FT-100 Fire Training Fog Machine User Manual English



Similar documents
High Efficiency Vaporizing System and Highly Durable Heaters Ensure 25% Increased Output.

TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4

Bubble King. User Manual

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

MultiDim MKII V.2 ORDERCODE 50386

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

LED Par 56 Short DMX ORDERCODE 42421

Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

Cable Tester Pro ORDERCODE D1909

19 LED Tube Controller ORDERCODE 41003

Manual. base*classic and. base*classic*cased

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

1. Before You Begin... 3

Ref. Nr LCP-288 LED COLOR PANEL 288X LED 5MM MANUAL

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

MANUAL ENGLISH. Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Sunstrip Active DMX ORDERCODE 30710

ComPar KIT 1 & 2 DMX LED light set

Shogun Blue Laser Head ORDERCODE 30972

Congratulations! Thank you!

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

LED Cube Direct Control 30 ORDERCODE 41131

PORTABLE AIR CONDITIONER

INSTRUCTION MANUAL CIRRO MK 3/TYPE 2 MIST GENERATOR

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

TABLE OF CONTENTS QUICK START... 1 DIAGRAM OF THE DIGITAL PHOTO FRAME... 2 KEYPAD BUTTON FUNCTIONS... 3 REMOTE CONTROL FUNCTIONS..

Ultrasonic support removal tank

XPanel V2. Remote Control Panel. User Manual. XILICA Audio Design

Indoor Remote Controlled Power Points

LED BAR 126 / 252 RGB. Owner s Manual LED BAR RGB

PROFESSIONAL WIRELESS DMX CONTROLLER USER S MANUAL EWDMXSYSTEM

Meaco 30L and Meaco 40L dehumidifier instruction manual

Portable Air Conditioner

MS-800B Mobile Video Studio

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Cambridge Electric Infared Fireplace User Manual

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

ORLAND FOLLOW PR-1211

USER S MANUAL. Duct Type Series. Free Joint Multi Air Conditioner (Cooling and Heating) FUEA Series E S F I P D G DB A(1) ENGLISH ESPAÑOL

CARING FOR YOUR WATER HEATER

MANUAL ENGLISH UBR-180BT Ordercode: D1258

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

How To Use A Power Supply Unit (Upu)

Showmaster 48 ORDERCODE 50356

USER S MANUAL HSC-24A

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

K E E P E TH T I H S I MA M N A U N A U L A FO F R

TABLE OF CONTENTS. 6. Technical Specifications Page 2 of 20 COLORband PiX User Manual (Rev. 02)

LED Par 56 Ultra Bright RGB Black ORDERCODE Polished ORDERCODE 42451

K E E P E TH T I H S I MA M N A U N A U L A FO F R

MA-4150 ORDERCODE D6149 Highlite International B.V.

STAGE SETTER-8. User Instructions. Elation Professional

SERVICE MANUAL. Room Air Conditioner Multi Split Wall-Mounted Type Indoor. FSAI-Pro-91AE2 FSAI-Pro-121AE2 FSAIF-Pro-181AE2

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

ENGLISH PSS-108 MKII / PSS-110 MKII

Dehumidifier Users manual. For Models: DH45S DH65S

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

USER MANUAL PLEASE KEEP THIS FOR FUTURE USE

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

1. BEFORE YOU BEGIN INTRODUCTION SETUP AC POWER... 7 Power Linking... 7 MOUNTING... 8 Orientation... 8 Rigging...

VF400. User Instructions

TABLE OF CONTENTS. Returns Contact Us... 20

OPTIONAL SLENDER REMOTE CONTROL

Operating Instructions Split System Air Conditioner

LX650 Lamp/Filter Replacement Instruction Sheet

LX150 LUXIBEL - PIXDRIVE KLING-NET/ART-NET USER MANUAL

User Manual. Video Doorphone CDV-1020AQ

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Ref. Nr WI-PAR 8X 3W LED TRI COLOR BATTERY 2.4GHZ DMX MANUAL

CINEMATE 1 SR DIGITAL HOME THEATER SPEAKER SYSTEM. Operating Guide Guía del usuario Guide d utilisation

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

USER S MANUAL FH052EAV1 FH070EAV1. System Air Conditioner (Cooling and Heating) ENGLISH ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH E HNIKA

