Wide-Area Optical Fiber Network Monitoring and Management System
|
|
|
- Eric Stevens
- 10 years ago
- Views:
Transcription
1 by Kunihiro Yamamoto *, Masahide Ogawa *, Tetsuhiro Yamashita * and Masao Sasaki * The optical fiber cable networks that form the backbone of high-speed ABSTRACT communications are increasingly being laid using the vacant spaces along rivers and roads, and in sewer conduits. This requires a system that can maintain and control, efficiently, accurately and on a nation-wide scale, the changing conditions of cable installation and usage for each fiber. It is to respond to this need that we have developed a wide-area optical fiber network monitoring and management system, to provide maintenance and control of optical fiber networks. 1. INTRODUCTION The installation of optical fiber cables has proliferated with society s increased demand for telecommunications equipment, forming increasingly complex networks of lines. The areas where these are installed now cover the whole of Japan, and cables, which initially consisted of just a few optical fibers, and then a few dozen fibers each, have now reached 1000 or more fibers in each cable. This has brought massive increases in the amount of equipment. Stable operation of these growing optical fiber networks requires efficient and accurate maintenance and control of the equipment as a whole and of each individual item. There is also a need for round-the-clock monitoring of optical fiber line networks, rapid and accurate pinpointing of the location of any fault that might occur, and prompt restorative action. Accordingly at Furukawa Electric we have developed, as a means of maintaining and controlling optical fiber line networks, a monitoring and management system 1)~3) which offers a monitoring function to detect faults such as increased loss, and a management function to create a database of information pertaining to optical fiber line equipment that can be easily searched. These monitoring units and s are mainly installed in outstations, and are primarily for operations at the individual outstation level. For this reason, in a situation in which optical fiber networks are growing and expanding throughout the country, it has become necessary to investigate several outstations as a means of determining the situation in equipment that are spread over long distances, and so to configure an optical fiber * OMM System Dept., Optcom Div. network monitoring and management system on a nationwide scale. Accordingly we have developed here a wide-area optical fiber network monitoring and management system that achieves, on a nation-wide scale, a grasp of the fiber usage situation in optical fiber line equipment, connection information, system information etc. for equipment control, and monitoring of fault information. This paper provides an overview of the system thus developed. 2. SYSTEM OVERVIEW 2.1 Configuration This system comprises optical fiber line monitoring units (hereinafter referred to as monitoring units), optical fiber line s (s), optical fiber line central s (central s), and optical fiber line regional s (regional s). These units are connected by LANs or WANs. Figure 1 shows the overall system configuration, and each of the units is described as follows: (1) Monitoring units: These comprise measuring units and monitoring units installed in outstations, etc., and central monitoring units installed in block stations, etc. A monitoring unit displays the location of any fault that may occur in the optical fiber line on the system diagram etc., and transmits fault information to the central monitoring unit and s. The central monitoring unit collects monitoring results from each of the monitoring units to which it is connected, and when there is a fault, displays the fault information. (2) s: These are installed in outstations. They aggregate the results of measurements from the monitoring units, and when notice of abnormality Furukawa Review, No
2 Central station Regional Block station Block station Central monitoring unit Central Central cotrol unit Unified central monitoring/control scheme Discrete installation scheme Outstation Outstation Monitoring unit Unified monitoring/control scheme Discrete installation scheme Figure 1 Overall system configuration. information is received from a monitoring unit, pinpoint the fault location and display it on the map. They have the functions of searching, displaying and updating fiber connection information, equipment information and map information. (3) Central s: These are installed in the block stations, etc. They have the functions of searching and displaying fiber connection information, equipment information and map information under jurisdiction within block stations. They have the function of acquiring data on the manufacturers and type designations of equipment and on the names of the companies using lines that are recorded in the regional s. (4) Regional s: These are installed in the central stations, etc. They have the functions of searching and displaying fiber connection information, equipment information and map information for the whole country. They have the function of recording and updating data on the manufacturers and type designations of equipment and on the names of the companies using lines that are used in common nation-wide. 2.2 Features (1) Enables search and display of equipment i n f o r m a t i o n o n a n a t i o n - w i d e s c a l e : T h e manufacturers and type designations of equipment and the names of the companies using lines that are used in common throughout the nation are recorded as unified data in the regional s. The central s access the regional, acquire the recorded names, and then use the names at the s where input/output operation for equipment data are carried out, thereby making it possible to use names that are in common use throughout the system, and to search equipment information on a nation-wide scale. (2) Enables smooth search and display of information spanning outstations: A configuration has been adopted whereby jurisdictional equipment data under the jurisdiction of block stations are controlled in a unified manner at the control database of the central, not of each, and equipment data is not dispersed for each outstation, so that by organizing equipment data between outstations, it is possible to achieve smooth searching and display for line information spanning outstations. (3) Aggregates fault information from each outstation: Central s are installed at outstations and the fault information at each is aggregated, making it possible for fault information to be ascertained separately for each block station. 