Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:



Similar documents
Ambient Temperature Operation and Matching MAN B&W Two-stroke Engines

12 November 2008 *** I:\CIRC\MEPC\01\642.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Engine Room Console 6

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

Unit 96: Marine Propulsion Power Plant

Engine Power Plant 5,2 MW Stationary Dual Fuel (Diesel / Gas ) Engine (12 VDS 48/42 )

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

UTILITIES DEPARTMENT NORTH CAMPUS DISASTER RECOVERY PLAN

Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Committed to make a better world

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

NEW JERSEY CENTER OF EXCELLENCE

REMOTE MONITORING AND CONTROL OF THE KAKKONDA GEOTHERMAL POWER PLANTS

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

GLOBACON 05 HVAC Systems for Cogen

water is cooled in a secondary cooling control tasks: use of seawater. Treatment of the seawater formation of algal vegetation.

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

IEA Workshop Copenhagen Small scale biomass co-generation with modern steam engines

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

Floating. Diesel power stations

Technical Specification. Generating Set with Waukesha engine burning natural gas

CyberFortress Data Center at Innovation Park Infrastructure and Topology Guide. Innovation Park Charlotte. NC DRAFT V0.

Data Realty Colocation Data Center Ignition Park, South Bend, IN. Owner: Data Realty Engineer: ESD Architect: BSA LifeStructures

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

21.1 Functions, Basic Configuration, and Interfaces

Top Technology for Industry, Agriculture, Business and Communities

Wind-Diesel Hybrid System Options for Alaska. Steve Drouilhet National Renewable Energy Laboratory Golden, CO

BIOPOWER 5 CEX. 1 Wärtsilä 10 January 2012 Presentation name / Author

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Factory owners must ensure the boiler is:

A CASE STUDY: PERFORMANCE AND ACCEPTANCE TEST OF A POWER AND DESALINATION PLANT. Keywords : Power Plant, Boiler Capacity, Electrical Power

TYPE APPROVAL CERTIFICATION SCHEME MASS PRODUCED DIESEL ENGINES

Diesel Generating Set

Tier III emission technology

Annex-A TECHNICAL SPECIFICATION

IMO WORK PROGRAMME OF THE COMMITTEE AND SUBSIDIARY BODIES

Periodically Unattended Machinery Space

Designed for multi-injector endurance testing, the

HEAVY DUTY STORAGE GAS

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Circuit breaker panel. Power supply for condensing unit. Power supply for furnace. Air handler (Furnace)

Columbia University Master Planning & Optimization

Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6

Gas Turbine Power COMPACT, EFFICIENT, RELIABLE

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

Siemens turbine solutions for urban cogeneration

POLICY BULLETIN Tecumseh Compressor Company Compressor Group

Evaluate, Clean, and Tune Guidance

Automatic Back-Flushing Filter AutoFilt RF9.

SYLLABUS For BASIC TRADE COURSE (360 Hours) On REFRIGERATION AND AIR CONDITIONING

Mechanical Engineering Technician- Plant Technician

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Toolbox 2 ENERGY AUDITING IN INDUSTRY

Diesel Engine Driven Generators Page 1 of 6

Why and How we Use Capacity Control

Medical Air Systems: Scroll

University of Maryland College Park District Energy System. IDEA Campus Energy Conference February 9, 2012

Table Z. Troubleshooting Chart for Air Conditioners. Cause

Boiler & Pressure Vessel Inspection discrepancies and failures

HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

ENERGY CONSERVATION PRESENTATION BY : PCG CORPORATION

A S Y N C H R O N O U S M O T O R S

Ship Propulsion/Electric Power Hybrid System Recovering Waste Heat of Marine Diesel Engine

EXPERIMENT NO. 3. Aim: To study the construction and working of 4- stroke petrol / diesel engine.

Turbo generators Best quality for thermal power plants

Building Energy Systems. - HVAC: Heating, Distribution -

ELECTRODE BOILERS VAPOR POWER INTERNATIONAL


Design and Test Operation Performance of 1,500 C Class Gas Turbine Combined-Cycle Power Plant:

OUTCOME 2 INTERNAL COMBUSTION ENGINE PERFORMANCE. TUTORIAL No. 5 PERFORMANCE CHARACTERISTICS

1.3 Turbochargers are categorised in three groups depending on served power by cylinder groups with:

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

AUTOMOTIVE AIR CONDITIONING SYSTEM.

