PRODUCT CATALOG 2013/2014 Dust measuring devices New standards in dust measuring technologies, applications, and measuring devices
B SICK online Product description www.mysick.com select and order online C im miniature Search online quickly and safely with the SICK Finders Product Applications Literature Service Connection diagram Accessories Spare part Software D Inductive proximity sensors space-saving miniature threaded inductive sensors Product Finder: We can help you to quickly target the product that best matches your application. Applications Finder: Select the application description on the basis of the challenge posed, industrial sector, or product group. E Literature Finder: Go directly to Product the operating description instructions, technical information, and other literature on all aspects of SICK products. F At a glance Efficiency with the e-commerce tools from SICK Inductive proximity sensors Cylindrical threaded housing Find out prices and availability: Determine the price and possible delivery date of your desired product simply and quickly at any time. Request or view a quote: You can have a quote generated online here. Every quote is confirmed to you via e-mail. Order online: You can go through the ordering process in just a few steps. Product family o Navigation in the PDF document Links to online ordering system your benefits At a glance your benefits Inductive proximity sensors Cylindrical threaded housing By bookmarks and tables of contents Additional information Table of contents switching output Connection Connection diagram A By links, QR codes and part numbers type Part no. Sn H By page references Additional information B C Proximity sensors sick D E Subjec switching output Connection- Connection my product F diagram type Part no. - C-110 --C-118 --C-124 --C-132 G Proximity sensors sick 8014939/2012-11-28
Product selection Dust measuring devices Overview of dust measuring devices = ideal match for requirement. = meets requirement. Product Measuring principle Certificates Measuring conditions Measuring conditions Test functions Duct diameter Page Scattered light forward Scattered light backward Transmittance Gravimetric analysis EN 15267 1) EN 13284 MCERTS U.S. EPA GOST Ex, ATEX Low concentrations (< 200 mg/m 3 ) High concentrations (> 200 mg/m 3 ) Humid gas Aggressive gas Non-homogeneous medium density Inner duct pressure ( 50... +30 hpa) Max. process temperature (+600 C) Max. process temperature (+400 C) Max. process temperature (+300 C) Max. process temperature (+220 C) Automatic control cycle Manual linearity check Contamination check 0.5 1 3 5 8 12 Scattered light dust measuring devices DUSTHUNTER SB30 500 mm D-38 DUSTHUNTER SB50 500 mm D-46 DUSTHUNTER SB100 500 mm D-54 DUSTHUNTER SF100 0.5... 3 m 2.5... 6 m D-62 DUSTHUNTER SP100 2) 3) 250 mm D-72 FW101 Ex 4) 2) 250 mm D-82 FW102 4) 150 mm D-90 FWE200 1) 5) 400 mm D-98 FWE200DH 5) 400 mm D-104 Transmittance dust measuring devices DUSTHUNTER C200 0.5... 3 m 2.5... 8 m E-114 0.5... 2.5 m DUSTHUNTER T50 2... 5 m E-126 4... 8 m 0.5... 2.5 m DUSTHUNTER T100 2... 5 m E-134 4... 12 m 0.5... 2.5 m DUSTHUNTER T200 2... 5 m E-144 4... 12 m FW300 Ex 0.5... 2 m 1. 5... 8 m E-154 Gravimetric dust measuring devices GRAVIMAT SHC500 150 mm F-166 1) For equipment requiring approval to: (2001/80/EC, 2000/76/EC) and plants of 27 th Federal Implementation Control Act 2) Inner duct pressure: up to 10 kpa 3) Up to 200 kpa on request 4) TÜV-tested for equipment requiring approval to TA Clean Air Act (TA Luft) and 27 th Federal Implementation Control Act 5 ) Inner duct pressure: 20 +20 hpa
Table of contents General information About SICK A Technologies and services B Typical applications C Scattered light dust measuring devices DUSTHUNTER SB30, DUSTHUNTER SB50, DUSTHUNTER SB100, DUSTHUNTER SF100, DUSTHUNTER SP100, FW101 Ex, FW102, FWE200, FWE200DH Transmittance dust measuring devices DUSTHUNTER C200, DUSTHUNTER T50, DUSTHUNTER T100, DUSTHUNTER T200, FW300 Ex D E Gravimetric dust measurement devices SHC500 F
Company A We deliver "Sensor Intelligence." SICK sensor solutions for industrial automation are the result of exceptional dedication and experience. From development all the way to service: The people at SICK are committed to investing all their expertise in providing with the very best sensors and system solutions possible. A company with a culture of success Over 6,000 people are on staff, with products and services available to help SICK sensor technology users increase their productivity and reduce their costs. Founded in 1946 and headquartered in Waldkirch, Germany, SICK is a global sensor specialist with more than 40 subsidiaries and representations worldwide. Our exemplary corporate culture fosters an optimum work-life balance, thus attracting the best employees from all over the world. SICK is one of the best employers we have been among the winners of the prestigious German Great Place to Work award for many years in succession. A-4 Dust Measuring Devices SICK 8016639/2013-09
Company A Innovation for the leading edge SICK sensor systems simplify and optimize processes and allow for sustainable production. SICK operates at many research and development centers all over the world. Co-designed with customers and universities, our innovative sensor products and solutions are made to give a decisive edge. With an impressive track record of innovation, we take the key parameters of modern production to new levels: reliable process control, safety of people and environmental protection. A corporate culture for sustainable excellence SICK is backed by a holistic, homogeneous corporate culture. We are an independent company. And our sensor technology is open to all system environments. The power of innovation has made SICK one of the technology and market leaders sensor technology that is successful in the long term. 8016639/2013-09 Dust Measuring Devices SICK A-5
Industries A "Sensor Intelligence." for all requirements SICK is a renowned expert in many industries, and is entirely familiar with the critical challenges they face. While speed, accuracy and availability take center stage in all industries, technical implementations vary greatly. SICK puts its vast experience to use to provide with precisely the solution you need. For applications worldwide Hundreds of thousands of installations and applications go to prove that SICK knows the different industries and their processes inside out. This tradition of uncompromising expertise is ongoing: As we move into the future, we will continue to design, implement and optimize customized solutions in our application centers in Europe, Asia and North America. You can count on SICK as a reliable supplier and development partner. A-6 Dust Measuring Devices SICK 8016639/2013-09
Industries A For your specific industry With a track record of proven expertise in a great variety of industries, SICK has taken quality and productivity to new heights. The automotive, pharmaceutical, electronics and solar industries are just a few examples of sectors that benefit from our know-how. In addition to increasing speed and improving traceability in warehouses and distribution centers, SICK solutions provide accident protection for automated guided vehicles. SICK system solutions for analysis and flow measurement of gases and liquids enable environmental protection and sustainability in, for example, energy production, cement production or waste incineration plants. For performance across the board SICK provides the right technology to respond to the tasks involved in industrial automation: measuring, detecting, monitoring and controlling, protecting, networking and integrating, identifying, positioning. Our development and industry experts continually create groundbreaking innovations to solve these tasks. www.sick.com/industries 8016639/2013-09 Dust Measuring Devices SICK A-7
SICK LifeTime Services A For safety and productivity: SICK LifeTime Services SICK LifeTime Services is a comprehensive set of high-quality services provided to support the entire life cycle of products and applications from plant walk-through all the way to upgrades. These services increase the safety of people, boost the productivity of machines and serve as the basis for our customers sustainable business success. The benefit of SICK services Each of our products and solutions is accompanied by a comprehensive range of services tuned precisely to the requirements of the product or solution along its entire life cycle. Backed by extensive industry expertise and more than 60 years of experience, LifeTime Services stand for maximum availability and an exceptional service life of our products and solutions. A-8 Dust Measuring Devices SICK 8016639/2013-09
SICK LifeTime Services Consulting & Design Plant walk-through Risk assessment Safety concept Feasibility studies Software and hardware design Verification & Optimization Inspection Maintenance Barcode checks Accident investigation Stoptime measurement Machine safety inspection Training & Education User training Seminars WebTraining A Product & System Support Upgrade & Retrofits Commissioning Exchange units and repairs Remote support Hotline Machine conversion Sensor upgrades Retrofitting of technology www.sick.com/services 8016639/2013-09 Dust Measuring Devices SICK A-9
Product overview Product overview A Versatile product range for industrial automation From the simple acquisition task to the key sensor technology in a complex production process: With every product from its broad portfolio, SICK offers a sensor solution that best combines cost effectiveness and safety. www.sick.com/products Photoelectric sensors Miniature photoelectric sensors Small photoelectric sensors Compact photoelectric sensors Fiber-optic sensors and fibers Cylindrical photoelectric sensors MutliTask photoelectric sensors Proximity sensors Inductive proximity sensors Capacitive proximity sensors Magnetic proximity sensors Magnetic cylinder sensors Analog positioning sensors Sensors for T-slot cylinders Sensors for C-slot cylinders Sensor adapters for other cylinder types Identification solutions Bar code scanners Image-based code readers Hand-held scanners RFID A-10 Dust Measuring Devices SICK 8016639/2013-09
Product overview Detection and ranging solutions Laser measurement technology A System solutions Volume measurement systems Code reading systems Dimension weighing scanning systems Vision systems Fluid sensors Level sensors Pressure sensors Flow sensors Temperature sensors Registration sensors Contrast sensors Color sensors Luminescence sensors Fork sensors Array sensors Register sensors Markless sensors Distance sensors Short range distance sensors (displacement) Mid range distance sensors Long range distance sensors Linear measurement sensors Ultrasonic sensors Double sheet detector Optical data transmission Position finders 8016639/2013-09 Dust Measuring Devices SICK A-11
Product overview A Automation light grids Advanced automation light grids Standard automation light grids Smart light grids Vision Vision sensors Smart cameras 3D cameras Opto-electronic protective devices Safety laser scanners Safety camera systems Safety light curtains Multiple light beam safety devices Single-beam photoelectric safety switches Mirror and device columns Upgrade kits Safety switches Electro-mechanical safety switches Non-contact safety switches Safety command devices sens:control safe control solutions Safety relays Safety controllers Network solutions A-12 Dust Measuring Devices SICK 8016639/2013-09
Product overview Motor feedback systems Interfaces: incremental, HIPERFACE and HIPERFACE DSL Safety motor feedback systems Rotary and linear motor feedback systems for asynchronous, synchronous motors and linear motors A Encoders Absolute encoders Incremental encoders Linear encoders Wire draw encoders Analyzers and systems Gas analyzers Dust measuring devices Analyzer systems Liquid analyzers Data acquisition systems Tunnel sensors Gas flow measuring devices Gas flow meters Mass flow meters Volume flow measuring devices Software Safexpert safety software 8016639/2013-09 Dust Measuring Devices SICK A-13
Technologies and services Scattered light Dust dust measuring devices B Why is measuring dust so important? The detection and accurate measurement of dust and particle emissions is very important for the longterm sustainable protection of the environment. Even today, dust particles in particular those caused by industrial plants can have a significant impact on humans and the natural environment. As a leading manufacturer of innovative state-of-the-art dust measuring devices with decades of experience, SICK is making a valuable contribution in this regard. With a comprehensive portfolio ranging from continuous and discontinuous measurement principles through to dust measurements in wet flue gases, SICK is able to offer the right solution even for the most difficult of measuring tasks. Emissions Immissions Emissions in terms of the environment refer to the discharge, transmission, or disposal of disrupting factors into the environment. Emissions are comprised of toxic, harmful or environmentally hazardous chemical substances as well as pollutants of all kinds, irritants, and allergens. Each emission results from an immission (discharge). Immissions are pollutive air, water, or soil contamination phenomena at the site of impact resulting from emissions. The environment can be protected primarily by way of limiting emissions. Statutory limitations always represent interference into the freedom of action of the generating industry. For this reason, in many countries emissions may not be limited "for their own sake", but only in accordance with the principle of proportionality according to their damaging effect on the environment and human health. B-14 Dust measuring devices SICK 8016639/2013-09