3. MONITORING UNITS 3.1 Configuration Figure 2 shows the configuration of a monitoring unit. Since the optical fiber being monitored is connected via a terminal box, each monitoring device is installed in close proximity to the terminal box. In outstations in which an operator is present, a monitoring unit is installed, and in a block station, a central monitoring unit is installed. 3.2 Functions The measuring unit uses an optical time domain reflectometer (OTDR) to make measurements sequentially and at fixed intervals with respect to optical fiber losses in the route that is targeted for monitoring, which passes through the fiber switching section and was previously designated, and by comparing the difference between the normal condition and the time at which measurement faults in the optical line are detected. T h e m o n i t o r i n g u n i t a g g r e g a t e s c o n t r o l a n d management of the measuring unit and the results of measurements taken by the measuring unit, and by previously recording the connection point information, when it receives a fault transmission from the measuring unit, quickly pinpoints the location of the fault, and Furukawa Review, No
3 Monitoring unit Central monitoring unit Operating section Monitoring unit proper Central monitoring unit proper Measuring/processing section Communication interface Communication interface Communication interface Pseudo line section Fiber switching section To Closure Immersion sensor Terminal box Terminal box Figure 2 Configuration of monitoring unit. Table 1 Main functions of monitoring units. Table 3 Minimum specifications of control uit hardware. Function Automated monitoring Fault detection and pinpointing Manual monitoring Contact point output Description Automated monitoring at specified intervals Display of information on position of fault Monitoring of any desired line by manual operation Route, unit abnormality Table 2 Main display functions of central monitoring unit. Description 1 System diagram 2 Names of equipment (block station, outstation, etc.) 3 Fault route, fault point distance, fault history Hardware item Memory CPU Hard disk CRT monitor Storage DAT device MO Application section Engine section 18 GB 12 GB* Central 100 GB 12 GB Fiber control software: Eyepack-NET Map engine: EyeKernel-X Database engine: Oracle Regional 100 GB 12 GB * Add-on Web server transmits the fault information to the central monitoring unit and the s. Table 1 shows the main functions of the monitoring units. The central monitoring unit carries out periodic monitoring of each of the monitoring units connected to it, aggregates the monitoring results, and, when there is fault information, collects the route of the fault and displays the fault information. Table 2 shows its main display functions. 4. CONTROL UNITS 4.1 Configuration Table 3 shows the specifications for each type of control unit. The central and regional s use the highly reliable RAID 5 server. DAT is provided as standard for the backup of important data. Figure 3 shows the structure of software. The operating system used is Windows NT/2000, and Furukawa Electric Information Technology s EyeKernel-X is used as the map engine. The database engine is Oracle. In this environment a newly upgraded version of Furukawa Electric Information Technology s Eyepack-NET fiber control software is used. The central and regional Operating system: Windows NT/2000 Figure 3 Structure of software. s are provided with a web function, enabling search and display from operating terminals that can be connected by LAN. 4.2 Functions The control data can, depending on its attributes, be modeled in three groups--equipment installation information, system diagram information and attribute information. Equipment installation information consists of data on line equipment installation--manholes (MH), pylons, conduits, etc. System diagram information consists of data on closures other than that which is related to geographical position, cables, and the connection conditions of each. Attribute information is information on each individual fiber and data on the condition of each connection point. Each of these levels is connected by a relational key. Using this relational key, information on the cables and closures accommodated in equipment such as Furukawa Review, No
