Page 2 of 35 Table of Contents Cover Page Table of Contents Intro Page General Summary Electrical Summary Plumbing Summary Structural Summary Heating Cooling / Summary 1 Roofing, Roof Structure, Chimneys, and Attic 2 Exterior 3 Structural Components 4 Plumbing System for Building 5 Garage 6(A) 1st Floor 6(B) 2nd floor Invoice
Page 3 of 35 Date: 12/23/2013 Time: Report ID: Property: Customer: Mr. Happy Comment Key or Definitions Real Estate Professional: Glen Tomlinson Century 21 United II The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this building. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property. Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear. Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting. Not Present (NP) = This item, component or unit is not in this building or building. Repair or Replace (RR) = The item, component or unit is not functioning as intended, or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement. Standards of Practice: NACHI National Association of Certified Home Inspectors, Illinois In Attendance: Customer Type of building: Multi-family Style of Home: 2 Flat brick Approximate age of building: 90 Home Faces: South Temperature: 31 Weather: Cloudy Ground/Soil surface condition: Frozen Rain in last 3 days: Yes
Page 4 of 35 General Summary 6334 W. Grace st Chicago Illinois 60634 1-773-454-6700 Customer Mr. Happy Address The following items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the building. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report. 1. Roofing, Roof Structure, Chimneys, and Attic 1.0 ROOF COVERINGS Not Inspected Roof decking above enclosed porch is water damaged and needs replacement. Item 1(Picture) At time of inspection there were no active leaks into the apartment. 1.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS Chimneys need tuckpointing and a rain cap installed if they are to be continued to be used. Item 1(Picture) Item 2 (Picture) 1.3 ROOF DRAINAGE SYSTEMS Gutter has visible holes and needs to be replaced. Item 1(Picture) Downspout needs to be reconnected to sewer. Item 2(Picture) Item 3(Picture) 2. Exterior 2.0 WALL CLADDING FLASHING AND TRIM OSB sheathing has been water damaged and has lost its structural integrity,replacement is recommended. Item 1 (Picture) 2.1 DOORS (Exterior) Front entrance door is serviceable. Item 1(Picture) Back door is deteriorated. Item 2(Picture)
Page 5 of 35 2. Exterior 2.2 WINDOWS Thermopane windows in both apartment have broken seals. Item 1(Picture) 4. Plumbing System for Building 4.3 MAIN WATER SHUT-OFF DEVICE (Describe location) Not Inspected I could not locate the main shut-off for water? Please ask the current owners for the location. Otherwise, you will need to use a water key at the street meter or have a plumber install one. 5. Garage 5.4 ROOF Garage roof is in poor condition and needs to be replaced. Item 1(Picture) 5.5 Garage structure Garage structure appears to be sound. But is in need of roofing,siding, patio door and entrance door. Garage was boarded up at time of inspection and interior could not be seen. Item 1(Picture) 6(A). 1st Floor 6.1.A 6.3.A 6.5.A WALLS Inspected Apartment has many holes in the walls. Item 1(Picture) Item 2(Picture) DOORS (REPRESENTATIVE NUMBER) Rear door is off hinges. Item 1(Picture) COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS Not Present Cabinets missing. 6(B). 2nd floor 6.4.B 6.9.B WINDOWS (REPRESENTATIVE NUMBER) Repair or Replace Some windows have been removed and are boarded up. STEPS, STAIRWAYS, BALCONIES AND RAILINGS Missing hand rail. Item 1(Picture)
