Cooling Channel Optimization



Similar documents
Intelligent Mould Flow Monitoring

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Rackmount Intelligent Pressure Scanners

Designed for multi-injector endurance testing, the

FILLING AND PURGING THE SYSTEM

Current Monitoring Kit QUICK START GUIDE

The Universal DAQ Device. Connect and measure immediately!

Current Monitoring Kit

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

REGTRONIC OPERATING INSTRUCTIONS

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

API Marine. BMS Presentation. Ballast Measurement Systems

Process Alarm Solutions

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

PUMP AND MOTOR DIVISION

AIR QUALITY SURVEILLANCE BRANCH ACCEPTANCE TEST PROCEDURE (ATP) FOR. Teledyne Advanced Pollution Instruments Model 400 E Ozone Analyzer AQSB ATP 002

NEW. EVEN MORE data acquisition and test stand automation

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Network Video Recorder Quick Operation Guide

How To Control A Medical Device With A Pc System

SNMP Web Management. User s Manual For SNMP Web Card/Box

COMBIMASS. Technical Data COMBIMASS eco-bio +

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Help. Help Software Tutorial. Building a load sizing project with an ME Series Humidifier

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

RGC-IR Remote Gas Calibrator for IR400

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Qingdao Guihe Measurement&Control Technology Co., Ltd. Automatic Tank Gauging System, Magnetostrictive Diesel fuel tank level gauge

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500 Series Stand-Alone, Low-Cost Data Loggers

S300 Series Dust Monitors

PRODUCT PROFILE FEATURES

Product Description. Model VM 500 series [ VM508/VM508E ] Water Alarm. Telephone/Pager Alert Calls. Power Alarm. Maximum Number of Sensors

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES


In-Line Electronic Flow Switches

TMS TANK MANAGEMENT SYSTEM

Refrigerant Charging Unit ICOGD. 020AH1000 Operating Manual. FR İ-COLD Rev. 00

Draining and filling cooling system

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.

Electronic Flow Switches

WAMLocal. Wireless Asset Monitoring - Local Food Safety Software. Software Installation and User Guide BA/WAM-L-F

Digital Single Axis Controller

CPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!

F453. TiF453. User guide 10/11-01 PC

MINIMAT-EC-Servo Screwdriver Spindles

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

How to use the OMEGALOG software with the OM-SQ2010/SQ2020/SQ2040 Data Loggers.

Before You Start 1 Overview 2 Supported Devices 4 Public (User LAN) and Private (APC LAN) Networks 5. Initial Configuration Requirements 6

Ecotech Air Quality Monitoring Data Acquisition System

SMS GSM Alarm Messenger

Overview. 1. GPS data tracking via GSM SMS / GPRS. 2. GPS data logging in internal memory. 3. Alarm alert via GSM SMS / Dialing / GPRS

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Ammonia Detection System Codes and Design Specifications

The Best Technology for the Application. Educating the Specifier on Medical Air & Medical Vacuum Systems

Mono-Block II Installation & Operation Manual

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

High voltage tester HA 1800 Table-top device

Power consumption (kw)

Uninterruptible Power Supply

Reliability Accuracy Performance

Signal Manager Installation and Operation Manual

Liebert COMPREHENSIVE DETECTION OF WATER BASED LEAKS IN CRITICAL SPACES. Liebert Liqui-tect. M o n i t o r i n g S o l u t i o n s

Positioner Versions. Remote feed-back. Local display, Electric / Hydraulic. Remote feed-back Electric / Hydraulic. Embedded Control Positioner

Cat Electronic Technician 2015C v1.0 Product Status Report 2/20/2016 4:34 PM

Melting Point Apparatus

Refrigeration Compressed Air Dryer Buran Ultrapulse

Statement of Work. 3.0 Details of Service Pre Start-up Cooling Start-up Service. Installation Service. Table of Contents. 1.0 Executive Summary

KNC Model 3666 Automatic Pressure Calibration System

EN54-16 Voice Alarm System PRODUCT DATASHEETS

Remote Level Monitoring Unit

Automatic tank gauge system ATGs for petrol stations, diesel fuel tank level gauge, tank gauging system, magnetostrictive probe

WHOLESALE DIRECT INC WEST 65TH STREET

Transmitter Interface Program

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

PACE Modular Pressure Controller

in widespread use with Simplex sister Company, Simplex Onsite, providing nationwide load bank rentals.

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

High Power Programmable DC Power Supplies PVS Series

MEASURE AND CONTROL INVENTORY MANAGEMENT CONSOLE (IMC) Console for stand alone use Console with PC interface, software & USB cable

Thermal Mass Flow Meters and Controllers for Gases

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

PowerGem Pro Uninterruptible Power Supply

K-Type Thermocouple Sensor User s Guide

Gas Custody Transfer Calibration

The Breather Box. High Performance Grade-D Breathing Air Filtration system. BB50-cO

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

EDK 350 (868 MHz) EDK 350U (902 MHz) EnOcean Developer Kit

Autos Limited Ghana Vehicle Tracking Business Proposal

In-Line Electronic Flow Switches

Medical Air Systems: Scroll

STERILIZERS, LABORATORY DRYING OVENS

ATB50v1 GPRS / GPS Based Fleet Management Terminal. Datasheet

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

이 기기는 업무용 급 으로 전자파적합등록을 한 기기이오니 판매자 또는 사용자는 이점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다