4 Attribute information (connection point information, information on each fiber individually) System diagram information (closure information, cable information) Topographical information Planar information on installation of plant and equipment (MH, pylon, conduit, span information) Figure 5 Display to alert of occurrence of fault. Overlapping display of control data and map data Figure 4 Relational diagram of data. Table 4 Main functions of s. Function and Description Update functions Updating the equipment diagram and installations of equipment in the system diagram Updating attribute information for each item of equipment Updating fiber connection configurations for junction boxes Search & display functions Searching point of installation by means of the equipment diagram Searching & displaying line equipment by means of the equipment diagram Searching equipment passed by a specific fiber Searching circuit (route), searching dark fiber Searching junction box fiber connection configurations Searching fibers in use Searching desired conditions (search by name or specification) Searching & displaying dark fibers and routes by setting for start and end points Outputting CSV data for search results manholes or conduits can be searched at the control units, and further searching is possible, even to fiber information. And superimposing these search results and topographical map information produces an easily understood display of the conditions of line installation. Figure 4 is a relational diagram of the data, and Table 4 shows the main functions of the s. 4.3 Coordination Between Monitoring and Control Units When a line fault occurs in the line being monitored, the is notified via the monitoring unit of the fault information, together with an alarm, and a variety of information is displayed on the map by operation, including display of the location of fault occurrence. Figure 5 shows an alert screen at the time of occurrence of fault trouble. Clicking on the confirm button causes the location of the line fault to be displayed on the map (Figure 6). From the screen displaying the fault location it is possible to confirm the location of fault occurrence, the name of the conduit (between manholes) Figure 6 Display of fault location. or of the span (between pylons) containing the cable in which the fault is thought to have occurred, and the length of that conduit or span, the name of the accommodating equipment nearest the fault location (name of manhole or pylon), the distance from that location, and so on. Thus when the fault occurs in a conduit, it can immediately be ascertained how far past which manhole should be investigated, and in addition it is possible to display the waveform measured by the measuring unit, the extent of the effect when it is determined that all fibers have broken in the cable incorporating the fiber in which a fault was monitored, and to display a listing of the cables incorporating the location of the equipment incorporating the fault concerned. 4.4 Functions of Central Control Unit The central treats the central as a database server and the as a client, and operates as a client server system. In this system, in order to process the maximum amount of data, attention is paid to the response time with respect to screen displays, and when in construction, etc., data entry or updating is frequent and is dispersed or distributed, equipment data, the organizing of which is difficult, is loaded to the central and subjected to unitary management, and detailed map data, for which updating opportunities are rare and data volumes large, are loaded to the control unit, thereby improving response. Figure 7 is a conceptual diagram showing the data flow between a central control unit and a. Backup is achieved by continual replication of the control data in the central by the. Thus if there is a circuit fault or the like between the and the central rendering the control database of the central inaccessible, there is the capability of switching over to the backup data Furukawa Review, No
5 and continuing operation, so that no interference with the operations at the outstation level will occur. The central also has a search and display function with respect to the optical fiber line equipment under the jurisdiction of block stations that is similar to that of the s. It is, for example, possible to make the name of a road or river into a single key, and perform search and display for a road that runs between outstations. Figure 8 is a typical search screen. Here the equipment concerned are displayed in a listing. By clicking on the attribute buttons, equipment diagram buttons and system diagram buttons for the equipment that are to be displayed from this screen, it Central Database <Data from central to > = Equipment attribute data, topographical data, etc. When search/display is carried out at a When control data section is updated for backup at a <Data from to central > = Equipment attribute data, topographical data, etc. When data is input for the first time or updated at a due to construction, etc. of an optical fiber line is possible to display a equipment diagram on which attribute information such as the conditions of use of the fibers connected to the plant or equipment, connection information and route information, and the situation in which the equipment are installed are shown graphically on a map, and a system diagram in which the situation of cable connections are shown linearly. 4.5 Regional Control Unit Functions The regional allows the recording and updating of data on the manufacturers and type designations of equipment and on the names of the companies using lines that are used in common throughout the nation. These names are recorded at the regional control center as unified master data. From the unified master data of the regional, the central generates pseudo unified master data, and when data is entered at a, it accesses the central and selects the required data from the pseudo unified master data, so that its content is unified throughout the nation and searching on a nation-wide scale is possible. The regional control center is also able to perform search processing for line equipment nation-wide, but when the search is carried out at the regional control unit, it automatically determines the central on which the control data to be searched is loaded, and directs the server of the central to generate the required data. By receiving this control data, it is possible to perform search and display for line equipment nation-wide. Figure 7 Data flow between central and. 5. CONCLUSION The system presented here has been delivered to the Ministry of Land, Infrastructure and Transport, and has begun operation. It is intended to investigate the extent to which updated equipment data can be efficiently applied to the system, and to improve performance to respond effectively to users' needs. REFERENCES Figure 8 River name search screen. 1) Yamashita and Hasemi; Supporting System for Optical Fiber Installation Work, Furukawa Electric Review, No. 103, 1998, 13. (in Japanese) 2) Sakemi et al.; Application of GIS to Management Supporting System of Optical Fiber Transmission Line, Furukawa Electric Review, No. 107, 2001, 45. (in Japanese) 3) Umezaki and Sato; Development of Management and Supervisory System of Optical Fiber Transmission Line. (in Japanese) Furukawa Review, No
