Food industry Prosecc industry Heat & power (Production of district heating & cooling) Food industry Process industry Logistic centres Sport arenas



Similar documents
Hybrid system. Energy-efficient and environmentally friendly

Oilon heat pump system references

ARP Food Industry, Portugal

Energy consumption and heat recovery of refrigeration system in modern Arena

6 18 A steam power plant receives heat from a furnace at a rate of 280 GJ/h. Heat losses to the surrounding air from the steam as it passes through

Heat Recovery from Data Centers. Guided Tour in Kista, January 21, 2015

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

District heating and district cooling with large centrifugal chiller - heat pumps

Building Energy Systems. - HVAC: Heating, Distribution -

HUB RADIATOR HYBRID. Multi-energy hybrid system to produce heating and DHW. Multi-energy hybrid system to produce heating, cooling and DHW

In the compression-refrigeration loop (air conditioning), which is likely to be warmer? 1. Condenser coil 2. Evaporator coil

Refrigeration and air-conditioning. Alfa Laval s offering at a glance

Evaluation of mobile storage systems for heat transport. G. Storch, A. Hauer, A. Krönauer ZAE Bayern, Walther-Meißner-Str. 6, Garching, Germany

Performance Evaluation of a Heat Pump System for Simultaneous Heating and Cooling

Chapter 3.4: HVAC & Refrigeration System

District heating and cooling in Stockholm Site visit to the Ropsten plant

Crowne Plaza Copenhagen Towers The world s greenest hotel

2015 CARNOT REFRIGERATION CO 2 PROJECTS IN DATA CENTRES, COMMERCIAL AND INDUSTRIAL REFRIGERATION CASE STUDIES

How To Clean Water From An Ammonia Refrigeration System

Neighbourhood Energy in Vancouver Sewage Heat Recovery within a city-wide strategy

ALFEA HYBRID DUO GAZ. New Model 2011

New technical solutions for energy efficient buildings

UNIT 2 REFRIGERATION CYCLE

Siemens turbine solutions for urban cogeneration

Geothermal Ice Arenas

PERFORMANCE EVALUATION OF NGCC AND COAL-FIRED STEAM POWER PLANTS WITH INTEGRATED CCS AND ORC SYSTEMS

Daikin Altherma hybrid heat pump. The natural combination

The Second Law of Thermodynamics

CCS in the Oil refining Industry System Solutions and Assessment of Capture Potential

The Second Law of Thermodynamics

HVAC Systems: Overview

Mechanical Heat Pumps Using Water as Refrigerant for Ice Production and Air Conditioning. Case studies

8. Heat pumps, heat pipes, cold thermal energy storage

In touch with heat pumps for industry and commerce

The natural ombination

OPTIMAL POLYGEN COOLING CONCEPT FOR ST. OLAVS HOSPITAL IN TRONDHEIM, NORWAY

The natural ombination

CHP Plant based on a Hybrid Biomass and Solar System of the Next Generation EU project No. ENER/FP7/249800/"SUNSTORE 4" Dipl.-Ing. Alfred Hammerschmid

We make rational and conscientious use of our

Solare termico altre applicazioni. G.V. Fracastoro

HEAT PUMPS A KEY COMPONENT IN LOW CARBON FUTURE

LG Electronics AE Company, Commercial Air Conditioning

/HNR: V1.0. John Bernander, Bioenergi som motor, Oslo

Natural geothermal energy.

Appendix C. Minimum Equipment Efficiency Standards

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Riga Smart City Concept. Timurs Safiuļins Riga Energy Agency

CHP and DHC in Helsinki

Daikin Altherma. hybrid heat pump. The natural combination

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

Typical Cooling Load Profile

Drives and motors. A guide to using variable speed drives and motors in data centres Meeting your Carbon Reduction Commitment (CRC)

3/29/2012 INTRODUCTION HVAC BASICS

Feasibility Study for Mobile Sorption Storage in Industrial Applications

Design Guide. Retrofitting Options For HVAC Systems In Live Performance Venues

GLOBACON 05 HVAC Systems for Cogen

The Technology and Business of Power Andrew Valencia, P.E. Lower Colorado River Authority

