronic 24x7 monitoring, access cards, intruder alarm, digital CCTV
Amsterdam Data Centre Technical specification Power Options Electrical Capacity 2.0 kva/m2 (4.5 kva per cabinet average) UPS Configuration AC supply: Static UPS System with up to 7x 275 kva in N+1 per string. 6 strings available - 7 minutes of autonomy on full load UPS Topology N+1 # of Utility Feeders 2 # of Power Transformers Six transformers at 2.5 MVA per feed Utility Voltage 10 kv Power Feeds 2x 20 MVA medium voltage 10 kv utility supply Power On-site 230 V AC or 400 V three phase AC Generators Distributed redundancy configuration - 2.8 MVA each. 1 generator per feed. 6 feeds available. 36 hours on-site fuel autonomy (120 m3), refuelable during use Standby Power 6x 2.1 MVA Standby Power Config. N+1 conform distributed redundancy model Lighting High frequency, minimal 300 Lux Building Building Type Concrete structure, including concrete roofing with bulletproof glass Floor Load Capacity 600 psf (30 kn/m²) Floor Type Anti-static 600 x 600 mm tiles with a 4.5 kn point load capacity, floor void of 800 mm. Conduction 10-7 ohm Slab/Height to Ceiling 4800 mm Fire Protection Fire Suppression High density fog, localized operation on a sprinkler per sprinkler basis Certifications ISO9001 ISO27001/NEN7510 compliant ISO14001ISO50001 OHSAS18001 PCI-DSS AoC SSAE16 / ISAE 3402 Interconnection Options Available System Whale bone and overhead ladder racking Cross Connects Single-Mode fiber, Multi-Mode fiber (62.5 and 50 micron), CAT6 Metro Connect Managed Ethernet/Metro Connect Lambda Extends choice and reach for carrier and network availability across metro areas offering Metro Connect Managed Ethernet National GigE and FastE, Metro Connect Managed Ethernet Metro GigE and FastE, Metro Connect Lambda Equinix Internet Exchange Central switch for public and private peering offering AMSIX (GigE, 10 GigE); NLIX GigE, 10GigE Equinix Carrier Ethernet Exchange Enables Ethernet Service Providers to interconnect to CENs and expand the reach of Ethernet services offering 1 Gig and 10 Gig Equinix Connect Automated network provisioning, multi-homing and billing offering Single-Homed GigE and FastE, Multi-Homed GigE and FastE Fire Detection Two stages of fire detection: Aspiration System VESDA - very early smoke detection system Point Detection Addressable analogue point detection system using optical detectors operating a double knock protocol
Boston Data Centre Internap Boston Data Centre Location 50 Innerbelt Road Somervillle MA 02143 About Internap Boston As one of the most power-dense facilities in the region, the Boston data center offers plenty of room to grow, utilizing a superior modular design to allow for enhanced flexibility and increased reliability. Stateof-the-art technology provides high-density power and high-efficiency cooling options, while advanced security features ensure that your data is protected 100% of the time. Located in Somerville near downtown Boston and accessible via mass transit with convenient access to highways, airports and hotels. Remote Management View and manage your colocation environment remotely. Reboot servers, check power utilization and environmentals and monitor bandwidth all via a single interface. Power Density Modular UPS units and high-efficiency cooling options enable power density of up to 12kW per rack. Resiliency N+1 redundancy of generators, UPS and cooling modules maximize the uptime of your environment. Carrier Diversity Modular UPS units and high-efficiency cooling options enable power density of up to 12kW per rack. Low-latency Connectivity Internap s multi-homed route optimized Performance IP provides links up to 10GB through multiple top-tier carriers. Energy-efficient Design Committed to providing a better working environment by consuming fewer fossil fuels, reducing greenhouse emissions, minimizing the impact on land. Speed to Market Grow as quickly as your business demands with modular power, space and connectivity elements. On-site Personnel Data center engineers and technical support staff are on-site 24/7, proactively monitoring facility vitals.
