DTS / PDMS / Portable. www.mpc2001.com



Similar documents
Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

On-line PD Monitoring Makes Good Business Sense

Monitoring Underground Power Networks

SCADA and Monitoring for Solar Energy Plant

BCTC/BC Hydroʹs operational experience with Distributed Temperature Sensing (DTS) Systems for Transmission Cables. Presented by

Lastest Development in Partial Discharge Testing Koh Yong Kwee James, Leong Weng Hoe Hoestar Group

High Voltage Electrical Equipment Failure Diagnosis. Presented by: Spencer Tang & Terence Ng T&T Inspection & Engineering Sdn Bhd

PD Monitor GIS. 24/7 Partial Discharge (PD) monitoring system for Gas Insulated Switchgear. Benefits NEW PRODUCT

Distributed Temperature Sensing - DTS

Network Design. Yiannos Mylonas

CABLE MONITORING SOLUTION

ADVANCED ELECTRICAL TOPICS

CABLE ASSET MANAGEMENT PREDICT WITH CERTAINTY. Kuljit Singh BSc Honours MIEE(IET,UK) 5 June 2014

PowerPAC. Substation Reliability Services and Products

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Five Nines and Infrared (IR) Testing at Data Centers

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

AutoLog ControlMan. Remote Monitoring & Controlling Service

CUSTOMIZED ASSESSMENT BLUEPRINT COMPUTER SYSTEMS NETWORKING PA. Test Code: 8148 Version: 01

EVALUATING WAVE FILES TO DETERMINE THE SEVERITY OF THE ULTRASONIC EMISSIONS

Network and Facility Management: Needs, Challenges and Solutions

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

On-line monitoring of substation condition a Romanian experience. V. ZAHARESCU, Vl. ROSCA Nova Industrial SA. CN Transelectrica SA Romania

Monitoring and diagnostics

Executive Summary. Technical Description

OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:

Applications for Infrared Thermography at Computer Centers

Fiber Optic Distributed Temperature Sensor (B-DTS)

TrueAlarm Fire Alarm Systems

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Design and Implementation of SCADA System Based Power Distribution for Primary Substation ( Monitoring System)

OMICRON Monitoring Solutions

How To Use A Power Supply Unit (Upu)

Georgia Tech Aerospace Server French building Server Room. Server Room Policy Handbook: Scope, Processes and Procedure

Permissible ambient temperature Operation Storage, transport

MOBILE SYSTEM FOR DIAGNOSIS OF HIGH VOLTAGE CABLES (132KV/220KV) VLF-200 HVCD

Utilizing Furukawa Optical Fiber Technology. Optical Fiber Sensing System

System integration oriented data center. planning. In terms of ATEN's eco Sensors DCIM solution

Catalog. Arc Guard System TM TVOC-2

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

Special Specification 6033 Computerized Transportation Management System

Why ClearCube Technology for Multiple Independent Secure Networks (MILS) Solutions? Client Cube KM. Moving desktops to the datacenter.

Alarm Response Management

N4385A / N4386A Distributed Temperature System (DTS)

Troubleshooting accelerometer installations

CEA LIST activity on Cable Monitoring and Diagnosis

Part 1 System Modeling & Studies for Existing Systems

Networks. The two main network types are: Peer networks

THEME Competence Matrix - Electrical Engineering/Electronics with Partial competences/ Learning outcomes

How To Test For Safety On A Power Cable

PROFINET IO Diagnostics 1

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Electrical Resistance Resistance (R)

Predictive Maintenance in a Mission Critical Environment

User s Manual AURORA 1.2K/2.2K

Wide-Area Optical Fiber Network Monitoring and Management System

Process Alarm Solutions

Cabling LANs and WANs

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

CCTV & Video Surveillance over 10G ip

How To Monitor Temperature On A Power Line

Nexus Technology Review -- Exhibit A

Web:

Leading the way in digital KVM. KVM Solutions. for Broadcast & Post Production

SMS GSM Alarm Messenger

Terminal and Dimension

TereScope Management Options

Cable Network Transparency Unified Monitoring System UMS

Online Transformer Insulation Monitoring System BushingGard Product Focus. Maximizing Transformer Uptime and Reliability

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

14. Troubleshooting Guide

Failure code manual. content

CN1047 INTRODUCTION TO COMPUTER NETWORKING CHAPTER 1 BASIC CONCEPTS OF NETWORK

Monitoring & Control of Small-scale Renewable Energy Sources

Distributed Intrusion Monitoring System With Fiber Link Backup and On-Line Fault Diagnosis Functions

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

electrical services

Understanding Network Video Security Systems

I2C PRESSURE MONITORING THROUGH USB PROTOCOL.

