MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera



Similar documents
MIC-WKT and MIC-WKT-IR

VG4 Fiber Optic Media Converter

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

SP-1700 OWNERS MANUAL

aseries A13B Mini Bullet Camera User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

D/N VARI-FOCAL IR CAMERA

AXIS T81B22 DC 30W Midspan

ATTENTION RISQUE D ÉLECTROCUTION! NE PAS OUVRIR!

KZ0224UW INSTALLATION MANUAL SURGE PROTECTED CCTV POWER SUPPLY 24V AC, 5 AMP KZMI /12/01

Fiber Optic Ethernet Media Converter Kit

BODi rs BD004 Series Bandwidth-on-Demand Internet with Reliability and Survivability. Quick Start Guide NOTES

Model 1756 Test Lead Kit

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Daily use. Never use alcohol or other solvents to clean any part of the loudspeakers!

When you switch off your system, or mute the sound, the red indicator light appears immediately, indicating that the subwoofer is not in use.

esata External Storage

INSTRUCTION MANUAL MODEL PCD-88

BroadBand PowerShield. User Manual

Doorbell Intercom Security System

FlexiDome Wall and Pipe Mounts VDA-WMT/PMT-Dome. Installation manual

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

UniStream CPU-for-Panel

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

The Bouncer Bluetooth Stereo Speaker

DAB+ / FM Tuner Model: TU-201

3M Wrist Strap and Footwear Tester 740. User s Guide

StorTrends 3400 Hardware Guide for Onsite Support


D/N VANDAL RESISTANT 700TVL VARI-FOCAL IR DOME CAMERA CMR6082X/6082MX3.6 N/P CMR6086X/6086MX3.6 N/P

MPA-101. WARNING: Improper installation could result in damage to the amplifier and/or speakers. Read all instructions before installation.

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Achat 115MA full-range speaker. user manual

Peak Atlas IT. RJ45 Network Cable Analyser Model UTP05. Designed and manufactured with pride in the UK. User Guide

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

HDTV Anywhere USER MANUAL / HDTV Anywhere ALL RIGHTS RESERVED MARMITEK

HP UPS R1500 Generation 3

EMBEDDED ACCESS CONTROL Hardware Installation Guide

AM/FM ALARM CLOCK RADIO

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

S/PDIF D/A Converter. User Manual. Rev.B, December 2011 Audial d.o.o Belgrade, Serbia

CELO5. User & Installation Manual.

ES-CAM2AU IP Camera.

User Manual Revision English

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

Evolution Digital HD Set-Top Box Important Safety Instructions

CAUTION RISK OF ELECTRIC SHOCK NO NOT OPEN

12-Volt 10-Amp Regulated Power Supply

Cable Tester Pro ORDERCODE D1909

Accessory Packages for the Allegiant

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

Hot Water Urns. all models. Helpline. v3.0

Cisco TelePresence MCU 4500 Series safety and compliance information

ENGLISH USER S MANUAL. compact handheld 1D/2D code scanner

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

ATTENTION RISQUE D ÉLECTROCUTION! NE PAS OUVRIR!

D/N VANDAL RES. VARI-FOCAL IR DOME CAMERA

Model PS-4001 Power Supply User Instructions

Technical Information

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Congratulations! Thank you!

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

LDG DTS-4/4R Desktop Coaxial Switch / Remote

BIG GAMES HOME VIDEO ARCADE ASSEMBLY INSTRUCTIONS

DE1600 DSA E-Series iscsi Disk Arrays. Installation Manual

CMP30. User Manual.

BOSE. Link AL8 HOMEWIDE WIRELESS AUDIO LINK

MS-800B Mobile Video Studio

Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

Single Day Alarm Clock with. Bluetooth and USB Play-through

INSTALLATION GUIDE 1

COMPANION 20 MULTIMEDIA SPEAKER SYSTEM. Owner s Guide Guía de usuario Notice d utilisation

User Guide. HDMI Active Cable Extender. DVI-7370c

PORTABLE ALARM CLOCK. Dual Alarm. FM Radio. Wake-up Sounds. USB Phone Charger G-1CR

D/N VANDAL RES. VARI-FOCAL DOME CAMERA

If you are familiar with these matters, then you can use this manual as a work of reference.