NYC Department of Education Building Condition Assessment Survey BROADWAY EDUCATION CAMPUS - MANHATTAN, 26 BROADWAY, MANHATTAN, NY, 10004

Fully automatic air conditioning service! Bosch ACS 600, 601 and 650 for the workshop

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

Routine and Emergency Boiler Operation

Tour of new eircom Data Centre Blanchardstown by Dervan Engineering Consultants 11 th March 2015

Unit 24: Applications of Pneumatics and Hydraulics

ENERGY MANAGEMENT. for INDUSTRY AND BUSINESS


US Heavy Duty Fleets - Fuel Economy

Turbo Tech 101 ( Basic )

Federal Wage System Job Grading Standards for Air Conditioning Equipment Operating, Table of Contents

Skoda Supercritical Steam Turbine 660 MW

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Unit 1 Turbine Rotor 110 MW Replacement

Federal Wage System Job Grading Standards for Electric Power Controlling, Table of Contents

Fuel Treatment and Conditioning Systems

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

LANDFILL GAS TO ENERGY- COMBINED ENGINE AND ORC-PROCESS

How To Clean Up A Reactor Water Cleanup

Transcription:

Current state of plant Functioning as a peak and emergency centre Statistics Accumulated operating hours: D1-2-3-6-7: 43000 to 48000 hrs D4-5: 53000 to 57000 hrs D8: 33000 hrs

Layout of the plant Index: - Diesel building - 75 meter chimneys Individual exhaust pro diesel - Filter wells - Cooling water supply - Cooling water drainage - Turbine building - Separators building - Tank park - Pump building - Water treatment - Transformer cells - Transformer building 36/150 kv Facility s Diesel building Administrative wing - Social section - Technical section - Administrative section Machine Room - Diesel groups (8 pieces) - Foundation blocks Solid foundation blocks 180 m3 Loose foundation blocks 240 m3 - Compressors compressed air 25 bar: start air for diesel and steering force - Compressed air tanks - Crane (75 Ton / 5 Ton) Technical wing - Emergency services for diesels - Recuperation boilers - Silencers - Tanks for fuel, lubrication, cooling water - Degassifier - Air filters - Vacuum pumps Turbine building - Steam turbine - Auxiliary Condenser Seperator building - Four fuel seperators - Storage tanks of lubrication oil

Tank park - Fuel supply by ship or tanker - 4 tanks for extra heavy oil or palm oil (2.500 m3) - 3 tanks for purified extra heavy oil (175 m3) - 2 tanks for heating oil (300 m3) - 1 sludge tank (80 m3) - 1 waste water tank (40 m3) Local water treatment - Demineralisation installation - Storage tanks demineralised water

Composition of the plant Diesel groups General - 8 diesel groups Each group is autonomous 7 diesel groups of 10 MW 1 diesel group of 13 MW - Layout in 2 blocks 4 diesels a block 1 booster transformer (13.8 / 36 kv) per block Features of the diesels Specifications diesels 1 7 - Constructor ACEC-MAN - Type 14V 52/55 14 cylinders v shaped 52 cm bore/ 55 cm stroke - 1.000 HP pro cylinder total of 14.000 HP - Weight of 150 tons Specifications diesel 8 - Constructor ACEC-MAN - 18 cylinders with a total power of 18.000 HP Common specifications of the diesels - 428 rpm - Individuel injection pumps - Fuel consumption for each diesel 2.200 kg/h at full load Normal operation on HFO (Heavy Fuel Oil) Working on MDO (Marien Diesel Oil) during start and stop - Diesels equipped with turbos Revelations of turbo at full power are +- 10.000 rpm Combustion pressure at full load +- 2.5 bar - Efficiency +- 40% Elektrical +- 37% Fleu gas +- 23% Cooling water