Video Security Systems Designer

KLQ750CO controller temp/intensity/feedback/24v/usb/rs622/analog trigger

SECTION INTEGRATED AUTOMATION SOFTWARE FOR CONTROL OF MONITORING NETWORKS

The Leading KVM Switch Solutions Provider, ATEN. 40-Port KVM Over the NET - 1 local / 4 remote user access

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Cable management for rack-mounted systems

water is cooled in a secondary cooling control tasks: use of seawater. Treatment of the seawater formation of algal vegetation.

Technologies for Data Centres

Line Monitoring and Control in Subsea Networks

Cable Condition Monitoring to Improve Reliability

Cat 5 High-Density KVM Over the NET

ISO IEC ( ) INFORMATION SECURITY AUDIT TOOL

Optical Submarine Cable Network Monitoring Equipment

Ultrasound Condition Monitoring

Max. Length of HTS Cables in the Future

The Impact of Transmission Cable System Construction and Design on Commissioning Test Options & Results

Transcription:

DTS / PDMS / Portable www.mpc2001.com

Contents DTS/CTM/DRS System PD Monitoring System Portable Diagnosis 2

DTS System DTS Principle Use the optic cable for sensor of temperaturere Sensing of temperature is able to whole route of optic fiber. Able to measure and distribute the temperature by 1 m in whole route of optic fiber DTS Operating Method Use the OTDR(Optical Time Domain Reflectometry) Principle Distance decided by multiply the time of back scattering by speed of light Determined the temperature by reflected power of the light Use the Raman scattering among the back-scattering 3

DTS / CTM / DRS System DTS/CTM/DRS DTS : Distributed Temperature Sensing CTM : Conductor Temperature Monitoring DRS : Dynamic Rating System DTS/CTM/DRS Flow chart DTS Measure the distributed temperature in whole length Hottest temperature DTS Measure the distributed Temperature CTM Calculate the conductor Temperature Input the Load Current (from CT or SCADA) CTM DRS Calculate Conductor Temperature Estimate the Dynamic Rating DRS Calculate the Dynamic Rating(Estimate) Temperature Rating DRS y 4

DTS / CTM / DRS System Diagram Function 1. Real Time Conductor Monitoring (CTM) 2. Detection of Hotspot position 3. Calculate l the Dynamic Rating (DRS) 4. Manage History of Temperature 5. Alarm History 5

DTS System Hardware Item Description Hub Connect the network between PCs and equipments Monitor Display the Client and Control the system KVM S/W Manage the DTS/Server PC using a Keyboard, a Mouse and a Monitor Keyboard/Mouse Keyboard, Mouse DTS System DTS PC - HMI(Human Interface) S/W - Display the DTS Data and Control the DTS unit Server PC Analysis and save the DTS data in Database DTS Measure the Distributed temperature UPS Uninterruptible Power Supply FDF Fiber Distribution Frame 6

DTS System Client (Example) Function 1. Main HMI : DTS System Main View (Temperature each T/L, Alarm on/off, etc.) 2. Real Time Temp : Display Temperature Real time Graph 3. Temp. Log : Search historical temperature Data 4. Trend : Display data per Hour/Day/Month 5. Setting : Set Alarm Threshold 7

PD Monitoring System PDMS? Partial Discharge Monitoring i System. Real time Monitoring and management the Partial Discharge signal in cable Principle Diagnosis i the cable by detecting ti the electronic signal in worn cable using sensor Description Accident Insulation of power cable is occurred by continuous cable Deterioration more than momentary cable Deterioration. Worn cable out -> Deterioration -> Occurrence the accident : limitation of continuous o inspection cause of steady cable Deterioration Limitation of inspection whole cable Economic loss of occurrence of cable accident Necessity of On-Line PD Monitoring PDMS System detects the symptom of power cable in advance of accident for managing the failure of system efficiently. Detect PD Monitoring Intension of prevent of decreasing cable failure Management of economic effect by Real time monitoring Automation of Monitoring Monitoring Cable Detect RealTime Signal Cable Partial Discharge Diagnosis 8