Page 6 of 35 building inspectors are not required to report on the following: Life expectancy of any component or system; The causes of the need for a repair; The methods, materials, and costs of corrections; The suitability of the property for any specialized use; Compliance or non-compliance with codes, ordinances, statutes, regulatory requirements or restrictions; The market value of the property or its marketability; The advisability or inadvisability of purchase of the property; Any component or system that was not observed; The presence or absence of pests such as wood damaging organisms, rodents, or insects; or Cosmetic items, underground items, or items not permanently installed. building inspectors are not required to: Offer warranties or guarantees of any kind; Calculate the strength, adequacy, or efficiency of any system or component; Enter any area or perform any procedure that may damage the property or its components or be dangerous to the building inspector or other persons; Operate any system or component that is shut down or otherwise inoperable; Operate any system or component that does not respond to normal operating controls; Disturb insulation, move personal items, panels, furniture, equipment, plant life, soil, snow, ice, or debris that obstructs access or visibility; Determine the presence or absence of any suspected adverse environmental condition or hazardous substance, including but not limited to mold, toxins, carcinogens, noise, contaminants in the building or in soil, water, and air; Determine the effectiveness of any system installed to control or remove suspected hazardous substances; Predict future condition, including but not limited to failure of components; Since this report is provided for the specific benefit of the customer(s), secondary readers of this information should hire a licensed inspector to perform an inspection to meet their specific needs and to obtain current information concerning this property. Prepared Using HomeGauge http://www.homegauge.com : Licensed To Joseph Poelsterl
Page 7 of 35 Electrical Summary 6334 W. Grace st Chicago Illinois 60634 1-773-454-6700 Customer Mr. Happy Address The following Electrical items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the building. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report. 6(A). 1st Floor 6.8.A OUTLETS AND WALL SWITCHES Electrical receptacles within six feet of a sink must be changed to a gfci type. Item 1(Picture) Item 2(Picture) Several receptacles in apartment tested with reverse polarity. Item 3(Picture) Item 4(Picture) 6.13.A 6.16.A SERVICE ENTRANCE CONDUCTORS Electrical service cable is not attached to porch wall. Item 1(Picture) POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE Exposed wiring should be removed or made safe. Item 1(Picture) Item 2(Picture) All electrical receptacles within 6 feet of a sink must be changed to a gfci type. 6(B). 2nd floor 6.8.B 6.16.B OUTLETS AND WALL SWITCHES Many electrical receptacles do not have a ground. Item 1(Picture) POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE Updating of electrical receptacles is recommended.
Page 8 of 35 Prepared Using HomeGauge http://www.homegauge.com : Licensed To Joseph Poelsterl
Page 9 of 35 Plumbing Summary 6334 W. Grace st Chicago Illinois 60634 1-773-454-6700 Customer Mr. Happy Address The following Plumbing items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the building. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report. 4. Plumbing System for Building 4.0 PLUMBING DRAIN, WASTE AND VENT SYSTEMS House catch basin needs cleaning and minor masonry repair. Item 1(Picture) 4.1 PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES Toilet missing in lower level. Item 1(Picture) Water service has been shut off to entire building. Item 2(Picture) Water piping and mixer valve is missing. Item 3(Picture) Kitchen sink and cabinets missing. Item 4(Picture) 4.2 HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS The T&P (Test and Pressure) valve on water heater needs a 3/4 threaded pipe to extend within 6 inches of floor for safety. (PVC is not approved for hot water use). I recommend repair by a qualified person.item 1(Picture) Item 2 (Picture) 4.3 MAIN WATER SHUT-OFF DEVICE (Describe location) Not Inspected I could not locate the main shut-off for water? Please ask the current owners for the location. Otherwise, you will need to use a water key at the street meter or have a plumber install one. 6(A). 1st Floor 6.6.A PLUMBING SUPPLY, FIXTURES IN THIS UNIT Not Present Water supply has been removed.
