FIREFIGHTER NEAR MISS



Similar documents
Emergency Response Guide

Emergency Response Guide

Emergency Response Guide

Portable Pipelines for First Responders

How To Stop A Gas Leak

Emergency Response Guide

Portable Pipelines for First Responders. Chris Christopoulos, Jr.

What Is a Typical CNG Vehicle?

Emergency Response. Prepared for Fire Service, Law Enforcement, Emergency Medical, and Professional Towing Personnel by American Honda Motor Co., Inc.

Fundamentals and practice of CNG safety -

CNG and LNG: What s Best for Your Fleet?

2012 Civic Natural Gas Retail & Fleet Markets. NGV Bridge Fleet Framework Summit March 26, 2013

CNG and Hydrogen Vehicle Fuel Tank Failure Incidents, Testing, and Preventive Measures

OREGON FIRE CODE Interpretations and Technical Advisories

mobile pipeline Bulk transportation and storage of energy gases

Distributed CNG and LNG as sources of natural gas in New England

Vehicle Maintenance Facilities Requirements for CNG and LNG Vehicles

Unit 8. Conversion Systems

Section 14. Forklift Safety Contents 14.1 Operator Safety

New England Pipeline Safety Seminar October 22, 2014

Red Oak Fire Rescue SECTION: New Car Technology

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

considering natural gas vehicles for your fleet? get the facts

Section III Hazardous Materials Management

2010 Honda Civic. GX Natural Gas Vehicle

5 Mechanisms and accessories

Autobody/Collision and Repair Technology/Technician CIP Task Grid

MOBILE FOOD VEHICLES (MFV)

2010 Residential Water Heater Replacement Check List

Quon Kwan. Safety Considerations Related to Commercial Vehicles Using Natural Gas. Natural Gas Vehicle Technology Forum San Diego, CA October 17, 2012

NOTIFICATION OF PERFORMANCE TESTING FOR GASOLINE DISPENSING FACILITIES (GDFs) NESHAP 40 CFR, Part 63, Subpart CCCCCC (Sections

Morrison Bros. Co. General Product Specifications

Flammable Liquids 29 CFR

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Pressure Vessels (Air Compressors) and LPG Tanks

Your Boiler Room: A Time Bomb?

Ron Eickelman President, Agility Fuel Systems

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

Preventing Overheated Boiler Incidents

Daryl Patrishkoff, PMP Chief Executive Officer Center for Professional Studies

FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST

FIREFIGHTER SAFETY. Stay safe during substation fires

Clean Abundant and Economical Natural Gas

Dry Chemical Systems TWIN AGENT CAPABILITY

Installation Guidance: CNG Refueling Stations

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

December Newsletter by Vincent Dunn Backdraft and flashover, what is the difference?

CNG & Hydrogen Tank Safety, R&D, and Testing

International Maritime Dangerous Goods (IMDG) Special Provision 961 and 962

The following definitions apply with regard to requirements specified in this document:

Service Bulletin SA-008. DATE: June 18, 2008 TO: All Service and Parts Managers SUBJECT: Flood Damaged Appliances

Frequently Asked Questions Generators

NFPA Fire Fighter II

Compressed Gas Cylinder Storage and Handling Guide

Advantages and Disadvantages of the Preferred Alternative Fuels

PROPANE AUTOGAS REPAIR AND MAINTENANCE FACILITY REQUIREMENTS

COMPRESSED GASES. 1.2 The contents of each cylinder and container must be clearly identified (by tag or stamp) on the cylinder.

Will Natural Gas Vehicles Be in Our Future?

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

Presented by: Rich Perry Marsh Risk Consulting

Heavy-Duty Lube and Fuel Truck Sales Tool

The following definitions apply with regard to requirements specified in this document:

natural gas Control control of of Natural Gas in Emergency Situations

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

Tank Farm and Bulk Storage Fire Incidents

LIQUEFIED PETROLEUM GASES

Notes. Material 1. Appropriate Flammable Liquids

3053 Electrical Safety Training Program Course Outline

STORE HAZARDOUS SUBSTANCES SAFELY. incompatibles gas cylinders

Requirements for Hydrogen Storage and Use

MOTOR VEHICLE MECHANIC REPAIR CATEGORIES

orlando OWNER S MANUAL

Fire and Life Safety Requirements for Special Events and Temporary Use of the Facilities at the Kitsap County Fairgrounds.