Scattered Dust measuring light dust devices measuring devices Technologies and services Particles and dusts and how they affect us Dust is made up of visible and invisible floating and deposited particles of solid matter. Dusts are a mixture of particles in all manner of forms. Their size and chemical composition determines the nature of dusts. Where effects on health are concerned, the factors that are of primary relevance are grain size, geometrical form, and pollutants adhering to the surface. Based on the size of its particles, dust can be categorized as coarse (aerodynamic diameter > 10 µm) and fine (aerodynamic diameter < 10 µm). Types of particle B Solid particles in the air are broadly categorized as soot, dust, and smoke. Soot essentially comprises carbon, caused by incomplete combustion processes. Dusts are very finely dispersed solid particles in the air resulting from mechanical processes or swirling. Smoke consists of very finely dispersed solid particles in the air resulting from chemical or thermal processes. Asbestos dust is a generic term for various naturally occurring fibrous silicate materials. Today, it is universally acknowledged that asbestos poses a health risk. Therefore, it is all the more important that these dusts are not allowed to get into the environment at all. This is assured by reliable measurements being taken around the clock. Carbon dust is atomized soft or hard coal. This dust occurs during the decomposition of coal deposits or the dust is specifically produced in grinding plants. Coal dust has a maximum particle diameter of 0.5 mm. House dust is the generic term for particulate and fibrous immissions in enclosed spaces. It is a mixture of highly diverse inorganic and organic materials including fibers, fluff, hair, pollutants, grains of rock, road grime, atmospheric dust, cosmic dust, and finally fine dust. Impact on measurement technology In order to be able to measure dust and particle concentrations reliably and accurately, the following criteria must be taken into account (see also page B-17) Specification of the measuring site for representative measurement results Measuring distances and flow conditions at the measuring site Very low through very high dust concentrations Gas composition in the measured medium from ambient air through aggressive medium Particle properties such as size or grain size, shape, color, material, density, or specific features such as abrasive or sticky Ambient conditions such as ambient temperature and air composition, e.g., saline or fine dust 8016639/2013-09 Dust measuring devices SICK B-15
Technologies and services Scattered light Dust dust measuring devices B Why measure emissions? Action is necessary due to global warming caused by the greenhouse effect. One important measure is to sustainable measure the emission of climate-relevant gases in order to attain an important reference value for the efficient reduction of greenhouse gas emissions. Moreover, locally the hazardous impact of smog, ozone and dust play a decisive role. In many countries there is a legislative basis for a sustained environmentally compatible reduction of greenhouse gas emissions as well as laws and directives relating to the emission of pollutants. These regulations include specifications for technology and modes of operation for systems as well as specifications detailing pollutant limits permissible in released clean gas and what measuring technology may be used for purposes of monitoring. Emission limit values These are maximum values for the legally permissible discharge of mass flows or pollutants. In most cases they are specified using specific parameters such as concentration and/ or quantity of emissions which must not be exceeded during one or a number of periods of time. Based on the best available measurement technology, pioneering steps for advanced development of measures and their methods and procedures are obvious for operators. However, these limit values for pollutant emissions are often set "politically". Directives, approval bodies, and elements European and international directives and standards EU directives and TÜV certifications with ordinances governing: Large combustion plants and gas turbines (2001/80/EC) Incarceration of waste (2000/76/EU) Quality standards for automatic measuring systems: EN 14181 Stationary source emissions Quality assurance of automated measuring systems EN 15267 Certification of automated measuring systems EN 13284 Stationary source emissions Determination of low range mass concentration of dust The new industrial emissions directive 2010/75/EU for integrated prevention and reduction of environmental pollution Approval body MCERTS for Great Britain Environmental agency U.S. EPA with the American quality standards (EPA CFR 11 Part 60 and Part 75) Japanese standard JQA Standards organization GOST for GUS standards and regulations Chinese EPA CEP EPA standards for many other countries German directives and standards Federal Immission Control Act (Bundes-Immissionsschutzgesetz, BImschG) Federal Immission Protection Directives (BImschV) 17. BImschV and 30. BImSchV Technical Instructions on Air Quality Control (TA Luft) B-16 Dust measuring devices SICK 8016639/2013-09
Scattered Dust measuring light dust devices measuring devices Technologies and services Best available measurement technology Alongside the selection of the best available technologies, a whole range of influencing factors and requirements must be taken into account if a measuring task is to be completed successfully. The more accurate and more detailed the requirements are identified and defined, the more reliably and cost-effectively the measuring task can be completed. This applies for the entire service life and not just in the context of procurement. SICK is able to show its strengths here with a comprehensive product portfolio, proven measurement technology, and decades of experience gained from many thousands of installations. B Impact on measurement technology In order to be able to measure dust and particle concentrations reliably and accurately, the following criteria must be taken into account: Selection of the measuring site: The determination of the measuring site in the plant is a decisive factor in reliable and representative measurement results. This can have a significant impact on the selected measurement technology and measuring device with its longterm operation. Measuring distance: Does the application involve very small ducts, e.g., with measuring distances of 0.25 m and above, or chimneys with very large diameters of more than 12 m? Flow conditions: What is the nature of the prevailing flow conditions at the measuring site: uniform flows or turbulent flows with concentrations > 10 g/m 3? Concentrations: Do very low particle concentrations of < 1 mg/m 3 or medium to very high concentrations have to be measured? Gas composition: What is the nature of the gas composition in the measured medium from ambient air through aggressive medium? Particle properties: What is the nature of the particle properties? What is the prevailing particle size or grain size, shape, color, material, or density? Are the particles abrasive or sticky? Ambient conditions: What are the ambient conditions on site? How high is the ambient temperature? What is the nature of the composition of the air, e.g., saline or fine dust? How is dust measured? There are two fundamental measuring procedures: Continuous dust measurement, whereby optical, electrical, or other measurement principles are applied and measurements are taken continuously. These measuring procedures are the preferred choice for continuous measurements over long periods around the clock. Discontinuous dust measurement with the gravimetric measurement principle. Gravimetric determination of dust concentration is the proven and accepted reference method for the calibration of all continuous measuring systems. 8016639/2013-09 Dust measuring devices SICK B-17
Technologies and services Scattered light Dust dust measuring devices Continuous dust measurement principles Transmissiometry L B Light is transmitted through a mixture of gas and particles. The intensity of the light is attenuated by the particles. The more particles there are in the light beam, the more significant the attenuation of the light will be. SICK transmittance measuring devices are designed so that the light beam travels the measuring distance twice. The reflector opposite the sender reflects the light to a highly sensitive receiver, which accurately compares the intensity of the received (attenuated) light with that of the transmitted (unattenuated) light. Transmittance can be accurately determind based on the difference between the two values. The dust concentration in mg/m 3 is determined by converting the transmittance values into extinction and by taking a gravimetric comparison measurement. Sender/receiver unit Determination of dust concentration I Transmittance T = I 0 I Opacity O = 1 T = 1 I 0 1 Extinction E = log = lg (T) T Lambert-Beer law I = I 0 e k L c Dust concentration 100 0 ln (T) c = k L ln (T) = 2.3 log (T) c = 2.3 E k L I 0 I T = Transmittance = Translucence I 0 = Emitted light Reflector I = Received light O = Opacity = Light attenuation E = Extinction = Logarithmic measure of light attenuation Lambert-Beer law = Dependence between attenuated light intensity l and dust concentration c over measuring distance L k = Extinction coefficient, dependent on grain size, shape, and surface, as well as light wavelength L = 2x measuring distance c = Concentration Dust concentration [mg/m 3 ] 500 The dust concentration is proportionate to the extinction. This measurement principle is most frequently used for medium to high dust concentrations. Opacity [%] 80 20 60 40 20 Transmittance [%] 40 60 80 400 300 200 100 10 µm 5 µm 2 µm 0 100 0 0.1 1 Extinction 2 0 0 0,02 0,04 0,06 0,08 0,10 0,12 0,14 0,16 Extinction Dependence of the dust concentration measured on measuring distance and particle size Smallest measuring range Dust concentration [mg/m 3 ] 250 200 150 Largest measuring range Dust concentration [mg/m 3 ] 10 000 9 000 8 000 7 000 6 000 5 000 100 4 000 3 000 50 0 1 10 µm 5 µm 3 µm 2 3 4 5 6 7 8 Active measuring distance [m] 2 000 1000 0 1 2 10 µm 5 µm 3 µm 3 4 5 6 7 8 Active measuring distance [m] B-18 Dust measuring devices SICK 8016639/2013-09
Scattered Dust measuring light dust devices measuring devices Technologies and services Scattered light measurement A light sender emits light. The particles cause the light to be scattered in the gas mixture, where it is detected by a sensitive receiver. Since it is highly sensitive, the scattered light principle is particularly suitable for low dust concentrations even below 1 mg/m 3. The measuring volume in the gas duct is defined by the overlap of the sender beam and the receiver segment. The scattered light intensity measured is proportionate to the dust concentration and independent of the measuring distance. However, as the intensity of the scattered light is dependent not only on the number and size of the particles but also on their optical properties, the measuring system must be calibrated for precision measurement of the dust concentration by means of a gravimetric comparison measurement. As a leading manufacturer of dust measuring devices, SICK can deliver measuring devices with both backward (see image) and forward scattering. Sender/receiver unit Principle of light scattering to particles Reflection Deflection Light Absorption Refraction Scattered light volume Scattered light intensity dependent on particle size Scattered light intensity [W/m 2 ] 10-5 10-6 10-7 10-8 10-9 10-10 B The scattered light measuring principle is suitable for measuring low to very low dust concentrations. Reflection Deflection 10-11 10-2 10-1 10-0 10-1 Particle size [μm] The scattered light intensity is proportionate to the dust concentration for a given particle size. Other continuous measurement principles The triboelectric or beta radiation measurement principles are used in addition to the proven measurement principles of transmittance and scattered light. These measurement principles can have significant disadvantages, including being affected by the gas velocity, electrical charges, or moisture content of the particles. Separation processes can be more costly and complex and probes can become contaminated. 8016639/2013-09 Dust measuring devices SICK B-19
Technologies and services Scattered light Dust dust measuring devices Discontinuous dust measurement principle Gravimetric determination of dust concentration is the reference method according to directive DIN EN 13284-1 for the calibration of all continuous measuring devices. B Gravimetric analysis The principle of gravimetric analysis is based on the following measuring sequence: Isokinetic sampling of a partial gas flow at a representative measuring point as a fundamental prerequisite Collection of the particles contained in the partial gas flow on or in a filter element Weighing of the filter before and after sampling and determination of pure particle mass Determination of dust concentration from particle mass and sampled volume Measurement of gas velocity and gas temperature Filter head with probe v duct Suction pipe v suction Isokinetic sampling: v suction v duct Drying Protection filter Suction pump Suction pump with control bypass Flow sensor Gas flow meter with thermometer Basic setup of sampling equipment according to VDI 2066 Normalization of the measured values Since the measured values of a measuring system are determined under highly diverse operating conditions (temperature, pressure, humidity, O 2 content), they must be converted to normalized values before they can be compared. 100 H C 2 O [%] 273.15 1013 + P[mbar] i.b. = C 100 273.15 + T [ C] 1013 i.n. 100 273.15 + T [ C] 1013 C i.n. = C 100 H i.n. 2 O [%] 273.15 1013 + P[mbar] C i.b. Dust concentration under operating conditions [mg/m 3 ] C i.n. Dust concentration under normalized or standard conditions [mg/m 3 ] B-20 Dust measuring devices SICK 8016639/2013-09
Scattered Dust measuring light dust devices measuring devices Technologies and services Calibration of measurement on site No continuous procedure is able to measure dust concentration directly without reference material. A gravimetric comparison measurement is necessary for calibration. This measurement determines the dust concentration at the measuring point with the system under different load conditions and with different fuels. A calibration curve is produced from the measured values of the measuring equipment (AMS) and the measured values determined by means of gravimetric measurement. In Europe, the corresponding procedure is specified in standards EN 14181 and EN 13284-1. During calibration, a minimum of 15 pairs of values must be determined. B Gravimetric measuring system At least 15 measurements under different system load conditions (e.g., full load, half load) and with different fuels. mg/m 3 Dust concentration [mg/m 3 ] mg/m 3 Automatic measuring equipment (AMS) ma 0 Regression 0 line for determining the regression function Analog signal from ma AMS Calculation of the regression function (quadratic equation) and implementation in a dust measuring device or a data acquisition system c = cc2 S 2 + cc1 S + cc0 c = Dust concentration in mg/m 3 S = Output signal from the automatic measuring equipment (AMS) 8016639/2013-09 Dust measuring devices SICK B-21