TICS - Integrated Control Strategy TICS - Total Integrated Control Strategy Mid Range System

Transcription:

Mouldflo Test Rig

Cooling Channel Optimization Plug and Play Mould pre-set for production For the first time Mouldflo offers Mouldmakers a unique way to configurate the cooling circuits with full Benchmark Mouldmakers must often supply new moulds to the customer complete with a report of operating parameters which should include data relating to the cooling circuits in the mould. Now mouldmakers can easily connect the Mouldflo Test Rig to the mould as part of the benchmarking process. 2 Mouldflo Test Rig

Mould Maintenance Moulds must be maintained regulary to remove scale and rust and ensure maximum productivity Scale build-up Mould cooling curcuits are exposed to scale build-up, which will reduce flow capacity dramatically and also act as an insulator causing moulding problems due to increasing temperatures. Eventually the cooling channels will block and eventually stop the production. Flow, temperature and pressure test With the Mouldflo Test Rig, the cooling channels can be analysed and tested. The flow and pressure can be controlled exactly to simulate the production setup. All details displayed on the screen: Flow Temperature Pressure Inlet Pressure Outlet Integrated Pump The internal dynamic pump will give a calibrated flow and pressure, fully defined and controlled on the Touch Screen. Dynamic control of: Flow volume Back pressure/pump pressure Mouldflo Test Rig 3

Measurement Report After maintenance you can generate full documentation reports, certifying that all flow and pressure values are regained. Following data can be recorded: Flow volume/capacity Pressure loss through the Mould Pressure Leak Test Water purge Drain the mould in seconds After testing and certifying the mould, a convenient feature allows you to purge the water out of all channels, simply by pushing the empty system function. 4 Mouldflo Test Rig

Calibration Mouldflo Certified Calibration unit for perfect results The Mouldflo calibration unit, makes calibration of the Mouldflo sensors, a simple task. The unit includes a certified flow sensor which ensures reliable test data.. The Calibration unit is made in a protective flight case design which makes it mobile, flexible and userfriendly. Mouldflo Test Rig 5

Hardware Sensors The Mouldflo Manifold is equipped with very compact sensors that are capable of reading both flow and temperature. The sensor is based upon the vortex flow measurement principle which uses a bluff body in the middle of the flow path to create small eddy currents (vortices) and the pressure of this current is measured to determine the flow through a given cross sectional area. The sensors have no moving parts; this, combined with a large flow path, make it ideally suited to mould cooling even when using heavily contaminated water. The sensors are integrated directly into the manifold keeping size to an absolute minimum; the manifold has been designed to create a fixed linear flow path that is essential for accurate flow measurement. The sensors are available with two flow ranges to suit the application and are held in place with a simple clip which can be easily replaced making maintenance very simple. 6 Mouldflo Test Rig

Technical specifications Manifold Manifold feed 1-1/2 BSP Manifold ports 1/2 BSP Number of ports 4/8/12 Standard (other sizes on request) Regulation Colour coded ball valves per circuit (optional) Manifold connection Customer specified Hasco/DME/Staubli (optional) Operating temperature (max) 0-90ºC Operating pressure (max) 10 bar Temperature sensing Per circuit (return) Flow sensing Per circuit (return) Temperature sensing main inlet Yes (optional) Power Supply 12-24 VDC Flow sensor Sensor type Vortex Range (flow) 2-40 litres/min or 1-15 litres/min Accuracy (flow) 1.5% fs Range (temperature) 0-90ºC Resolution (temperature) 0.5ºC Accuracy (temperature) +/- 1,5% fs Sensor signal 0,35 3,5 V Output signal Voltage Response time < 1 s Power supply 5 VDC Seal EPDM Burst pressure 18 bar (40ºC) Connection Quick connect - plug and play Control Display Control Comunication ports Comunication system Protocols Storage (log and settings) Machine Control integration Remote Access via internet/network Number of zones (flow and temperature) Number of manifolds Display units (flow) Display units (temperature) Warning limits Alarm limits Alarm output Marker input Idle mode input Power supply 15.6 touch screen (optional) Microprocessor based / computer based (optional) Ethernet / USB ASCII(USB) / HTML / SSH (optional) / VNC (optional) USB Serial / TCP/IP Internal (optional) / USB (optional) Yes (optional) Yes (optional) Max 12 Zones / manifold (expandable) Multiple (plug and play) Litres / gallons switchable / RAW (optional) ºC / ºF switchable / RAW (optional) 10% of alarm limits (optional) User definable per zone (optional) Potential free output warning / alarm Potential free Potential free 12-24 VDC Pump and Tank Pump Capacity Up to 120 l/m Pump Pressure 0-6 Bar Power supply 380V., 50Hz, 2500W Tank Capacity 75 l. Mouldflo Test Rig 7

Mouldflo is part of the Mouldpro Group Baltorpbakken 10 DK-2750 Ballerup Denmark Phone: +45 7020 8484 Fax: +45 7020 8483 www.toolnet.dk