Cable Network Transparency Unified Monitoring System UMS
Cable Network Transparency Unified System UMS Fault recognition, localisation and reporting UMS Universal cable network and equipment monitoring cable networks and associated equipment used to be considered
Integration of Supervisory Control and Data Acquisition Systems Connected to Wide Area Networks
Hitachi Review Vol. 53 (2004), No. 3 169 Integration of Supervisory Control and Data Acquisition Systems Connected to Wide Area Networks Mitsuya Kato Katsufumi Watahiki Tatsuyuki Suzuki OVERVIEW: Continued
Utilizing Furukawa Optical Fiber Technology. Optical Fiber Sensing System
Utilizing Furukawa Optical Fiber Technology Optical Fiber Sensing Point Special features of optical fiber sensing s 1Reduced installation cost Sensors (measurement location) require no electrical work
Wide-area Integrated SCADA System Designed to Improve Availability and Flexibility
Hitachi Review Vol. 60 (2011), No. 7 399 Wide-area Integrated System Designed to Improve Availability and Flexibility and Operation Training Simulator System Supplied to Electric Power Development Co.,
Optical Network Management System. Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance
Optical Network Management System Remote Testing, Network Monitoring, and Service Provisioning Solution for High-Quality Network Performance JDSU Enabling Broadband and Optical Innovation Improving the
OPERATIONS CAPITAL. The Operations Capital program for the test years is divided into two categories:
Filed: September 0, 00 EB-00-0 Tab Schedule Page of OPERATIONS CAPITAL.0 INTRODUCTION Operations Capital funds enhancements and replacements to the facilities required to operate the Hydro One Transmission
OFM-500 Optical Fiber Mapping Software. A complete software application for managing documentation in fiber optic plants
OFM-500 Optical Fiber Mapping Software A complete software application for managing documentation in fiber optic plants OFM-500 Optical Fiber Mapping (OFM) Software Designed by fiber optic engineers for
Techniques for Using Time Matters in Remote Offices
Whitepaper Techniques for Using Time Matters in Remote Offices Robert Rice Rice Software Consulting, LLC www.ricesoftware.com Executive Summary Many Users of Time Matters have multiple offices either branch
ONMSi: Optical Network Monitoring System. Fiber Network Visibility that Scales for Both PON and Point-to-Point Networks
ONMSi: Optical Network Monitoring System Fiber Network Visibility that Scales for Both PON and Point-to-Point Networks y Drastically reduce network downtime y Improve network reliability and SLA management
Recent Technologies in Nuclear Power Plant Supervisory and Control Systems
Hitachi Review Vol. 49 (2000), No. 2 61 Recent Technologies in Nuclear Power Plant Supervisory and Control Systems Toshiharu Yamamori Takashi Ichikawa Satoshi Kawaguchi Hiroyuki Honma OVERVIEW: Supervisory
INSIDE. Preventing Data Loss. > Disaster Recovery Types and Categories. > Disaster Recovery Site Types. > Disaster Recovery Procedure Lists
Preventing Data Loss INSIDE > Disaster Recovery Types and Categories > Disaster Recovery Site Types > Disaster Recovery Procedure Lists > Business Continuity Plan 1 Preventing Data Loss White Paper Overview
Monitoring Underground Power Networks
Monitoring Underground Power Networks By Mark Stiles Merve Cankaya ABSTRACT Underground electric distribution systems are common in large cities throughout the United States. Power usage for the entire
AORC Technical meeting 2014
http : //www.cigre.org C4-1106 AORC Technical meeting 2014 Operational Issues and Solutions for Photovoltaic Power Generation Facilities T. KISHI, K. INOUE, T. SEKI Nishimu Electronics Industries Co.,
4G Business Continuity Solution. 4G WiFi M2M Router NTC-140W
4G Business Continuity Solution 4G WiFi M2M Router NTC-140W Introduction Whether you run a small corner shop, are the plant manager of a factory or manage IT in a corporate office, you ll need a reliable
IPv6 Broadband Access Network Systems
IPv6 Broadband Access Network Systems IPv6 Broadband Access Network Systems 60 Junji Yamada Koji Wakayama Eisuke Sato OVERVIEW: To meet the demand for broadband access and enable a smooth transition from
SECTION 16911 WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM
WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM PART 1 GENERAL 01 02 03 04 SCOPE This section describes the metering, communications, and visualization requirements for a modular, scalable Web-based Power
Convergence of Advanced Information and Control Technology in Advanced Metering Infrastructure (AMI) Solution
Convergence of Advanced Information and Control Technology in Advanced Metering Infrastructure (AMI) Solution 138 Convergence of Advanced Information and Control Technology in Advanced Metering Infrastructure
How To Use Onmsi For Fiber Optic Network Monitoring System
ONMSi: Optical Network Monitoring System Fiber network visibility that scales for both PON and point-to-point networks Drastically reduce network downtime Improve network reliability and SLA management
