High performance thin layer chromatographic method for estimation of deflazacort in tablet



Similar documents
HIGH PERFORMANCE THIN LAYER CHROMATOGRAPHIC METHOD FOR DETERMINATION OF TADALAFIL IN TABLET DOSAGE FORM

High Performance Thin Layer Chromatographic Method for Estimation of Cefprozil in Tablet Dosage Form

HIGH PERFORMANCE THIN LAYER CHROMATOGRAPHIC METHOD FOR DETERMINATION OF VALGACYCLOVIR IN TABLET DOSAGE FORM

INTERNATIONAL JOURNAL OF PHARMACEUTICAL RESEARCH AND BIO-SCIENCE

Development of validated RP- HPLC method for estimation of rivaroxaban in pharmaceutical formulation

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Stability-indicating High Performance Thin Layer Chromatographic Determination of Clozapine in Tablet Dosage Form

ORIENTAL JOURNAL OF CHEMISTRY An International Open Free Access, Peer Reviewed Research Journal.

SUCRALOSE. White to off-white, practically odourless crystalline powder

UV-VIS SPECTROPHOTOMETRIC METHOD FOR ESTIMATION OF GABAPENTIN AND METHYLCOBALAMIN IN BULK AND TABLET

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

PVV Satyanaryana et al., IJSID, 2012, 2 (1), International Journal of Science Innovations and Discoveries

Simultaneous Determination of Paracetamol, Lornoxicam and Chlorzoxazone in Tablets by High Performance Thin Layer Chromatography

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Guidance for Industry

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Journal of Chemical and Pharmaceutical Research, 2012, 4(7): Research Article

DETERMINATION OF SALICYLAMIDE IN PHARMACEUTICAL TABLETS BY HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHY WITH ULTRAVIOLET ABSORPTION DENSITOMETRY

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA PARACETAMOL ORAL SUSPENSION (September 2010)

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Hiral N. Davea, Ashlesha G. Makwanab,*, and Bhanubhai N. Suhagiac

By T.Sudha, T.Raghupathi

A NEW METHOD DEVELOPMENT AND VALIDATION FOR ANALYSIS OF RIVAROXABAN IN FORMULATION BY RP HPLC

Standard Analytical Methods of Bioactive Metabolitesfrom Lonicera japonica Flower Buds by HPLC-DAD and HPLC-MS/MS

International Journal of Pharma and Bio Sciences V1(2)2010

UV Spectrophotometric estimation of Paracetamol and Lornoxicam in Bulk drug and Tablet dosage form using Multiwavelength

International Journal of Research and Reviews in Pharmacy and Applied science.

Office Chromatography

Journal of Chemical and Pharmaceutical Research

All the prepared formulations were subjected for following. evaluation parameters and obtained results were showed in Tables 6.3 &

Extraction of Epinephrine, Norepinephrine and Dopamine from Human Plasma Using EVOLUTE EXPRESS WCX Prior to LC-MS/MS Analysis

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Analytical Test Report

GUIDELINES FOR THE VALIDATION OF ANALYTICAL METHODS FOR ACTIVE CONSTITUENT, AGRICULTURAL AND VETERINARY CHEMICAL PRODUCTS.

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Chemistry 321, Experiment 8: Quantitation of caffeine from a beverage using gas chromatography

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

Liquid Chromatographic Method for the estimation of Donepezil Hydrochloride in a Pharmaceutical Formulation

LIQUID CHROMATOGRAPHY HOW MUCH ASPIRIN, ACETAMINOPHEN, AND CAFFEINE ARE IN YOUR PAIN RELIEVER? USING HPLC TO QUANTITATE SUBSTANCES (Revised: )

SPE, LC-MS/MS Method for the Determination of Ethinyl Estradiol from Human Plasma

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

A commitment to quality and continuous improvement

Overview. Triple quadrupole (MS/MS) systems provide in comparison to single quadrupole (MS) systems: Introduction

A practical and novel standard addition strategy to screen. pharmacodynamic components in traditional Chinese medicine using

A RAPID TLC METHOD FOR ANALYSIS OF EXTERNAL FLAVONOID AGLYCONES IN PLANT EXUDATES

Determination of Tricyclazole in Water Using Solid Phase Extraction and Liquid Chromatography

