SpO2 PULSE OXYMETER MD-300



Similar documents
Instructions to User

Instructions to User

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

EM90 INFRA-RED THERMOMETER & THERMOCOUPLE METER

Alkaline Manganese (Mercury free) IEC: LR03; JIS: AM-4; ANSI: AAA; MN2400; Micro chemical system: Zn / KOH-H 2 O / MnO 2

OMNI TOUCH SCREEN PATIENT MONITOR


USB-500 Series Stand-Alone, Low-Cost Data Loggers

Critical Care Therapy and Respiratory Care Section

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Name: OMRON M3 HEM-7200-E Upper Arm Blood Pressure Monitor

EMMA Emergency Capnometer/ Finger Pulse Oximeter Version 2 Related Documents SOP-Medical and Equipment packs Stuart Daly; Phil Munro

USB-500 Series Low-Cost Data Loggers and Accessories

Android based Alcohol detection system using Bluetooth technology

A project to optimise quality and energy efficiency must include metering

5000V Graphical Megohmmeter Model 5070

SMS GSM Alarm Messenger

User Manual. Humidity-Temperature Chart Recorder. Model RH520

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Model POWER QUALITY ANALYZERS, METERS & LOGGERS Power Quality Meter

Atomic Alarm Clock Instruction Manual

Technical Specification for Model RSK2503 (Z)-06A IR Belt Solar Cell Firing Furnace

Model UT33A: OPERATING MANUAL Table of Contents (1)

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter TDR900. Hand-held Time Domain Reflectometer/Cable Length Meter

User Guide. 4 wire Earth Resistance Tester Model GRT300

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

Dual Laser InfraRed (IR) Thermometer

Handheld portable appliance testers

MEDIANA Corporate Profile. Contents

USB-500/600 Series Low-Cost Data Loggers and Accessories

Agilent U1230 Series Handheld Digital Multimeters (DMMs)

Ron 3025 Crane Scale with 1"/25mm Display

Wireless Data Logger Monitoring Systems

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Thermistor Thermometer MODEL NO

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

UT202A Operating Manual. Contents

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

Multi Media Cable Tester TM-901N/TM-902/TM-903

ADC Diagnostix 2100 Fingertip Pulse Oximeter. Directions for use

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

Spirodoc. One Touch Laboratory for respiratory analysis two functional modes: doctor and patient. Spirometer with Touch Screen display

EL-USB mA Current Loop USB Data Logger

Microwave Meter. Instruction Manual

All Products of MEDIANA. All because of you,mediana will be better...

T0118 T2118 T3118. Instruction Manual

DELIVERY SPECIFICATIONS

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Boaray 700 Anesthesia Machine

Hand-held thermometer Model CTH7000

Ultrasonic Load Monitoring

Flexible Counter Series in DIN size 24 x 48 mm

DET3 and 4 Contractor Series Earth/Ground Resistance Testers

NIKY and NIKY S. UPS SINGLE-PHASE from 600 to 3000 VA GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

U1602A Handheld Oscilloscopes, 20 MHz

User Guide. Model Insulation Tester / Megohmmeter

Available Options The IR-750B, IR-750EXB, IR-16 and IR-16EX series heat tracers are available with the options listed below.

Infrared Digital Scouting Camera. User s Manual Pocket Camera

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Light Meter (Foot Candles)

Measurement data monitoring system

TORKEL 820 Battery Load Unit

Wireless Data Logger. Collect, Manage and Monitor Your Valuable Data via Wireless Communication. Register and Manage Remote Units by Groups

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

LCD Display. Function keys. Stand. Adapter socket

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Pocket Tach 99 (PT99) Non-Contact Tachometer

MIT510/2, MIT520/2 and MIT1020/2

Applications. diris_826_a_1_gb_cat

3-phase, bidirectional energy meter

IFC 070 Technical Datasheet

Fingerprint Time & Attendance. User s Manual

EX 2000/EX 2000 C/ GD 2000/GDP

Dual Laser InfraRed (IR) Thermometer

SMART SENSOR COLLECTION

LT-82 Stationary IR Transmitter

Mini InfraRed Thermometer with Laser Pointer

1. SAFETY INFORMATION

Insulation resistance testing. A complete solution for every person.

