How To Use A Corona Mdi 110



Similar documents
CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

HYDRUS ULTRASONIC METER

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

How To Use A Flowmeter

Digital inductive conductivity transmitter

AMTRON E-30 Compact heat and cooling meter

T U R B I N E G A S M E T E R

Fluxi 2000/TZ Turbine Gas Meter

Heat meters Cooling meters

Flow switches Series AD/VH

DMS 680. Universal length measuring system gauge inspection for»iso 9000«requirements

COMBIMASS. Technical Data COMBIMASS eco-bio +

API Marine. BMS Presentation. Ballast Measurement Systems

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

EFC Frequency converters

SITRANS F flowmeters SITRANS FUS080. SITRANS FUS380/FUE380/SONOCAL /179. flow sensor pipe, 4 transducers/transducer cables and a transmitter

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

4 Posiflow Proportional Solenoid Valves

ETC -SV. Class 0 oil-free compressed air through catalysis

Assisted lift operated 2/2-way solenoid valves Type EV250B

Refrigeration Compressed Air Dryer Buran Ultrapulse

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

AVL FUEL MASS FLOW METER & FUEL TEMPERATURE CONTROL

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Type 3353 Angle Seat Valve

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

System 8. ü ( System 8

SITRANS F flowmeters SITRANS FUS080. Flowmeter FUE380 with approval. 4/202 Siemens FI Overview

Pressure Switch for gas and air

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

Micro Motion Model D and DL Coriolis Flow and Density Meters

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Bulk water meters. All that counts. EnergyMetering

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Typical Aluminum GFM Mass Flow Meter

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

LINEAR MOTION CONTROL

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

V5001S. Kombi-S Shutoff Valve. Product specification sheet

MULTICAL 21 DATA SHEET. Electronic ultrasonic cold and hot water meter

OPTIMASS 1400 Technical Datasheet

IFC 070 Technical Datasheet

2/2 and 3/2 Way Size 6 Seat Valves

FLOW SYSTEM flow measurement system in open channels and non-pressurized pipes

Foam Systems Inductors & Proportioners

Heating with wood chips and pellets

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Self-operated Temperature Regulators Temperature Regulator Type 1u

Series DFMT Digital Paddlewheel Flowmeter

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

SITRANS F flowmeters SITRANS F M

MFP14, MFP14S and MFP14SS Automatic Pumps

Radial piston pumps type R and RG

How To Make A Fronius Cl Power Inverter

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

SONOMETER TM 1000 Ultrasonic compact heat meter

ELECTRIC CENTRAL HEATING FLOW BOILER

Operating Instructions for Plastic Flow Meter. Model: KSK

How To Use A Multi-Line Calculator With A Power Supply And Power Supply (Kamstrup)

Vacuum drying oven for non-flammable solvents

Hose and Tube Fittings Series 1-3

VdS en. VdS Guidelines for water extinguishing systems. Non-return valves. Requirements and test methods. VdS en : (01)

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

HERZ-Thermal Actuators

Plastic tube flowmeters Series PT/PS

Lava. Precision Solutions. Site Planning and Installation Guide

THERMAL ENERGY METER MC 108/ET

Installing a Probe. Typical Installation

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

Grant Agreement No SFERA. Solar Facilities for the European Research Area SEVENTH FRAMEWORK PROGRAMME. Capacities Specific Programme

Quick Connect. quick - simple - efficient.

Pressure transmitter For general industrial applications Model A-10

2.24. Pump Controller 704. Data Sheet

OPTIMASS 6000 Technical Datasheet

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

PS1800 Centrifugal Pumping Systems

Counter for Energy. We make energy measurable and secure your future.

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

ultrafilter VARIOBLO Heat Regenerated Adsorption Dryer

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

Turbine Flow Sensor Series VTR

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

A project to optimise quality and energy efficiency must include metering

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

3/2-way pneumatic cartridge solenoid valve

series Materials Body: 1/2, 3/4 and 1 : dezincification resistant alloy brass EN CW617N

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Material test chamber with mechanical convection

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Power consumption (kw)

Transcription:

CORONA MDI 110 APPLICATION Domestic water meter FEATURES 4 Modular multi-jet domestic meter with inductive scanning (without magnetic influence) 4 System capability, with standard applicable pulse output 1 l/pulse (inductive). CORONA MDI can be externed in any way - with IZAR RADIO COMPACT 868 I (radio module) or IZAR PULSE I (pulse transmitter) 4 Extremely low pressure loss and considerably extended measuring range 4 Records very small amounts of water consumption 4 Maximum long-term accuracy and absolutely corrosion-resistant 4 Measuring data better than specified by calibration regulations 4 Strainer insert in inlet connection for cleaning without damaging the seal 4 Capable of withstanding any load for a short time 4 Fine adjustment by regulating plug

CORONA MDI 110Meter for horizontal pipes CBR-EnergySolution ApS GENERAL Meter for horizontal pipes Medium temperature range C 0... 30 Temperature safety C 0... 50 Ambient operating temperature C 0... 55 Ambient storage temperature C 0... 55 Nominal pressure PN bar 16 Display range 0.05 l... 99,999 m³ Pulse value l/pulse 1 Protection class IP 65 TECHNICAL DATA Overload flow rate Q 4 m³/h 3.125 5 Transition flow rate Q 2 l/h 50 80 Minimum flow rate Q 1 l/h 31.25 50 Starting flow rate l/h 9 10 Pressure loss at Q 3 bar 0.38 0.53 Flow rate at 1 bar pressure loss m³/h 4.1 5.55 APPROVAL MID TH 8584 TH 8584 Dynamic range horizontal installation (Q 3/Q 1) R 50 / 80 50 / 80 28.10.2010 2

CORONA MDI 110Meter for horizontal pipes CBR-EnergySolution ApS DIMENSIONS Overall length (DIN ISO 4064) L mm 165 190 Overall length with coupling L2 mm 245 288 Connection thread on meter (ISO 228/1) Inch G¾B G1B Connection thread of coupling (DIN 2999) Inch R½ R¾ Height H mm 33 37 Height H1 mm 73 73 Diameter Ø B mm 95 95 Weight without coupling kg 1.11 1.16 Weight with coupling kg 1.31 1.46 PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 28.10.2010 3

CORONA MDI 110Meter for rising pipes GENERAL Meter for rising pipes Medium temperature range C 0... 30 Temperature safety C 0... 50 Ambient operating temperature C 0... 55 Ambient storage temperature C 0... 55 Nominal pressure PN bar 16 Display range 0.05 l... 99,999 m³ Pulse value l/pulse 1 Protection class IP 68 TECHNICAL DATA Overload flow rate Q 4 m³/h 5 Transition flow rate Q 2 l/h 80 Minimum flow rate Q 1 l/h 50 Starting flow rate l/h 12 Pressure loss at Q 3 bar 0.45 Flow rate at 1 bar pressure loss m³/h 5.77 APPROVAL MID TH 8584 Dynamic range vertical installation (Q 3/Q 1) R 50 / 80 28.10.2010 4

CORONA MDI 110Meter for rising pipes DIMENSIONS Overall length (DIN ISO 4064) L mm 105 Overall length with coupling L2 mm 203 Connection thread on meter (ISO 228/1) Inch G1B Connection thread of coupling (DIN 2999) Inch R¾ Height H mm 18 Height H1 mm 108 Diameter Ø B mm 95 Width A mm 82 Weight without coupling kg 1.54 Weight with coupling kg 1.86 PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 28.10.2010 5