VALIDATION OF HPLC METHOD FOR DETERMINATION OF DOCOSAHEXAENOIC ACID (DHA) IN MULIIVITAMIN CAPSULE DIAH WIDOWATI*, ROS SUMARNY, ESTI MUMPUNI

Transfer of a USP method for prednisolone from normal phase HPLC to SFC using the Agilent 1260 Infinity Hybrid SFC/UHPLC System Saving time and costs

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

Research Article. Stress study and estimation of a potent anticoagulant drug rivaroxaban by a validated HPLC method: Technology transfer to UPLC

Tamsulosin Hydrochloride Capsules

Analytical Method Development and Validation of Caffeine in Tablet Dosage Form By Using UV- Spectroscopy

DEVELOPMENT AND VALIDATION OF A STABILITY INDICATING HPLC METHOD FOR ANALYSIS OF PEFLOXACIN IN BULK DRUG AND TABLET DOSAGE FORM

Scholars Research Library. A validated RP-HPLC method for estimation of Rivastigmine in pharmaceutical formulations

Daniel M. Mueller, Katharina M. Rentsch Institut für Klinische Chemie, Universitätsspital Zürich, CH-8091 Zürich, Schweiz

Development and validation of a dissolution test for Candesartan cilexetil in tablet forms using reverse phase High performance liquid chromatography

ICH Topic Q 2 (R1) Validation of Analytical Procedures: Text and Methodology. Step 5

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

Research Article. Development and validation of a HPLC analytical assay method for dapoxetine tablets: A medicine for premature ejaculation

Spectrophotometric Determination And Validation Of Acyclovir In Tablet Dosage Form

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

# LCMS-35 esquire series. Application of LC/APCI Ion Trap Tandem Mass Spectrometry for the Multiresidue Analysis of Pesticides in Water

Overview. Purpose. Methods. Results

Development and validation of UV spectrophotometric method for the determination of rivaroxaban

LC-MS/MS for Chromatographers

ERDOSTEINE - MONOGRAPH.

Quantitative analysis of anabolic steroids in control samples from food-producing animals using a column-switching LC-HESI-MS/MS assay

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Received: 19 Jun2010, Revised and Accepted: 20 July 2010

A High Throughput Automated Sample Preparation and Analysis Workflow for Comprehensive Forensic Toxicology Screening using LC/MS/MS

Therapeutic Drug Monitoring of Antiretroviral Drugs with HPLC-MS

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

SIMULTANEOUS ESTIMATION OF NABUMETONE AND PARACETAMOL BY VIERODT S METHOD IN COMBINED TABLET DOSAGE FORM

Venkata S Rao Somisetty 1 *, D Dhachinamoorthi 1, S A Rahaman 2, CH M M Prasada Rao 1

Simultaneous estimation of lansoprazole and naproxen by using UV spectrophotometer in tablet dosage form

OREGON GRAPE FOR HOMOEOPATHIC PREPARATIONS BERBERIS AQUIFOLIUM FOR HOMOEOPATHIC PREPARATIONS

INTERNATIONAL OLIVE COUNCIL

Development and Validation of RP-HPLC Method for the determination of Methylphenidate Hydrochloride in API

Analysis of Various Vitamins in Multivitamin Tablets

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

Analysis of the Vitamin B Complex in Infant Formula Samples by LC-MS/MS

Journal of Chemical and Pharmaceutical Research

Sex Hormone Testing by Mass Spectrometry

Planar Chromatography

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Vitamin C quantification using reversed-phase ion-pairing HPLC

HS 1003 Part 2 HS 1003 Heavy Metals Test

IN VITRO BINDING BIOEQUIVALENCE STUDY SUMMARY TABLES AND SAS TRANSPORT FORMATTED TABLES FOR DATASET SUBMISSION

Analytical Test Method Validation Report Template

Transcription:

