ORION TELECOM NETWORKS INC. T1



Similar documents
VCL-PRI ISDN VALIANT COMMUNICATIONS LIMITED. Primary Rate (Euro-ISDN) Multiplexer. Product Brochure & Data Sheet

VALIANT COMMUNICATIONS

ORION TELECOM NETWORKS INC.

VALIANT COMMUNICATIONS LIMITED

VALIANT COMMUNICATIONS LIMITED

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

Headquarters: Phoenix, Arizona. Regional Office: Miami, Florida. Orion Telecom Networks Inc. Orion Telecom Networks Inc.

E1-GSM RION ORION TELECOM NETWORKS INC. E1 Channel Bank with 30 X GSM Wireless Interface(s) TELECOM NETWORKS

1. Overview. 2. F-bit Utilization

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

DataSMART 554 & 558 T1/FT1 Plug-in DSU/CSUs Page 1 of 8. T1/FT1 Single-port Plug-in DSU/CSUs

Loop-IP6700 TDMoEthernet

Loop-V4300 MINI DACS E1/ T1 CONVERTER

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

FOMi-E3, FOMi-T3 E3, T3, and HSSI Manageable Fiber Optic Modems

DXC Family. Multiservice Access Node FEATURES

Loop-IP6510 Multiple WAN Router/Bridge

IPmux-1E TDM Pseudowire Access Gateway

Cisco 8-Port Channelized T1/E1 Shared Port Adapter

WEB RANger-II Internet Access Router

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card

Product Overview. Features CHAPTER

User Manual. EtherUSB

Appendix D T1 Overview

TDMoEthernet. Description

G-TAP A Series // Data Sheet

Loop-IP6700 TDMoEthernet

Cisco 4-Port Clear Channel T1/E1 High-Speed WAN Interface Card for Cisco 2821, 2851, and 3800 Series Integrated Services Routers

Indoor / Outdoor Antenna

IPM-T1 T1/DS1 over IP Multiplexer

Foxboro Evo Process Automation System

3500/22M Transient Data Interface

Optimux-45, Optimux-45L Multiplexers for 21E1/28T1 over Fiber or T3

T3 Mux M13 Multiplexer

Waveguide Access Point WGA631. Product Guide

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

UPS Network Interface. Quick InstallationGuide

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

High-density rack with SNMP management provides E1/T1 and Ethernet services over copper and fiber. Data Sheet

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

T200, PTP/IEEE 1588 Grandmaster Clock and

Cisco Channelized T1/E1 and ISDN PRI Modules

Long Range Ethernet Extender

FCD-E1E Managed E1 and Fractional E1 Access Device

24-Port Channelized E1/T1 Line Card Overview

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

TNE1500-P and TNE1500-S Single Line T1 Network Extender Provider and Subscriber

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Cisco Channelized T1/E1 and ISDN PRI Modules for the Integrated Services Routers

Ha-VIS FTS 3000 Introduction and features

Intel NetStructure PBX-IP Media Gateway

Cisco CCNA Optional Semester 4 Labs Wide Area Networking LAB 1 T1 TSU WAN LINK OVERVIEW - Instructor Guide (Estimated time: 30 minutes)

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

Rack mounted telephone- and leased line modem for industrial applications

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

In addition to our VoiceDirector hardware products, the following SIP broadband devices are also compatible with VoiceDirector:

Quick Installation Guide. EtherFast 10/100M Switch. Model No.: SP624R.