Page 10 of 35 Prepared Using HomeGauge http://www.homegauge.com : Licensed To Joseph Poelsterl
Page 11 of 35 Structural Summary 6334 W. Grace st Chicago Illinois 60634 1-773-454-6700 Customer Mr. Happy Address The following Structural items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the building. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report. 2. Exterior 2.0 WALL CLADDING FLASHING AND TRIM OSB sheathing has been water damaged and has lost its structural integrity,replacement is recommended. Item 1 (Picture) 3. Structural Components 3.0 FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) There is evidence of water intrusion from the east side of foundation wall. Item 1(Picture) Item 2(Picture) 3.1 WALLS (Structural) Building is in need of complete tuckpointing work, Item 1(Picture) Item 2(Picture) Item 3(Picture) Item 4(Picture) Item 5(Picture) Item 6(Picture) Item 7(Picture) Item 8(Picture) Prepared Using HomeGauge http://www.homegauge.com : Licensed To Joseph Poelsterl
Page 12 of 35 Heating Cooling / Summary 6334 W. Grace st Chicago Illinois 60634 1-773-454-6700 Customer Mr. Happy Address The following Heating and Cooling items or discoveries indicate that these systems or components do not function as intended or adversely affects the habitability of the dwelling; or warrants further investigation by a specialist, or requires subsequent observation. This summary shall not contain recommendations for routine upkeep of a system or component to keep it in proper functioning condition or recommendations to upgrade or enhance the function or efficiency of the building. This Summary is not the entire report. The complete report may include additional information of concern to the customer. It is recommended that the customer read the complete report. 4. Plumbing System for Building 4.4 FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) Inspected Gas service is shut off and could not be checked. 6(A). 1st Floor 6.10.A 6.12.A HEATING EQUIPMENT Gas service off in building and furnace could not be tested. Note furnace is very old and is past economical life. Item 1(Picture) CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water heaters or heat systems) Inspected Flue pipe is open in basement from removed space heater. 6(B). 2nd floor 6.10.B HEATING EQUIPMENT Inspected Furnace not tested due to gas shut of in building. Item 1(Picture) Prepared Using HomeGauge http://www.homegauge.com : Licensed To Joseph Poelsterl
Page 13 of 35 1. Roofing, Roof Structure, Chimneys, and Attic The building inspector shall observe: Roof covering; Roof drainage systems; Flashings; Skylights, chimneys, and roof penetrations; and Signs of' leaks or abnormal condensation on building components. The building inspector shall: Describe the type of roof covering materials; and Report the methods used to observe the roofing. The building inspector is not required to: Walk on the roofing; or Observe attached accessories including but not limited to solar systems, antennae, and lightning arrestors. IN NI NP RR 1.0 ROOF COVERINGS 1.1 ROOF FLASHINGS 1.2 SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS 1.3 ROOF DRAINAGE SYSTEMS 1.4 ROOF STRUCTURE AND ATTIC (report leak signs or condensation) 1.5 ATTIC INSULATION IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace IN NI NP RR Styles & Materials Roof-Type: Flat Roof Covering: Built-up Tar and gravel Chimney (exterior): Brick Metal Flue Pipe Sky Light(s): None Roof Ventilation: None found Method used to observe attic: Inaccessible Roof Structure: Not visible Ceiling Structure: Not visible Attic info: No Storage Attic sealed Attic Insulation: Unknown Comments: 1.0 Roof decking above enclosed porch is water damaged and needs replacement. Item 1(Picture) At time of inspection there were no active leaks into the apartment. 1.0 Item 1(Picture) Roof decking above enclosed porch is water damaged and needs replacement.