Technologies and services Scattered light Dust dust measuring devices Improving productivity with product and system support and maintenance With reliability and support you can trust, day in and day out. With SICK LifeTime Services you can be sure that the systems and sensors in your machines and systems are always ready and fully operational. B An overview of the services You can make use of SICK services concerning "product & system support" for individual products: Commissioning, commissioning check Initial verification Repairs Remote support and troubleshooting Startup assistance and helpline support Exchange units and spare parts Mounting and commissioning From laying electrical and pneumatic cables, through mounting devices at the measuring point, to setting the device parameters with subsequent instructions in device functions, SICK offers a one-stop solution. The result is problem-free startup of devices and systems. Furthermore, you receive in-depth support on implementing the legal requirements. Maintenance and maintenance contracts Regular and correct maintenance ensures a long service life and reduces wear on components and measuring systems. At the same time, the availability of the system increases and the measurement accuracy of the analysis devices improves. An individual maintenance contract offers additional advantages: fixed maintenance intervals and tasks, provided automatically when necessary. At a fixed price - so that you have all your maintenance costs under control. B-22 Dust measuring devices SICK 8016639/2013-09
Scattered Dust measuring light dust devices measuring devices Technologies and services Maintenance You receive expert and quick support from experienced SICK technicians so that your systems or components can be restored to availability quickly. Your recommendations help avoid faults. If defective components need to be repaired or replaced, this work is carried out by our experienced engineers. Included in the range of services: Error analysis and rectification of faults at the customer's site Adaptation of components or systems in the event of application problems Configuration adaptation and optimization of operational parameters Documentation to avoid faults Regular maintenance increases availability B 8016639/2013-09 Dust measuring devices SICK B-23
Technologies and services Scattered light Dust dust measuring devices Modular service contracts: flexible for every requirement An important part of LifeTime Services from SICK is the modular service concept, which allows every business to create its own individual service contract from different service modules. B Performance, availability, and safety We advise you and you decide which service you would like to use. With modular service contracts, we accommodate all your requirements. Put together your own customized service contract using a variety of standardized modules, as with the SICK Remote Service described below, and pay only for what you need. Assured productivity every time SICK offers round the clock, worldwide experienced and competent partners throughout the entire life cycle of a machine or system.* As the operator, you are then able to concentrate on increasing productivity, efficiency, and income. * No guarantee of worldwide distribution of SICK service elements, due to local restrictions on rights of use and service availability. Extended warranty Performance check Maintenance Inspection Training Helpline support with defined response time Modular service contracts Spare parts concept SICK Remote Service Commissioning Phone lines open during office hours On-site troubleshooting with defined response time B-24 Dust measuring devices SICK 8016639/2013-09
Scattered Dust measuring light dust devices measuring devices Technologies and services SICK Remote Service: secure remote monitoring for efficient service Providing expert assistance and quick service are a priority during commissioning and operation. Fast, system-specific support provided by specialists is more important than ever. Complex systems and growing pressure on costs require optimizing maintenance and providing proactive service. High "First Time Fix Rate" reduces costs SICK Remote Service handles the high first time fix rate requirement with secure Internet connections to enable expert support with just a click no travel and setup time needed. Get the benefits of SICK Remote Service at a variety of levels. Take advantage of targeted expert support speeding up the installation phase, and optimizing the operational phase saving time and travel expenses. We provide a modular "SICK Remote Service" contract model to support you and your requirements at all times. Highest level of safety SICK Remote Service package is based on the web platform having the same name. Quick, high-availability communication via the Internet is designed to the highest safety specifications and poses minimal requirements on customer firewalls. The Internet-based remote maintenance connection to the SICK Remote Service center is always made via highly encrypted data channels and using HTTPS and SSH authentication standards. B 8016639/2013-09 Dust measuring devices SICK B-25
Typical applications Scattered light Dust dust measuring devices B Emissions monitoring Environmental regulations stipulate that certain pollutants in the flue gases emitted by industrial plants, as well as the reference values, must be continuously monitored. These regulations vary from country to country. In many countries, the emissions technology must be performance-tested (according to EN 15267 in Europe, for example, or in the USA conforming to EPA standards). Boasting a comprehensive product portfolio, SICK is able to offer reliable solutions for emissions monitoring. Typical fields of application C Emissions are usually measured at or in the flue gas stacks and chimneys of industrial plants. Typical fields of application for continuous emissions monitoring of dust concentrations can be found in: Power plants Cement plants Waste incineration plants Plants in the steel industry Chemical plants C-26 Dust measuring devices SICK 8016639/2013-09
Scattered Dust measuring light dust devices measuring devices Typical applications Measuring emissions in dry and wet gases In many industrial processes, incineration plants play an important role in the production chain. Measuring devices which are in continuous operation are used at several stages of the manufacturing process. These industrial plants expect a great deal of the measuring devices used to monitor emissions (in relation to the composition, temperature, and humiditiy content of the flue gases, for example). Measurements of dry flue gases Thanks to sophisticated flue gas cleanup systems, usually only very low dust loads are released into the environment by flue gas stacks and chimneys. SICK's innovative dust measuring devices play a vital role here in ensuring that dust emissions meet legal requirements for low limit values and that the strict requirements of operators are complied with. Continuous measurement of minimal to high concentrations, representative measurement results with very high availability for small and large duct diameters, installation on a single side with the high-precision DUSTHUNTER SB100 or the DUSTHUNTER SP100 with probe version, SICK can always be relied upon for the ideal solution. Depending on the medium of the dedusting plant and how the plant operates, the water or acid dew point can be undershot. This results in corrosion of the parts of measuring devices which come into contact with the flue gas. Therefore, both dry and wet flue gases have to be measured with high accuracy while availability remains maximized and maintenance is minimized. Measurements of wet flue gases In most installations (those used for waste treatment or even for metal processing, for example), flue gases are cleaned with scrubbers. However, the fact that these gases are usually cooled significantly and saturated with water poses a particular challenge to dust measuring devices. Here too, reliable and accurate monitoring of the permissible dust limit values is vital. SICK has designed its FWE200DH dust measuring device specifically for this measuring task. The gas is extracted via a sampling probe and heated above dew point in a thermo cyclone. Any droplets in the gas are vaporized and cannot falsify the measurement results. The scattered light principle enables even minimal dust concentrations to be measured. B C DUSTHUNTER SB100 D-54 Kamin mit Tröpfchen Darstellung FWE200DH FWE200DH D-104 8016639/2013-09 Dust measuring devices SICK C-27
Typical applications Scattered light Dust dust measuring devices Measurements of minimal dust concentrations downstream of fabric filters and bag filters B C In a large number of areas of industry, installations for dedusting flue gases have a key role to play where meeting air pollution control requirements is concerned. Alongside the recovery of material, the primary task of dust filter plants is to protect the environment from damage caused by dust emissions. For compliance with permissible limit values and for operational reasons, filter plants of this type must be monitored at regular intervals to ensure that they are functioning correctly. The aim is that faults will be detected in good time and rectified relatively easily. Safe filter monitoring Filter bags have a limited service life. Over time, minor defects develop. As operation continues, they suddenly enlarge and can lead to dust being able to get into the clean gas. Dust measuring devices installed downstream of the panel filter in the clean gas stream can detect this type of damage at an early stage so that the bags concerned can be replaced. The more sensitive and faster the measuring device responds to a change in dust concentration, the more the system can be relied upon to prevent dust breaking through and to conform to limit values. The DUSTHUNTER SP100 is ideal for applications of this nature. It can be installed on the flue gas stack on the clean gas side of a panel filter very easily from a single side. The probe design renders mechanical adjustment and alignment with a particle-free measuring distance unnecessary. Filter monitoring synchronized with cleaning For the operators of dedusting plants and filter plants, it is very important that a faulty filter is detected at an early stage before the permissible limit values are exceeded. Locating a faulty bag or group of bags in the filter plant is also vital so that just the affected component(s) can be replaced. To perform this measuring task, the dust measuring device installed downstream of the filter plant in the clean gas duct must also carry out detection synchronized with cleaning. Faulty filters can then be detected when an emissions peak (above the basic emissions level) occurs in the filter group concerned. It is to this very challenge that the FW102 dust measuring device is able to rise. Baghouse filter DUSTHUNTER SP100 DUSTHUNTER SP100 D-72 FW102 (erwähnt) C-28 Dust measuring devices SICK 8016639/2013-09
Scattered Dust measuring light dust devices measuring devices Typical applications Measurements of high dust concentrations in raw gas upstream of electrical precipitator In the electrical precipitator the process gas is purified from dust particles. The initially high dust concentration of up to 20 g/m 3 is reduced to an average of 15 mg/m 3. The particles are charged via an electric field and electric attractive forces cause them to migrate to what are known as collector electrodes. When the electrodes are knocked off automatically at regular intervals, the particles drop into a collecting container and can be disposed of. The efficiency of the filter must be monitored continuously in order to safeguard the optimum and reliable completion of the downstream stages of the process and to ensure that the electric filter is performing economically. Efficient monitoring of electrical precipitator B For efficient control of filter performance and function monitoring, the dust concentration is measured continuously directly downstream of the electrical precipitator. The dust measuring device used is relied upon to detect increased dust concentrations caused by the precipitator malfunctioning, so that appropriate corrective action can be taken. A particular challenge is the frequently rectangular shape of the gas duct. Temperature variations can cause the duct to distort, resulting in tilting of the optical axis of the dust measuring device. If suitable corrective action is not taken, measurement results will not be accurate. To avoid this, SICK offers the DUSTHUNTER T200, which has already proven its worth in many installations. Equipped with an automatic self-alignment function, this dust measuring device is able to equalize distortion of the duct caused by temperature fluctuations and can be relied upon to produce accurate measurement results at all times. Combined with contamination measurement on both sides, the DUSTHUNTER T200 has a sixmonth maintenance interval and thus costs operators relatively little to run. C DUSTHUNTER T200 DUSTHUNTER T200 E-144 Electrical precipitator DUSTHUNTER SP100 D-72 DUSTHUNTER SP100 (SB100) 8016639/2013-09 Dust measuring devices SICK C-29
Typical applications Scattered light Dust dust measuring devices More applications for effective dust measurements In addition to rising to complex emissions measurement challenges and delivering effective filter monitoring, SICK's versatile dust measuring devices are proving their worth in many other areas of application. B C Air monitoring in large production spaces In large production spaces where dusts of various types are released, reliable monitoring is vital for reasons of personal health and occupational safety. SICK's dust measuring devices are able to detect and measure even fine dusts with particles measuring just a few μm. And in large open-air production spaces like those typical of quarries, for example, dust measuring devices can precisely detect extreme dust formation from crushers. Monitoring in waste dumps Where dusty goods are stored in the open air, gusts of wind, for example, can result in significant dust emissions. Similarly, the handling and transportation of goods on coal tips and in sand processing facilities, or dusts stored in the open air, are usually of relevance where emissions are concerned. For these applications too, SICK can offer exactly the right products meeting a variety of requirements for efficient dust measurements. Process control Accurate and reliable dust measurements can also optimize process control in the monitoring of material transportation in pipelines or similar processes. Other fields of application include air or gas monitoring upstream of gas turbines. C-30 Dust measuring devices SICK 8016639/2013-09
Scattered Dust measuring light dust devices measuring devices Typical applications B C 8016639/2013-09 Dust measuring devices SICK C-31