ISSN: 2231-3354 Received on: 07-09-2011 Revised on: 11-09-2011 Accepted on: 13-09-2011 High performance thin layer chromatographic method for estimation of deflazacort in tablet Patel Satish A and Patel Natvarlal J. ABSTRACT Patel Satish A and Patel Natvarlal J. Department of Pharmaceutical Quality Assurance, Shree S. K. Patel College of Pharmaceutical Education & Research, Ganpat University, Kherva 382711, Mehsana, Gujarat, India. A simple and sensitive high performance thin layer chromatography (HPTLC) method has been developed for the quantitative estimation of deflazacort in its single component tablet formulation (30 mg). Deflazacort was chromatographed on silica gel 60 F 254 TLC plate using benzene: methanol: glacial acetic acid (7.5:2.0:0.5, v/v/v) as mobile phase. Deflazacort showed Rf value of 0.60 + 0.02 and scanned at 243 nm using a camag TLC scanner 3. The method was validated in terms of linearity (100 800 ng/spot), precision (intra-day variation, 0.335 to 1.203% and inter-day variation, 0.231 to 1.471%), accuracy (98.87 to 99.77%) and specificity. The limit of detection and limit of quantification for deflazacort were found to be 25.97 ng/spot and 85.70 ng/spot, respectively. The developed method was successfully used for the assay of deflazacort tablet formulation. The method was found to be simple, sensitive, specific, accurate and precise and can be used for the routine quality control testing of deflazacort in tablet dosage form. Key words: Deflazacort, HPTLC, validation, tablet. INTRODUCTION For Correspondence: Patel Satish A, Department of Pharmaceutical Quality Assurance, Shree S. K. Patel College of Pharmaceutical Education & Research, Ganpat University, Kherva 382711, Mehsana, Gujarat, India. Phone & Fax No.: +91-2762-286082 The deflazacort is chemically (11β,16β)-21-(acetyloxy)-11-hydroxy-2 -methyl-5 Hpregna-1,4-dieno[17,16-d]oxazole-3,20-dione (Maryadele et al., 2006) is a glucocorticoid used as an anti-inflammatory and immunosuppressant (Sweetman et al., 2007). Deflazacort is not official in any pharmacopoeias; hence official method is not available for determination of deflazacort. Literature survey reveals different liquid chromatographic method like reverse-phase HPLC method for estimation of deflazacort in pharmaceutical preparations (Cardoso et al., 2007), extractive HPLC method for deflazacort and its metabolite 21-hydroxydeflazacort (Santos-Montes et al., 1994), HPLC method for natural and synthetic corticosteroids (Santos-Montes et al., 1993), micellar liquid chromatography using sodium dodecyl sulphate for estimation of deflazacort in urine (Santos-Montes et al., 1999), RP-HPLC for dissolution studies and determination of deflazacort in pharmaceutical formulations and human serum samples (Ozkan et al., 2003), reversed-phase HPLC for corticoid alcohols and their derivatives (Gonzalo-Lumbreras et al., 1997), liquid chromatography-mass spectrometry method for determination of 21- hydroxydeflazacort in human plasma (LC/MS) (Ifa et al., 2000) and LC-MS/MS method based on class-characteristic fragmentation pathways for the detection of synthetic glucocorticosteroids in human urine (Mazzarino et al., 2008) for estimation of deflazacort. Literature survey does not reveal any simple HPTLC method for determination of deflazacort in tablet formulation. The present manuscript describes simple, sensitive, accurate, precise and specific HPTLC procedure for the determination of deflazacort in pharmaceutical tablet dosage forms.