Integration of PRIMECLUSTER and Mission- Critical IA Server PRIMEQUEST
Integration of and Mission- Critical IA Server V Masaru Sakai (Manuscript received May 20, 2005) Information Technology (IT) systems for today s ubiquitous computing age must be able to flexibly accommodate
SMARTcontrol. Dashboard. from
SMARTcontrol from 1% Dashboard The Dashboard gives you a real time view of hardware states in an easy to read graph and gauge layout. The system allows you to show data from as far back as 48 hours. Performance
FIBER OPTIC CABLE PLANT DOCUMENTATION
C H A P T E R 13 FIBER OPTIC CABLE PLANT DOCUMENTATION JIM HAYES Documenting the fiber optic cable plant is a necessary part of the design and installation process for the fiber optic network. Documenting
920MHz Band Multi-hop Wireless Network System
920MHz Band Multi-hop Wireless Network System Hiroshi Hashizume Motohiro Inokuma Masayuki Suto Shigeru Fukunaga Motoharu Kawanishi One policy aimed at the growth of OKI Group is the development of a smart
Backup and Redundancy
Backup and Redundancy White Paper NEC s UC for Business Backup and Redundancy allow businesses to operate with confidence, providing security for themselves and their customers. When a server goes down
StreamStorage: High-throughput and Scalable Storage Technology for Streaming Data
: High-throughput and Scalable Storage Technology for Streaming Data Munenori Maeda Toshihiro Ozawa Real-time analytical processing (RTAP) of vast amounts of time-series data from sensors, server logs,
ONMSi: Optical Network Monitoring System
ONMSi: Optical Network Monitoring System Fiber network visibility that scales for both PON and point-to-point networks Drastically reduce network downtime Improve network reliability and SLA management
Lecture 1. Lecture Overview. Intro to Networking. Intro to Networking. Motivation behind Networking. Computer / Data Networks
Lecture 1 An Introduction to Networking Chapter 1, pages 1-22 Dave Novak BSAD 146, Introduction to Networking School of Business Administration University of Vermont Lecture Overview Brief introduction
Network Client. Troubleshooting Guide FREQUENTLY ASKED QUESTIONS
Network Client Troubleshooting Guide 1 Network Client Troubleshooting Guide The first section of this guide answers some frequently asked questions (FAQs) about the operation of Intellex and the Network
Data Replication INSTALATION GUIDE. Open-E Data Storage Server (DSS ) Integrated Data Replication reduces business downtime.
Open-E Data Storage Server (DSS ) Data Replication INSTALATION GUIDE Integrated Data Replication reduces business downtime. Open-E DSS Data Replication Open-E Data Server Storage (DSS) offers enterprise-class
Computer Networking Networks
Page 1 of 8 Computer Networking Networks 9.1 Local area network A local area network (LAN) is a network that connects computers and devices in a limited geographical area such as a home, school, office
Web Load Stress Testing
Web Load Stress Testing Overview A Web load stress test is a diagnostic tool that helps predict how a website will respond to various traffic levels. This test can answer critical questions such as: How
REDCENTRIC MANAGED BACKUP SERVICE SERVICE DEFINITION
REDCENTRIC MANAGED BACKUP SERVICE SERVICE DEFINITION SD003 V2.3 Issue Date 02 July 2014 1) SERVICE OVERVIEW The Managed Backup Service (MBS) is a streamlined alternative to traditional backup and restore
NETWORK MANAGEMENT SOLUTIONS
N E T S M A R T NETWORK MANAGEMENT SOLUTIONS UNIFY YOUR NETWORK As new and legacy services coexist to support a widening variety of customers, network support presents more technical challenges. This complex,
Norfolk Community Fiber Optic Network
Norfolk Community Fiber Optic Network It s not only about technology; it s also about relationships! Norfolk s Community Fiber Optic Network Norfolk s Community Fiber Optic Network Overview Connects 12
Line Monitoring and Control in Subsea Networks
Line Monitoring and Control in Subsea Networks This paper discusses how submerged equipment is monitored and contrasts different methods of doing this. It also considers what features are required by the
CA DEPT OF TECHNOLOGY NWN CALNET 3
CA DEPT OF TECHNOLOGY NWN CALNET 3 SERVICE LEVEL AGREEMENTS (SLA) Subcategory 6.1 Hosted IVR / ACD Amendment 1 Abstract The information contained within this document pertains to the Service Level Commitments
Online Vibration Monitoring
Brandon DeVier My Background 1992 B.S. Physics 3 years with Predict Technologies 13 years with DLI Engineering Online Vibration Monitoring Systems Experience Online Systems Product Manager 3 years planning,
Capacity planning for IBM Power Systems using LPAR2RRD. www.lpar2rrd.com www.stor2rrd.com
Capacity planning for IBM Power Systems using LPAR2RRD Agenda LPAR2RRD and STOR2RRD basic introduction Capacity Planning practical view CPU Capacity Planning LPAR2RRD Premium features Future STOR2RRD quick
SAN Conceptual and Design Basics
TECHNICAL NOTE VMware Infrastructure 3 SAN Conceptual and Design Basics VMware ESX Server can be used in conjunction with a SAN (storage area network), a specialized high speed network that connects computer
C20.0001 Information Systems for Managers Fall 1999
New York University, Leonard N. Stern School of Business C20.0001 Information Systems for Managers Fall 1999 Networking Fundamentals A network comprises two or more computers that have been connected in
Reducing the Risk, Cost and Frequency of Production Stoppages Using Network Redundancy
Introduction Reducing the Risk, Cost and Frequency of Production Stoppages Using Network Redundancy By Mike Miclot, Vice President of Marketing, Industrial Solutions Division at Belden and John Mower,
NETWORKING TECHNOLOGIES
NETWORKING TECHNOLOGIES (October 19, 2015) BUS3500 - Abdou Illia, Fall 2015 1 LEARNING GOALS Identify the major hardware components in networks. Identify and explain the various types of computer networks.