Scattered light dust measuring devices D Reliable detection of low dust concentrations The measurement principle of scattered light on dust particles enables even very low dust concentrations to be detected. Forward or backward scattering is used depending on requirements. Both methods deliver stable and reproducible measurement results independent of gas velocity, humidity, and particle charge. Your benefits Reliable detection even at very low dust concentrations Easy installation and commissioning Convenient operation Long maintenance intervals thanks to automatic self-monitoring Condition-based maintenance signal Measurements independent of gas velocity, humidity, and particle charge D-32 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices D Scattered light dust measuring devices Product family overview........................................ D-34 DUSTHUNTER SB30........ D-38 Continuous measurements of low and medium dust concentrations DUSTHUNTER SB50........ D-46 The dust measuring device with backward scattered light measurement DUSTHUNTER SB100........ D-54 The type-approved dust measuring device with backward scattered light measurement DUSTHUNTER SF100........ D-62 The cross-duct design dust measuring device with forward scattered light measurement DUSTHUNTER SP100........ D-72 The probe design with forward scattered light measurement FW101 Ex.............. D-82 Effective monitoring of dust concentrations in explosion areas with scattered light FW102................ D-90 Effective monitoring of dust concentrations with scattered light FWE200............... D-98 Extractive dust measuring system for wet gases FWE200DH.............D-104 Extractive dust measuring system for wet gases 8016639/2013-09 Dust measuring devices SICK D-33
ross-reference product family overview Product family overview Scattered light dust measuring devices Product family overview DUSTHUNTER SB30 Continuous measurements of low and medium dust concentrations DUSTHUNTER SB50 The dust measuring device with backward scattered light measurement Technical data Measurement principle Scattered light backward Scattered light backward Measuring components TÜV-approved measured values Measuring ranges Remarks Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Scattered light intensity: 0... 30 SI / 0... 3,000 SI Measuring ranges can be freely selected, there are three preset measuring ranges (0... 30/500/3,000 SI) Dust concentration: 0... 20 mg/m³ / 0... 200 mg/m³ Higher measuring ranges on request Certified measuring ranges Process temperature 40 C... +600 C 40 C... +600 C D Process pressure With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa Duct diameter 500 mm 500 mm Test functions Automatic self-test (linearity, drift, aging), manual linearity test with reference filter Automatic self-test (linearity, drift, aging), manual linearity test with reference filter At a glance For low to medium dust content Easy one-sided installation Automatic check of zero and reference point For medium to large duct diameters For low to medium dust content One-sided installation Automatic check of zero and reference point Automatic compensation of background radiation, therefore no light absorber required For medium to large duct diameters Detailed information --D-38 --D-50 D-34 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices Product family overview DUSTHUNTER SB100 DUSTHUNTER SF100 DUSTHUNTER SP100 The type-approved dust measuring device with backward scattered light measurement The cross-duct design dust measuring device with forward scattered light measurement The probe design with forward scattered light measurement Scattered light backward Scattered light forward Scattered light forward Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Scattered light intensity Scattered light intensity Scattered light intensity Dust concentration: 0... 10 mg/m³ / 0... 200 mg/m³ Dust concentration: 0... 5 mg/m³ / 0... 200 mg/m³ Dust concentration: 0... 5 mg/m³ / 0... 200 mg/m³ Higher measuring ranges on request Higher measuring ranges on request Higher measuring ranges on request Scattered light intensity: 0... 100 SI / 0... 15 SI / 0... 50 SI / 0... 200 SI Scattered light intensity: 0... 50 SI / 0... 5 SI / 0... 20 SI / 0... 100 SI / 0... 200 SI Scattered light intensity: 0... 15 SI / 0... 5 SI / 0... 20 SI / 0... 50 SI / 0... 100 SI / 0... 200 SI 40 C... +600 C 25 C... +300 C Standard design DHSP-T2xx: 40 C... +220 C High-temperature design DHSP-T4xx: 40 C... +400 C With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa 500 mm Automatic self-test (linearity, contamination, drift, aging), contamination limit values: warning at 20 %, fault at 30 %, manual linearity test with reference filter With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa With scattered light receiver DHSF-R0: 0.5 m... 3 m With scattered light receiver DHSF-R1: 2.5 m... 6 m Automatic self-test (linearity, contamination, drift, aging), contamination limit values: warning at 20 %, fault at 30 %, manual linearity test with reference filter With control unit MCU-P: 50 hpa... 10 hpa With external purge air unit: 50 hpa... 30 hpa With instrument air (from customer): 50 hpa... 100 hpa 250 mm Automatic self-test (linearity, contamination, drift, aging), contamination limit values: warning at 30 %, fault at 40 %, manual linearity test with reference filter D For very low to medium dust concentrations One-sided installation Contamination check Automatic check of zero and reference point Automatic compensation of background radiation, therefore no light absorber required For medium to large duct diameters For very low to medium dust concentrations Contamination check Automatic check of zero and reference point For small to medium duct diameters One-sided installation For very low to medium dust concentrations Automatic check of zero and reference point Contamination check Hastelloy probe available for corrosive gases For small to medium duct diameters --D-54 --D-62 --D-72 8016639/2013-09 Dust measuring devices SICK D-35
Product family overview Scattered light dust measuring devices Product family overview D FW101 Ex Effective monitoring of dust concentrations in explosion areas with scattered light FW102 Effective monitoring of dust concentrations with scattered light Technical data Measurement principle Scattered light forward Scattered light forward Measuring components Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Scattered light intensity, dust concentration (according to gravimetric comparison measurement) TÜV-approved measured Dust concentration values Measuring ranges Dust concentration: 0... 5 mg/m³ / 0... 200 mg/m³ Dust concentration: 0... 5 mg/m³ / 0... 200 mg/m³ Remarks Measuring ranges can be freely selected, higher measuring ranges on request Measuring ranges can be freely selected, higher measuring ranges on request Certified measuring ranges Dust concentration: 0... 20 mg/m³ Process temperature Standard design: 40 C... +220 C 20 C... +220 C High-temperature design: 40 C... +400 C Process pressure With external purge air unit: 50 hpa... 30 hpa With instrument air (from customer): 50 hpa... 100 hpa With connection unit with integrated purge air supply: 50 hpa... 10 hpa With external purge air unit: 50 hpa... 70 hpa With instrument air (from customer): 50 hpa... 1,000 hpa Duct diameter 250 mm 150 mm At a glance Test functions Automatic self-test (linearity, contamination, drift, aging), contamination limit values: warning at 30 %, fault at 40 %, manual linearity test with reference filter Automatic control cycle for zero point and reference point Automatic monitoring of zero and reference point Contamination check Optional evaluation unit for remote operation Device versions for ATEX Zones 1, 2, and 22 Automatic monitoring of zero and reference point Optional evaluation unit for connection and remote maintenance of up to three FW102 measuring devices Detailed information --D-82 --D-90 D-36 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices Product family overview FWE200 Extractive dust measuring system for wet gases FWE200DH Extractive dust measuring system for wet gases Scattered light forward Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Dust concentration Scattered light forward Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Dust concentration Dust concentration: 0... 5 mg/m³ / 0... 200 mg/m³ Dust concentration: 0... 5 mg/m³ / 0... 200 mg/m³ Measuring ranges can be freely selected, higher measuring ranges Measuring ranges can be freely selected, higher measuring ranges on request on request Dust concentration: 0... 15 mg/m³ / 0... 50 mg/m³ PVDF probe: +120 C PVDF probe: +120 C Hastelloy probe: +220 C Hastelloy probe: +220 C 20 hpa... 20 hpa With purge air unit SLV4 2BH1300: 20 hpa... 20 hpa With purge air unit SLV4 2BH1400: 40 hpa... 40 hpa Automatic control cycle for zero point and reference point D For very low to medium dust concentrations Gas sampling and return combined in one probe Contamination check Automatic monitoring of zero and reference point For very low to medium dust concentrations Gas sampling and return combined in one probe Contamination check Automatic monitoring of zero and reference point --D-98 --D-104 8016639/2013-09 Dust measuring devices SICK D-37
ross-reference product family overview DUSTHUNTER SB30 Scattered light dust measuring devices Continuous measurements of low and medium dust concentrations D Product description The DUSTHUNTER SB30 is a measuring device for detecting low and medium dust concentrations, e.g., in hot or aggressive gases. The measurement is based on the proven measurement principle of backward light scattering. At a glance For low to medium dust content Easy one-sided installation Automatic check of zero and reference point Your benefits Easy installation, commissioning and operation Proven measurement not dependent on gas velocity, humidity, or particle load Installation is very easy from just one side of the duct. Two different penetration depths are available, enabling the measuring device to be adapted to highly diverse duct diameters. For medium to large duct diameters Cost-effective thanks to easy mounting from just one side; no alignment necessary Self-monitoring for very low maintenance Condition-based maintenance messages Additional information Fields of application............d-39 Detailed technical data..........d-39 Ordering information............d-42 Dimensional drawings..........d-42 -- www.mysick.com/en/dusthunter_sb30 For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. D-38 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SB30 Fields of application Emissions monitoring in industrial plants including, for example, power plants, heating systems, waste incineration plants, in steel production, and in cement plants Monitoring of dust concentrations upstream of filter plants Dust concentration measurements in flue gas ducts upstream and downstream of dust filters Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System DUSTHUNTER SB30 Measured variables Measurement principle Spectral range Measuring ranges Scattered light intensity Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Scattered light backward 640 nm... 660 nm Laser, protection class 2, power < 1 mw 0... 30 SI / 0... 3,000 SI Measuring ranges can be freely selected, there are three preset measuring ranges (0... 30/500/3,000 SI) Response time 1 s... 600 s Freely configurable with SOPAS ET software Accuracy ± 2 % of the measuring range final value Process temperature 40 C... +600 C Process pressure With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa Duct diameter 500 mm Conformity TÜV type test Conforms to China EPA Electrical safety CE Analog outputs 1 output: 0/2/4... 20 ma, 750 Ω D Test functions Options Automatic self-test (linearity, drift, aging) Manual linearity test with reference filter MCU control unit SCU control unit External purge air unit Sender/receiver unit DHSB-T30 Description Measuring system analyzer unit Ambient temperature 40 C... +60 C Enclosure rating IP 66 Analog outputs 1 output: 0/4... 20 ma, 750 Ω Electrically isolated Digital outputs 3 relay contacts: 48 V, 1 A For status signals Digital inputs 2 volt-free contacts: Interfaces Bus protocol For external maintenance switch, automatic self-test or linearity measurement RS-485, for the connection of an MCU control unit or as a service interface CAN, for the connection of an SCU control unit 8016639/2013-09 Dust measuring devices SICK D-39
DUSTHUNTER SB30 Scattered light dust measuring devices Dimensions (W x H x D) Weight Electrical connection Control unit MCU-N Voltage Power consumption Details, see dimensional drawings 7 kg 24 V Supply via the MCU control unit or an external power supply 4 W D Description Ambient temperature 40 C... +60 C Enclosure rating IP 66 Analog outputs Analog inputs Digital outputs Digital inputs Interfaces Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Options Unit to control the system components and to evaluate and output the data provided by them 1 output: 0/2/4... 20 ma, 750 Ω Electrically isolated; two additional outputs if using I/O modules (option) 2 inputs: 0... 20 ma Not electrically isolated; two additional inputs if using I/O modules (option) 5 relay contacts: 48 V, 1 A Volt-free; for status signals 4 volt-free contacts USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) LCD (option) Status LEDs: "Power", "Maintenance", and "Fault" Via LCD (option) or SOPAS ET software 210 mm x 340 mm x 120 mm 3.7 kg Voltage 90... 250 V 24 V DC version available as an option Frequency 47... 63 Hz Power consumption 15 W Interface module(s) I/O module(s) Control unit MCU-P Description Unit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit. Sample quantity 20 m³/h Ambient temperature 40 C... +45 C Suction temperature for the purge air Enclosure rating IP 66 Analog outputs 1 output: 0/2/4... 20 ma, 750 Ω Electrically isolated; two additional outputs if using I/O modules (option) Analog inputs 2 inputs: 0... 20 ma Not electrically isolated; two additional inputs if using I/O modules (option) D-40 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SB30 Digital outputs Digital inputs Interfaces Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Auxiliary connections Options Voltage Frequency Power consumption 5 relay contacts: 48 V, 1 A Volt-free; for status signals 4 volt-free contacts USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) LCD (option) Status LEDs: "Power", "Maintenance", and "Fault" Via LCD (option) or SOPAS ET software 300 mm x 455 mm x 220 mm 13.5 kg 90... 250 V 24 V DC version available as an option 47... 63 Hz 70 W Purge air Interface module(s) I/O module(s) Purge air unit SLV4 2BH1300, 3-ph Description Unit supplying dust-free air for purging optical surfaces Sample quantity 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) 550 mm x 550 mm x 258 mm (for details see dimensional drawings) Weight 18 kg Electrical connection 3-phase, Δ: 200... 240 V / 50 Hz / 2.6 A / 350 W 3-phase, Δ: 220... 275 V / 60 Hz / 2.3 A / 450 W 3-phase, Y: 345... 415 V / 50 Hz / 1.5 A / 350 W 3-phase, Y: 380... 480 V / 60 Hz / 1.3 A / 450 W Auxiliary connections Purge air: 40 mm Test functions Low pressure warning device (switching point 35 hpa) Integrated components Two-stage air filter, Europiclon type, dust capacity 200 g D 8016639/2013-09 Dust measuring devices SICK D-41