Multi-information Display (see MID )

Why SWN Choose Natural Gas Vehicles? Natural Gas Summit Austin, TX. October 23 rd 2014 Eddie Murray. Texas Railroad Commission

Compressed Natural Gas: Benefits for Vehicle Fleets

Airbags and Pretensioners. Emergency Response Guide

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Northeast Gas Association (NGA) 2012 Sales and Marketing Conference. Mike Manning Director of Marketing and Business Development AVSG LP Boston, MA

Compressed Gas Cylinder Program

Explosion in metal shipping container during firefighting

Natural Gas Emergencies

Installation Instructions for Alarm Module Kit A043F059

Based on the initial size-up and any information available, Command will formulate an action plan to deal with the situation.

International Forum on Pressure Vessels for Hydrogen and Natural Gas Vehicles

All You Ever Wanted to Know About Fire Extinguishers...

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

ENGINE COOLING SYSTEM

Watts Spacemaker. Sa f e t y Wa t e r He a t e r. Enclosures Stands Restraints

Emergency Plan. This emergency plan provides a format of data essential in an emergency situation.

SL280UHV SERIES GAS FURNACE WARNING

Your safety and the safety of others are very important.

BROADCAST MESSAGE FROM THE SACRAMENTO FIRE MARSHALL

Firefighter Review. Instructor Guide

ANTI-THEFT SYSTEM Volvo 850 DESCRIPTION & OPERATION BASIC ALARM ACCESSORIES & EQUIPMENT Volvo Anti-Theft Systems

Transcription:

FIREFIGHTER NEAR MISS Auto Fire with Compressed Natural Gas (CNG) Fuel Tank Explosion Prepared By Operations Division Final Version May 9, 2007

Incident #26564, March 26, 2007 Dispatch 0230 hours for car fire (Engine 10) E10 arrived and requested FIB for multiple vehicles with possible structural exposures (freeway columns and overpasses) 12 vehicles damaged or destroyed Firefighter near miss when CNG vehicle exploded as E10 crew approached with a handline (approximately 50-75 away) Determined to be arson 2

Fire Garage 3

Access Gate 4

E10 parked outside the gate here Debris from the explosion was thrown up to 100 in all directions including on the over- 5 passes above the incident.

Roof debris + + + ++ Bumper frame Trunk lid Backhoe Roof debris Fuel tank (original location) 6

Honda CNG Vehicle 7

Rear of vehicle 8

9

Roof is blown completely off vehicle and doors blown open 10

11

12

13

14

Metal mounting straps Seattle Fire for Department CNG tank 15

Trunk lid 16

Tank initially landed here, about 100 away then was moved down the hill for extinguishment. 17

Evidence indicates it may have ricocheted off the underside of a freeway overpass (next picture). 18

90 19

Rear bumper frame 90 + away 20

Bumper shrapnel (note burn marks on ground) 21

Roof section about 75 away 22

This may be your only warning of a CNG fueled vehicle. Typically located on the trunk lid or bumper. 23

Composite tank is carbon-fiber / fiberglass wrapped for strength similar to our SCBA tanks. 24

25

26

27

28

August 07, 2003 Airport Taxis, Shuttles Convert to Natural Gas New contract requires fleet conversions to improve air quality The Port of Seattle Commission today authorized the renewal of contracts with two major providers of ground transportation at Seattle-Tacoma International Airport. The contracts, with the Seattle Tacoma International Taxi Association (STITA) and Shuttle Express, will require the two organizations to make major investments to convert their fleets to clean-burning natural gas. Under its new contract, STITA will be required to convert its entire 160-cab fleet to natural gas in the next three years. By converting more quickly, STITA will earn the right to extend the contract from five to seven years. 29

Historical Information Several NHTSA (National Highway Traffic Safety Administration) investigations Example: January 27, 2003; Ford Crown Victoria on fire with flame impingement on CNG tank. The tank failed catastrophically prior to Pressure Relief Device (PRD) functioning. Vehicle recall with dealers installing additional insulation behind back seat. Number of vehicles still needing repair??? 30

Code of Federal Regulations CFR 49, Part 571 Standard 304 Compressed Natural Gas Fuel Container Integrity Flame Test Standard: Flame impingement generating 1550-1650 F. at the surface for the length of the cylinder for 20 minutes or until fuel is completely vented through PRV. 31