MATERIALS AND METHODS Apparatus A Camag HPTLC system (Switzerland) comprising of Camag Linomat V semiautomatic sample applicator, Camag TLC Scanner 3, Camag (Muttenz, Switzerland) flat bottom and twintrough developing chamber (10 10 cm), UV cabinet with dual wavelength UV lamp, Camag wincats software, Hamilton syringe (100 µl), Sartorius CP224S analytical balance (Germany), Ultrasonic bath (Frontline FS-4, Mumbai, India) were used in the study. Reagents and Materials Deflazacort was kindly supplied by Zydus Cadila Healthcare, Changodar, India as a gift sample. The commercially available tablets of deflazacort were procured from local market labeled to contain 30 mg deflazacort. Silica Gel 60 F 254 TLC plates (10 10 cm, layer thickness 0.2 mm, E. Merck, Germany) were used as stationary phase. Chloroform, toluene, benzene (AR grade, S.D. Fine Chemicals Ltd, Mumbai, India), methanol and glacial acetic acid (AR grade, Finar Chemicals Ltd, Ahmedabad, India) were used for mobile phase preparation and as solvents. Preparation of standard solution Deflazacort reference standard (100 mg) was accurately weighed and transferred into 100 ml volumetric flask. Methanol (50 ml) used as diluent was added and shake well until it dissolved. Volume was made up to mark with methanol and mixed (1 mg/ml). Deflazacort working standard solution was prepared by diluting standard stock solution (5.0 ml) to 50 ml with diluent to produce required concentration (100 g/ml). Preparation of sample solution Twenty tablets were weighed and powdered. The quantity of the powder (equivalent to 10 mg of Deflazacort) was transferred to a 100 ml volumetric flask, sonicated for 30 minutes with methanol (50 ml) to dissolve the drug as completely as possible. The solution was filtered into a 100 ml volumetric flask through a Whatman filter paper No. 41. The residue was washed with diluent (20 ml), and washes were added to the 100 ml volumetric flask. The solution was diluted up to 100 ml with methanol (100 g/ml). Two microlitres of this solution was applied to the HPTLC plate to get 200 ng/spot and followed by development. Chromatographic conditions The chromatographic estimations were performed using following condition; stationary phase, precoated Silica Gel 60 F 254 aluminum sheets (10 10 cm) (pre-washed with methanol and dried in air); mobile phase, benzene: methanol: glacial acetic acid (7.5:2.0:0.5, v/v/v); chamber saturation time, 30 min; temperature, 25 ± 2 o, migration distance, 80 mm; wavelength of detection, 243 nm; slit dimensions, 5 0.45 mm; scanning speed, 10 mm/s. Following spotting parameter were used - band width, 6 mm; distance from the plate edge, 10 mm; space between two bands, 10 mm and spraying rate, 1 µl/s. Chromatographic separation Five microlitres of standard solution of deflazacort (100 µg/ml) was applied on TLC plate under nitrogen stream using semiautomatic spotter. The plate was dried in air and developed up to 80 mm at constant temperature using mixture of benzene: methanol: glacial acetic acid (7.5:2.0:0.5, v/v/v) as mobile phase in Camag twin-trough chamber previously saturated with mobile phase for 30 min. The plate was removed from the chamber and dried in air. Photometric measurements were performed at 243 nm in absorbance/reflectance mode with Camag TLC Scanner 3 using wincats software incorporating the track optimization option. Validation of the proposed method The proposed method is validated according to the International Conference on Harmonization (ICH) guidelines. Linearity (Calibration curve) Aliquots of 1.0, 2.0, 3.0, 4.0, 5.0, 6.0, 7.0 and 8.0 l of standard deflazacort solution (100 µg/ml) were spotted on precoated TLC plate using semiautomatic spotter under nitrogen stream. The TLC plate was developed and photometrically analyzed as described under chromatographic separation. Each concentration was spotted five times on the TLC plate. The calibration curve was prepared by plotting peak area versus concentration (ng/spot) corresponding to each spot. Accuracy (% Recovery) The accuracy of the method was determined by calculating recoveries of deflazacort by the standard addition method. Known amounts of standard solutions of Deflazacort were added at 50%, 100% and 150% levels to prequantified 200 ng/spot standard solutions of deflazacort. The amount of deflazacort was estimated by applying the obtained values to the regression equation of the calibration curve. Method Precision (% Repeatability) The precision of the instruments was checked by repeated spotting of same solution and repeated scanning of the same spot (n=6) of deflazacort without changing the position of plate for the HPTLC method. The repeatability was reported in terms of relative standard deviation (% RSD). Intermediate Precision (Reproducibility) The intraday and interday precisions of the proposed methods were determined by estimating the corresponding responses 3 times on the same day and on 3 different days over a period of one week for 3 different concentration of standard solution of deflazacort (200, 400 and 600 ng/spot) for the proposed method. The results were reported in terms of relative standard deviation (% RSD). Limit of detection (LOD) and limit of quantification (LOQ) LOD and the LOQ of the drug were calculated using the following equations as per International Conference on Harmonization (ICH) guidelines.