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

How To Use An Irius Pid Detector

PowerGem Pro Uninterruptible Power Supply

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Mini Video Speaker. Model: MVS01. User s Manual

MPR-Systems. Mini Power Racks 1200 W W

Power Meter Series 700

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

Model UT201/202: OPERATING MANUAL. Table of Contents

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

User's Guide. Pinless Moisture Meter. Model MO257

Wahl C50 Calibrator FEATURES

AutoRanging Digital MultiMeter

Control Location. Replacing Battery

UniOP epad33 and epad33t

Waterproof portable tracker and

Transcription:

MD-300 C MD-300 A MD-300 D MD-300 B MD-300 F MD-300 I MD-300 Z Finger clip ADULT Finger clip PEDIATRIC Soft tip ADULT Wrap ADULT -> PEDIATRIC Wrap PEDIATRIC -> NEONATE Y Type

Pulse oxymètre portable MD-300C Technical Parameters Display Format: LED SPO2:35-99% in 2-digit 7-segment digital; Pulse Ratio:30-240 BPM in 3-digit 7-segment digital; Pulse Wave: 6-segment bargraph Battery Voltage Low Indication: LED signals. * Power Requirements: Two AAA size 1.5V Alkali Battery; * Power Consumption: less than 40mA. * Resolution: ±1% for SPO2 and ±1 BPM for Pulse Ratio. * Measurement Accuracy: ±2% in stage of 70%-99% SPO2 and meaningless when stage being smaller than 70%. ±2 BPM for Pulse Ratio. * Measurement Performance in Weak Filling Condition: Oxyhemoglobin and pulse value can be shown correctly when pulse-filling ratio is 0.5%. * Interference Resistance Capacity against Ambient Light: Deviation is smaller than ±1% between value of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room. Product Properties Operation of the product is simple and convenient * The product is small in volume, light in weight (total weight is about 50g including batteries) and convenient in carrying. * Power consumption of the product is low and the two originally equipped two AAA batteries can be operated continuously for 30 hours. * Low voltage warning will be indicated in visual window when battery voltage is so low that normal operation of the Oximeter might be influenced. * The product will automatically be powered off when no signal is in the product for more than 8 seconds. Packing Dimension 15cm x 10.5cm x 4cm/pc/box Gross Weight 0.2kg/pc/box

Pulse oxymètre portable MD-300D Technical Parameters Display Format: LCD SPO2:35-99% in 2-digit ; Pulse Ratio:30-240 BPM in 3-digit; Pulse Wave: 6-segment bargraph Plethys Waveform Battery Voltage Low Indication:. * Power Requirements: Two AAA size 1.5V Alkali Battery; * Power Consumption: less than 40mA. * Resolution: ±1% for SPO2 and ±1 BPM for Pulse Ratio. * Measurement Accuracy: ±2% in stage of 70%-99% SPO2 and meaningless when stage being smaller than 70%. ±2 BPM for Pulse Ratio. * Measurement Performance in Weak Filling Condition: Oxyhemoglobin and pulse value can be shown correctly when pulse-filling ratio is 0.5%. * Interference Resistance Capacity against Ambient Light: Deviation is smaller than ±1% between value of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room. Product Properties Operation of the product is simple and convenient * The product is small in volume, light in weight (total weight is about 50g including batteries) and convenient in carrying. * Power consumption of the product is low and the two originally equipped two AAA batteries can be operated continuously for 30 hours. * Low voltage warning will be indicated in visual window when battery voltage is so low that normal operation of the Oximeter might be influenced. * The product will automatically be powered off when no signal is in the product for more than 8 seconds. Packing Dimension 15cm x 10.5cm x 4cm/pc/box Gross Weight 0.2kg/pc/box

Pulse oxymètre portable MD-300C Technical Parameters Display Format: LED SPO2:35-99% in 2-digit 7-segment digital; Pulse Ratio:30-240 BPM in 3-digit 7-segment digital; Pulse Wave: 6-segment bargraph Battery Voltage Low Indication: LED signals. * Power Requirements: Two AAA size 1.5V Alkali Battery; * Power Consumption: less than 40mA. * Resolution: ±1% for SPO2 and ±1 BPM for Pulse Ratio. * Measurement Accuracy: ±2% in stage of 70%-99% SPO2 and meaningless when stage being smaller than 70%. ±2 BPM for Pulse Ratio. * Measurement Performance in Weak Filling Condition: Oxyhemoglobin and pulse value can be shown correctly when pulse-filling ratio is 0.5%. * Interference Resistance Capacity against Ambient Light: Deviation is smaller than ±1% between value of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room. Product Properties Operation of the product is simple and convenient * The product is small in volume, light in weight (total weight is about 50g including batteries) and convenient in carrying. * Power consumption of the product is low and the two originally equipped two AAA batteries can be operated continuously for 30 hours. * Low voltage warning will be indicated in visual window when battery voltage is so low that normal operation of the Oximeter might be influenced. * The product will automatically be powered off when no signal is in the product for more than 8 seconds. Packing Dimension 15cm x 10.5cm x 4cm/pc/box Gross Weight 0.2kg/pc/box