Advantium 2 Plus Alarm

LEDPAR64 USER MANUAL

PXL-250: Network Wiring

BX7000 Multi-Access Gateway Getting Started Guide

MANUAL ENGLISH MHS-30S. Ordercode: D6544. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

INDOOR MINI DOME CAMERA

Plena Two-zone Call Station. Installation and User Instructions PLE-2CS

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

IMPORTANT SAFETY INSTRUCTIONS

Modular I/O System Analog and Digital Interface Modules

CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN

User Manual Revision English

Product Guide Specification

Communication bridge Xcom-MS User Manual

IFS SP-PoE Splitter User Manual

Installation Instructions for FT-10 Network PowerCommand ATS Communication Module (NCM) Kits and

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

HM-W536 Install Guide

HP SATA/SAS hard drive and Solid State Drive installation

Transcription:

MIC-BP4 Bi-Phase Converter Card for the MIC400 PTZ Camera Series Bosch Security Systems EN Installation and Operation Manual

BP4 Bi-phase card Installation and Operation Manual AAAEN 2 MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera Chapters 1. Introduction 2. MIC-BP4 Bi-phase Converter Card 3. Technical Specifications

BP4 Bi-phase card Installation and Operation Manual AAAEN 3 Introduction... 1-6 MIC-BP4 Bi-Phase Converter Card... 1-7 Versions... 1-7 Features... 1-7 Unpacking... 1-7 Package Contents... 1-7 Intentionally Blank MIC-BP4 Bi-phase Converter Card..... 2-8 Bi-phase Telemetry Specifications 2-8 Typical Wiring Example.. 2-9 Installation of the MIC-BP4 Bi-phase Converter Card 2-9 Setting the MIC400 address (in hardware)... 2-10 Troubleshooting 2-10 MIC Address DIP Switch Settings... 2-11 Technical Specifications... 3-12 Technical Specifications. 3-12

BP4 Bi-phase card Installation and Operation Manual AAAEN 4 Safety Precautions The following symbols are used throughout this manual please pay careful attention to their meaning. The lightning flash with an arrowhead symbol within a triangle is intended to alert the user to the presence of non-insulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within a triangle is intended to alert the user to the presence of important safety, operating and maintenance (servicing) instructions in the literature accompanying the appliance. Important Safety Instructions CAUTION TO REDUCE THE RISK OF ELECTRICAL SHOCK, DISCONNECT POWER SUPPLY BEFORE OPENING THE POWER SUPPLY UNIT. POWER DISCONNECT: POWER SUPPLY UNITS HAVE POWER SUPPLIED WHENEVER THE POWER CORD IS INSERTED INTO THE POWER SOURCE 1. Read all instructions prior to installation. 2. Keep this manual for future reference. 3. Heed all warnings. 4. Install according to manufacturer s instructions. 5. Qualified persons only should install this product, if in doubt consult a qualified installer. 6. Use correct electrostatic discharge handling procedures when handling printed circuit boards to avoid damage to electro-sensitive components. 7. Do not install near any strong heat sources such as furnaces. 8. Never push objects or pour liquids into the product enclosure as this can cause a fire or electrical shock hazard. 9. Only use electronic cleaning solvent in the unlikely event of the card requiring cleaning. 10. Ensure that the product is correctly earthed. 11. Use only the power sources indicated in this user guide and ensure that the current rating of the supply cable is adequate for the product. 12. Do not overload power supply sockets as this can be a fire or electrical shock hazard. 13. In the event of failure do not attempt to service this product yourself, please contact Bosch Security Systems for assistance. 14. Only use approved attachments or accessories specified by the manufacturer. Any changes or modifications made to the equipment, not expressly approved in writing by Bosch Security Systems, could prevent proper or safe operation of the product and will invalidate the warranty. 15. Please dispose of disused electrical & electronic equipment at an environmentally compatible recycling facility (contact Bosch Security Systems for further details). WARNING INSTALLATION SHOULD BE CARRIED OUT BY QUALIFIED PERSONNEL ONLY IN ACCORDANCE WITH THE APPLICABLE LOCAL CODES. BOSCH SECURITY SYSTEMS ACCEPTS NO LIABILITY FOR ANY DAMAGES OR LOSSES CAUSED DUE TO INCORRECT OR IMPROPER INSTALLATION

BP4 Bi-phase card Installation and Operation Manual AAAEN 5 This product complies with the following EC directives:- EMC Directive (89/336/EC as amended) Machinery Directive (98/37/EC) LV Directive (73/23/EC) RoHS (Restriction of Hazardous substances) 2002/95/EC WEEE (Waste Electrical & Electronic Equipment) 2002/96/EC Reference Glossary of Terms PTZ - Pan/Tilt/Zoom Bi-phase - Bosch Bi-phase telemetry protocol (see pg8) PSU - Power Supply Unit IR - Infra Red (MIC cameras with IR lamps MUST use an IR psu) MIC-BP4 - Bi-phase converter card for non-ir power supplies STP - Shielded Twisted Pair cable This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local supplier for procedures for recycling this equipment.