Boston Data Centre Technical specification Location and Site Information Total Space - 45,600 square feet Floor Type - Antistatic raised floor Loading Dock - Easy access for all size trucks Roof Rights - Yes Number of Entrance Vaults - 2 NPA / NXX - 617/591, 617/625, 617/627, 617/628, 617/629, 617/666, 617/776 Site Structure DC Build Year / Year Started - Built in 2009; latest additions in 2013 Number of Floors - Two w/ mezzanine Structure Type - Structural steel, reinforced concrete Exterior Type - Masonry Seismic Rating - Zone 2 A Ceiling Clearance - 14 feet In Flood Plain - No Fire Protection Wet, Dry or Pre-action - Dry and Pre-action Number of Zones - 36 Smoke/Heat Detection - Yes Sub-Floor Detection - No Remotely Monitored - Yes Environmental Control Cooling Capacity - 1700 ton Cooling Type - RTU / chilled water Redundancy - N+1 Heating Type - N/A Humidification - Ultrasonic Security CCTV - Yes - 26 cameras CCTV Recorded - Up to 90 days Intrusion Detection - Yes On-site Guards - 24/7 Card Access - HID proximity card readers/ biometrics Access Control - Biometric and card reader Power Electric Utility - nstar Power Feeds - 2 diverse feeds; 3 MW Redundant Power Feed - Yes, direct buried to the power plant Generator - (3) Baldor Generator Size(s) - 2 MW Generator Fuel - Diesel UPS - GE UPS Size(s) - 5 Parallel 750 kva Battery Type - Lead Calcium (wet cell) & VRLA Battery Life at Full Load - 15 minutes Electrical Infrastructure Redundancy - N+1 Harmonic Filters - Yes Remotely Monitored - Yes Carrier-Neutral Meet-Me-Room Verizon - Verizon Business Lightower (Formerly Sidera/RCN/METRO Optical Networks) - Genesis Fiber Communications Lightower - Level 3 Communications Internap IP Network Carriers Cogent - CenturyLink Sprint - XO Communications Tiscali - Savvis
Synergy Park Synergy Park The total package for perfect data storage About Synergy Park With over 50,851 square-feet of raised fl oor, the Synergy Park data center, located in the Dallas, Texas metropolitan area, was built with the single focus of protecting your mission-critical data and applications. The data center offers complete offi ce facilities and total disaster recovery services. This data center also has the latest UPS power equipment, the most powerful, yet energy effi cient cooling system and documented security measures that help customers achieve and sustain compliance. Synergy Park even utilizes dual diverse utility power feeds for the ultimate in redundancy. Our 24x7 local engineers and service staff are experts at running data centers. We built this data center around you, the customer, to give you a peaceful state of mind. Performance that raises the bar We offer a 2(N+1) 9,900 kva UPS system with multiple redundant power distribution paths, plus 3 times the static pressure of traditional cooling, to give you performance that raises the bar. Your satisfaction is guaranteed We have enough confi dence in everything we do to offer our customers a 100% satisfaction guarantee, as well as a 100% SLA for power, bandwidth and network services availability. Superior network and cooling Top network providers have diverse underground entry points into the data center. The facility s fully redundant cooling system has 2,700 tons of capacity and 700+ Watt/SF high density pods availability. Local teams deliver expert service. Our dedicated, local staff of trained engineers help maintain uptime through remote hands capabilities, ticket tracking, event notification and more. Centered Around You. A large customer of ours in Dallas said it best, We ve never seen a service DNA so ingrained into a culture before. As the leading colocation service provider in North America, the real value ViaWest provides to customers is peace of mind. We provide a stable foundation for our customers to run their mission critical applications that drive their businesses. And we do this with a focus on the customer experience from pre-sales to implementation to on-going life cycle support. TOM MYERS, RVP OF SALES AND GM OF TEXAS
Synergy Park Technical specification Space Options 50,851 square feet raised floor Private suites and cages Unit level available in full and half cabinet increments Customer office space Security 24x7 access via dual factor authentication Monitored security cameras and intercom system Power delivery, generator and diesel fuel infrastructure maintained and under 24x7 surveillance ViaWest has a dual-standard SSAE 16 and ISAE 3402 Service Organization Control (SOC) 1 Type II, SOC 2 Type II, and SOC 3 reports covering each of ViaWest s data centers to include Operations, physical and environmental security controls. ViaWest also has facility-specific PCI DSS and HIPAA Reports of Compliance for physical security, information security policies and managed firewall services. ViaWest enables businesses to become compliant in the Financial, Healthcare and Federal industries that require regulatory authority of PCI DSS, HIPAA, FISMA and NIST 800-53 Standards. Additionally, ViaWest annually registers its adherence to the US-EU Safe Harbor Privacy framework. Fire Detection & Suppression Certified