Safeguards diesels Shut-down of diesel can be caust by the following safety messures - Excesive speed - Lubrication oil pressure to low - Cylinder Cooling water temperature is too high - Cylinder Cooling water temperature is too low - Injection cooling water pressure too low - Oil mist detection - Electrical safety alternator - No 110 V DC Driving circuit - No 220 V AC Control circuit Controls of diesel engines - Temperature control lubrication oil - Temperature control cylinder cooling water - Temperature control combustion air - Temperature control lubrication oil prior to separator - Viscosity control of fuel - Level control recuperation boiler - Flow control Woodward on diesel engine - Load control diesel engine Alternators - Constructor ACEC-Charleroi - Power 14.300 kva (Before Diesel 1 7) - Power 18.300 kva (Before Diesel 8) - Voltage 13,800 V - 428 rpm - Generation dynamo with external excitation 110 V DC Safeguards alternators - Surge protection - Overcurrent protection - Differential protection - Backflow protection - Ground protection stator - Ground protection rotor - Excitation control Control of alternators - Voltage control - Cos control

Secondary equipment diesels Electrically powered secondary equipment - Lubricating oil pump (110 kw) - Lubrication Oil Filter - Internal cooling pump (85 kw/ 600 m3/h) - Internal cooling water filter - Cylinder cooling water pump (37kW) - Cylinder water injection pump - Fuel pump - Viscosity meter - Leakage tank fuel - Pump daily tank filling - Lubrication oil separator - Feed pump lubrication oil separator - Feeding pump recuperation boiler - Circulation pump recuperation boiler (out of service) - Air filter - Cooling ventilator generator - Ventilators Heat exchangers - Lubrication oil cooler - Cylinder cooling water cooler - Heat exchanger cooling water injection - Turbo coolers - Heat exchangers alternator cooling - Fuel heater - Oil heater - Cylinder cooling water heater Reservoirs - Carter lubrication oil tank (10.000 l) - Cylinder lubrication oil tank - Re-greasing tank - HFO or Palm oil day tank (5.000l) - Mixing tank fuel - Leaking tank lubrication oil - Leaking tank fuel - Sludge tank lubrication oil separator - Expansion tank cylinder cooling water - Expansion tank injection cooling water Recuperation tanks Heat recuperation of exhaust gasses for the production of steam Characteristics - Exhaust gas temperature before recuperation boiler 360 C - Exhaust gas temperature after recuperation boiler 120 C - Produced steam 7 bar - 250 C - 5 Ton/h

Composition Water tube boiler - Evaporator - Super heater - Steam drum Steam turbine Auxiliary condenser Steam turbine Constructor ACEC Gent Condensation steam turbine 4 MW Drive of asynchronous generator Condenser under vacuum 8.000 RPM 1.500 RPM (30 mbar) Efficiency of the plant with steam turbine - Electric energy diesel groups +- 40 % - Cooling water loss diesel groups +- 23 % - Remaining losses diesel exhaust after heat recuperation +- 23 % - Electricity production with steam turbine +- 4 % - Cooling water loss turbine groups +- 10 % Net electric efficiency plant +- 44 % Secondary equipment steam turbine - Internal cooling pump DC motor with adjustable speed (125 m3/h) - Siphon pump - Taprogge pump - Vacuum pumps (2 pcs) - Condensate extraction pumps (2 pcs) - AC lubrication oil pump - DC auxiliary oil pump - Slip motor Safeguards steam turbine Shut down steam turbine can happen because of the following precautions - Too much speed - Pressure to high in condenser (low vacuum) - Bearing temperature too high - Lubrication oil pressure too loo - Air to cool down the generator is too hot - Electrical safety generator - No 110 V DC Driving circuit - No 380 V AC Control circuit Controls steam turbine - Speed control Woodward - Steam pressure control Askania - Level control condenser