Uninterruptible Power Supply

H.264 Internet Video Server

PE6108/PE6208/PE8108/PE8208

User Guide TL-SG1016/ TL-SG /24-port Gigabit Ethernet Switch

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

How To Connect A G.711 To A G711 Network With A Gbnet (G.723) (Gbnet) (Geo) (Ipnet) And Gb Net (G723.1)

IBM /100 Stackable Ethernet Hub

PE310G4BPi40-T Quad port Copper 10 Gigabit Ethernet PCI Express Bypass Server Intel based

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Ethernet hubs. 250 series 10/100 autosense hubs

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

FlexDSL MiniFlex. SHDSL.bis Up to 30Mbps Ddd. Ethernet. Features. Possible Applications

TC3848. Applications. A JumboSwitch Technology

T1 Networking Made Easy

User Manual. EtherUSB

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

How To Run An Nport I5000A Device Server

Network Management Card. User Manual

Optimux-134, Optimux-125

RGPS-7084GP-P. Industrial 12-port rack-mount managed Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E. ports and 4x1000Base-X, SFP socket

Chapter 4 T1 Interface Card

G.703 Fractional T1 Access Unit. User Guide

Loop-IP6702 TDMoEthernet

TAM Port T1 Access Multiplexer

TrueAlarm Fire Alarm Systems

Communicate and view data from meters with one simple device

BridgeWay Fixed Base Radio Telecom VoIP Gateway

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

T1/E1 High-Speed WAN Interface Card for Cisco 1861 Router

CS270F SmartSpan T1 Line Repeater w/addressable Bidirectional Loopback

TK800-Series Industrial GPRS / UMTS / LTE Router

Cisco Model DPC3010 DOCSIS 3.0 8x4 Cable Modem

SOLUTIONS FOR AN EVOLVING WORLD. T1/E1 and C Fiber Service Units

Telephone- and leased line modem for industrial applications TD-36

FarSync TE1R. A Universal PCI adapter for E1 and T1 (G.703 / G.704) connections for Linux and Windows

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

XPort Data Sheet. General Description

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

Product Specifications

Transcription:

RION TELECOM NETWORKS ORION TELECOM NETWORKS INC. T1 Protection (Fail-Over) Switch Product Brochure & Data Sheet Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51st Ave, Suite B240, Glendale AZ 85308 Phone: +1 480-816-8672 Fax: +1 480-816-0115 E-mail: sales@oriontelecom.com Website: http://www.oriontelecom.com Regional Office: Miami, Florida Orion Telecom Networks Inc. 4000 Ponce de Leon Blvd. Suite 470, Coral Gables, FL 33146 U.S.A. Phone: 1-305-777-0419, Fax: 1-305-777-0201 E-mail: sales@oriontelecom.com Website: http://www.oriontelecom.com 1

INDEX S. No. Particulars Pg. No. 1 Product Overview 3 2 Features 3 3 Benefits 4 4 Application Diagrams 5 5 Front View 6 6 Technical Specifications 7 7 Ordering Information 8 8 Support 9 CAUTION ELECTROSTATIC SENSITIVE DEVICES DO NOT OPEN OR HANDLE EXCEPT AT A STATIC-FREE WORKSTATION 2

Product Overview Orion s 4 Port T1 Protection (Fail-Over) Switch allows the user to connect upto four T1 lines from the telephone company to "active", as well as to "standby" terminal(s), such as data server(s) etc. at the customer premises. T1 Protection (Fail-Over) Switch In the event of the failure of the data server(s) / equipment connected to the "A / active" ports, the T1 Protection (Fail-Over) Switch shall automatically switch and connect the T1 line(s) from the telephone company to the data server(s) / equipment connected to "B / standby" ports. This ensures minimum downtime - that would have otherwise occurred due to equipment failure. Enhances the efficiency of that network. Application Diagram Working T1 Link Network Telco -T1 T1 Protection Switch Equipment - A Standby T1 Link Features Equipment - B Allows the users to connect upto 4 T1 lines from the Telephone Company to 4 active and 4 standby T1 terminals User configurable. May be used for a single T1 link and scaled upto 4 T1 links though user configuration Independent, user configurable switching parameters for each T1 link Built-in real-time clock / real-time logging maintains a history of all events Remotely accessible over a TCP-IP networks. Allows the user to access and carry out maintenance, or and T1 switch the links remotely, if required. 3