Page 14 of 35 1.2 Chimneys need tuckpointing and a rain cap installed if they are to be continued to be used. Item 1(Picture) Item 2 (Picture) 1.2 Item 1(Picture) Chimneys need tuckpointing and a rain cap installed if they are to be continued to be used. 1.2 Item 2(Picture)
Page 15 of 35 1.3 Gutter has visible holes and needs to be replaced. Item 1(Picture) Downspout needs to be reconnected to sewer. Item 2(Picture) Item 3(Picture) 1.3 Item 1(Picture) Gutter has visible holes and needs to be replaced. 1.3 Item 2(Picture) Downspout needs to be reconnected to sewer. 1.3 Item 3(Picture) 1.4 Attic is sealed. No leaks were observed. 1.5 Attic sealed and could not check if there is insulation. The roof of the building was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Roof coverings and skylights can appear to be leak proof during inspection and weather conditions. Our inspection makes an attempt to find a leak but sometimes cannot. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Page 16 of 35 2. Exterior The building inspector shall observe: Wall cladding, flashings, and trim; Entryway doors and a representative number of windows; Garage door operators; Decks, balconies, stoops, steps, areaways, porches and applicable railings; Eaves, soffits, and fascias; and Vegetation, grading, drainage, driveways, patios, walkways, and retaining walls with respect to their effect on the condition of the building. The building inspector shall: Describe wall cladding materials; Operate all entryway doors and a representative number of windows; Operate garage doors manually or by using permanently installed controls for any garage door operator; Report whether or not any garage door operator will automatically reverse or stop when meeting reasonable resistance during closing; and Probe exterior wood components where deterioration is suspected. The building inspector is not required to observe: Storm windows, storm doors, screening, shutters, awnings, and similar seasonal accessories; Fences; Presence of safety glazing in doors and windows; Garage door operator remote control transmitters; Geological conditions; Soil conditions; Recreational facilities (including spas, saunas, steam baths, swimming pools, tennis courts, playground equipment, and other exercise, entertainment, or athletic facilities); Detached buildings or structures; or Presence or condition of buried fuel storage tanks. The building inspector is not required to: Move personal items, panels, furniture, equipment, plant life, soil, snow, ice or debris that obstructs access or visibility. IN NI NP RR 2.0 WALL CLADDING FLASHING AND TRIM 2.1 DOORS (Exterior) 2.2 WINDOWS 2.3 2.4 DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES, PATIO/ COVER AND APPLICABLE RAILINGS VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIO FLOOR, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) 2.5 PLUMBING WATER FAUCETS (hose bibs) 2.6 POLARITY AND GROUNDING OF RECEPTACLES ON EXTERIOR WALLS OF INSPECTED STRUCTURE IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace IN NI NP RR Comments: Styles & Materials Siding Style: Lap Brick Siding Material: Vinyl Full brick Exterior Entry Doors: Steel Appurtenance: Covered porch Driveway: Street Parking 2.0 OSB sheathing has been water damaged and has lost its structural integrity,replacement is recommended. Item 1 (Picture) 2.0 Item 1(Picture) OSB sheathing has been water damaged and has lost its structural integrity,replacement is recommended. 2.0 Item 2(Picture)
Page 17 of 35 2.1 Front entrance door is serviceable. Item 1(Picture) Back door is deteriorated. Item 2(Picture) 2.1 Item 2(Picture) Back door is deteriorated. 2.1 Item 1(Picture) Front entrance door is serviceable. 2.1 Item 3(Picture)
Page 18 of 35 2.2 Thermopane windows in both apartment have broken seals. Item 1(Picture) 2.2 Item 1(Picture) Thermopane windows in both apartment have broken seals. 2.5 Hose bib is located on west exterior wall. 2.6 No exterior receptacle. The exterior of the building was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report.