Pulse oxymètre portable MD-300Z Technical Parameters Display Format: OLED SPO2:70-99% in 2-digit 7; Pulse Ratio:30-240 BPM in 3-digit ; Battery Voltage Low Indication: LED signals. * Power Requirements: Two AAA size 1.5V Alkali Battery; * Power Consumption: less than 40mA. * Resolution: ±1% for SPO2 and ±1 BPM for Pulse Ratio. * Measurement Accuracy: ±2% in stage of 70%-99% SPO2 and meaningless when stage being smaller than 70%. ±2 BPM for Pulse Ratio. * Measurement Performance in Weak Filling Condition: Oxyhemoglobin and pulse value can be shown correctly when pulse-filling ratio is 0.5%. * Interference Resistance Capacity against Ambient Light: Deviation is smaller than ±1% between value of Oxyhemoglobin measured in natural lighting indoor condition and present lighting sources and that measured in dark room. Product Properties Operation of the product is simple and convenient * The product is small in volume, light in weight (total weight is about 50g including batteries) and convenient in carrying. * Power consumption of the product is low and the two originally equipped two AAA batteries can be operated continuously for 30 hours. * Low voltage warning will be indicated in visual window when battery voltage is so low that normal operation of the Oximeter might be influenced. * The product will automatically be powered off when no signal is in the product for more than 8 seconds. * Size: 58mm(L), 32mm(W), 34mm(H) Packing Dimension 15cm x 10.5cm x 4cm/pc/box Gross Weight 0.2kg/pc/box

Pulse oxymètre portable MD-300A Technical Specifications [Patient Range]: Adult, Pediatric and Neonatal [SpO2] Range 0%-100% Resolution 1% Accuracy 70%-100%: ±2% 0%-69%:unspecified Method Dual wavelength LED [Heart (Pulse) Rate] Range 25-254 bpm Resolution 1bpm Accuracy ±2bpm or ±2% [Alarm] Alarm SpO2, probe off Modes Audio, visual, information [Display] Type Backlit LCD Parameters SpO2, PR, Pleth waveform, Pleth bar. Information SpO2 & PR trend, browse, Low power, error, time [Environmental] Operating Temperature 0-50 Storage Temperature -10-60 Operating Humidity 15%RH - 95%RH Storage Humidity 10%RH - 95%RH [Classification] Type of protection internally powered equipment Safety IEC Standard 61601-1-1 [Storage] Data records up to 1,440 [Michanical] Size 150 x 94 x 47 mm [Battery] Type 4 AA Alkaline batteries or 4 AA rechargeable batteries Operation time Approximately 24 hours for normal operation

Pulse oxymètre portable MD-300B Technical Specifications [Patient Range] Adult, Pediatric and Neonatal [SpO2] Range 0%-100% Resolution 1% Accuracy 70%-100%: ±2% 0%-69%:unspecified Method Dual wavelength LED [Heart (Pulse) Rate] Range 25-254 bpm Resolution 1bpm Accuracy ±2bpm or ±2% [Alarm] Alarm SpO2, probe off Modes Audio, visual, information [Display] Type 3-digit 7-segment LED Parameters SpO2, PR, Pleth waveform, Pleth bar. Information SpO2 & PR trend, browse, Low power, error, time [Environmental] Operating Temperature 0-50 Storage Temperature -10-60 Operating Humidity 15%RH - 95%RH Storage Humidity 10%RH - 95%RH [Classification] Type of protection internally powered equipment Safety IEC Standard 61601-1-1 [Storage] Data records Store and replay 72 hours SPO2% and Pulse rate value [Mechanical] Size 120 60 22mm Weight: 120 g [Battery] Type 4 AAA Alkaline batteries or 4 AAA rechargeable batteries Operation time About 48 hours for normal operation

Pulse oxymètre portable MD-300I Technical Specifications [Patient Range] Adult, Pediatric and Neonatal [SpO2] Range 0%-100% Resolution 1% Accuracy 70%-100%: ±2% 0%-69%:unspecified Method Dual wavelength LED [Heart (Pulse) Rate] Range 25-254 bpm Resolution 1bpm Accuracy ±2bpm or ±2% [Alarm] Alarm SpO2, probe off Modes Audio, visual, information [Display] Type LCD Parameters SpO2, PR, Pleth waveform, Pleth bar. Information SpO2 & PR trend, browse, Low power, error, time [Environmental] Operating Temperature 0-50 Storage Temperature -10-60 Operating Humidity 15%RH - 95%RH Storage Humidity 10%RH - 95%RH [Classification] Type of protection internally powered equipment Safety IEC Standard 61601-1-1 [Storage] Data records Store and replay 24 hours SPO2% and Pulse rate value, Data output to PC [Mechanical] Size 120 60 22mm Weight: 120 g [Battery] Type 4 AAA Alkaline batteries or 4 AAA rechargeable batteries Operation time About 30 hours for normal operation