BP4 Bi-phase card Installation and Operation Manual AAAEN 6 Intentionally Blank CHAPTER 1 Introduction The MIC-BP4 Bi-phase converter card allows translation of the Bosch Bi-phase protocol signals to RS485, half duplex telemetry signals. This enables Bosch Security Systems MIC400 series PTZ cameras to interface with Bosch Bi-phase equipment. The MIC-BP4 Bi-phase converter card also enables the camera address to be set through its integrated DIP switch selector.

BP4 Bi-phase card Installation and Operation Manual AAAEN 7 Versions This manual covers the installation and operation of Bosch Security Systems MIC-BP4 Bi-phase converter card can be fitted in MIC400 power supplies which have a free expansion slot (header CN2). For MIC400IR cameras please refer to the MIC-BP3 Bi-phase converter card manual. For customers requiring RS485 to Bosch Bi-phase protocol translation using other MIC400 power supply variants; please refer to the following list to select the correct card for the appropriate power supply:- Converter Card Type MIC-BP3 - Card is mounted in an external enclosure for PSU s Without an expansion slot available (header CN2), can be used with any MIC-PSU. MIC-BP4 - Plug in card for power supplies were the CN2 expansion slot is available. MIC PSU BP Converter Card Type MIC-IR-PSU (all types) - CAUTION: The MIC-BP4 converter card can only be used with MIC400 Non - IR variant power supplies due to a lack of an expansion slot in the IR variant power supplies. Please ensure the correct Bi-phase card for the type of power supply is used (see below). No expansion slot; BP3 Only MIC-240PSU - 1 expansion slot; BP3 or BP4 MIC-12PSU - 1 expansion slot; BP3 or BP4 MIC-24PSU - 1 expansion slot; BP3 or BP4 MIC-115PSU - 1 expansion slot; BP3 or BP4 MIC-THERMAL-PSU - 1 expansion slot; BP3 or BP4 MDPS PSU s - BP3 or BP4 depending on availability of expansion slot. Unpacking Check the exterior of the packaging for visible damage. If any items appear to have been damaged in transit please inform the shipping company. Unpack the card carefully; this is electronic equipment and should be handled with care. Do not use if any component appears to be damaged. Please contact Bosch Security Systems in the event of damaged goods. The shipping carton is the best way to transport the unit, save it and all other packaging materials for future use. If the part must be returned, use the original packing materials. Packaging Contents Please check for the following contents CAUTION: Use proper ESD handling precautions to avoid electrostatic discharge. Wear a grounded wrist strap to prevent damage when handling electro-sensitive printed circuit boards. MIC-BP4 Bi-Phase converter card installation manual (this guide) MIC-BP4 Bi-Phase card

BP4 Bi-phase card Installation and Operation Manual AAAEN 8 CHAPTER 2 MIC-BP4 Bi-phase Converter Card Bi-phase Telemetry Specifications Picture 1 The MIC-BP4 Bi-phase converter card for MIC400 series power supplies. Shielded 2-wire, half-duplex, multi-drop, 5000 ft. cable limit, 18AWG gauge needed for 500ft distance. Bi-phase is the standard Bosch protocol used to send Pan/Tilt/Zoom control over 2-wire shielded twisted pair (STP) terminated with an 110Ω terminal resistor. Cable Type Distance Transmission Rate Gage Termination Terminal Connector Voltage STP - Shielded Twisted Pair 1524 m (5000 ft) Belden 8760 recommended 31.25 KHz 1.02 mm (18 AWG) 110 Ω Screw terminals 4 Vp-p Figure 1 below illustrates the connections necessary for Bi-phase operation. The Bi-phase converter card allows Bosch control systems with Bi-phase output to control up to eight (8) non-ir MIC400 series camera via their associated power supply units. 1 Bi-phase to RS485 Converter PCB 2 Bi-phase output on Control System 3 HD2 Screw Terminal Header Figure 1: Connections for Bi-phase