Benefits Allows the users to create and maintain active/standby/duplicate customer premises data networks/data servers, without requiring to bear the recurring $$$ expense of leasing additional expensive T1s lines from the telephone company Automatically switches the T1 link(s) from the Telephone Company between the "active" and "standby" T1 equipment at the customer premises, according to the customer-defined criterion Improves security. Allows the user to co-locate the "backup" / "standby" equipment in a different room/building and prevent data loss User programmable switching criterion independent for each T1 link Increases the reliability of the customer data/it networks without the recurring additional cost of leasing additional T1 lines from the telephone company. The equipment may be used to create secondary/backup systems at the customer premises to provide virtually uninterrupted service. User programmable criterion for switching between Active and Standby T1 Links at the customers premises: Loss Of T1 Signal (LOS) The Loss of Signal condition in a T1 may occur due to: a) The failure of the T1 Port of the customer premises equipment. b) Or due to loss of power to the customer premises equipment. c) Or due to the disconnection of the T1 cable between the Protection Switch and the T1 Port of the customer premises equipment. The cause of LOF is 2 out of 5 Ft bits are in error for D4 Framing and 2 out of 5 frame bits are in error for ESF framing. Loss Of Frame (LOF) Alarm Indication Signal (AIS) Remote Alarm (RA) CRC ERROR This Alarm is also known as Blue Alarm. This Alarm indicates unframed all ones being detected in the incoming pulses on the receiver of T1 Protection Switch. This Alarm is also known as Yellow Alarm. This Alarm indicates in D4 Framed bit 2 of each DS0 for 255 consecutive channels has been detected as a zero. When ESF Framed: Alternating eight ones/eight zeros have been detected in the ESF Datalink. A Yellow Alarm is typically transmitted to indicate a failure on the receive side of the Failed end. This parameter is the number of CRC-6 errors (Cyclic Redundancy Check Errors) that occurred during the test period. CRC-6 errors are only counted while the Telco T1 framing is selected as ESF (Extended Superframe). The CRC-6 can be monitored either on In-Service or Out-of-Service T1 Spans. Since the expected value of the CRC pattern can be anticipated, the received data can be compared to the expected results. Whenever the expected value does not equal the actual value a CRC error event is counted. 4

Application Diagram Telco T1 link connected to Equipment-A Working T1 Link Network Telco -T1 T1 Protection Switch Equipment - A Standby T1 Link Equipment - B Equipment-A fails - Telco T1 automatically switches to Equipment-B Failed Network Telco -T1 T1 Protection Switch Equipment - A Standby T1 Link connected to Equipment - B automatically connects and becomes a working Link Equipment - B Equipment-A recovers - Telco T1 automatically switches to Equipment-A Working T1 Link Recovers Network Telco -T1 T1 Protection Switch Equipment - A Standby T1 Link Please see note on page for recovery criteria selection. Equipment - B 5

T1 Protection (Fail-Over) Switch Shelf Description: The T1 Protection (Fail-Over) Switch is fitted in a 19-inch 1U shelf that provides access to all external interfaces. The T1 interfaces, power input and access and Management Ports (RS232) and 10BaseT Ethernet interfaces) are accessible from the front panel. The external alarm extension are accessible at the rear panel. Front view of the shelf 1 2 3 4 1A 2A 3A 4A 1B 2B 3B 4B T1 PROTECTION SWITCH TELCO T1 Links T1 EQUP-A T1 EQUP-B L1 LAN Port LAN ON/OFF LAN Reset COM PORT L2 L3 L4 L5 L6 PWR 7.5V DC T1 Protection (Fail-Over) Switch LED Indications The LEDs indicate the following: L1- (Green) LAN ON L2 - Equipment Port A In Use for at least one of the four (enabled) Links L3 - Equipment Port B In Use for at least one of the four (enabled) Links L4 - (Red) Self test failure/hardware failure L5 - (Green) + 5V DC L6 - (Green) - 48V DC Mechanical Specifications Rack mounting Height Depth Width Weight Standard 19-Inch. DIN Rack 44.00 mm. 260.00 mm. 477.00 mm. 4.00 kg. 6