MAP/100P RAID System Recovery. MAP/100P RAID System Recovery - 1
MAP/100P RAID System Recovery MAP/100P RAID System Recovery - 1 Issue 2 FAN FAULT DISK ACTIVITY 0 1 2 3 4 5 FAN FAULT POWER ON P/S FAULT FAN FAULT MAINTENANCE USE ONLY LATCH RELEASE GB RESET mpixf10p LJK
Agenda. Capacity Planning practical view CPU Capacity Planning LPAR2RRD LPAR2RRD. Discussion. Premium features Future
Agenda Capacity Planning practical view CPU Capacity Planning LPAR2RRD LPAR2RRD Premium features Future Discussion What is that? Does that save money? If so then how? Have you already have an IT capacity
Chapter 6 Essentials of Design and the Design Activities
Systems Analysis and Design in a Changing World, sixth edition 6-1 Chapter 6 Essentials of Design and the Design Activities Chapter Overview There are two major themes in this chapter. The first major
Mitel MiVoice Enterprise Manager
Mitel MiVoice Enterprise Manager Results Driven Network Management Minimize your Mitel IP network system Minimize your system administration and maintenance costs by provisioning multiple Mitel sites and
Backup Exec 9.1 for Windows Servers. SAN Shared Storage Option
WHITE PAPER Optimized Performance for SAN Environments Backup Exec 9.1 for Windows Servers SAN Shared Storage Option 11/20/2003 1 TABLE OF CONTENTS Executive Summary...3 Product Highlights...3 Approaches
Chapter 6 Using Network Monitoring Tools
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your Wireless-G Router Model WGR614v9. You can access these features by selecting the items under
General LAN Guidelines and Sign off process as mentioned in the Tender Document for High Court Coordinator
General LAN Guidelines and Sign off process as mentioned in the Tender Document for High Court Coordinator Survey and Document preparation Agencies employed for providing LAN System Integration Services
Schools and Libraries Universal Service Support Mechanism Eligible Services List
Schools and Libraries Universal Service Support Mechanism Eligible Services List (WC Docket No. 13-184; CC Docket No. 02-6; GN Docket No. 09-51) The Federal Communications Commission s (FCC s) rules provide
See all, manage all is the new mantra at the corporate workplace today.