CNG Properties Compressed to 3,600 psi in fuel cylinder CNG rated at 117 octane fuel BTU per # = 22,800 (gasoline = 18,900) Not a liquid when compressed (it becomes a very close dense gas) Not the same as Liquified Natural Gas LNG (cryogenic: -260 to become liquified) Lighter than air when released (.6 air) 32

CNG Properties LEL / UEL = 4 16% (gasoline = 1.3 7.6) 1 cubic foot of CNG = 245 cu.ft. of natural gas at sea level (uncompressed) 1 cubic foot of CNG weighs 13# 5.66# = 1 Gasoline Gallon Equivalent (GGE) Honda Civic tank = 8 GGE Note: 1 gallon of gasoline properly vaporized has the explosive equivalency of 83 pounds of dynamite (CDC). 33

Cylinder Properties Four Cylinder Types: Type 1: all metal (steel or aluminum) Type 2: hoop wrapped steel or aluminum Type 3: fully wrapped steel or aluminum Type 4: all-composite (non-metallic)* *Early model Honda Civic uses Type 4; later models use Type 3 34

Honda Civic Tank Design 35

Honda Civic Tank Design Note: The pressure relief device (PRD) activates similar to a fusible link it fails versus resealing like a spring-assisted pressure reducing valve (PRV). The gas is vented out the vent tube until the tank is empty. Discharge time depends on fuel level. 36

Ongoing Investigation The tank was wrapped and secured at the FD Commissary for subsequent investigation by engineers from the various component manufacturers. 37

Ongoing Investigation Stakeholders have demonstrated a serious commitment to determining the cause and developing corrective recommendations Honda Motor Company sent four engineers from Japan and the U.S. The tank manufacturer sent an engineer from their Nebraska facility The valve manufacturer sent an engineer from their Ontario, Canada facility 38

Ongoing Investigation After an initial site investigation, the tank was shipped to Honda Motor Company for scientific analysis. Results are pending. 39

Ongoing Investigation Additional inquires have been received from: U.S. Department of Transportation National Highway Traffic Safety Administration State of Washington Department of Transportation A Firefighter Near Miss has been posted on-line 40

Lessons Learned / Best Practices Approach from 45 angle to vehicle ends Be aware of CNG vehicles Cabs, city vehicles, shuttles Look for CNG placards Watch for other hazards, i.e. bumper struts; hood and tailgate struts; airbags; burning fuel runoff; hazardous vehicle contents; exploding tires; other traffic Consider cooling streams from a distance 41

Best Practices Honda Civic The Best Way to Stop CNG Flow and Turn Off the Engine: KEYS Turn off the ignition switch, and remove the key. Turning off the ignition switch automatically shuts off the flow of CNG from the fuel tank. It also turns off power to the airbags and the seat belt tensioners within 3 minutes. 42

Best Practices Honda Civic The Second-Best Way to Stop CNG Flow and Turn Off the Engine: ELECTRICAL Remove the main fuse, and disconnect the battery negative cable. This method should be used if the ignition switch is in the ON (II) position, you cannot reach the key or the CNG manual shutoff valve, but you can reach under the hood. 43

Best Practices Honda Civic The Second-Best Way, continued: Removing the main fuse shuts off the flow of CNG from the fuel tank and turns off the engine. Disconnecting the battery negative cable cuts power to the airbags and the seat belt tensioners within 3 minutes. It also prevents the engine from being restarted. 44

Best Practices Honda Civic 45

Best Practices Honda Civic Least-Desirable Way for Stopping CNG Flow and Turning Off the Engine: GAS Turn off the CNG manual shutoff valve. This method does not disable the airbags or the seat belt tensioners. It should be used only if the engine is running, you cannot reach the key, and you cannot reach under the hood. 46

Civic CNG Shutoff Valve CNG Manual Shutoff Valve The Civic GX has a CNG manual shutoff valve to stop the flow of CNG from the fuel tank. The red handle of the valve is on the bottom of the car, near The left rear tire and the splash guard. 47

48

49

50

51

52

SAFETY SUMMARY Determine vehicle type during size-up Use 45 approach angle Watch for additional hazards Consider cooling streams from a distance If CNG vehicle, remember best practices: #1 KEYS #2 ELECTRICAL #3 GAS 53