Technical Specifications Network Interface Number of Interfaces 4 Telco T1 Links (common link/telco T1s) 4 Active T1 Links (for Equipment-A) 4 Standby T1 Links (for Equipment-B) Line Rate T1-1.544 Mbps Line Code B8ZS, AMI (User Selectable) Frame Structure SF, ESF (User Selectable) Bit Rate 1544 Kbps ± 50 ppm Jitter Tolerance As per ITU-T G.823 Output Jitter < 0.05 UI (in the frequency range of 20 Hz to 100 KHz) Nominal Line Impedance 100 Ohms Balanced RJ-45 Nominal Pulse Width 244ns Pulse Mask As per ITU (CCITT) Rec. G.703 Loss and recovery of As per clause 3 of ITU (CCITT) G.732 frame alignment Loss and recovery of As per clause 5.2 of ITU (CCITT) G.732 multiframe alignment AC Power Supply Specifications Output voltage of AC Adapter 100-240 Volt AC Range of input AC voltage 100V to 240V AC, 50Hz / 60Hz. System Input voltage 7.5V DC to 9.0V DC, DC input polarity protection. Maximum full load output current 2.5A at 7.5V DC / 9.0V DC Input voltage reversal protection Provided in the Card Efficiency at full load >86% Temperature Operating Humidity 0 0 0 C to 50 C 5% to 95% Non-Condensing 7

NMS (with Telnet) XPort Specifications Network Interface Compatibility Protocols Supported LEDs Management EMI Compliance RJ-45 Ethernet 10BaseT or 100BaseT-TX (auto sensing) Ethernet Version 2.0 IEEE802.3 ARP, UDP/IP, TCP/IP, Telnet, ICMP, SNMP, DHCP, BOOTP, TFTP, Auto IP, SMTP and HTTP 10Base-T and 100Base-TX Activity, full/half duplex Internal web server, SNMP (read only), Serial login, Telnet login - Radiated and conducted emissions - complies with Class B limits of EN55022:1998 - Direct and Indirect ESD - complies with EN55024:1998 - RF Electromagnetic Field Immunity - complies with EN55024:1998 - Electrical Fast Transient/Burst Immunity - complies with EN55024:1998 - Power Frequency Magnetic Field Immunity - complies with EN55024:1998 - RF Common Mode Conducted Susceptibility - complies with EN55024:1998 Management Ports (COM Port) Serial Port: 9.6Kbps (Async). ASCII/VT100/HyperTerminal. 10BaseT Ethernet: Telnet Command Language Command Line Interface (English text commands) Compliance/Regulatory EMC FCC Part 15 Class 2 Operation ETS 300 019 Class 3.2 Storage ETS 300 019 Class 1.2 Transportation ETS 300 019 Class 2.3 Ordering Information Sr. # Product Description Part # 1. 4 Port Protection (Fail-Over) Switch - 19 Shelf 1U High Mount Version -48V DC on-board power VCL-T1-PRO-1421 8

Note: Technical specifications are subject to changes without notice. All brand name and trademarks are the property of their respective owners. Revision 02 - May 31, 2007 Headquarters: Phoenix, Arizona Orion Telecom Networks Inc. 20100, N 51st Ave, Suite B240, Glendale AZ 85308 Phone: +1 480-816-8672 Fax: +1 480-816-0115 E-mail: sales@oriontelecom.com Website: http://www.oriontelecom.com Regional Office: Miami, Florida Orion Telecom Networks Inc. 4000 Ponce de Leon Blvd. Suite 470, Coral Gables, FL 33146 U.S.A. Phone: 1-305-777-0419, Fax: 1-305-777-0201 E-mail: sales@oriontelecom.com Website: http://www.oriontelecom.com 9