Moving Head - One Signal Cable - One Omega Clamp One Power Cable - One Safety

2XWSXWFKDQQHOV 3KDVH &+ CH 2 &+ CH 4 &+ CH 6 L1 X X L2 X X L3 X X

ZaapTV HD509N. User s Guide. How to use the HD509N set-top box

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Antenna Splitter ASA 1. Instruction manual

Manual for Fire Suppression & Methane Detection System

BOSE. Link AL8 HOMEWIDE WIRELESS AUDIO LINK

OPTI TRI PAR. User Instructions. Elation Professional 6122 S. Eastern Ave. Los Angeles CA

Register your product and get support at. AS111. User manual

floater imports DF169 ECO AIR COOLER EVAPORATIVE AIR COOLER WITH IONIZER USER S MANUAL

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

User s Manual. Copyright 2014 Trick Technologies Oy

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

Viper 2.6 Viper deluxe

Get Me Cool Now Portable Air Conditioner User s Manual

RX-18B ORDERCODE D3314

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Descriptive Technical Documentation. DTD no

Transcription:

FT-100 Fire Training Fog Machine User Manual English 2015 Antari Lighting and Effects Ltd.

User Manual - English Safety Information Please read the following safety information carefully before operating the machine. Information includes important safety information about installation, usage, and maintenance. Pay attention to all warning labels and instructions in this manual and printed on the machine. If you have questions about how to operate the machine safely, please contact your local Antari dealer for help. Keep this device dry. Always connect to a grounded circuit to avoid risk of electrocution. Before connecting machine to power, always check voltage indicate on machine match to your local AC voltage. Do not use the machine if AC power voltage does not match. Disconnect the machine from AC power before servicing and when not in use. This product is for indoor use only! Do not expose to rain or moisture. If fluid is spilled, disconnect AC power and clean with a damp cloth. If fluid is spilled onto electronic parts, immediately unplug the machine and contact your local Antari dealer for advice. No user serviceable and modifiable parts inside. Never try to repair this product, unauthorized technician may lead machine to damage or malfunction. For adult use only. Never leave the machine running unattended. Installed in well ventilated area. Provide at least 50 cm space around the machine. Never add flammable liquid of any kind to the machine. Make sure there are no flammable materials close to the machine while operating. Only use Antari fluid. Other fluid may lead to heater clog and malfunction. If the machine fails to work, unplug the machine and stop operation immediately. Contact your local Antari dealer for advise. Before transporting the machine, make sure the fluid tank is completely drained. 2

Smoke fluid may present health risks if swallowed. Do not drink smoke fluid. Store it securely. In case of eye contact or if fluid is swallowed immediately look for medical advice. Unpacking and Inspection Immediately upon receiving the machine, carefully unpack the carton, check all content to ensure that all parts are present and have been received in good condition. If any parts appear damaged or mishandled from shipping, notify the shipper immediately and retrain the packing material for inspection. What is included: 1 x FT-100 Fog Machine 1 x W-1 Wireless Remote 1 x Power Cord 1 x User Manual Product Dimension 264.5 mm 278.2 mm 580 mm Product Overview Wireless Reciver (W-1 Wireless Remote) Remote Control (Z-3 Remote) XLR 5-Pin DMX Connector XLR 5-Pin DMX Connector Two rotary knobs Timer / Volume 3

Setting Up Step 1: Place the machine on a flat surface and in a suitable large area with at least 50 cm open space around the machine. Step 2: Fill the fluid tank with Antari approved fluid. Step 3: Connect the machine to suitable rated power supply. To determine the power requirement for the machine refer to the label on the back of the machine. Always connect the machine to a protected circuit and ensure it is properly grounded to avoid risk of electrocution. Step 4: Turn on the machine and allow it to heat up. Heat up takes approximatly 10 mintues. Once the machine has reached operating temperature, the LCD display will show Ready To Fog. Now the machine is ready for operation. Step 5: To start making fog, locate the rotary knob on the right side of control panel, and press the rotary knob to start making fog. Step 6: To turn off the machine, press rotary knob again button and turn Powercon to the OFF position. Operation Control Panel Operation The machine can be operated with onboard digital control interface 4