LOD = 3.3 /S LOQ = 10 /S Where = Standard deviation of the response S = Slope of calibration curve Specificity The specificity of the method was ascertained by analyzing standard drugs and the sample. The spots for deflazacort in the samples were confirmed by comparing the R f and spectra of the spots with that of the standards. Analysis of deflazacort in tablet Five microlitres of sample solution was applied to the TLC plate to get 500 ng/spot and followed by development and scanning as described earlier. Analysis was carried out in triplicate, peak areas were measured at 243 nm and sample concentrations calculated. The amount of deflazacort present in the sample solution was determined by fitting area values of peak corresponding to deflazacort into the equation of line representing calibration curve of deflazacort. The potential interference from excipients was also examined. RESULTS AND DISCUSSION Deflazacort is soluble in methanol; therefore methanol was selected as solvent. Several mobile phases were tried to accomplish good separation of deflazacort. Using the mobile phase benzene: methanol: glacial acetic acid (7.5:2.0:0.5, v/v/v) and 10 10 cm silica gel 60F 254 aluminum-backed plates, good separation was attained with retardation factor (R f ) values of 0.60 + 0.02 for deflazacort (Figure 1 and 2). Fig. 2: 3-D Chromatogram showing peaks of deflazacort in different concentrations at 243 nm 0.9994. The average linear regression equation was represented as y = 3.5211x+89.893, where x = concentration of deflazacort in ng/spot and y = peak area. The limit of detection and limit of quantification for deflazacort were found to be 25.97 ng/spot and 85.70 ng/spot, respectively indicate sensitivity of the method. The intra-day precision (%RSD) was calculated for standard deflazacort solutions (200, 400 and 600 ng/spot) for 3 times on the same day. The inter-day precision (% RSD) was calculated for standard deflazacort solutions (200, 400 and 600 ng/spot) for 3 times over a period of one week. The intra-day and inter-day variation (% RSD) were found to be in the range of 0.335 to 1.203 and 0.231 to 1.471, respectively. These values indicate that the method is precise. Precision of the instrument was checked by repeated scanning of the same spot (200 ng/spot) of deflazacort six times without changing position of the plate and % RSD for measurement of peak area was found to be 0.81. The % RSD for measurement of peak area ensures proper functioning of HPTLC system indicates repeatability of the proposed method. Different validation parameters for the proposed HPTLC method for determining deflazacort content are summarized in Table 1. Fig. 1: HPTLC chromatogram of deflazacort with corresponding Rf value at 243 nm. A wavelength of 243 nm was used for quantification of the drug. Even saturation of TLC chamber with mobile phase for 30 min assured better reproducibility and better resolution. Linearity range for deflazacort was found in the concentration range of 100 to 800 ng/spot, with a correlation coefficient of Table 1: Regression analysis data and summary of validation parameters for the proposed HPTLC method Parameters Results Linearity range (ng/spot) 10-800 Regression Equation (y = mx + c) y = 3.5211x + 89.893 Slope 3.5211 Intercept 89.893 Correlation co-efficient (r 2 ) 0.9994 Precision (% RSD) Intra-day (n = 3) Inter-day (n = 3) 0.335-1.203 0.231-1.471 Repeatability of peak area (% RSD) 0.81 (n = 6) Accuracy (% Recovery) (n = 3) 99.39 + 0.46 Limit of detection (LOD) (ng/spot) 25.97 Limit of quantification (LOQ) 85.70 (ng/spot) Specificity Specific n is number of determination and RSD is relative standard deviation.