data center smoke detection system VESDA incipient smoke detection Dual-Interlock pre-action dry pipe sprinkler system Clean agent fire extinguishers placed throughout the facility Local Data Centre Support Teams Certified data center smoke detection system On location - staffed 24x7x365 with Data Center Technicians (first responders & remote hands) All Physical entry, environmental, power & networks monitored real-time Power A and B source power circuit delivery capabilities Dual redundant medium voltage power utility deliveries with onsite 25 kv substation 13 megawatt diesel power generation capacity Automatic power switching 9,900 kva UPS installed capacity Redundant battery strings Multiple redundant power distribution paths Branch Circuit Monitoring System HVAC & Enviromental Design 2,700 tons of cooling capacity Anti-static raised flooring with designated cable runs and cold air delivery Hot aisle/cold aisle configuration Fully cabled for typical customer applications Network Multiple redundant fiber optic telecommunication networks delivered via Telcordia/Bellcore standards with diverse conduit and entrance facilities Telecommunications services available with capacity ranging from T1 to multiple OC192 Ethernet services available from 5 Mbps to multiple 10 Gbps Viawest s Technical Assistance Centre (V-TAC) Single Point of Contact for all technical support needs for all remote calls Available 24x7x365 by experienced TAC support engineers
Gutleutstrasse, Frankfurt Data Centre Gutleutstrasse, Frankfurt Highly connected, premium data centre space Location TelecityGroup Gutleutstrasse 310 60327 Frankfurt/M. Germany About Internap Boston As one of the most power-dense facilities in the region, the Boston data center offers plenty of room to grow, utilizing a superior modular design to allow for enhanced flexibility and increased reliability. State-of-theart technology provides high-density power and high-efficiencycooling options, while advanced security features ensure that your data is protected 100% of the time. General Gross Data Floor Area (m2) - 10000 Building type - Purpose-built datacentre Building tenure - Long term lease Number of data floors - 4 Number of IT zones - 12 High density capacity - Yes Minimum floor load capacity (kg/m2) - 2000 Raised access floor height (mm) - 680 Raised floor to ceiling height (metres) - 4.5 11 Goods lift maximum load (tons) - 1.0 Separate delivery bay - Yes Build/unpacking room - Yes Security Type of security system - Proximity Access Card Staffed - 24/7/365 Fire Detection & Suppression High sensitivity smoke detection system - Yes Type of fire suppression system - Inergen gas Smoke detection double knock - Yes Air Conditioning & Cooling Type of cooling system - Chilled water Number of chillers (if applicable) - 6 Maximum cooling capacity (MW) - 10.3 Cooling redundancy each independent system - N+1 CCUs or in-row cooling - CCU Power Number of independent supplies into site - 4 Total incoming feed capacity (MVA) - 14.4 Diverse power route - Yes Generator fuel at full load (hours) - 24 UPS type - Hybrid Rotary UPS autonomy (minutes) at full system load - 10 Maximum UPS capacity (kva) - 12500 UPS redundancy - N+1, 2N optional Generator redundancy - N+1, 2N optional Maximum Generator capacity (MVA) - 19.2t
Boston Data Centre
Hong Kong Data Centre HK2 Hong Kong IBX+ Data Centre Location 1/F Kerry Warehouse 3 Shing Yiu Street Kwai Chung Hong Kong About Equinix Inc Equinix, Inc. (Nasdaq: EQIX), connects more than 4,500 companies directly to their customers and partners inside the world s most networked data centers. Today, enterprise, cloud, networking, digital media and financial services companies leverage the Equinix interconnection platform in 32 strategic markets acrossthe Americas, EMEA and Asia-Pacific. By connecting directly to their strategic partners and end users, customers are forming dynamic ecosystems inside Equinix. These interconnected ecosystems enable companies to optimize the performance of their content and applications and protect their vital digital assets. From Airports 16.3 miles (26 km) from Hong Kong International Airport Location Orientation 9.3 miles (15 km) from Central Business District ft 2 Breakdown Leased 159,207 ft 2 Colocation Area 53,260 ft 2 IBXflex Space Custom Request Satellite Platform Custom Request Equinix Hong Kong data center (HK2) occupies multiple floors of the Kerry Warehouse, strategically located in an industrial area in between the Hong Kong International Airport and the Central Business District. This is one of many state of the art IBX centers in key metropolitan areas throughout Asia-Pacific that offers a full range of premium colocation, interconnection and support services to a wide range of secure digital ecosystems built by networks, enterprise, content, cloud and IT services companies and financial institutions. Global SLA 99.999+% Power availability 99.99+% Temperature and Humidity availability 99.99+% Cross Connect availability Cooling Cooling Capacity 3.6 kva per cabinet Cooling Plant Water-Cooled Centrifugal Chillers (N+1); Computer Room Air Conditioners (N + 20%); Phase 1: 3 x 315 RT; Phase 2: 3 x 1,000 RT Security Physical Physical access control lists manage ingress and egress Human 24x7x365 security officers Electronic 24x7x365 CCTV recordings, Access Control