See all, manage all is the new mantra at the corporate workplace today. 1) Do you want to schedule backups, software updates using just one consistent automation platform? 2) Do you want a product that
REMOTE MONITORING AND CONTROL OF THE KAKKONDA GEOTHERMAL POWER PLANTS
REMOTE MONITORING AND CONTROL OF THE KAKKONDA GEOTHERMAL POWER PLANTS Shinji Nishikawa 1, Toshiyuki Takahashi 1, Takeshi Koi 1, and Katsuyoshi Yamada 2 1 Toshiba Corporation Power Systems & Services Company,
System Infrastructure Non-Functional Requirements Related Item List
System Infrastructure Non-Functional Requirements Related Item List April 2013 Information-Technology Promotion Agency, Japan Software Engineering Center Copyright 2010 IPA [Usage conditions] 1. The copyright
Volume Replication INSTALATION GUIDE. Open-E Data Storage Server (DSS )
Open-E Data Storage Server (DSS ) Volume Replication INSTALATION GUIDE Enterprise-class Volume Replication helps ensure non-stop access to critical business data. Open-E DSS Volume Replication Open-E Data
Recent Trends of Storage System Technologies
Recent Trends of Storage System Technologies Recent Trends of Storage System Technologies 92 Yasutomo Yamamoto Yasunori Kaneda Masahide Sato OVERVIEW: In conventional systems, data is distributed among
Network and Facility Management: Needs, Challenges and Solutions
Network and Facility Management: Needs, Challenges and Solutions Graham Jones Harris Broadcast Communications [email protected] New tools are needed to enable broadcasters to efficiently manage the modern
ALTIRIS Package Server
ALTIRIS Package Server The information contained in the Altiris knowledgebase is subject to the Terms of Use as outlined at http://www.altiris.com/legal/termsofuse.asp. History Additions / Edits Date 1st
Sample of Hardware Equipment Acceptance Form
Sample of Hardware Equipment Acceptance Form Acceptance Plan: (File Server) (Form P1) Server System Unit Item & Serial No. : Result : Pass / Fail Power-On Self (POST) to be conducted Power on the server
Service Descriptions
Mainframe Application Hosting/Central Processing Unit (CPU) Rate: $1,044.00 per hour (Based on normalization to an IBM 2064-116 model rated at 8,117.7067 SUs per second) The DTS provides software application
Server Management Agent for Windows User s Guide. Server Management 2.0 and Higher
Server Management Agent for Windows User s Guide Server Management 2.0 and Higher March 2008 . unisys imagine it. done. Server Management Agent for Windows User s Guide Server Management 2.0 and Higher
MANAGEMENT INFORMATION SYSTEMS 8/E
MANAGEMENT INFORMATION SYSTEMS 8/E Raymond McLeod, Jr. and George Schell Chapter 10 Data Communications Copyright 2001 Prentice-Hall, Inc. 10-1 Objectives Understand data communication basics. Know the
White Paper. NEC Invariant Analyzer with Oracle Enterprise Manager
NEC Invariant Analyzer with Oracle Enterprise Manager Table of Contents Introduction... 3 Proactive Performance Analysis... 3 Overview of Oracle Enterprise Manager... 4 Oracle Enterprise Manager Cloud
FUNCTIONAL AREA 12. Network Administration (NET)
FUNCTIONAL AREA 12 Network Administration (NET) Incumbents in this functional area address interoperability issues related to hardware, software, and connectivity of communications such as cable, fiber
Layer 3 Network + Dedicated Internet Connectivity
Layer 3 Network + Dedicated Internet Connectivity Client: One of the IT Departments in a Northern State Customer's requirement: The customer wanted to establish CAN connectivity (Campus Area Network) for
MFR IT Technical Guides
MFR IT Technical Guides Windows 7 Backup and Recovery Page 1 of 33 Table of Contents 1 Glossary... 3 2 Backup Strategy... 4 3 Windows Backup Options... 5 3.1 Windows Backup... 5 3.2 Windows System Image
SERVICE SCHEDULE MANAGED HOSTED APPLICATIONS
SERVICE SCHEDULE MANAGED HOSTED APPLICATIONS This is a Service Schedule as defined in the Conditions. Where the Services set out in this Service Schedule form part of the Services to be supplied under
Chapter 6 Using Network Monitoring Tools
Chapter 6 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax Wireless-N Gigabit Router WNR3500. You can access these features by selecting the items
IGNITE Cloud Server enhancements
IGNITE Cloud Server enhancements Current Cloud Server product 2 Current Cloud Server product We currently have 4 Cloud Server packages 3 Current Cloud Server product: signup page With the current package
EMC CENTERA VIRTUAL ARCHIVE
White Paper EMC CENTERA VIRTUAL ARCHIVE Planning and Configuration Guide Abstract This white paper provides best practices for using EMC Centera Virtual Archive in a customer environment. The guide starts
WIDESTAR II Base Station Maintenance and Monitoring System
WIDESTAR II Base Station Maintenance and Monitoring System Web Browser Conversion Occupied Band Service System Switching Control Special Articles on WIDESTAR II High-speed Mobile Satellite Communications