Meas DUSTHUNTER SB30 Scattered light dust measuring devices Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Sender/receiver unit DHSB-T30 295 45 Dimensions in mm Ø 15 156 120 110 Ø 40 Ø 225 Ø 265 r = 270 196 206 D Control unit MCU-N 210 160 120 340 320 300 D-42 Dust measuring devices SICK 8016639/2013-09
Meas Scattered light dust measuring devices DUSTHUNTER SB30 Control unit MCU-P 260 Ø 8 455 420 400 300 220 Mounting flange, D i =195 mm 45 45 350/700 M12 Ø 195 D Ø 225 Ø 265 8016639/2013-09 Dust measuring devices SICK D-43
DUSTHUNTER SB30 Scattered light dust measuring devices Purge air unit SLV4 2BH1300, 3-ph Ø 10 550 470 40 40 470 128 550 258 Weather hood for DHSB/DHSF-R1/DHC-R1 239 D 360 492 365 D-44 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SB30 Weather hood for purge air unit SLV4/SLV5 255 550 550 340 605 D 8016639/2013-09 Dust measuring devices SICK D-45
ross-reference product family overview DUSTHUNTER SB50 Scattered light dust measuring devices The dust measuring device with backward scattered light measurement D Product description The DUSTHUNTER SB50 is a measuring device for detecting low to medium dust content in complex applications such as those involving hot or aggressive gases, for example. The measurement is based on backward light scattering. The At a glance For low to medium dust content One-sided installation Automatic check of zero and reference point Your benefits Easy installation, commissioning and operation Measurement not dependent on gas velocity, humidity, or particle load Self-monitoring for low maintenance equipment is installed from just one side of the duct. There are two possible penetration depths. As background radiation is compensated automatically, a light absorber is not necessary. Automatic compensation of background radiation, therefore no light absorber required For medium to large duct diameters Additional information Fields of application............d-47 Detailed technical data..........d-47 Ordering information............d-50 Dimensional drawings..........d-50 -- www.mysick.com/en/dusthunter_sb50 For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. D-46 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SB50 Fields of application Emissions monitoring in heating systems Monitoring of dust concentrations upstream of filter plants Dust concentration measurements in cement plants Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System DUSTHUNTER SB50 Measured variables Measurement principle Spectral range Measuring ranges Dust concentration Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Scattered light backward 640 nm... 660 nm Laser, protection class 2, power < 1 mw 0... 20 mg/m³ / 0... 200 mg/m³ Higher measuring ranges on request Response time 1 s... 600 s Freely configurable Accuracy ± 2 % of the measuring range final value Process temperature 40 C... +600 C Process pressure With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa Process gas humidity Non-condensing Duct diameter 500 mm Electrical safety CE Test functions Automatic self-test (linearity, drift, aging) Manual linearity test with reference filter D Sender/receiver unit DHSB-T00/-T01 Ambient temperature 40 C... +60 C Enclosure rating IP 66 Dimensions (W x H x D) 265 mm x 274 mm x 691 mm (for details see dimensional drawings) Weight 9 kg Electrical connection Voltage 24 V Supply via control unit Power consumption 4 W Control unit MCU-N Description Unit to control the system components and to evaluate and output the data provided by them Ambient temperature 40 C... +60 C Enclosure rating IP 66 Analog outputs 1 output: 0/2/4... 20 ma, 750 Ω Electrically isolated; two additional outputs if using I/O modules (option) Analog inputs 2 inputs: 0... 20 ma Not electrically isolated; two additional inputs if using I/O modules (option) 8016639/2013-09 Dust measuring devices SICK D-47
DUSTHUNTER SB50 Scattered light dust measuring devices Digital outputs Digital inputs Interfaces Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Options Control unit MCU-P Voltage Frequency Power consumption 5 relay contacts: 48 V, 1 A Volt-free; for status signals 4 volt-free contacts USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) LCD (option) Status LEDs: "Power", "Maintenance", and "Fault" Via LCD (option) or SOPAS ET software 210 mm x 340 mm x 120 mm 3.7 kg 90... 250 V 24 V DC version available as an option 47... 63 Hz 15 W Interface module(s) I/O module(s) D Description Unit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit. Sample quantity 20 m³/h Ambient temperature 40 C... +45 C Suction temperature for the purge air Enclosure rating IP 66 Analog outputs 1 output: 0/2/4... 20 ma, 750 Ω Electrically isolated; two additional outputs if using I/O modules (option) Analog inputs 2 inputs: 0... 20 ma Not electrically isolated; two additional inputs if using I/O modules (option) Digital outputs 5 relay contacts: 48 V, 1 A Volt-free; for status signals Digital inputs 4 volt-free contacts Interfaces USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Bus protocol Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) Display LCD (option) Status LEDs: "Power", "Maintenance", and "Fault" Operation Via LCD (option) or SOPAS ET software Dimensions (W x H x D) 300 mm x 455 mm x 220 mm Weight 13.5 kg Electrical connection Voltage 90... 250 V D-48 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SB50 Auxiliary connections Options Frequency Power consumption 24 V DC version available as an option 47... 63 Hz 70 W Purge air Interface module(s) I/O module(s) Purge air unit SLV4 2BH1300, 3-ph Description Unit supplying dust-free air for purging optical surfaces Sample quantity 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) 550 mm x 550 mm x 258 mm (for details see dimensional drawings) Weight 18 kg Electrical connection 3-phase, Δ: 200... 240 V / 50 Hz / 2.6 A / 350 W 3-phase, Δ: 220... 275 V / 60 Hz / 2.3 A / 450 W 3-phase, Y: 345... 415 V / 50 Hz / 1.5 A / 350 W 3-phase, Y: 380... 480 V / 60 Hz / 1.3 A / 450 W Auxiliary connections Purge air: 40 mm Test functions Low pressure warning device (switching point 35 hpa) Integrated components Two-stage air filter, Europiclon type, dust capacity 200 g D 8016639/2013-09 Dust measuring devices SICK D-49
Meas DUSTHUNTER SB50 Scattered light dust measuring devices Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Sender/receiver unit DHSB-T00/-T01 109 Ø 15 397 315 692 Dimensions in mm 242 201 105 14 Ø 225 Ø 265 125 168 342 Ø 169 Ø 159 D 212 208 202 Control unit MCU-N 210 160 120 340 320 300 D-50 Dust measuring devices SICK 8016639/2013-09
Meas Scattered light dust measuring devices DUSTHUNTER SB50 Control unit MCU-P 260 Ø 8 455 420 400 300 220 Mounting flange, D i =195 mm 45 45 350/700 M12 Ø 195 D Ø 225 Ø 265 8016639/2013-09 Dust measuring devices SICK D-51
DUSTHUNTER SB50 Scattered light dust measuring devices Purge air unit SLV4 2BH1300, 3-ph Ø 10 550 470 40 40 470 128 550 258 Weather hood for DHSB/DHSF-R1/DHC-R1 239 D 360 492 365 D-52 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SB50 Weather hood for purge air unit SLV4/SLV5 255 550 550 340 605 D 8016639/2013-09 Dust measuring devices SICK D-53
ross-reference product family overview DUSTHUNTER SB100 Scattered light dust measuring devices The type-approved dust measuring device with backward scattered light measurement D Product description The DUSTHUNTER SB100 is a type-approved measuring device for detecting very low to medium dust content in complex applications such as those involving hot or aggressive gases, for example. The measurement is based on backward light scattering. The equipment is installed from just one side of the duct. At a glance For very low to medium dust concentrations One-sided installation Contamination check Automatic check of zero and reference point Your benefits Easy installation, commissioning and operation Measurement not dependent on gas velocity, humidity, or particle load Type-approved to EN 15267 There are two possible penetration depths. As background radiation is compensated automatically, a light absorber is not necessary. Automatic checking of the zero and reference points as well as a contamination check are integrated into the device. Automatic compensation of background radiation, therefore no light absorber required For medium to large duct diameters Self-monitoring for low maintenance 15267 approved 14181 approved Additional information Fields of application............d-55 Detailed technical data..........d-55 Ordering information............d-58 Dimensional drawings..........d-58 -- www.mysick.com/en/dusthunter_sb100 For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. D-54 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SB100 Fields of application Emissions monitoring in power plants and waste incineration plants Monitoring of filter plants Monitoring of dust load in factories Control of air supplies and exhaust air installations Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System DUSTHUNTER SB100 Measured variables TÜV-approved measured values Measurement principle Spectral range Measuring ranges Dust concentration Certified measuring ranges Scattered light intensity Response time Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Scattered light intensity Scattered light backward 640 nm... 660 nm Laser, protection class 2, power < 1 mw 0... 10 mg/m³ / 0... 200 mg/m³ Higher measuring ranges on request 0... 100 SI / 0... 15 SI / 0... 50 SI / 0... 200 SI 1 s... 600 s Freely configurable Accuracy 2 % of the measuring range final value Process temperature 40 C... +600 C Process pressure With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa Process gas humidity Non-condensing Duct diameter 500 mm Conformity Approved for system requiring permission 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV (Traffic Noise Protection) EN 14181 EN 15267 MCERTS TA-Luft (Prevention of Air Pollution) Electrical safety CE Test functions Automatic self-test (linearity, contamination, drift, aging) Contamination limit values: warning at 20 %, fault at 30 % Manual linearity test with reference filter D Sender/receiver unit DHSB-T10/-T11 Ambient temperature 40 C... +60 C Enclosure rating IP 66 Dimensions (W x H x D) 265 m x 274 m x 691 m (for details see dimensional drawings) Weight 10 kg Electrical connection Voltage 24 V Supply via control unit Power consumption 4 W 8016639/2013-09 Dust measuring devices SICK D-55
DUSTHUNTER SB100 Scattered light dust measuring devices Control unit MCU-N D Description Ambient temperature 40 C... +60 C Enclosure rating IP 66 Analog outputs Analog inputs Digital outputs Digital inputs Interfaces Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Options Unit to control the system components and to evaluate and output the data provided by them 3 outputs: 0/2/4... 20 ma, 750 Ω Electrically isolated; two additional outputs if using I/O modules (option) 2 inputs: 0... 20 ma Not electrically isolated; two additional inputs if using I/O modules (option) 5 relay contacts: 48 V, 1 A Volt-free; for status signals 4 volt-free contacts USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) LCD Status LEDs: "Power", "Maintenance", and "Fault" Via LCD or SOPAS ET software 210 mm x 340 mm x 120 mm 3.7 kg Voltage 90... 250 V 24 V DC version available as an option Frequency 47... 63 Hz Power consumption 15 W Interface module(s) I/O module(s) Control unit MCU-P Description Unit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit. Sample quantity 20 m³/h Ambient temperature 40 C... +45 C Suction temperature for the purge air Enclosure rating IP 66 Analog outputs 3 outputs: 0/2/4... 20 ma, 750 Ω Electrically isolated; two additional outputs if using I/O modules (option) Analog inputs 2 inputs: 0... 20 ma Not electrically isolated; two additional inputs if using I/O modules (option) Digital outputs 5 relay contacts: 48 V, 1 A Volt-free; for status signals Digital inputs 4 volt-free contacts Interfaces USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) D-56 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SB100 Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Auxiliary connections Options Voltage Frequency Power consumption Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) LCD Status LEDs: "Power", "Maintenance", and "Fault" Via LCD or SOPAS ET software 300 mm x 455 mm x 220 mm 13.5 kg 90... 250 V 24 V DC version available as an option 47... 63 Hz 70 W Purge air Interface module(s) I/O module(s) Purge air unit SLV4 2BH1300, 3-ph Description Unit supplying dust-free air for purging optical surfaces Sample quantity 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) 550 mm x 550 mm x 258 mm (for details see dimensional drawings) Weight 18 kg Electrical connection 3-phase, Δ: 200... 240 V / 50 Hz / 2.6 A / 350 W 3-phase, Δ: 220... 275 V / 60 Hz / 2.3 A / 450 W 3-phase, Y: 345... 415 V / 50 Hz / 1.5 A / 350 W 3-phase, Y: 380... 480 V / 60 Hz / 1.3 A / 450 W Auxiliary connections Purge air: 40 mm Test functions Low pressure warning device (switching point 35 hpa) Integrated components Two-stage air filter, Europiclon type, dust capacity 200 g D 8016639/2013-09 Dust measuring devices SICK D-57
Meas DUSTHUNTER SB100 Scattered light dust measuring devices Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Sender/receiver unit DHSB-T10/-T11 109 Ø 15 397 315 692 Dimensions in mm 242 201 105 14 Ø 225 Ø 265 125 168 342 Ø 169 Ø 159 D 212 208 202 Control unit MCU-N 210 160 120 340 320 300 D-58 Dust measuring devices SICK 8016639/2013-09
Meas Scattered light dust measuring devices DUSTHUNTER SB100 Control unit MCU-P 260 Ø 8 455 420 400 300 220 Mounting flange, D i =195 mm 45 45 350/700 M12 Ø 195 D Ø 225 Ø 265 8016639/2013-09 Dust measuring devices SICK D-59
DUSTHUNTER SB100 Scattered light dust measuring devices Purge air unit SLV4 2BH1300, 3-ph Ø 10 550 470 40 40 470 128 550 258 Weather hood for DHSB/DHSF-R1/DHC-R1 239 D 360 492 365 D-60 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SB100 Weather hood for purge air unit SLV4/SLV5 255 550 550 340 605 D 8016639/2013-09 Dust measuring devices SICK D-61
