Air Conditioners Technical Data



Similar documents
Air Conditioners Technical Data

The natural ombination

Cooling kw Heating kw

DAikin Altherma low temperature heat pump. end user leaflet

The natural ombination

Daikin Altherma hybrid heat pump. The natural combination

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Air Conditioners. Technical Data. Wall Mounted Unit. RX-JV/GV

Daikin Altherma. hybrid heat pump. The natural combination

Inverter technology. bulletin

your comfort. our world. R22 replacement A complete solution for R22 Sky Air systems

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

emura Form. redefined.

R-32. The next generation refrigerant for air conditioners and heat pumps

your comfort. our world. DNSS EcoSave A/C remote monitoring and malfunction prediction

Air conditioners Heating & Cooling

your comfort. our world. Daikin Aftercare Service For total peace of mind

URURU SARARA: THE AIR CONDITIONER THAT COOLS, HEATS, HUMIDIFIES, DEHUMIDIFIES, PURIFIES AND VENTILATES;

Air Conditioners Technical Data

COMFORT ALL YEAR ROUND HEATING AND COOLING SOLUTIONS FOR YOUR HOME

elcome to the era of the SEER seasonal efficiency Product range

Fan Coil Units. Fan coil units with brushless DC motor with inverter. your comfort. our world. » Up to 70% energy saving with BLDC motor technology

Hotel solutions. for hotel owners. Heating - air conditioning - hot water - ventilation - refrigeration - control

NETWORK SOLUTIONS.

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

Air conditioners, Heating & Cooling. Biddle air curtain for connection to daikin heat pumps.

air conditioners for your home, shops, restaurants, offices, small hotels w w w. d a i k i n. e u M U L T I M O D E L A P P L I C A T I O N S

Daikin Altherma Hybrid Heat Pump

HP switch LP switch Discharge thermo Comp. Surface thermo

Ururu Sarara. The best of the best

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

LG Electronics AE Company, Commercial Air Conditioning

Daikin Altherma Hybrid Heat Pump

Daikin Altherma Hybrid Heat Pump

PLUG and PLAY VRV Connection

ARMSTRONG AIR HEAT PUMPS

Appendix - Controllers 179

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SASO XXXX:2016. (Including the modifications approved in Saudi Council Board No. XXX/2016) LARGE CAPACITY AIR CONDITIONERS

Split units TH with hermetic compressors

york air-conditioning products Residential & VRF News 2015

LG Air conditioning Company Multi V Water Ⅱ. Air Conditioning Academy

ECOCIAT. Domestic hot water heat recovery unit

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

The natural. hoice INSTALLER LEAFLET DAIKIN ALTHERMA LOW TEMPERATURE HEAT PUMP

Air-Conditioning Buying Guide

AIR CONDITIONING EFFICIENCY F8 Energy eco-efficiency opportunities in Queensland Foundries

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

SALES BULLETIN. Key Features. New 7 Series Under Ceiling Indoor Units

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

KSV70HRF. KSV70HRF - 7.1kW Split System Air Conditioner - Reverse Cycle

Local Dealer:

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

IV. Rear Mount System

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

Split System Heat Pump Product Data

Inverter Air Conditioning for Light Commercial Use

MovinCool Office Pro Series. The Portable Spot Cooling Solution

CRAC Precision climate control units for data centres

Transformer oil cooler ALFA A02

HEAVY DUTY STORAGE GAS

marine/bespoke split applications

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

FULL DC INVERTER SYSTEMS

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

AIR-CONDITIONER SPLIT TYPE

Split System Cooling Product Data

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Split System Heat Pump Product Data

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

Refrigeration Basics 101. By: Eric Nelson

U-MATCH Air Conditioners. Service Manual. T1/R410a/50Hz

AIR CONDITION & REFRIGERATION INSTALLATION & REPAIR

HVAC Systems: Overview

Glossary of Heating, Ventilation and Air Conditioning Terms

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

Electronic Control Devices The European Product Catalogue 2007

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Unico Inverter. Unique and efficient.

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

2 NOMENCLATURE 3 FUNCTION 4 PRODUCT DATA

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Air Conditioner Cooling Capacity Test AS/NZS :1998

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

CAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU

Transcription:

Air Conditioners Technical Data C e i l i n g s u s p e n d e d u n i t E E D E N 2-0 0 FHQ-B8

Indoor Unit Ceiling suspended unit FHQ-B8 TABLE OF CONTENTS FHQ-B8 Features............................................................. 2 2 Specifications....................................................... 3 Technical Specifications............................................. 3 Electrical Specifications.............................................. 3 3 Safety device settings............................................. 4 Safety Device Settings............................................... 4 4 Options.............................................................. 5 Options............................................................... 5 5 Dimensional drawings............................................. 6 Dimensional Drawings............................................... 6 6 Piping diagrams.................................................... 8 Piping Diagrams..................................................... 8 7 Wiring diagrams.................................................... 9 Wiring Diagrams - Single Phase.................................... 9 8 External connection diagrams................................... 0 External Connection Diagrams...................................... 0 9 Sound data......................................................... Sound Pressure Spectrum.......................................... 0 Air flow patterns................................................... 2 Air Flow Pattern - Cooling........................................... 2 Air Flow Pattern - Heating........................................... 4 Split - Sky Air Indoor Unit

tk ui sn - g nr t io i ol - l di pn e IF Indoor Unit Ceiling suspended unit FHQ-B8 Features s S U 8 B Q H C S Seasonal efficiency, optimized for all seasons. Seasonal efficiency gives an indication on how efficient an air conditioner operates over an entire heating or cooling season. Can be installed in both new and existing buildings Ideal for use in larger areas Heat pumps are all-in-one heating & cooling solutions for residential & commercial applications. They extract thermal energy from the ambient air and are therfore more energy efficient and emit far less CO2 than comparable fossil fuel based boiler systems. Wider air discharge thanks to Coanda effect: up to 00º Air flow distribution for ceiling heights up to 3.8m without capacity loss The unit can easily be mounted in corners and narrow spaces, as it only needs 30mm lateral service space 2 steps 2 Split - Sky Air Indoor Unit