Page 19 of 35 3. Structural Components The building Inspector shall observe structural components including foundations, floors, walls, columns or piers, ceilings and roof. The building inspector shall describe the type of Foundation, floor structure, wall structure, columns or piers, ceiling structure, roof structure. The building inspector shall: Probe structural components where deterioration is suspected; Enter under floor crawl spaces, basements, and attic spaces except when access is obstructed, when entry could damage the property, or when dangerous or adverse situations are suspected; Report the methods used to observe under floor crawl spaces and attics; and Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components. The building inspector is not required to: Enter any area or perform any procedure that may damage the property or its components or be dangerous to or adversely effect the health of the building inspector or other persons. 3.0 FOUNDATIONS, BASEMENTS AND CRAWLSPACES (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) IN NI NP RR 3.1 WALLS (Structural) 3.2 COLUMNS OR PIERS 3.3 FLOORS (Structural) 3.4 CEILINGS (structural) IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace IN NI NP RR Comments: Styles & Materials Foundation: Poured concrete Method used to observe Crawlspace: Walked Floor Structure: Wood joists Wood beams Wall Structure: Masonry Columns or Piers: Wood piers Floor System Insulation: NONE 3.0 There is evidence of water intrusion from the east side of foundation wall. Item 1(Picture) Item 2(Picture) 3.0 Item 1(Picture) There is evidence of water intrusion from the east side of foundation wall. 3.0 Item 2(Picture)
Page 20 of 35 3.1 Building is in need of complete tuckpointing work, Item 1(Picture) Item 2(Picture) Item 3(Picture) Item 4(Picture) Item 5 (Picture) Item 6(Picture) Item 7(Picture) Item 8(Picture) 3.1 Item 1(Picture) Building is in need of complete tuckpointing work, 3.1 Item 2(Picture) 3.1 Item 3(Picture) 3.1 Item 4(Picture)
3.1 Item 5(Picture) 3.1 Item 6(Picture) 3.1 Item 7(Picture) 3.1 Item 8(Picture) Page 21 of 35
3.2 Wood columns appear to be in good condition. Item 1(Picture) 3.2 Item 1(Picture) Wood columns appear to be in good condition. 3.3 Floor system appears to be sound. 3.4 Ceiling structure appears to be sound. The structure of the building was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. Page 22 of 35
4. Plumbing System for Building The building inspector shall observe: Interior water supply and distribution system, including: piping materials, supports, and insulation; fixtures and faucets; functional flow; leaks; and cross connections; Interior drain, waste, and vent system, including: traps; drain, waste, and vent piping; piping supports and pipe insulation; leaks; and functional drainage; Hot water systems including: water heating equipment; normal operating controls; automatic safety controls; and chimneys, flues, and vents; Fuel storage and distribution systems including: interior fuel storage equipment, supply piping, venting, and supports; leaks; and Sump pumps. The building inspector shall describe: Water supply and distribution piping materials; Drain, waste, and vent piping materials; Water heating equipment; and Location of main water supply shutoff device. The building inspector shall operate all plumbing fixtures, including their faucets and all exterior faucets attached to the house, except where the flow end of the faucet is connected to an appliance. The building inspector is not required to: State the effectiveness of anti-siphon devices; Determine whether water supply and waste disposal systems are public or private; Operate automatic safety controls; Operate any valve except water closet flush valves, fixture faucets, and hose faucets; Observe: Water conditioning systems; Fire and lawn sprinkler systems; On-site water supply quantity and quality; On-site waste disposal systems; Foundation irrigation systems; Spas, except as to functional flow and functional drainage; Swimming pools; Solar water heating equipment; or Observe the system for proper sizing, design, or use of proper materials. IN NI NP RR 4.0 PLUMBING DRAIN, WASTE AND VENT SYSTEMS 4.1 PLUMBING WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES 4.2 HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS 4.3 MAIN WATER SHUT-OFF DEVICE (Describe location) FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, 4.4 venting, supports, leaks) 4.5 MAIN FUEL SHUT OFF (Describe Location) IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace IN NI NP RR Styles & Materials Water Source: Public Water Filters: None Plumbing Water Supply (into building): Lead Hose Plumbing Water Distribution (inside building): Galvanized Washer Drain Size: None Plumbing Waste: Cast iron Water Heater Power Source: Gas (quick recovery) Water Heater Capacity: 40 Gallon (1-2 people) Water Heater Manufacturer: GE Water Heater Location: Basement Concealed hallway panel Comments: 4.0 House catch basin needs cleaning and minor masonry repair. Item 1(Picture) 4.0 Item 1(Picture) House catch basin needs cleaning and minor masonry repair. Page 23 of 35
4.1 Toilet missing in lower level. Item 1(Picture) Water service has been shut off to entire building. Item 2(Picture) Water piping and mixer valve is missing. Item 3(Picture) Kitchen sink and cabinets missing. Item 4(Picture) 4.1 Item 1(Picture) Toilet missing in lower level. 4.1 Item 2(Picture) Water service has been shut off to entire building. 4.1 Item 3(Picture) Water piping and mixer valve is missing. 4.1 Item 4(Picture) Kitchen sink and cabinets missing. Page 24 of 35
4.2 The T&P (Test and Pressure) valve on water heater needs a 3/4 threaded pipe to extend within 6 inches of floor for safety. (PVC is not approved for hot water use). I recommend repair by a qualified person.item 1(Picture) Item 2(Picture) 4.2 Item 2(Picture) 4.2 Item 1(Picture) 4.3 I could not locate the main shut-off for water? Please ask the current owners for the location. Otherwise, you will need to use a water key at the street meter or have a plumber install one. 4.4 Gas service is shut off and could not be checked. 4.5 Gas shut off valves are located on the left side of the meter. Item 1(Picture) Note gas service was shut off at time of inspection. 4.5 Item 1(Picture) Gas shut off valves are located on the left side of the meter. The plumbing in the building was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. Washing machine drain line for example cannot be checked for leaks or the ability to handle the volume during drain cycle. Older homes with galvanized supply lines or cast iron drain lines can be obstructed and barely working during an inspection but then fails under heavy use. If the water is turned off or not used for periods of time (like a vacant building waiting for closing) rust or deposits within the pipes can further clog the piping system. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. Page 25 of 35
5. Garage IN NI NP RR 5.0 GARAGE CEILINGS 5.1 GARAGE WALLS (INCLUDING FIREWALL SEPARATION) 5.2 GARAGE FLOOR 5.3 GARAGE DOOR (S) 5.4 ROOF 5.5 Garage structure IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace Styles & Materials Garage Door Type: One manual Garage Door Material: Metal Auto-opener Manufacturer: UNKNOWN IN NI NP RR Comments: 5.4 Garage roof is in poor condition and needs to be replaced. Item 1(Picture) 5.4 Item 1(Picture) Garage roof is in poor condition and needs to be replaced. 5.5 Garage structure appears to be sound. But is in need of roofing,siding, patio door and entrance door. Garage was boarded up at time of inspection and interior could not be seen. Item 1(Picture) 5.5 Item 1(Picture) Garage structure appears to be sound. But is in need of roofing,siding, patio door and entrance door. Garage was boarded up at time of inspection and interior could not be seen. Page 26 of 35