NFAT (Need for and Alternatives To)

CHP: Technology Update The Organic Rankine Cycle (ORC)

Energy Distribution: District Heating and Cooling - DHC M6_ ENERGY DISTRIBUTION: DISTRICT HEATING AND COOLING

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Commercial Gas Heat Pump - VRF

New absorption chillers for high efficient solar cooling systems

SECTION A... 3 SECTION B... 7

Creating Efficient HVAC Systems

University of Maryland College Park District Energy System. IDEA Campus Energy Conference February 9, 2012

Södra Näs Vimmerby Energi AB Biomass District Heating Plant, Sweden

How To Calculate The Performance Of A Refrigerator And Heat Pump

Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin

Your Partner for Concentrated Solar Power Generation The Heart of Your Process

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

2B.1 Chilled-Water Return (and Supply) Temperature B.3 Cooling-Water Supply Temperature / Flow

Ground Source Heat Pumps The Fundamentals. Southington, Connecticut John F. Sima III P.E.

Integrating renewable energy sources and thermal storage

Overview. PG&E and Energy Efficiency. CA Energy Efficiency Regulatory & Policy Roadmap. Financing Options for Efficiency & Demand Response

apv heat exchanger APV ParaFlow Plate Heat Exchangers

ROTEX Gas-Hybrid-Heat Pump

CONCENTRATING SOLAR POWER NOW CLEAN ENERGY FOR SUSTAINABLE DEVELOPMENT

Vicot Solar Air Conditioning. V i c o t A i r C o n d i t i o n i n g C o., l t d Tel: Fax:

25. Fachtagung von GEOTHERMIE.CH

Boilers and cogeneration/trigeneration. Abhi Sawant Business Development Manager Simons Green Energy

Thermal Coupling Of Cooling and Heating Systems

Xcel Business Customers: Program and Rebate Summary

Impact of Control System Technologies on Industrial Energy Savings

Split units TH with hermetic compressors

Energy Efficiency Best Practice Guide Industrial Refrigeration

Heating and cooling with wastewater

Energy Efficient Ammonia Heat Pump. Energy and Climate Refrigeration and Heat Pump Technology

AMMONIA AND CARBON DIOXIDE HEAT PUMPS FOR HEAT RECOVERY IN INDUSTRY

High Pressure Ammonia Systems New Opportunities

The Hybrid tri- genera0on system solar- bio- tric

High School Graduation years 2013, 2014, Unit/Standard Number

FLUXUS Energy. Manage energy effectively using non-invasive measuring technology. Heat usage, chilled flows and compressed air flow rate

Maximizing Boiler Plant Efficiency. Presenter: Dan Watkins, LEED BD+C Sales Engineer Bornquist, Inc.

Good Practice Form

HVAC For Schools How to purchase an HVAC system that meets your school s unique requirements and stays within your budget

Heat Pumps The Future of Heating in the UK?

HEATING, VENTILATION & AIR CONDITIONING

Summary technical description of the SUNSTORE 4 plant in Marstal

Transcription:

Johan Tallberg

Food industry Process industry Logistic centres Sport arenas Synergy Food industry Prosecc industry Heat & power (Production of district heating & cooling) Maintenance services for the smooth operation of customer s refrigeration plants and heat pumps

Hybrid plant for utilities Boiler, biomas COP 0,7 Boiler, Gas or oil COP 0,9 Oilon Scancool, heat pump, combined cooling and heating COP 5..9

Where is the beef? What is the idea? Principal form of energy Price Electricity 100 units/mwh Gás 60 units/mwh Oil 60 units/mwh Biomass 40 units/mwh When using heat pump COP 4 6 can be attchived. Price of energy is by then 100/4 100/6 that means 16 25 units/mwh Much cheaper than any other form.