ross-reference product family overview DUSTHUNTER SF100 Scattered light dust measuring devices The cross-duct design dust measuring device with forward scattered light measurement Product description The DUSTHUNTER SF100 is a type-approved measuring device for detecting very low to medium dust content. The measurement is based on forward light At a glance For very low to medium dust concentrations Contamination check scattering. Automatic checking of the zero and reference points as well as a contamination check are integrated into the device. Automatic check of zero and reference point For small to medium duct diameters D Your benefits For difficult duct geometries and media conditions Type-approved to EN 15267 Self-monitoring and contamination check for low maintenance 15267 approved 14181 approved Additional information Fields of application............d-63 Detailed technical data..........d-63 Ordering information............d-66 Dimensional drawings..........d-66 -- www.mysick.com/en/dusthunter_sf100 For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. D-62 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SF100 Fields of application Emissions monitoring in power plants and waste incineration plants Monitoring of filter plants Monitoring of dust load in factories Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System DUSTHUNTER SF100 Measured variables TÜV-approved measured values Measurement principle Spectral range Measuring ranges Dust concentration Certified measuring ranges Scattered light intensity Response time Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Scattered light intensity Scattered light forward 640 mm... 660 mm Laser, protection class 2, power < 1 mw 0... 5 mg/m³ / 0... 200 mg/m³ Higher measuring ranges on request 0... 50 SI / 0... 5 SI / 0... 20 SI / 0... 100 SI / 0... 200 SI 1 s... 600 s Freely configurable Accuracy 2 % of the measuring range final value Process temperature 25 C... +300 C Process pressure With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa Process gas humidity Non-condensing Duct diameter With scattered light receiver DHSF-R0: 0.5 m... 3 m With scattered light receiver DHSF-R1: 2.5 m... 6 m Conformity Approved for system requiring permission 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV (Traffic Noise Protection) EN 14181 EN 15267 MCERTS TA-Luft (Prevention of Air Pollution) Electrical safety CE Test functions Automatic self-test (linearity, contamination, drift, aging) Contamination limit values: warning at 20 %, fault at 30 % Manual linearity test with reference filter D Sender unit DHSF-T Ambient temperature 40 C... +60 C Enclosure rating IP 66 Dimensions (W x H x D) 212 mm x 241 mm x 429 mm (for details see dimensional drawings) Weight 10 kg Electrical connection Voltage 24 V Supply via control unit Power consumption 17 W 8016639/2013-09 Dust measuring devices SICK D-63
DUSTHUNTER SF100 Scattered light dust measuring devices Receiver unit DHSF-R0 Ambient temperature 40 C... +60 C Enclosure rating IP 66 Dimensions (W x H x D) 212 mm x 241 mm x 420 mm (for details see dimensional drawings) Weight 6.5 kg Receiver unit DHSF-R1 Ambient temperature 40 C... +60 C Enclosure rating IP 66 Dimensions (W x H x D) 265 mm x 308 mm x 550 mm (for details see dimensional drawings) Weight 8 kg Control unit MCU-N D Description Ambient temperature 40 C... +60 C Enclosure rating IP 66 Analog outputs Analog inputs Digital outputs Digital inputs Interfaces Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Options Unit to control the system components and to evaluate and output the data provided by them 3 outputs: 0/2/4... 20 ma, 750 Ω Electrically isolated; two additional outputs if using I/O modules (option) 2 inputs: 0... 20 ma Not electrically isolated; two additional inputs if using I/O modules (option) 5 relay contacts: 48 V, 1 A Volt-free; for status signals 4 volt-free contacts USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) LCD Status LEDs: "Power", "Maintenance", and "Fault" Via LCD or SOPAS ET software 210 mm x 340 mm x 120 mm 3.7 kg Voltage 90... 250 V 24 V DC version available as an option Frequency 47... 63 Hz Power consumption 15 W Interface module(s) I/O module(s) D-64 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SF100 Control unit MCU-P Description Unit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit. Sample quantity 20 m³/h Ambient temperature 40 C... +45 C Suction temperature for the purge air Enclosure rating IP 66 Analog outputs 3 outputs: 0/2/4... 20 ma, 750 Ω Electrically isolated; two additional outputs if using I/O modules (option) Analog inputs 2 inputs: 0... 20 ma Not electrically isolated; two additional inputs if using I/O modules (option) Digital outputs 5 relay contacts: 48 V, 1 A Volt-free; for status signals Digital inputs 4 volt-free contacts Interfaces USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Bus protocol Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) Display LCD Status LEDs: "Power", "Maintenance", and "Fault" Operation Via LCD or SOPAS ET software Dimensions (W x H x D) 300 mm x 455 mm x 220 mm Weight 13.5 kg Electrical connection Voltage 90... 250 V 24 V DC version available as an option Frequency 47... 63 Hz Power consumption 70 W Auxiliary connections Purge air Options Interface module(s) I/O module(s) D 8016639/2013-09 Dust measuring devices SICK D-65
DUSTHUNTER SF100 Scattered light dust measuring devices Purge air unit SLV4 2BH1300, 3-ph Description Sample quantity Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) Weight Electrical connection Auxiliary connections Test functions Integrated components Unit supplying dust-free air for purging optical surfaces 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter 550 mm x 550 mm x 258 mm (for details see dimensional drawings) 18 kg 3-phase, Δ: 200... 240 V / 50 Hz / 2.6 A / 350 W 3-phase, Δ: 220... 275 V / 60 Hz / 2.3 A / 450 W 3-phase, Y: 345... 415 V / 50 Hz / 1.5 A / 350 W 3-phase, Y: 380... 480 V / 60 Hz / 1.3 A / 450 W Purge air: 40 mm Low pressure warning device (switching point 35 hpa) Two-stage air filter, Europiclon type, dust capacity 200 g Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Dimensions in mm Sender unit DHSF-T 429 D 104 309 401 65 Ø 126 13 Ø 11 Ø 100 241 200 205 208 125 168 355 212 208 202 Ø 60 D-66 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SF100 Receiver unit DHSF-R0 99 420 367 339 257 65 Ø 11 208 Ø 100 241 200 212 208 202 13 60 103 298 205 Ø 126 Ø 61 D 8016639/2013-09 Dust measuring devices SICK D-67
Meas DUSTHUNTER SF100 Scattered light dust measuring devices Receiver unit DHSF-R1 265 Ø 15 257 352 402 308 241 200 13 97 225 103 299 550 212 208 202 Ø 144 Ø 239 205 Ø 80 D Control unit MCU-N 210 160 120 340 320 300 D-68 Dust measuring devices SICK 8016639/2013-09
Meas Scattered light dust measuring devices DUSTHUNTER SF100 Control unit MCU-P 260 Ø 8 455 420 400 300 220 Mounting flange, D i =70.2 mm 45 45 M10 76 70,2 M10 D 100 130 L = 130/240/500 8016639/2013-09 Dust measuring devices SICK D-69
DUSTHUNTER SF100 Scattered light dust measuring devices Mounting flange, D i =152 mm 45 45 M12 159 152 M12 225 L = 240/500 265 Purge air unit SLV4 2BH1300, 3-ph Ø 10 D 550 470 40 40 470 128 550 258 D-70 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SF100 Weather hood for sender/receiver unit 239 360 492 365 Weather hood for DHSB/DHSF-R1/DHC-R1 239 360 492 365 D Weather hood for purge air unit SLV4/SLV5 255 550 550 340 605 8016639/2013-09 Dust measuring devices SICK D-71
ross-reference product family overview DUSTHUNTER SP100 Scattered light dust measuring devices The probe design with forward scattered light measurement D Product description The DUSTHUNTER SP100 is a type-approved measuring device for detecting very low to medium dust content. Its design features a measuring probe. Since it is installed from just one side, it is particularly suitable for ducts with thick At a glance One-sided installation For very low to medium dust concentrations Automatic check of zero and reference point Your benefits Ideal for ducts with thick or double walls Type-approved to EN 15267 or double walls. The measurement is based on forward light scattering. Automatic checking of the zero and reference points as well as a contamination check are integrated into the device. Contamination check Hastelloy probe available for corrosive gases For small to medium duct diameters Self-monitoring and contamination check for low maintenance 15267 approved 14181 approved Additional information Fields of application............d-73 Detailed technical data..........d-73 Ordering information............d-76 Dimensional drawings..........d-76 -- www.mysick.com/en/dusthunter_sp100 For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. D-72 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SP100 Fields of application Emissions monitoring in power plants and waste incineration plants Monitoring of filter plants Measurements in flue gas or exhaust air ducts Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System DUSTHUNTER SP100 Measured variables TÜV-approved measured values Measurement principle Spectral range Measuring ranges Dust concentration Certified measuring ranges Scattered light intensity Response time Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Scattered light intensity Scattered light forward 640 mm... 660 mm Laser, protection class 2, power < 1 mw 0... 5 mg/m³ / 0... 200 mg/m³ Higher measuring ranges on request 0... 15 SI / 0... 5 SI / 0... 20 SI / 0... 50 SI / 0... 100 SI / 0... 200 SI 1 s... 600 s Freely configurable Accuracy 2 % of the measuring range final value Process temperature Standard design DHSP-T2xx: 40 C... +220 C High-temperature design DHSP-T4xx: 40 C... +400 C Process pressure With control unit MCU-P: 50 hpa... 10 hpa With external purge air unit: 50 hpa... 30 hpa With instrument air (from customer): 50 hpa... 100 hpa Process gas humidity Non-condensing Duct diameter 250 mm Conformity Approved for system requiring permission 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV (Traffic Noise Protection) EN 14181 EN 15267 TA-Luft (Prevention of Air Pollution) MCERTS Conforms to U.S. EPA PS-11 Electrical safety CE Test functions Automatic self-test (linearity, contamination, drift, aging) Contamination limit values: warning at 30 %, fault at 40 % Manual linearity test with reference filter D 8016639/2013-09 Dust measuring devices SICK D-73
DUSTHUNTER SP100 Scattered light dust measuring devices Sender/receiver unit DHSP-Txxx Ambient temperature 40 C... +60 C Enclosure rating IP 66 Dimensions (W x H x D) Weight Electrical connection Control unit MCU-N Voltage Power consumption Details, see dimensional drawings Nominal length 435 mm: 6.5 kg Nominal length 735 mm: 7.8 kg Nominal length 1,035 mm: 9.5 kg Nominal length 1,335 mm: 11 kg 24 V Supply via control unit 4 W D Description Ambient temperature 40 C... +60 C Enclosure rating IP 66 Analog outputs Analog inputs Digital outputs Digital inputs Interfaces Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Options Unit to control the system components and to evaluate and output the data provided by them 3 outputs: 0/2/4... 20 ma, 750 Ω Electrically isolated; two additional outputs if using I/O modules (option) 2 inputs: 0... 20 ma Not electrically isolated; two additional inputs if using I/O modules (option) 5 relay contacts: 48 V, 1 A Volt-free; for status signals 4 volt-free contacts USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) LCD Status LEDs: "Power", "Maintenance", and "Fault" Via LCD or SOPAS ET software 210 mm x 340 mm x 120 mm 3.7 kg Voltage 90... 250 V 24 V DC version available as an option Frequency 47... 63 Hz Power consumption 15 W Interface module(s) I/O module(s) D-74 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SP100 Control unit MCU-P Description Unit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit. Sample quantity 20 m³/h Ambient temperature 40 C... +45 C Suction temperature for the purge air Enclosure rating IP 66 Analog outputs 3 outputs: 0/2/4... 20 ma, 750 Ω Electrically isolated; two additional outputs if using I/O modules (option) Analog inputs 2 inputs: 0... 20 ma Not electrically isolated; two additional inputs if using I/O modules (option) Digital outputs 5 relay contacts: 48 V, 1 A Volt-free; for status signals Digital inputs 4 volt-free contacts Interfaces USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Bus protocol Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) Display LCD Status LEDs: "Power", "Maintenance", and "Fault" Operation Via LCD or SOPAS ET software Dimensions (W x H x D) 300 mm x 455 mm x 220 mm Weight 13.5 kg Electrical connection Voltage 90... 250 V 24 V DC version available as an option Frequency 47... 63 Hz Power consumption 70 W Auxiliary connections Purge air Options Interface module(s) I/O module(s) D 8016639/2013-09 Dust measuring devices SICK D-75
DUSTHUNTER SP100 Scattered light dust measuring devices Purge air unit SLV4 2BH1300, 3-ph Description Sample quantity Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) Weight Electrical connection Auxiliary connections Test functions Integrated components Unit supplying dust-free air for purging optical surfaces 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter 550 mm x 550 mm x 258 mm (for details see dimensional drawings) 18 kg 3-phase, Δ: 200... 240 V / 50 Hz / 2.6 A / 350 W 3-phase, Δ: 220... 275 V / 60 Hz / 2.3 A / 450 W 3-phase, Y: 345... 415 V / 50 Hz / 1.5 A / 350 W 3-phase, Y: 380... 480 V / 60 Hz / 1.3 A / 450 W Purge air: 40 mm Low pressure warning device (switching point 35 hpa) Two-stage air filter, Europiclon type, dust capacity 200 g Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Dimensions in mm Sender/receiver unit DHSP-Txx1/-Txx2 D 180 90 Ø 125 L1 L2 L3 216 180 90 Ø 100 Ø 25 55 80 Ø 12 183 233 290 Ø 76 Ø 60 Ø 54 Sender/receiver unit type L1 Nominal length of probe L2 L3 DHSP-Txx1 725 435 300 DHSP-Txx2 1,025 735 300 All dimensions in mm D-76 Dust measuring devices SICK 8016639/2013-09
Meas Scattered light dust measuring devices DUSTHUNTER SP100 Sender/receiver unit DHSP-Txx3/-Txx4/-Txx5/-Txx6/-Txx7 180 90 L1 L2 L3 Ø 150 216 175 85 Ø 190 Ø 25 55 80 183 615 Ø 13 216 805 312 Ø 76 Ø 76 Ø 54 Sender/receiver unit type L1 Nominal length of probe L2 DHSP-Txx3 1,347 1,035 900 DHSP-Txx4 1,647 1,335 1,200 DHSP-Txx5 1,947 1,635 1,500 DHSP-Txx6 2,147 1,835 1,700 DHSP-Txx7 2,397 2,085 1,950 All dimensions in mm L3 D Control unit MCU-N 210 160 120 340 320 300 8016639/2013-09 Dust measuring devices SICK D-77
Meas DUSTHUNTER SP100 Scattered light dust measuring devices Control unit MCU-P 260 Ø 8 455 420 400 300 220 Mounting flange, D i =70.2 mm 45 45 M10 D 76 70,2 M10 100 130 L = 130/240/500 Mounting flange, D i =125 mm 45 45 M12 127 120 M12 150 190 L = 800/1.100 D-78 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SP100 Purge air unit SLV4 2BH1300, 3-ph Ø 10 550 470 40 40 470 128 550 258 Weather hood for sender/receiver unit 239 360 D 492 365 Weather hood for sender/receiver unit DHSP-Txx3/-Txx4/-Txx5/-Txx6/-Txx7 239 360 492 365 8016639/2013-09 Dust measuring devices SICK D-79
