UNIVERSAL TRAFFIC CONTROLLER



Similar documents
Chameleon MOVA INTELLIGENT COMMUNICATION OUTSTATION

connecdim Gateway G1 Ethernet TCP/IP to DALI

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Remote Monitoring and REC 501 Control Unit Product Guide

Foxboro Evo Process Automation System

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

INTEGRAL REMOTE MANAGEMENT SOLUTION cirwatt b series

High rate and Switched WiFi. WiFi QoS, Security 2G. WiFi a/b/g. PAN LAN Cellular MAN

FACILITY MONITORING SYSTEM DESIGN RECOMMENDATIONS

Be ready for emergencies

ABB RTU560A Series CMU & Modules

- Monitoring Array: a seismic or infrasound array, including from 1(4) to 20 Remote Elements (RE) and one Central Recording Facility (CRF).

S-series SQ Controller

Integrated Building Management and Security System. Building Automation & Security.

CompTIA Network+ (Exam N10-005)

Phase Modular Finally the benefits of Modular ups are for all

FLEET MANAGEMENT & CAR SECURITY SYSTEM GPRS/GPS

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

F5 BIG-IP V9 Local Traffic Management EE Demo Version. ITCertKeys.com

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

IT Networking and Security

CONSTANT CURRENT REGULATOR INDUPERM TYPE CCR 951. Standarddescription of CONSTANT CURRENT REGULATOR TYPE CCR 951.

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

PLCs and SCADA Systems

High Power Programmable DC Power Supplies PVS Series

Local PlantVisor. PlantWatch. Remote PlantVisor

Power network telecommunication

Documentation. M-Bus 130-mbx

Analysis and Simulation of VoIP LAN vs. WAN WLAN vs. WWAN

CPU ARM926EJ-S, 200MHz. Fast Ethernet 10/100 Mbps port. 6 digital input 2 digital open-drain alarm output

Fleet management system as actuator for public transport priority

Transporting Legacy Switched Digital Circuits Using a Packet Network

Watchdog Monitor user guide

RIELLO ELETTRONICA. Master HP

Monitoring and diagnostics. Field data integration to control room solution guide

Advanced Transportation Management Systems

CMS CONTENT MANAGEMENT SYSTEM

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

OfficeServ Application Suite

Iknaia Asset and Personnel Tracking Management System for the Construction Industry

imc BUSDAQ autonomous intelligent synchronized Field bus data acquisition - from stationary to mobile imc productive testing

R-Win. Smart Wireless Communication Management System

Communication and connectivity the ideal solution for integrated system management and data integrity

A Smart Investment for Flexible, Modular and Scalable Blade Architecture Designed for High-Performance Computing.

Chapter 9A. Network Definition. The Uses of a Network. Network Basics

Semaphore T BOX Applications in Data Center Facilities

Expandable serial alarm system

EoVDSL: A Cost-Effective Solution for Transmitting Ethernet Data Over Existing Copper Wiring for ITS and Traffi c Applications

Imtech RMS MonItoR your traffic control assets

AC750 Multi-Function Concurrent Dual-Band Wi-Fi Router

Process Control and Automation using Modbus Protocol

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Understand VLANs, Wired LANs, and Wireless LANs

Early Warning Fire Detection and Integrated Security Solution. System Overview

Chapter 7: Computer Networks, the Internet, and the World Wide Web. Invitation to Computer Science, C++ Version, Third Edition

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Safety Relay Units. G9SR family. Diagnosis with LEDs Selectable operating modes and times Increased extension possibilities. industrial.omron.

SITRAFFIC Canto communication system. A technological leap in center-to-field communication. Intelligent Traffic Systems

Using Cellular RTU Technology for Remote Monitoring and Control in Pipeline and Well Applications

OMC Solution IP Radios

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

S4000TH HART. HART Communication Manual

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

PowerGem Pro Uninterruptible Power Supply

Multizone Application >3. MSR300 System. No Software configurable? GuardPLC. Enet RECOMMENDED PRODUCTS. Time Delay MSR138

MONITORING. m 3 /s. m/s F. g/m 3. Software. Data Input. M2M Transfer. Processing. Reports Graphs, Excel Alarms. Measurement Sensors Dry contacts

Information. Siemens Enterprise Communications

Series Six Plus Programmable Controller

ZC-24DO CANopen I/O Module: 24 Digital Outputs

siemens.com/mobility Radar detectors of the Heimdall family High detection rate, easy installation

Installer guide. Release 2.2

Cisco Mobile Network Solutions for Commercial Transit Agencies

Product overview mm. 100 mm

Complete SCADA solution for Remote Monitoring and Control

Information. Communication for the open minded. Siemens Enterprise Communications

ABB central inverters PVS to 1000 kw

The evolution of data connectivity

Iknaia Asset and Personnel Tracking Management System for the Healthcare Industry

Frequently Asked Questions: Home Networking, Wireless Adapters, and Powerline Adapters for the BRAVIA Internet Video Link

Industrial Ethernet How to Keep Your Network Up and Running A Beginner s Guide to Redundancy Standards

BridgeWay Fixed Base Radio Telecom VoIP Gateway

Overview of the Cisco 2500 Series Access Server

DeltaV Remote Client. DeltaV Remote Client. Introduction. DeltaV Product Data Sheet. Remote engineering and operator consoles

SCADA and Monitoring for Solar Energy Plant

Parking Guidance System

561-MB100. Intruder Alarm Control Panel. Maximum security for all eventualities. Features

Rack mounted telephone- and leased line modem for industrial applications

Software-Defined Networking for Wi-Fi White Paper

Guest Room Controls & Monitoring System. Integrated Solution for Hotels Southern Countries.