6(A). 1st Floor The building inspector shall observe permanently installed heating and cooling systems including: Heating equipment; Cooling Equipment that is central to building; Normal operating controls; Automatic safety controls; Chimneys, flues, and vents, where readily visible; Solid fuel heating devices; Heat distribution systems including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units, convectors; and the presence of an installed heat source in each room. The building inspector shall describe: Energy source; and Heating equipment and distribution type. The building inspector shall operate the systems using normal operating controls. The building inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The building inspector is not required to: Operate heating systems when weather conditions or other circumstances may cause equipment damage; Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe: The interior of flues; Fireplace insert flue connections; Humidifiers; Electronic air filters; or The uniformity or adequacy of heat supply to the various rooms. IN NI NP RR 6.0.A CEILINGS 6.1.A WALLS 6.2.A FLOORS 6.3.A DOORS (REPRESENTATIVE NUMBER) 6.4.A WINDOWS (REPRESENTATIVE NUMBER) 6.5.A COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS 6.6.A PLUMBING SUPPLY, FIXTURES IN THIS UNIT 6.7.A PLUMBING DRAIN, WASTE AND VENT SYSTEMS IN THIS UNIT 6.8.A OUTLETS AND WALL SWITCHES 6.9.A STEPS, STAIRWAYS, BALCONIES AND RAILINGS 6.10.A HEATING EQUIPMENT 6.11.A PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM 6.12.A CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water heaters or heat systems) 6.13.A SERVICE ENTRANCE CONDUCTORS SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, 6.14.A MAIN AND DISTRIBUTION PANELS BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND 6.15.A COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF 6.16.A INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE 6.17.A LOCATION OF MAIN AND DISTRIBUTION PANELS 6.18.A SMOKE DETECTORS 6.19.A CARBON MONOXIDE DETECTORS IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace Styles & Materials Ceiling Materials: Plaster Wall Material: Plaster Floor Covering(s): Hardwood T&G Tile Interior Doors: Wood Window Types: Double-hung Thermal/Insulated Heat Type: Forced Air Energy Source: Natural gas Number of Heat Systems (excluding wood): One Heat System Brand: AMERICAN STANDARD Ductwork: Non-insulated Filter Type: Disposable Electrical Service Conductors: Overhead service 220 volts Panel capacity: 100 AMP Panel Type: Circuit breakers Branch wire 15 and 20 AMP: Copper Wiring Methods: Conduit Flexible greenfield conduit IN NI NP RR Comments: Page 27 of 35
6.1.A Apartment has many holes in the walls. Item 1(Picture) Item 2(Picture) 6.1.A Item 1(Picture) Apartment has many holes in the walls. 6.1.A Item 2(Picture) 6.3.A Rear door is off hinges. Item 1(Picture) 6.3.A Item 1(Picture) Rear door is off hinges. 6.5.A Cabinets missing. 6.6.A Water supply has been removed. 6.7.A Drains are intact. Page 28 of 35
6.8.A Electrical receptacles within six feet of a sink must be changed to a gfci type. Item 1(Picture) Item 2(Picture) Several receptacles in apartment tested with reverse polarity. Item 3(Picture) Item 4(Picture) 6.8.A Item 1(Picture) Electrical receptacles within six feet of a sink must be changed to a gfci type. 6.8.A Item 2(Picture) 6.8.A Item 3(Picture) Several receptacles in apartment 6.8.A Item 4(Picture) tested with reverse polarity. Page 29 of 35
6.10.A Gas service off in building and furnace could not be tested. Note furnace is very old and is past economical life. Item 1(Picture) 6.10.A Item 1(Picture) Gas service off in building and furnace could not be tested. Note furnace is very old and is past economical life.ii 6.11.A Heat vents are in all rooms. 6.12.A Flue pipe is open in basement from removed space heater. 6.13.A Electrical service cable is not attached to porch wall. Item 1(Picture) 6.13.A Item 1(Picture) Electrical service cable is not attached to porch wall. 6.14.A No defects found in electrical panels. 6.15.A Wire size is correct. Page 30 of 35
6.16.A Exposed wiring should be removed or made safe. Item 1(Picture) Item 2(Picture) All electrical receptacles within 6 feet of a sink must be changed to a gfci type. 6.16.A Item 1(Picture) Exposed wiring should be removed or made safe. 6.16.A Item 2(Picture) 6.17.A Electrical panels are located n the North end of basement. The heating and cooling system of this building was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensed heat contractor would discover. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. Page 31 of 35