Asynchronous generator turbine Constructor ACEC Charleroi Power 14.300 kva Voltage 13.800 V Speed 1500 rpm Safeguards Asynchronous generator turbine - Minimum voltage protection - Surge protection - Overcurrent protection - Differential protection - Backflow protection - Ground protection - Overload protection Auxiliary condenser To condense steam when the steam turbine does not function properly Switched on automatically when the steam pressure gets too high. Automatic pressure control Secondary equipment help condenser - Internal cooling water pump - Condensate extraction pump General secondary equipment Diesel engine Diesel engine 650 kva - Necessary for blackstart of the plant - Possible for parallel functioning on LS net Boiler Elboma Fire tube boiler 7 bar / 5 ton - Rotating burner functioning on MDO or palm oil - Works at lower pressure then recuperation boilers - Steam production at shut down of the plant Heating of buildings (winter) Heating fuel Heating of oil for the diesels Heating of the cylinder cooling water for the diesels Steam circuit 2 steam collectors - Steam supply by boiler Elboma or recuperation boilers Steam pressure 7 bar / 250 degrees - Supply water for boilers comes from de gassifier - Condensate collected in 3 condensation tanks Diesel building Separator building Turbine building

Fuel deposit and treatment Supply of fuel by ship or truck - Supplied fuel stored in 4 tanks - Cleaning of the fuel by means of 4 fuel separators Removal of impurities and water - Cleaned fuel stored in 3 tanks - Fuel waste (sludge) stored in sludge tank - Electric tracing for heating of the fuel lines Cooling water system Cooling water for cooling of the diesel groups and the condenser steam turbine - Dual supply channel - Double filter in stallion consisting of a coarse filter and a fine filter - Level measurement at the supply channel - Dual outlet channel - Temperature and oxygen measurement at inlet and outlet Vacuum installation Necessary for suckson at the internal water pumps - 3 vacuum pumps - Switched on 2 vacuum collectors Compressed air circuit Compressed air for diesels - 3 compressors Hatlapa for 25 bar Starting air for diesels Steering air for control - Double compressed air collector in diesel building Compressed air tools - 1 compressor for 7 bar - Entire compressed air system for the plant (7 bar) Water treatment Treatment of the water for the steam boilers - De-ironing installation - Reversed osmosis - Demineralisation Waste water Treatment of industrial waste water so in will be suitable for discharge - Rainwater from tank park, discharge location of trucks and transformer cells discharged through oil separator. - Drainage water of boilers, concentrate of reversed osmoses and regeneration water of the demineralisation installation will be discharged by a neutralisation installation. Wastewater from oil separators diesel building and separation building will be removed

Electrical installations High voltage Switchboard 13.8 kv - Double rail system - Switching cell alternators - Switching cell for transformers 13.8 kv / 36 kv (Connection with HS board 36 kv) - Switching cells for transformer 13.8 kv / 380 V (Low voltage for plant) - Connection cells between both rail systems - Longitudinal separation between the 2 blocks - Ground security switch board 13.8 kv Transformers - Transformers 70 MVA 36/13.8 kv (transformer 3 & 4) Connection between HS board 13.8 kv and HS board 36 kv - Transformers 2.200 kva 13.8 kv/380 V (transformer 1 & 2) Low-voltage for the plant (Transformer 1 for feeding block I) (Transformer 2 for feeding block II) Low voltage Low voltage boards 380/220 V AC - Net system IT net - General low voltage boards Block I & Block II - Low voltage distribution boards - Lighting boards Low voltage boards 110 V DC - General LS boards 110 V DC - Emergency lighting Control boards - Control boards for diesels and turbine - Control boards for general installations

Dispatching Monitoring and control centre Control console diesels - Separate panel per group Measurement of speed, voltage, current and temperatures Control of main switch, automatic control Alarm diesels - Central control panel - Synoptic board low voltage Alarms high voltage board 13.8 kv, low voltage boards Measurement of load, Cos Control load management, Cos control Control board turbine - Control panel turbine measurement of revolution speed, load, steam pressure Control of main switch, speed control and pressure control Alarms - Control board general services Control of lighting Distribution of 110 V DC and 220 V AC dispatch Alarms - Control board steam Measuring steam pressure Control secondary condenser Alarms - Control board fuel Alarms Control board automatic control - Distribution of power circuits 110 V DC and 220 V AC diesels - Controls speed, load, Cos - Control board synchronisation - PLC for remote monitoring central Desk dispatching - Remote control Scadacec for central and cogeneration - Telephone installation - Cameras - Access control Activities - Control of pre heating diesels - Starting auxiliary diesels - Starting general secondary machinery - Starting secondary machinery turbine and auxiliary condenser - Synchronisation of groups - Load regulations of the groups - Monitoring alarms from central