BP4 Bi-phase card Installation and Operation Manual AAAEN 9 The MIC-BP4 has a 110 Ω termination resistor between the Bi-phase +ve and ve terminals which should be removed unless the camera is the last in the daisy chain of cameras. Typical Wiring Example CAUTION: The shield must be connected to the controller end only In a daisy chain configuration (as shown in Figure 2 below), a termination resistor of 110 Ω must be added to the last MIC400 in the series. You can daisy chain a maximum of eight (8) MIC400 s per Bi-phase output. Installation of the MIC-BP4 Bi-phase Converter Card 1. The power supply unit should be switched off and unplugged prior to carrying out any work. 2. Ensure that the four (4) card spacer supports fitted in the power supply are positioned in the centre and right most mounting holes on the power supply printed circuit board, so that the MIC-BP4 card is supported in each corner. 3. To reposition the card spacers first remove the four (4) screws holding the power supply PCB to the enclosure, turn the PCB over and remove the two (2) card spacer supports at the right hand positions (labelled A on Figure 3), these spacers should be re-fixed at the middle positions (labelled B on Figure 3). 4. Connect the Bi-phase +, Bi-phase - signals in the Shielded Twisted Pair (STP) cable from the control system to the appropriate HD2 screw terminals (as shown in Figure 1). 5. Insert the MIC-BP4 card into the connector labelled CN2 (labelled C on Figure 3) on the PSU, and screw to the card spacer supports using M3x6 screws. 6. Switch on the power supply unit. 7. A status LED will flash (every 3 seconds) indicating the operation of the BP4 Bi-phase converter. 8. To verify the Bi-phase signal are being received and converted, send a PTZ commands from the control system. The status LED will flash whilst commands are being converted to RS485. Figure 2: Daisy chain configuration for Bi-phase controller

BP4 Bi-phase card Installation and Operation Manual AAAEN 10 CAUTION: The shield must be connected to the controller end only Figure 3 Layout of a MIC400 Non-IR Power Supply PCB (MIC-240PSU, MIC-012PSU, MIC-024PSU & MIC-115PSU) Setting the MIC400 Address (in Hardware) The MIC-BP4 Bi-phase converter card supports changing the address of the MIC400 at the pole base through hardware. It should be noted that the MIC-BP4 converts all Bi-phase data into RS485 data regardless of the address setting on the DIP switches. The MIC400 will filter and process commands that match the current address of the MIC400. The address setting procedure is as follows: 1. Select the appropriate address (1-255) by setting up the DIP switches. (See tables below) 2. Press the push button (SW2) adjacent to the DIP switches to set the address. 3. The status LED will flash once indicating the start of the address setting procedure. You should then observe the MIC400 panning this confirms that the MIC400 has been set to the new address. 4. The status LED will be illuminated for the duration of this procedure. Troubleshooting 1. The status LED does not flash when sending commands from the control system. a. Check the polarity of Bi-phase signal cables connected on the MIC-BP4. b. Ensure the power supply is switch on.

BP4 Bi-phase card Installation and Operation Manual AAAEN 11 1 to 127 DIP Switch Address Settings for MIC400 series cameras 128 to 255 DIP Switch Address Settings for MIC400 series cameras

BP4 Bi-phase card Installation and Operation Manual AAAEN 12 CHAPTER 3 Technical Specifications Contact Physical Dimensions and Cable Specification MIC-BP4 card dimensions 60 mm (W) x 10mm (H) x 70mm (D) Recommended cable type Cable Type Distance Transmission Rate Gage Termination Terminal Connector Voltage STP - Shielded Twisted Pair 1524 m (5000 ft) Belden 8760 recommended 31.25 KHz 1.02 mm (18 AWG) 110 Ω Screw terminals 4 Vp-p Bi-phase Specifications: - Shielded 2-wire, half-duplex, multi-drop, 5000 ft cable limit, 18 AWG gauge wire needed for 5000ft distance. Americas Bosch Security Systems Inc 850 Greenfield Road Lancaster Pennsylvania 17601 USA Telephone +1 888-289-0096 Fax +1 585-223-9180 Email: security.sales@us.bosch.com www.boschsecurity.us Europe, Middle East, Africa Bosch Security Systems B.V P.O Box 80002 5600 JB Eindhoven The Netherlands Phone +31 40 2577 284 Fax +31 40 2577 330 emea.securitysystems@bosch.com www.boschsecurity.com Asia-Pacific Bosch Security Systems Pte Ltd 38C Jalan Pemimpin Singapore 577180 Phone +65 6319 3450 Fax +65 6319 3499 apr.securitysystems@bosch.com www.boschsecurity.com Bosch Security Systems B.V, 2009, Data subject to change without