DUSTHUNTER SP100 Scattered light dust measuring devices Weather hood for purge air unit SLV4/SLV5 255 550 550 340 605 D D-80 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices DUSTHUNTER SP100 D 8016639/2013-09 Dust measuring devices SICK D-81
ross-reference product family overview FW101 Ex Scattered light dust measuring devices Effective monitoring of dust concentrations in explosion areas with scattered light D Product description At a glance Automatic monitoring of zero and reference point Contamination check Your benefits One-sided installation Easy mounting The FW101 Ex measuring device is used for continuous measuring of low to medium dust concentrations. It takes its measurements independent of gas velocity, humidity, and particle charge. The probe design of the FW101 Ex is particularly advantageous. Mounted on one side of the gas duct, it needs neither mechanical adjustment nor alignment on dustfree measuring distance. As a result, the measuring device is very versatile. It can be used, for example, both for gas ducts with small to large diameters and for chimneys with thin and thick walls. Optional evaluation unit for remote operation Device versions for ATEX Zones 1, 2, and 22 Measurements in explosion areas Additional information Fields of application............d-83 Detailed technical data..........d-83 Ordering information............d-85 Dimensional drawings..........d-86 -- www.mysick.com/en/fw101_ex For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. D-82 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FW101 Ex Fields of application Clean gas monitoring downstream of filter plants Monitoring of cloth filters for broken filters Dust monitoring in grinding plants and dosing systems Protection of flue gas desulfurization plants against excess dust load Monitoring and control of air supply and exhaust air installations Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System FW101 Ex Measured variables Measurement principle Spectral range Measuring ranges Dust concentration Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Scattered light forward 640 nm... 660 nm Laser, protection class 2, power < 1 mw 0... 5 mg/m³ / 0... 200 mg/m³ Measuring ranges freely selectable Higher measuring ranges on request Response time 0.1 s... 600 s Freely configurable Accuracy ± 2 % of the measuring range final value Process temperature Standard design: 40 C... +220 C High-temperature design: 40 C... +400 C Process pressure With external purge air unit: 50 hpa... 30 hpa With instrument air (from customer): 50 hpa... 100 hpa Process gas humidity Non-condensing Duct diameter 250 mm Electrical safety CE Test functions Automatic self-test (linearity, contamination, drift, aging) Contamination limit values: warning at 30 %, fault at 40 % Manual linearity test with reference filter Options External purge air unit D Sender/receiver unit FWSE101 Ex Description Measuring system analyzer unit Ambient temperature 20 C... +40 C Ex approvals ATEX Design for Zone 1 and 2: II 2G Ex IIC T6 Design for Zone 22: II 3D Ex t IIIB T80 C Dc IP 54 Enclosure rating IP 66 Dimensions (W x H x D) 180 mm x 200 mm x 700 mm (nominal length 435 mm, for details see dimensional drawings) 180 mm x 200 mm x 1,000 mm (nominal length 735 mm, for details see dimensional drawings) Weight Nominal length 435 mm: 10.6 kg Nominal length 735 mm: 11.9 kg Electrical connection Voltage 24 V Power consumption Supply via connection unit 4 W 8016639/2013-09 Dust measuring devices SICK D-83
FW101 Ex Scattered light dust measuring devices Connection unit AK1-Ex Description Unit for connecting data cables and power supply for system components; for use in explosion areas Ambient temperature 20 C... +40 C Ex approvals ATEX II 2G Ex de IIC T6 Enclosure rating IP 65 Analog outputs 1 output: 0/2/4... 20 ma, 750 Ω Electrically isolated, second optional output Digital outputs 3 relay contacts: 48 V, 1 A Volt-free; for operation/fault status signals, limit value, maintenance Digital inputs 1 input: Interfaces Bus protocol Display Dimensions (W x H x D) Weight Electrical connection Voltage Frequency Power consumption Volt-free; for maintenance switch RS-232 (service interface) CAN (option), for the connection of an evaluation unit Two-line LCD 210 mm x 493 mm x 180 mm (for details see dimensional drawings) 13.3 kg 100... 240 V 47... 63 Hz 15 W D Connection unit AK1-Ex22 Description Unit for connecting data cables and power supply for system components; for use in dust explosion areas Ambient temperature 20 C... +40 C Ex approvals ATEX II 2D Ex td A21 T80 C IP 6X Enclosure rating IP 65 Analog outputs 1 output: 0/2/4... 20 ma, 750 Ω Electrically isolated, second optional output Digital outputs 3 relay contacts: 48 V, 1 A Volt-free; for operation/fault status signals, limit value, maintenance Digital inputs 1 input: Interfaces Bus protocol Display Dimensions (W x H x D) Weight Electrical connection Voltage Frequency Power consumption Volt-free; for maintenance switch RS-232 (service interface) CAN (option), for the connection of an evaluation unit Two-line LCD 200 mm x 300 mm x 155 mm (for details see dimensional drawings) 4.9 kg 100... 240 V Optional: 24 V DC ± 2 V 47... 63 Hz 15 W D-84 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FW101 Ex Purge air unit SLV5 2BH1300, Ex 2/3G Description Unit supplying dust-free air for purging optical surfaces; for use in explosion areas Sample quantity 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) 550 mm x 550 mm x 258 mm (for details see dimensional drawings) Weight 18 kg Electrical connection 3-phase, Δ: 230 V / 50 Hz / 2.4 A / 550 W 3-phase, Y: 400 V / 50 Hz / 1.4 A / 550 W Auxiliary connections Purge air: 40 mm Test functions Low pressure warning device (switching point 35 hpa) Integrated components Two-stage air filter, Europiclon type, dust capacity 200 g Purge air unit SLV5 2BH1300, Ex 2/3D Description Unit supplying dust-free air for purging optical surfaces; for use in dust explosion areas Sample quantity 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) 550 mm x 550 mm x 258 mm (for details see dimensional drawings) Weight 18 kg Electrical connection 3-phase, Δ: 230 V / 50 Hz / 2.4 A / 550 W 3-phase, Y: 400 V / 50 Hz / 1.4 A / 550 W Auxiliary connections Purge air: 40 mm Test functions Low pressure warning device (switching point 35 hpa) Integrated components Two-stage air filter, Europiclon type, dust capacity 200 g D Ordering information Our regional sales organization will help you to select the optimum device configuration. 8016639/2013-09 Dust measuring devices SICK D-85
FW101 Ex Scattered light dust measuring devices Dimensional drawings Sender/receiver unit FWSE101 Ex 141 124 435/735 Dimensions in mm Ø 60 200 160 234 300/600 55 Ø 53 Connection unit AK1-Ex 184 180 210 145 D 493 230 Ø 14 210 126 D-86 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FW101 Ex Connection unit AK1-Ex22 300 260 350 160 200 250 155 Purge air unit SLV5 2BH1300, Ex 2/3G Purge air unit SLV5 2BH1300, Ex 2/3D Ø 10 D 550 470 40 40 470 128 550 258 8016639/2013-09 Dust measuring devices SICK D-87
FW101 Ex Scattered light dust measuring devices Mounting flange, D i =70.2 mm 45 45 M10 76 70,2 M10 100 130 L = 130/240/500 Weather hood for sender/receiver unit 239 360 D 492 365 Weather hood for purge air unit SLV4/SLV5 255 550 550 340 605 D-88 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FW101 Ex D 8016639/2013-09 Dust measuring devices SICK D-89
ross-reference product family overview FW102 Scattered light dust measuring devices Effective monitoring of dust concentrations with scattered light D Product description The FW102 is used for continuous measuring of low to medium dust concentrations. It takes its measurements independent of gas velocity, humidity, and particle charge. The probe design of the FW102 is particularly advantageous. At a glance Automatic monitoring of zero and reference point Your benefits One-sided installation Mounted on one side of the gas duct, it needs neither mechanical adjustment nor alignment on dust-free measuring distance. Optional evaluation unit for connection and remote maintenance of up to three FW102 measuring devices Easy mounting Additional information Fields of application............d-91 Detailed technical data..........d-91 Ordering information............d-93 Dimensional drawings..........d-94 -- www.mysick.com/en/fw102 For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. D-90 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FW102 Fields of application Clean gas monitoring downstream of filter plants Monitoring of cloth filters for broken filters Dust monitoring in grinding plants and dosing systems Protection of flue gas desulfurization plants against excess dust load Monitoring and control of air supply and exhaust air installations Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System FW102 Measured variables TÜV-approved measured values Measurement principle Spectral range Measuring ranges Dust concentration Certified measuring ranges Dust concentration Response time Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Dust concentration Scattered light forward 640 nm... 660 nm Laser, protection class 2, power < 1 mw 0... 5 mg/m³ / 0... 200 mg/m³ Measuring ranges freely selectable Higher measuring ranges on request 0... 20 mg/m³ 0.1 s... 600 s Freely configurable Accuracy ± 2 % of the measuring range final value Process temperature 20 C... +220 C Process pressure With connection unit with integrated purge air supply: 50 hpa... 10 hpa With external purge air unit: 50 hpa... 70 hpa With instrument air (from customer): 50 hpa... 1,000 hpa Process gas humidity Non-condensing Duct diameter 150 mm Conformity TA-Luft (Prevention of Air Pollution) 27. BImSchV (Traffic Noise Protection) Electrical safety CE Test functions Automatic control cycle for zero point and reference point Options External purge air unit D Sender/receiver unit FWSE102 Description Analyzer unit with measuring probe Ambient temperature 20 C... +50 C Enclosure rating IP 65 Dimensions (W x H x D) 150 mm x 150 mm x 440 mm Weight 2.7 kg Electrical connection Voltage 24 V Supply via connection unit Power consumption 4 W 8016639/2013-09 Dust measuring devices SICK D-91
FW102 Scattered light dust measuring devices Connection unit AK1-N Description Ambient temperature 20 C... +45 C Enclosure rating IP 65 Analog outputs Digital outputs Digital inputs Unit for connecting data cables and power supply for system components 1 output: 0/2/4... 20 ma, 750 Ω Electrically isolated, second optional output 3 relay contacts: 48 V, 1 A Volt-free; for operation/fault status signals, limit value, maintenance 1 input: Interfaces Bus protocol Display Dimensions (W x H x D) Weight Electrical connection Voltage Frequency Power consumption Volt-free; for maintenance switch RS-232 (service interface) CAN (option), for the connection of an evaluation unit Two-line LCD Option 200 mm x 220 mm x 130 mm (for details see dimensional drawings) 3.7 kg 100... 240 V Optional: 24 V DC ± 2 V 47... 63 Hz 15 W Connection unit AK1-P D Description Unit for connecting data cables and power supply for system components; with integrated purge air supply Ambient temperature 20 C... +45 C Suction temperature for the purge air Enclosure rating IP 65 Analog outputs 1 output: 0/2/4... 20 ma, 750 Ω Electrically isolated, second optional output Digital outputs 3 relay contacts: 48 V, 1 A Volt-free; for operation/fault status signals, limit value, maintenance Digital inputs 1 input: Interfaces Bus protocol Display Dimensions (W x H x D) Weight Electrical connection Voltage Frequency Power consumption Volt-free; for maintenance switch RS-232 (service interface) CAN (option), for the connection of an evaluation unit Two-line LCD Option 300 mm x 420 mm x 220 mm (for details see dimensional drawings) 13.5 kg 100... 240 V Optional: 24 V DC ± 2 V 47... 63 Hz 70 W D-92 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FW102 Purge air unit SLV4 2BH1300, 3-ph Description Unit supplying dust-free air for purging optical surfaces Sample quantity 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) 550 mm x 550 mm x 258 mm (for details see dimensional drawings) Weight 18 kg Electrical connection 3-phase, Δ: 200... 240 V / 50 Hz / 2.6 A / 350 W 3-phase, Δ: 220... 275 V / 60 Hz / 2.3 A / 450 W 3-phase, Y: 345... 415 V / 50 Hz / 1.5 A / 350 W 3-phase, Y: 380... 480 V / 60 Hz / 1.3 A / 450 W Auxiliary connections Purge air: 40 mm Test functions Low pressure warning device (switching point 35 hpa) Integrated components Two-stage air filter, Europiclon type, dust capacity 200 g Ordering information Our regional sales organization will help you to select the optimum device configuration. D 8016639/2013-09 Dust measuring devices SICK D-93
FW102 Scattered light dust measuring devices Dimensional drawings FW102 with 1" thread Dimensions in mm L1 Ø 25 150 81 L2 NL Nominal length L1 L2 180 50 179 280 150 79 All dimensions in mm FW102 with tri-clamp connection Ø 25 L1 Ø 25 150 D 81 L2 NL Nominal length L1 L2 180 50 179 280 150 79 All dimensions in mm Connection unit AK1-N 160 220 200 200 130 D-94 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FW102 Connection unit AK1-P 260 Ø 8 420 400 300 220 Mounting flange, tri-clamp Ø 50,5 Ø 43 Ø 34,8 Ø 38,1 D 44,5 Purge air unit SLV4 2BH1300, 3-ph Ø 10 550 470 40 40 470 128 550 258 8016639/2013-09 Dust measuring devices SICK D-95
FW102 Scattered light dust measuring devices Weather hood for purge air unit SLV4/SLV5 255 550 550 340 605 D D-96 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FW102 D 8016639/2013-09 Dust measuring devices SICK D-97