2 Specifications Indoor Unit Ceiling suspended unit FHQ-B8 2- Technical Specifications FHQ35B8 FHQ50B8 FHQ60B8 Power input Cooling Nom. kw 0. 0.5 Heating Nom. kw 0. 0.5 Casing Colour White Dimensions Unit Height/Width/Depth mm 95/960/680 95/,60/680 Packed unit Height/Width/Depth mm 279/,046/88 279/,246/88 Weight Unit kg 24 25 27 Packed unit kg 3 32 35 Heat exchanger Length mm 722 922 Rows Quantity 2 3 2 Fin pitch mm.75 Passes Quantity 6 Face area m² 0.82 0.233 Stages Quantity 2 Empty tubeplate hole Quantity 0 2 0 Tube type Cross fin coil (Multi louver fins and N-hix tubes) Fan Type Sirocco fan Quantity 3 4 Air flow rate Cooling High m³/min 3 7 Low m³/min 0 3 Heating High m³/min 3 6 Low m³/min 0 3 Fan motor Model 3D2KAA 4D2KAA Speed Steps 2 Output High W 62 Phase x Voltage V x 220-240 Sound power level Cooling High/Low dba 53/48 54/49 55/49 Heating High/Low dba 53/48 54/49 55/49 Sound pressure level Cooling High/Low dba 37/32 38/33 39/33 Heating Super high/high/low dba -/37/32 -/38/33 -/39/33 Refrigerant Type R-40A Piping connections Sound absorbing insulation Foamed polyurethane / Glass wool Liquid Type/OD mm Flare connection/6.35 Gas Type/OD mm Flare connection/9.5 Flare connection/2.7 Drain VP20 (I.D. 20/O.D. 26) Heat insulation Foamed polystyrene / Foamed polyethylene Standard Accessories : Operation manual; Standard Accessories : Installation manual; Standard Accessories : Paper pattern for installation; Standard Accessories : Drain hose; Standard Accessories : Clamp metal; Standard Accessories : Insulation for fitting; Standard Accessories : Sealing pads; Standard Accessories : Clamps; Standard Accessories : Washer for hanger bracket; 3 2 2-2 Electrical Specifications FHQ35B8 FHQ50B8 FHQ60B8 Power supply Name V Phase ~ Frequency Hz 50 Voltage V 220-240 Current - 60Hz Nominal running current A - Split - Sky Air Indoor Unit 3

3 Safety device settings 3 - Safety Device Settings Indoor Unit Ceiling suspended unit FHQ-B8 3 ± ± ± 4 Split - Sky Air Indoor Unit

Indoor Unit Ceiling suspended unit FHQ-B8 4 Options 4 - Options 3 4 Split - Sky Air Indoor Unit 5

5 Dimensional drawings 5 - Dimensional Drawings Indoor Unit Ceiling suspended unit FHQ-B8 5 6 Split - Sky Air Indoor Unit

Indoor Unit Ceiling suspended unit FHQ-B8 5 Dimensional drawings 5 - Dimensional Drawings 3 5 Split - Sky Air Indoor Unit 7

6 Piping diagrams 6 - Piping Diagrams Indoor Unit Ceiling suspended unit FHQ-B8 6 8 Split - Sky Air Indoor Unit

Indoor Unit Ceiling suspended unit FHQ-B8 7 Wiring diagrams 7 - Wiring Diagrams - Single Phase 3 7 Split - Sky Air Indoor Unit 9

Indoor Unit Ceiling suspended unit FHQ-B8 8 External connection diagrams 8 - External Connection Diagrams 8 0 Split - Sky Air Indoor Unit

Indoor Unit Ceiling suspended unit FHQ-B8 9 Sound data 9 - Sound Pressure Spectrum 3 9 Split - Sky Air Indoor Unit

0 Air flow patterns 0 - Air Flow Pattern - Cooling Indoor Unit Ceiling suspended unit FHQ-B8 0 2 Split - Sky Air Indoor Unit

Indoor Unit Ceiling suspended unit FHQ-B8 0 Air flow patterns 0 - Air Flow Pattern - Cooling 3 0 Split - Sky Air Indoor Unit 3

0 Air flow patterns 0-2 Air Flow Pattern - Heating Indoor Unit Ceiling suspended unit FHQ-B8 0 4 Split - Sky Air Indoor Unit

Indoor Unit Ceiling suspended unit FHQ-B8 0 Air flow patterns 0-2 Air Flow Pattern - Heating 3 0 Split - Sky Air Indoor Unit 5

Daikin s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste. The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V. EEDEN2-00 Please fill out the requested information Please fill out the requested information Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com Daikin products are distributed by: Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 042 20 336 - RPR Oostende EEDEN2-00 02/2 Copyright Daikin The present publication supersedes EEDEN-00 Printed on non-chlorinated paper. Prepared by Goekint Graphics NV, Belgium Responsible Editor: Daikin Europe N.V., Zandvoordestraat 300, B-8400 Oostende