6(B). 2nd floor The building inspector shall observe permanently installed heating and cooling systems including: Heating equipment; Cooling Equipment that is central to building; Normal operating controls; Automatic safety controls; Chimneys, flues, and vents, where readily visible; Solid fuel heating devices; Heat distribution systems including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units, convectors; and the presence of an installed heat source in each room. The building inspector shall describe: Energy source; and Heating equipment and distribution type. The building inspector shall operate the systems using normal operating controls. The building inspector shall open readily openable access panels provided by the manufacturer or installer for routine homeowner maintenance. The building inspector is not required to: Operate heating systems when weather conditions or other circumstances may cause equipment damage; Operate automatic safety controls; Ignite or extinguish solid fuel fires; or Observe: The interior of flues; Fireplace insert flue connections; Humidifiers; Electronic air filters; or The uniformity or adequacy of heat supply to the various rooms. IN NI NP RR 6.0.B CEILINGS 6.1.B WALLS 6.2.B FLOORS 6.3.B DOORS (REPRESENTATIVE NUMBER) 6.4.B WINDOWS (REPRESENTATIVE NUMBER) 6.5.B COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS 6.6.B PLUMBING SUPPLY, FIXTURES IN THIS UNIT 6.7.B PLUMBING DRAIN, WASTE AND VENT SYSTEMS IN THIS UNIT 6.8.B OUTLETS AND WALL SWITCHES 6.9.B STEPS, STAIRWAYS, BALCONIES AND RAILINGS 6.10.B HEATING EQUIPMENT 6.11.B PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM 6.12.B CHIMNEYS, FLUES AND VENTS (for fireplaces, gas water heaters or heat systems) 6.13.B SERVICE ENTRANCE CONDUCTORS SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, 6.14.B MAIN AND DISTRIBUTION PANELS BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND 6.15.B COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF 6.16.B INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE 6.17.B SMOKE DETECTORS 6.18.B CARBON MONOXIDE DETECTORS IN= Inspected, NI= Not Inspected, NP= Not Present, RR= Repair or Replace Styles & Materials Ceiling Materials: Plaster Wall Material: Plaster Floor Covering(s): Hardwood T&G Tile Interior Doors: Wood Window Types: Double-hung Thermal/Insulated Heat Type: Forced Air Energy Source: Natural gas Number of Heat Systems (excluding wood): One Heat System Brand: AGED Fedders Ductwork: Non-insulated Filter Type: Disposable Electrical Service Conductors: Overhead service 220 volts Panel capacity: 100 AMP Panel Type: Circuit breakers Branch wire 15 and 20 AMP: Copper Wiring Methods: Conduit Flexible greenfield conduit IN NI NP RR Comments: 6.4.B Some windows have been removed and are boarded up. Page 32 of 35
6.8.B Many electrical receptacles do not have a ground. Item 1(Picture) 6.8.B Item 1(Picture) Many electrical receptacles do not have a ground. 6.9.B Missing hand rail. Item 1(Picture) 6.9.B Item 1(Picture) Missing hand rail. 6.10.B Furnace not tested due to gas shut of in building. Item 1(Picture) 6.10.B Item 1(Picture) Furnace not tested due to gas shut of in building. Page 33 of 35
6.14.B No defects found. 6.16.B Updating of electrical receptacles is recommended. The heating and cooling system of this building was inspected and reported on with the above information. While the inspector makes every effort to find all areas of concern, some areas can go unnoticed. The inspection is not meant to be technically exhaustive. The inspection does not involve removal and inspection behind service door or dismantling that would otherwise reveal something only a licensed heat contractor would discover. Please be aware that the inspector has your best interest in mind. Any repair items mentioned in this report should be considered before purchase. It is recommended that qualified contractors be used in your further inspection or repair issues as it relates to the comments in this inspection report. Page 34 of 35
INVOICE 6334 W. Grace st Chicago Illinois 60634 1-773-454-6700 Inspected By: Joseph Poelsterl Inspection Date: 12/23/2013 Report ID: Customer Info: Inspection Property: Mr. Happy 2532 W. Lyndale St. Chicago Il 60647 Customer's Real Estate Professional: Glen Tomlinson Century 21 United II Inspection Fee: Service Multi-Family Price 450.00 Amount 1 Sub-Total 450.00 Tax $0.00 Total Price $450.00 Payment Method: Check Payment Status: Paid At Time Of Inspection Note: Page 35 of 35