PD Monitoring System Diagram Z F HFCT Sensor Impedance HPF Filter PDU NMS PD Detection Unit Network Manage System Optic Cable(SM, 4C) PDSB Power Switch Board Power(FR-CV, 220V) PDMS RACK Z PDSB NMS PDU Z Z Z F F F F Coaxial Cable(RG-213) Local Power Cable UTP Cable(Cat. 5e) Optic Cable Main Power(220V) 9

PD Monitoring System Hardware Sensor Part Local Part Main Station Item PD Sensor Impedance HPF Filter Noise Sensor PDU NMS PDSB Hub Monitor KVM S/W Keyboard/Mouse Client PC Description Detect the abnormal signal of cable Impedance matching between sensor and equipment and protect from the serge Filter the noise from detected signal Detect the noise signal from cable outside Control the detected cable signal Communicate with Local and Master Station Power supply for Local equipment Connect the network with Server, Client PC and NMS Display the HMI and control the System Manage Client/Server PC using a Keyboard, a mouse and a monitor Keyboard, mouse - HMI(Human Interface) S/W - Control the PD equipment and display PD data Server PC NMS(Rack Type) FDF UPS Analysis the PD patterns and save the data in database - Transmit the digital data - Receive the HFPD signal from Local to Master Station Fiber Distribution Frame Uninterruptible Power Supply UPS 10

PD Monitoring System Client(Example) 1 2 3 4 5 Function 1. Main HMI : Main view On-Line PD Monitoring System 2. Event : Analysis the PD Data each channel 3. Log : Display the information of PD occurrence, user and abnormal equipment 4. Trend : Display the analysis PD data per Hour/Day/Month 5. Settings : Set the name of PD point and alarm threshold and register the administer ID/PW 11

Portable Over 154kV Cable Partial Discharge Diagnosis 154kV Partial Discharge Diagnosis Cable failure which is construction ction and design occurs the Deterioration of Insulator and causes the troubles Insulation Diagnosis for prevent the accident 154kV Partial Discharge Diagnosis Effect Prevent the failure of cable construction and design Prevent the Deterioration of Insulation by Thermal/Electrical/mechanical stress Equipment of 154kV Partial Discharge Diagnosis and Measurement General Inspection Inspection of Sheath Circulating Current and Measurement of SVL(Surge Voltage Limit)Deterioration - Judge propriety of the Sheath Circulating Current in Grounding System Between Ground and Sheath - Determine the Sheath Grouding by fault of fcable Jacket tlayer 12

Portable-Cable Partial Discharge Diagnosis (22.9kV Cable) 22.9kV Partial Discharge Diagnosis Deterioration of High voltage equipment include cable is occurred by using long period and became the cause of accident Prevent the accident by detecting the abnormal signs in order to prevent the economic loss and deterioration of reliability cause of repairing long time of the Insulation accident Effect of 22.9kV Partial Discharge Diagnosis Determine the problem of the cable insulator and joint part Periodic Diagnosis management to determine the timing to replace cable Prevent the accident of the cable insulation 22.9kV Partial Discharge Diagnosis Equipment and Measurement 13

Portable-Deterioration Phase/Panel Corona Diagnosis (under 22.9kV Cable) Deterioration Phase Diagnosis Detect the heat energy from working electronic equipment using special lens and display distributed ted temperature re of each part. Effect of Diagnosis Detection of the overload and contact inferiority of electronic equipment and etc. Prevention of Fire due to abnormal heat of electronic equipment Panel Corona Diagnosis Diagnose the corona sign of the mold-type electronic equipment which is high probability of accidents due to insulation weak using contactless equipment Diagnosis Effect Diagnose Mold-type equipment (PT, CT, ZCT etc.), Cable Head and contact point of main cable (GCB, VCB etc.) Diagnose the joint bay not able to use contact diagnosis Diagnosis Equipment and Measurement Thermo-graphic Diagnosis Thermo-Graphic Diagnosis result Panel Corona Diagnosis 14