Table 2: Recovery data for the proposed method. Drug Level Amount of sample taken (ng/spot) Amount of standard spiked (%) % Recovery 99.55 I 200 50 % 100.7 98.33 100.5 Deflazacort II 200 100 % 99.58 99.18 99.40 III 200 150% 98.85 98.37 n is number of determination and S. D. is standard deviation. Mean % recovery ± S. D. * 99.52 ± 1.17 99.77 ± 0.71 98.87 ± 0.52 Accuracy of the method was evaluated by calculating recovery of deflazacort by standard addition method at 3 different levels of the calibration curve (n = 5). The mean recovery was found to be 99.39 + 0.46% ensuring that the method is accurate (Table 2). The method was found to be specific for deflazacort. The specificity of the method was ascertained by analyzing standard drug and the samples. The spot for deflazacort in the sample was confirmed by comparing the Rf value and spectra of the spot with that of standard. The peak purity of deflazacort was assessed by comparing the spectra of standard at peak start, peak apex and peak end positions of spot. Good correlation was also found between standards and sample spectra (Figure 3). None of the formulation excipients were interferes in the quantification of deflazacort at this Rf value. Table 3: Analysis of tablet formulation of deflazacort by proposed HPTLC method (n = 6) Tablet Label claim (mg) Parameters % amount found (n = 6) HPTLC method Brand A 30 Mean 99.54 S. D. 0.26 Brand Mean 99.10 30 B S. D. 0.51 n is number of determination and S. D. is standard deviation. CONCLUSION The results of the analysis of pharmaceutical formulation by the proposed method are highly reproducible and reliable and are in good agreement with the label claim of the drug. The additives usually present in the pharmaceutical formulations of the assayed samples did not interfere with determination of deflazacort. The observations and results obtained from this study, including specificity, linearity and range, accuracy, precision (method precision as repeatability and intermediate precision as intra and inter day precision) are lie well within acceptable results. From the experimental studies it can be concluded that proposed method can be adopted for the routine analysis of deflazacort in tablets without interference of excipients. ACKNOWLEDGEMENT The author is thankful to Zydus Cadila Healthcare, Changodar, India for providing the gift sample of deflazacort and Shree S. K. Patel College of Pharmaceutical Education and Research, Ganpat University for providing all the facilities to carry out the research work. REFERENCES Fig. 3: Overlain UV absorption spectrum of standard and sample deflazacort. This method was applied to determine the content of deflazacort in market sample of single component deflazacort tablet. The average percentage of deflazacort in market sample was found to be 99.54 + 0.26 % for tablet brand 1 and 99.10 + 0.51 % for tablet brand 2 (n = 6). The results are in agreement with the labeled value of deflazacort in tablet dosage form (Table 3). The results indicate that the proposed HPTLC method was found to be simple, sensitive, specific, precise and accurate for the estimation of deflazacort in tablet formulations. Cardoso S. Development and validation of a reversed-phase HPLC method for the determination of deflazacort in pharmaceutical dosage forms. Chromatographia. 2007; 65: 591-594. Gonzalo-Lumbreras R., Santos-Montes A., Garcia-moreno E., Izquierdo-Hornillos R. High-performance liquid chromatographic separation of corticoid alcohols and their derivatives: a hydrolysis study including application to pharmaceuticals. J Chromatogr Sci. 1997; 35: 439-445. Ifa D., Moraes M., Santagada V., Caliendo G., De Nucci G. Determination of 21-hydroxydeflazacort in human plasma by highperformance liquid chromatography/ atmospheric pressure chemical ionization tandem mass spectrometry: Application to bioequivalence study. J Mass Spectrom. 2000; 35: 440-445. Maryadele JO Neil. The Merck Index: An Encyclopedia of chemicals, drugs and biologicals. 14th ed. Merck Research Laboratories, Merck and Co., Inc, Whitehouse station, New Jersey (2006) 484. Mazzarino M., Turi S., Botre F. A screening method for the detection of synthetic glucocorticosteroids in human urine by liquid chromatography mass spectrometry based on class-characteristic fragmentation pathways. Anal Bioanal Chem. 2008; 390: 1389-1402. Ozkan Y., Savaser A., Tas C., Uslu B., Ozkan S. Drug dissolution studies and determination of deflazacort in pharmaceutical formulations and human serum samples by RP-HPLC. J Liq Chromatogr Rel Techno. 2003; 26: 2141-2156. Santos-Montes A., Gasco-Lopez AI., Izquierdo-Hornillos R. Optimization of the high- performance liquid chromatographic separation

of a mixture of natural and synthetic corticosteroids. J Chromatogr. 1993; 620: 15-23. Santos-Montes A., Gonzalo-Lumbreras R., Gasco-Lopez AI., Izquierdo-Hornillos R. Extraction and high-performance liquid chromatographic separation of deflazacort and its metabolite 21- hydroxydeflazacort: Application to urine samples. J Chromatogr B Biomed Appl. 1994; 657: 248-253. Santos-Montes A., Izquierdo-Hornillos R. Optimization of separation of a complex mixture of natural and synthetic corticoids by micellar liquid chromatography using sodium dodecyl sulphate: Application to urine samples. J Chromatogr B Biomed Sci Appl. 1999; 724: 53-63. Sweetman SC. Martindale: The Complete Drug Reference. 35th ed. Pharmaceutical Press, London, UK (2007) 1374.