Hong Kong Data Centre Technical specification Power Options Electrical Capacity (Critical Customer Load) 3.6 kva per cabinet Electrical Capacity (Uninterruptible Power System) Phase 1: 4 x (2 x 500) kva (N+N) Phase 2: 3 x (2 x 400) kva (N+1); 4 x (2 x 400) kva (N+N) Utility Feeders Phase 1: 2 x 11 kv Phase 2: 3 x 11 kv Power Transformers Phase 1: 4 x 2 MVA + 2 x 1.6 MVA 11kV/380V Phase 2: 9 x 2 MVA 11kV/380V Standby Power Diesel Generators Phase 1: 4 x 2.25 MVA (N+N) Phase 2: 9 x 2.25 MVA (N+N) Building Certifications ISO / IEC 27001: 2005 Interconnection Options Available System Meet-me-room Cross Connects Cat5e/6, COAX and Fiber Metro Connect Extends choice and reach for carrier and network availability across metro areas offering Metro Connect to HK1 and Mega iadvantage Equinix Internet Exchange Central switch for public and private peering offering Gigabit Ethernet and 10Gigabit Ethernet Equinix Connect Automated network provisioning, multi-homing and billing offering Fast Ethernet and Gigabit Ethernet Construction Type Reinforced concrete structure Building Type 18-story / raised floor Floor Load 15 kn/m² Slab-to-ceiling Height 4.85 m Fire Protection Fire Detection Very Early Smoke Detection Apparatus (VESDA); smoke and heat detectors Fire Suppression FM200 for Fuel Tank Rooms Fire Rating Minimum 1 hour rating
NYC1 NYC1-60 Hudson Street, New York, NY Location 1 State Street 21st Floor New York NY 10004 About NYC1 NYC1 (60 Hudson St) is recognized as one of the most important colocation and interconnection facilities in the US. Telx, Interconnection and Data Center Company As the leading colocation and interconnection service provider in the premier carrier hotel in North America, Telx offers low-latency access to more than 400 carriers, financial exchanges, application providers, media and content providers, software-as-a-service providers and numerous enterprises with just a single connection. Telx occupies floors 5, 9, 11, and 23 with interconnectivity between all floors. Customers at this location can directly access the wide range of services provided by Telx customers located at other Telx New York and Northern New Jersey locations including: NYC2 (111 8th Ave), NYC3 (32 Ave of the Americas), NJR1 (300 Boulevard East), NJR2 (100 Delawanna Ave) and NJR3 (100 Delawanna Ave). This facility also provides access to the Telx Internet ExchangeSM and multiple peering exchanges. This facility is the connection center for international communication and offers physical connection points to the world s telecommunications networks and Internet backbones. Why NYC1 Access to over 400 carriers, ISP s and enterprise networks Access to over 60 financial networks via Financial ecosystems at NYC2 (111 8th Ave) Cost effective connectivity to NYC2 (111 8th Ave), NYC3 (32 Ave of the Americas), NJR1 (300 Boulevard East), and the Clifton Campus (NJR2 and NJR3 at 100 Delawanna Ave) via Telx s Metro ConnectSM Direct access to SFTI Network via NYC2 (111 8th Ave) connectivity About Telx Telx is a new kind of data center solution provider fueling infrastructure, interconnection and business progress. With an industry leading 100% uptime and 100% on-time service delivery SLAs, Telx helps companies build more agile businesses faster with reduced infrastructure complexity and broader reach to new markets. A privately held company headquartered in New York with west coast operations out of San Francisco, Telx serves a broad range of industries types from 20 data centers located across 13 US markets. Capacity. Capabilities. Connections.SM At NYC1 you will have direct access to connect with hundreds of leading providers and businesses within the Telx Global Ecosystem.
NYC1 Technical specification Facility Specs Building - 24 stories; 1,800,000 (sq.ft.) Telx Leased - 148,000 (sq.ft.) Flood Zone - Outside 100 year flood plain Seismic - Zone 2A Utility Power Capacity - 6750 (kw) UPS Power Capacity - 3075 (kw) UPS Redundancy - N-2N Power Density - 80-125 (W/sq.ft.) DC Power Capacity - 500 (kw) Generator Power Capacity - 10500 (kw) Generator Redundancy - N-N+1 Cooling Redundancy - N+1 Roof - Membrane and reinforced concrete decking Roof right available Floor Loading - 125 (lbs/sq.ft Fiber and Building Entry - Diverse conduit entry points Security - 24x365 manned security Card key and biometric access control Digital video monitoring and recording, SOC3 Compliant, HIPAA Compliant Parking - Parking available Connect with the Telx Global Ecosystem At NYC1 you can connect directly to many leading providers and businesses. Below is a sample of the companies available. Asian Telecom Network France Telecom Hewlett Packard Company Optimum Lightpath Sprint Communications - VX Time Warner Cable Verizon For more information To learn more about the NYC1 location and how it can help your business, please contact Telx at info@telx.com or visit: www.telx.com/data-center/new-york/