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

KD-DP Integrated Network Management System. Easily Installed and Configured! NEC Corporation

TECNOALARM INTERNATIONAL LEADER OF SECURITY

IVS-200 Enter: intelligent "Enter" video analytics server. Model: IVS-200 Enter

PROFINET the Industrial Ethernet standard. Siemens AG Alle Rechte vorbehalten.

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Transcription:

Eventueel subtitel Eurocontroller EC-2 UNIVERSAL TRAFFIC CONTROLLER

EuroController EC-2 The Peek EuroController EC-2 is a state-of-the-art traffic controller, rooted in a long tradition of innovation and robustness. On the one hand it has an innovative design which integrates a flexible software architecture on a high power processor with extensive open connectivity. On the other hand it has a safety architecture that complies with European and local directives and electronics that is durable, robust and easy to maintain. The software architecture opens up many application areas. Not only is a wide range of traffic control algorithms supported, the EC-2 can also act as a universal road-side processor that can be applied to many different tasks. The extensive open communication options for the EC-2 make it an ideal node in a wider network. The EC-2 offers wired and wireless broadband connectivity in a flexible network topology, and can easily adapt to the rapidly changing world of modern telecommunication. Benefits The EC-2 has a number of specific benefits that make it very cost-effective in a large number of applications. The following non-exhaustive list gives some of the benefits of using an EC-2 traffic controller: The EC-2 offers a high level of integration and flexibility combined with a durable and robust design and is cost-effective; IP and TCP/IP connectivity. The EC-2 functions as a node in an open TCP/IP network and therefore can connect to all IP based applicationsthe EC-2 has been designed to work with 3 major adaptive traffic control systems: SCOOT, ImFlow, Utopia. The EC-2 offers supports the latest cooperative systems standards TheEC-2 has a long history of supporting public transport (conditional) priority. Such as VETAG, VECOM, shortdistance radio, and wireless lan. The EC-2 comes with tooling that supports configuration, simulation (VISSIM) and testing of programs.

Applications The EC-2 is primarily designed for traffic control at junctions and pedestrian crossings. However, the EC-2 can also be used as a universal roadside system. The EC-2 is freely programmable; it has extensive and diverse I/O modules and a wide range of communications facilities. If such complimentary applications are programmed on the EC-2, they can also be implemented on uncontrolled intersections by using the EC-200D. The EC-2 and the EC200D together form the ideal ITS buildingblocks for every modern city. EC-2 Features The following is a non-exhaustive list of EC-2 features: Web based user interface; accesible with laptop, smartphone or tablet or via a remote connection) Comprehensive fault log and event log facilities wiht remote maintenance facility; Four independent configurations can be stored in the controller; Configuraion update possible via various (wireless) network connections Free configuration of lamp switch circuits. Users can configure any function to any lamp switch; The EC-2 can use all different types of detection technology (e.g. loops, video, microwave) The Central Processing Unit (CPU) is the core of the EC-2 controller containing two autonomous processors, one for control and one for supervision; Integrated power unit including mains voltage monitoring, safety filters and separate main contactor for optimum safety; Variable data is stored in RAM with a memory backup for multiple months; ED316 loop detector board provides 16 channels on a single card, which can be software configured,eliminating the need for setting jumpers and switches; Integrated speed measurement using ED316; loop detection possible.

Technical specifications Double CPU system Supervisor processor (safety) Application processor (traffic control program) Interfaces 10 Mbit/s Ethernet 3x RS485/RS422 interfaces 1x RS232 modem interface 1x RS232 console interface Lamp Control Module Max. 4 signal groups per Lamp Control Module Lamp monitoring Transient protection Configuration Logic voltage 0..64 Signal groups 0..256 Detector circuits 0..256 Parallel outputs 0..128 Parallel outputs 1..8 Independent intersections 85VAC..264VAC 45Hz..65Hz Energy reserve >= 70ms Lamp voltage Optional lamp voltage 230V -20%.. +15% 50 HZ -4%.. +4% 42VAC/50Hz 40VAC/50Hz 110VAC/60Hz Operating temperature Approvals Software Outside the cabinet: -40.. +55 C Inside the cabinet: -40.. +55 C EN50556, EN12675, EN50293, NEN3384, TR2500 RWS requirements 1997 ASTRIN LED class II SRM2, CCOL, RWS-C, NCM LHOVRA, RiLSA Protocols IVERA 3.0 OCIT 1.1 UG405 ALERT+

Head office Imtech Traffic & Infra Basicweg 16 NL-3821 BR Amersfoort P.O. Box 2542 NL-3800 GB Amersfoort, The Netherlands Tel. +31 33 454 17 77 Fax +31 33 454 17 40 http://imtech.com/en/traffic-infra The total solution provider http://imtech.com/en/traffic-infra