20 C 1MW 80 C condensador compressor Válvula de expansão 0.2MW evaporador 10 C 0.8MW 30 C

Heat pump products: Private houses 5 28 kw Multi-apartment houses 16 85 kw Small industrial premises 35 300 kw

Heat pump: Tailored heat pumps for solutions Piping, heat exchangers, installations Automation Turn key solutions Programmable automation According requirements Light, medium or advance Heat pumps capacities Scancool 0,1 1,5 MW Specified maintenance services

Heat pumps 90 t[ºc] output 80 70 60 50 Space heating District heating Process heating Ground source Sea, river, waste water Cooling towers, Cooling systems RE Scroll 80 700 kw S Twin screw 100 2000 kw 40 30 20 Ice rink Freezing Water chiller P Parallel pistons 80 500 kw 10 0-30 -20-10 0 10 20 30 t[ºc] collector temperature

Hybrid Heat & Cool Combination of heat sources the Hybrid

Flue Gas Heat Recovery Save energy Earn more Pay less

Waste Water Heat Recovery Could we just waste it! Energy capture from purified waste water

Industrial Cooling Heat Recovery Wasting condensation heat? Turn it to heating energy

Combined Heating & Cooling 2 in 1 1 for 2 Why invest for twodevices when just onecould do it

Scancool Heat pumps Main applications Retrofit or grasroot designs Heat sources Flue gas heat recovery Lake or sea Ground heat Communal Waste water District or local cooling Industrial waste water Process cooling Cooling plant waste heat District heating Local heating Industrial space heating Industrial process water Industrial process heating Heat sinks

Industrial heat pump The Concept 1MW Oil 1MW 20 C 80 C 0.2MW Heat pump 10 C 30 C 0.8MW 1 MW Oil 0.2 MW Electr. CO2 t/a 2628 350 Price of energy /MWh 110 22

Food industry, Snellman Pietarsaari, Refrigeration plant heat recovery Before After 75 C 75 C 1.4MW Hot water Space heating 0MW 1.4MW Hot water Space heating Steam from oil furnace Steam from oil furnace 50 C 50 C 3MW NH3 condenser 0.3MW Scancool HHP391i 1.4 MW COP 4-5 1.9MW 3MW NH3 condenser NH3 compressors 31 C, 12bar NH3 liquid NH3 compressors 31 C, 12bar NH3 liquid

References Food production, Snellman Pietarsaari, Waste water heat recovery Snellman s Meat process plant 1951 founded family owned business Purchasing and abattoir Meat cutting and processing Cold water in 20 C 55 C Waste water Scancool HP318 1.2MW COP 5.0 10 C 30 C Wastewater treatment Process

Food production, Snellman Pietarsaari, Waste water heat recovery Facts (HP Heat pump) Hot water production up to 55⁰C Max heating capacity 1.2 MW COP 5 3 slide controlled screw compressors Heat source: Waste water 30⁰C Evaporators: HFC/waste water Vahterus PSHE Upstream washing function Washing function once per month Condensers Alfa Laval BPHE PLC automation for heat recovery Estimated simple pay pack time 3 years

Food industry, Snellman Pietarsaari, Refrigeration plant heat recovery Facts (HHP Heat pump) Hot water production up to 75 C Max heating capacity 1.4 MW COP 4-5 Heat source condensing NH3 (ammonia) Tailored PLC automation system Estimated simple pay pack time 1.5 years

Dairy & Creamery, Valio Riihimäki, Refrigeration plant heat recovery Facts (HP Heat pump) Hot water production up to 60 C Max heating capacity 1.1 MW COP 5.8 Heat source condensing NH3 (ammonia) Soft started screw compressors PLC automation system Estimated simple pay pack time 1.4 years

16 heat exchanger for process and space heating 3.3 MW low price heat energy Cooling water return 48ºC Local heating water return 40ºC Local Heating water 70ºC Dairy, Valio Seinäjoki Combined heating & cooling 1.6 MW Cooling water 25ºC Condensor of the milk evaporator Utilities 5.8 MW Electricity need 0.6 MW COPtot = 9 Layout 3.3m x 7.9m 0.9 MW More capacity needed Process and space cooling COP 5.2 Cooling 1.6 MW Heating 1.9 MW HHP292i Ice water return 6ºC Ice water 1ºC HHP391ic Ice water 2ºC COP 2.7 Cooling 0.9 MW Heating 1.4 MW Existing refrigeration plant COP 3.7

Oilon offers turn key solutions in South America. Please visit our booth in the EXPO area. Partner with DUEIK EQUIPOS TERMICOS, Santiago