Operation - Timer Mode Rotary knob Action Description Left Press once Activate timer mode Right Press second time Deactivate timer mode Right Rotate Adjust output volume Operation Volume Mode Rotary knob Action Description Right Press once Activate volume mode Right Press second time Deactivate volume mode Right Rotate Adjust output volume Setting Rotary knob Action Description Left Press and hold for 3 Enter setting menu seconds Left Rotate Scroll through menus Left Press Press once to enter Left Rotate Adjust for preferred value Right Press Escape from menu 5

Control Menu Interval Set XXX S Set interval time from 5 to 200 seconds Duration Set XXX S Set duration time from 1 to 200 seconds Timer Output XXX % Set output volume from 1 to 100% Volume Output XXX % Set output volume from 1 to 100% DMX512 Address:XXX Set DMX address from 1 to 512 Wireless ON Turn ON or OFF wireless remote feature Fluid Sensor Set ON Turn ON or OFF fluid sensor W-DMX Power OFF Turn ON or OFF wireless DMX module Run Last Setting OFF Turn ON or OFF memory setting. When turn ON the machine will return to its original state before last shut off. Keypad Sound ON Turn ON or OFF rotary knob sound 6

Wireless Detect Pair Pair or un-pair wireless remote Nonstop Burst OFF Turn ON or OFF nonstop burst function. Once turn on machine can produce output continously without reheat Wireless Operation Wireless remote control system W-2 consists of a transmitter equipped with four buttons to activate, deactivate, increase and decrease fog output and an onboard receiver attached to the rear panel of FT-100 fog machine. W-2 Wireless Transmitter Press [A] button to emit fog. Press [B] button to stop. Press [C] button to increase output volume. Press [D] button to decrease output volume. In a free open space the effective distance is 50 meters, actual usage depending on obstacle level the effective distance is 10-25 meters. Wireless Receiver 7

Registering transmitter Transmitter can be pair or deleted from the receiver. Each receiver can pair up to 5 transmitters. Follow below steps to pair or delete transmitter from receiver. Step 1: Press and hold left rotary knob for 3 seconds to enter setting menu Step 2: Rotate the rotary knob to find Wireless Detect menu Step 3: Follow the menu instruction to pair or delete transmitter Transmitter battery replacement If effective distance seems to be decreased, it is possible the battery level are low and require replacement. In order to replace the battery, undo the three screws on the back of transmitter to release the cover. Replace with same type and specification of battery which is 27A 12V DMX Connector Pin Assignment The machine provide 3 or 5 pin XLR connector for DMX connection. Diagram below indicate pin assignment information Pin Function 1 Ground 2 Data- 3 Data+ DMX Channel Function Channel 1 DMX Value Range Function Fog 0 4 Fog Off 5 255 Output 1-100% 8

Fluid Only use Antari FLP water-based liquid for the FT-100 Fire Training Fog Machine. The machine is tested and calibrated with this liquid to get the best output performance. Warranty will be void if any other type of liquid is used, improper use of liquid may lead to machine failure and malfunction. Service and Maintenance Do not allow the machine to become contaminated. Remove dust from air vents with air compressor, vacuum or a soft brush. Only use a damp cloth to clean the casing. Before storing run distilled water through the system to help avoid condensing the pump or heater. It is recommended to run the machine on a monthly basis in order to achieve best performance and output condition. Excessive dust, liquid and dirt built up will degrade performance and cause overheating. Breaker Reset Disconnect AC power before reset breaker. Only replace fuse with same type and rating. Step 1: Disconnect AC power Step 2: Flip breaker to ON position Step 3: Turn on machine to test Breaker 120V = 15A 250V 230V = 7A 250V 9

Technical Specifications Input voltage Breaker Heater Warm-up time Output Max. operating time Fluid tank capacity Fluid consumption Compatible fluid Control option DMX channels Power connection DMX data connection Dimension Dry weight US 120V EU 230V UK 240V JP 100V 120V = 15A 250V 230V = 7A 250V 1500W 10 min. (approx.) 20,000 cu.ft/min 1 min at 100% output, 60 mins at continuous output 6 L 100 ml/min Antari FLP water-based fluid DMX 512, Manual, Timer, Wireless remote 1 channels Neutrik Powercon 5-pin XLR L 580 x W 278.2 x H 264.5 mm 14.6 kg 10

C08FT1000