WEB SERVER MONITORING SORIN POPA
WEB SERVER MONITORING SORIN POPA Keywords: monitoring systems, web server, monitoring process Sorin POPA, Associate Professor, PhD. University of Craiova Abstract. This paper introduces web-server monitoring,
CF Dashboard Offering
M-Applications Manual 653 CF Dashboard Section Issue Date 0601 APPLICATION NOTE CF Dashboard Offering Creating the CF Dashboard Offering...3 Introduction... 3 Key Concepts... 4 CF Dashboard Offering...4
PLCs and SCADA Systems
Hands-On Programmable Logic Controllers and Supervisory Control / Data Acquisition Course Description This extensive course covers the essentials of SCADA and PLC systems, which are often used in close
GIS-Based Remote Monitoring System for Traffic Lights, Footbridge Lifts and Escalators in Hong Kong
GIS-Based Remote Monitoring System for Traffic Lights, Footbridge Lifts and Escalators in Hong Kong Ir CHIANG, King Wah CHAN, Enoch LEUNG, Wai Tung Project Division, EMSD Project Division, EMSD Project
Oracle Maps Cloud Service Enterprise Hosting and Delivery Policies Effective Date: October 1, 2015 Version 1.0
Oracle Maps Cloud Service Enterprise Hosting and Delivery Policies Effective Date: October 1, 2015 Version 1.0 Unless otherwise stated, these Oracle Maps Cloud Service Enterprise Hosting and Delivery Policies
Core Syllabus. Version 2.6 C OPERATE KNOWLEDGE AREA: OPERATION AND SUPPORT OF INFORMATION SYSTEMS. June 2006
Core Syllabus C OPERATE KNOWLEDGE AREA: OPERATION AND SUPPORT OF INFORMATION SYSTEMS Version 2.6 June 2006 EUCIP CORE Version 2.6 Syllabus. The following is the Syllabus for EUCIP CORE Version 2.6, which
SCADA and Monitoring for Solar Energy Plant
SCADA and Monitoring for Solar Energy Plant Segment: Industry Country: Thailand Author: Ranon Satitpanyapan Products: NI LabVIEW with LabVIEW Real-Time Module crio Real-Time controller 8 slot with 16 current
NETFORT LANGUARDIAN MONITORING WAN CONNECTIONS. How to monitor WAN connections with NetFort LANGuardian Aisling Brennan
NETFORT LANGUARDIAN MONITORING WAN CONNECTIONS How to monitor WAN connections with NetFort LANGuardian Aisling Brennan LANGuardian gives you the information you need to troubleshoot problems and monitor
Network Attached Storage. Jinfeng Yang Oct/19/2015
Network Attached Storage Jinfeng Yang Oct/19/2015 Outline Part A 1. What is the Network Attached Storage (NAS)? 2. What are the applications of NAS? 3. The benefits of NAS. 4. NAS s performance (Reliability
3 Software Defined Radio Technologies
3 Software Defined Radio Technologies 3-1 Software Defined Radio for Next Generation Seamless Mobile Communication Systems In this paper, the configuration of the newly developed small-size software defined
Local-Area Network -LAN
Computer Networks A group of two or more computer systems linked together. There are many [types] of computer networks: Peer To Peer (workgroups) The computers are connected by a network, however, there
Cable Network Transparency Fiber Optic Monitoring
Cable Network Transparency Fiber Optic Monitoring Fault recognition, localisation and reporting Fiber Optic Cable Future of Telecommunication The demand for complex fiber optic cable networks and flexible
Load Manager Administrator s Guide For other guides in this document set, go to the Document Center
Load Manager Administrator s Guide For other guides in this document set, go to the Document Center Load Manager for Citrix Presentation Server Citrix Presentation Server 4.5 for Windows Citrix Access
Imaging Computing Server User Guide
Imaging Computing Server User Guide PerkinElmer, Viscount Centre II, University of Warwick Science Park, Millburn Hill Road, Coventry, CV4 7HS T +44 (0) 24 7669 2229 F +44 (0) 24 7669 0091 E [email protected]
How To Check If Your Router Is Working Properly On A Nr854T Router (Wnr854) On A Pc Or Mac) On Your Computer Or Ipad (Netbook) On An Ipad Or Ipa (Networking
Chapter 7 Using Network Monitoring Tools This chapter describes how to use the maintenance features of your RangeMax NEXT Wireless Router WNR854T. These features can be found by clicking on the Maintenance
- 1 - SmartStor Cloud Web Admin Manual
- 1 - SmartStor Cloud Web Admin Manual Administrator Full language manuals are available in product disc or website. The SmartStor Cloud Administrator web site is used to control, setup, monitor, and manage
Updating the International Standard Classification of Occupations (ISCO) Draft ISCO-08 Group Definitions: Occupations in ICT
InternationalLabourOrganization OrganisationinternationaleduTravail OrganizaciónInternacionaldelTrabajo Updating the International Standard Classification of Occupations (ISCO) Draft ISCO-08 Group Definitions:
Optimizing Large Arrays with StoneFly Storage Concentrators
Optimizing Large Arrays with StoneFly Storage Concentrators All trademark names are the property of their respective companies. This publication contains opinions of which are subject to change from time