ross-reference product family overview FWE200 Scattered light dust measuring devices Extractive dust measuring system for wet gases D Product description The FWE200 dust measuring system is designed to measure dust concentrations in wet gases. The gas is extracted via a sampling probe and heated above dew point in a thermocyclone. All of the droplets contained in the gas are At a glance For very low to medium dust concentrations Gas sampling and return combined in one probe Your benefits Reliable dust measurement in wet gas Low-maintenance thanks to the absence of moving parts coming into contact with aggressive gas condensed and are thus unable to falsify the measurement result. The scattered light principle enables even minimal dust concentrations to be measured. Contamination check Automatic monitoring of zero and reference point Compact design for installation directly on the duct Additional information Fields of application............d-99 Detailed technical data..........d-99 Ordering information...........d-101 Dimensional drawings.........d-101 -- www.mysick.com/en/fwe200 For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. D-98 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FWE200 Fields of application Monitoring of wet scrubber facilities Measurement in saturated gas downstream of desulfurization plants Determination of dust concentrations in wet exhaust air Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System FWE200 Measured variables TÜV-approved measured values Measurement principle Spectral range Measuring ranges Dust concentration Certified measuring ranges Dust concentration Response time Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Dust concentration Scattered light forward 640 nm... 660 nm Laser, protection class 2, power < 1 mw 0... 5 mg/m³ / 0... 200 mg/m³ Measuring ranges freely selectable Higher measuring ranges on request 0... 15 mg/m³ / 0... 50 mg/m³ 0.1 s... 600 s Freely configurable Accuracy ± 2 % of the measuring range final value Process temperature PVDF probe: +120 C Hastelloy probe: +220 C Process pressure 20 hpa... 20 hpa Process gas velocity 4 m/s... 20 m/s Process gas humidity Max. 10 g/m³ liquid water without water vapor Ambient temperature 20 C... +50 C Conformity Approved for system requiring permission 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV (Traffic Noise Protection) TA-Luft (Prevention of Air Pollution) MCERTS Conforms to U.S. EPA PS-11 Electrical safety CE Enclosure rating System: IP 54 Electronics housing: IP 65 Analog outputs 1 output: 0/2/4... 20 ma, 750 Ω Electrically isolated, second optional output Digital outputs 4 relay contacts: 250 V, 1 A Preassigned for fault, warning, limit value, and maintenance Digital inputs 1 input: D Interfaces Operation Dimensions (W x H x D) Volt-free; for maintenance switch RS-232 (service interface) Menu-driven operation via control unit 730 mm x 830 mm x 340 mm (FWE200 measuring and control unit; for details see dimensional drawings) 8016639/2013-09 Dust measuring devices SICK D-99
FWE200 Scattered light dust measuring devices Weight Electrical connection Options Voltage Frequency Power consumption FWE200 measuring and control unit: 65 kg Sampling probe: 15 kg 115 V / 230 V 47... 63 Hz 2.5 kw Mounting frame FWE200 Purge air unit SLV4 2BH1300, 1-ph Description Sample quantity Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) Weight Electrical connection Auxiliary connections Test functions Integrated components Voltage Frequency Power consumption Power consumption Unit supplying dust-free air for purging optical surfaces 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter 550 mm x 550 mm x 258 mm (for details see dimensional drawings) 18 kg 230 V / 115 V 50 Hz / 60 Hz 6 A 450 W Purge air: 40 mm Low pressure warning device (switching point 35 hpa) Two-stage air filter, Europiclon type, dust capacity 200 g D D-100 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FWE200 Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Measuring and control unit FWE200 330 Dimensions in mm 830 650 Ø 14 650 725 200 D Sampling probe FWE200 140 250/850 600/1.200 Ø 200 Ø 32 Ø 50 Ø 15/20/25 Ø 240 8016639/2013-09 Dust measuring devices SICK D-101
FWE200 Scattered light dust measuring devices Mounting frame FWE200 650 650 470 140 1.970 1.855 470 1.180 1.000 D 500 450 Ø 15 800 Mounting flange, D i =125 mm 22,5 Ø 18 Ø 240 Ø 178 Ø 125 Ø 139,7 152 Ø 200 200 D-102 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FWE200 Purge air unit SLV4 2BH1300, 1-ph Ø 10 550 470 40 40 470 128 550 258 Weather hood for purge air unit SLV4/SLV5 255 550 D 550 340 605 8016639/2013-09 Dust measuring devices SICK D-103
ross-reference product family overview FWE200DH Scattered light dust measuring devices Extractive dust measuring system for wet gases D Product description The FWE200DH dust measuring system is designed to measure dust concentrations in wet gases. The gas is extracted via a sampling probe and heated above dew point in a thermocyclone. All of the droplets contained in the gas are At a glance For very low to medium dust concentrations Gas sampling and return combined in one probe Your benefits Reliable dust measurement in wet gas Low-maintenance thanks to the absence of moving parts coming into contact with aggressive gas. condensed and are thus unable to falsify the measurement result. The scattered light principle enables even minimal dust concentrations to be measured. Contamination check Automatic monitoring of zero and reference point Compact design for installation directly on the duct Additional information Fields of application...........d-105 Detailed technical data.........d-105 Ordering information...........d-107 Dimensional drawings.........d-107 -- www.mysick.com/en/fwe200dh For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. D-104 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FWE200DH Fields of application Monitoring of wet scrubber facilities Measurement in saturated gas downstream of desulfurization plants Determination of dust concentrations in wet exhaust air Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System FWE200DH Measured variables TÜV-approved measured values Measurement principle Spectral range Measuring ranges Dust concentration Scattered light intensity, dust concentration (according to gravimetric comparison measurement) Dust concentration Scattered light forward 640 nm... 660 nm Laser, protection class 2, power < 1 mw 0... 5 mg/m³ / 0... 200 mg/m³ Measuring ranges freely selectable Higher measuring ranges on request Response time 0.1 s... 600 s Freely configurable Accuracy ± 2 % of the measuring range final value Process temperature PVDF probe: +120 C Hastelloy probe: +220 C Process pressure With purge air unit SLV4 2BH1300: 20 hpa... 20 hpa With purge air unit SLV4 2BH1400: 40 hpa... 40 hpa Process gas velocity 8 m/s... 30 m/s Process gas humidity Max. 10 g/m³ liquid water without water vapor Ambient temperature 20 C... +50 C Optional: 40 C... +60 C Suction temperature for the purge air: 40 C... +50 C Conformity Approved for system requiring permission 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV (Traffic Noise Protection) TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 Conforms to U.S. EPA PS-11 Electrical safety CE Enclosure rating System: IP 54 Electronics housing: IP 65 Analog outputs 3 outputs: 0/2/4... 20 ma, 750 Ω Electrically isolated Analog inputs 4 inputs: 0... 20 ma Preassigned for pressure, temperature, humidity, and O 2 value Digital outputs 5 relay contacts: 250 V, 1 A Preassigned for fault, warning, maintenance, limit value, and control cycle, four additional optional outputs D 8016639/2013-09 Dust measuring devices SICK D-105
FWE200DH Scattered light dust measuring devices Digital inputs Interfaces Bus protocol Display Input Operation Dimensions (W x H x D) Weight Electrical connection Test functions Options Voltage Frequency Power consumption 4 inputs: Volt-free; four additional optional inputs RS-232 (service interface) USB Ethernet (option) PROFIBUS DP (option) MODBUS TCP (option) OPC (option) LDC and status LEDs Function keys Menu-driven operation via control unit 730 mm x 830 mm x 340 mm (FWE200DH measuring and control unit; for details see dimensional drawings) FWE200DH measuring and control unit: 65 kg Sampling probe: 15 kg 115 V / 230 V 47... 63 Hz 1.7 kw Automatic control cycle for zero point and reference point Contamination check Mounting frame FWE200DH Purge air unit SLV4 2BH1300, 1-ph D Description Unit supplying dust-free air for purging optical surfaces Sample quantity 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) 550 mm x 550 mm x 258 mm (for details see dimensional drawings) Weight 18 kg Electrical connection Voltage 230 V / 115 V Frequency 50 Hz / 60 Hz Power consumption 6 A Power consumption 450 W Auxiliary connections Purge air: 40 mm Test functions Low pressure warning device (switching point 35 hpa) Integrated components Two-stage air filter, Europiclon type, dust capacity 200 g Purge air unit SLV4 2BH1400, 1-ph Description Unit supplying dust-free air for purging optical surfaces Sample quantity 86 m³/h... 125 m³/h At 30 hpa counterpressure, dependent on vacuum in filter Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) 550 mm x 550 mm x 303.5 mm (for details see dimensional drawings) Weight 25 kg Electrical connection Voltage 230 V / 115 V D-106 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FWE200DH Auxiliary connections Test functions Integrated components Frequency Power consumption Power consumption 50 Hz 10.4 A 800 W Purge air: 40 mm Low pressure warning device (switching point 35 hpa) Two-stage air filter, Europiclon type, dust capacity 200 g Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Purge air unit SLV4 2BH1300, 1-ph Ø 10 Dimensions in mm 550 470 40 D 40 470 128 550 258 Purge air unit SLV4 2BH1400, 1-ph Ø 10 550 470 40 40 470 161 550 303,5 8016639/2013-09 Dust measuring devices SICK D-107
FWE200DH Scattered light dust measuring devices Measuring and control unit FWE200 815 783 285,5 722 Sampling probe FWE200DH 140 250/850 600/1.200 D Ø 200 Ø 32 Ø 50 Ø 15/20/25 Ø 240 D-108 Dust measuring devices SICK 8016639/2013-09
Scattered light dust measuring devices FWE200DH Mounting frame FWE200DH 650 650 470 1.870 1.855 500 140 470 1.180 1.000 450 Ø 15 800 D Mounting flange, D i =125 mm 22,5 Ø 18 Ø 240 Ø 178 Ø 125 Ø 139,7 152 Ø 200 200 8016639/2013-09 Dust measuring devices SICK D-109
Transmittance dust measuring devices Retaining an overview even at high dust concentrations E Transmittance dust measuring devices transmit light through the entire duct. The attenuation of the light indicates the dust concentration in the duct. The devices have been designed specifically for medium to high levels of dust concentration and large duct diameters. Therefore, they are as suitable for emissions and process monitoring as they are for monitoring applications in large production spaces. Your benefits Reliable detection even at high dust concentrations Easy installation and commissioning Convenient operation Suitable for small to large measuring distances Long maintenance intervals thanks to automatic self-monitoring Condition-based maintenance signal Measurements independent of gas velocity, humidity, and particle charge E-110 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices Transmittance dust measuring devices Product family overview........................................ E-112 E DUSTHUNTER C200.......................................... E-114 Two-in-one dust measuring device with transmittance and scattered light measurement DUSTHUNTER T50........................................... E-126 The transmissiometer for monitoring dust concentrations DUSTHUNTER T100.......................................... E-134 The type-approved transmissiometer for monitoring emissions DUSTHUNTER T200.......................................... E-144 The type approved transmissiometer with self-alignment function FW300 Ex................................................ E-154 The reliable dust measuring device for explosion areas 8016639/2013-09 Dust measuring devices SICK E-111
ross-reference product family overview Product family overview Transmittance dust measuring devices Product family overview DUSTHUNTER C200 Two-in-one dust measuring device with transmittance and scattered light measurement DUSTHUNTER T50 The transmissiometer for monitoring dust concentrations Technical data Measurement principles Transmittance measurement, scattered light forward Transmittance measurement Measuring components Transmittance, opacity, relative opacity, extinction, dust concentration (scattered light), dust concentration (transmittance), scattered light intensity TÜV-approved measured variables Measuring ranges Transmittance: 100... 90 % / 100... 0 % Opacity: 0... 10 % / 0... 100 % Relative opacity: 0... 10 % / 0... 100 % Extinction: 0... 0.045 / 0... 2 Dust concentration (scattered light): 0... 5 mg/m³ / 0... 200 mg/m³ Dust concentration (transmittance): 0... 200 mg/m³ / 0... 10,000 mg/m³ Remarks The transmittance measurement depends on measuring distance and dust properties Certified measuring ranges Dust concentration (scattered light): 0... 50 SI / 0... 5 SI / 0... 20 SI / 0... 100 SI / 0... 200 SI Dust concentration (transmittance): 0... 0.1 ext / 0... 0.05 ext / 0... 0.2 ext / 0... 0.5 ext / 0... 1 ext Transmittance, opacity, relative opacity, extinction, dust concentration Scattered light intensity, extinction Transmittance: 100... 50 % / 100... 0 % Opacity: 0... 50 % / 0... 100 % Relative opacity: 0... 50 % / 0... 100 % Extinction: 0... 0.3 / 0... 1 Dust concentration: 0... 200 mg/m³ / 0... 10,000 mg/m³ The measurement depends on measuring distance and dust properties Process temperature 40 C... +300 C 40 C... +600 C Process pressure With control unit MCU-P: 50 hpa... 2 hpa With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa With external purge air unit: 50 hpa... 30 hpa E At a glance Duct diameter Test functions With reflector/scattered light receiver DHC-R0: 0.5 m... 3 m With reflector/scattered light receiver DHC-R1: 2.5 m... 8 m Automatic self-test (linearity, contamination, drift, aging), contamination limit values: warning at 30 %, fault at 40 %, manual linearity test with reference filter 0.5 m... 2.5 m 2 m... 5 m 4 m... 8 m Automatic self-test (linearity, drift, aging), manual linearity test with reference filter Combination of transmittance and scattered light measurement For very low to high dust concentrations Automatic check of zero and reference point Double-sided contamination check and correction Automatic self-alignment For medium to large duct diameters For medium to high dust concentrations Automatic check of zero and reference point For small to medium measuring distances Detailed information --E-114 --E-126 E-112 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices Product family overview DUSTHUNTER T100 DUSTHUNTER T200 FW300 Ex The type-approved transmissiometer for monitoring emissions The type approved transmissiometer with self-alignment function The reliable dust measuring device for explosion areas Transmittance measurement Transmittance measurement Transmittance measurement Transmittance, opacity, relative opacity, extinction, dust concentration Transmittance, opacity, relative opacity, extinction, dust concentration Transmittance, opacity, extinction, dust concentration Dust concentration Dust concentration Transmittance: 100... 80 % / 100... 0 % Opacity: 0... 20 % / 0... 100 % Relative opacity: 0... 20 % / 0... 100 % Extinction: 0... 0.1 / 0... 2 Dust concentration: 0... 200 mg/m³ / 0... 10.000 mg/m³ Transmittance: 100... 90 % / 100... 0 % Opacity: 0... 10 % / 0... 100 % Relative opacity: 0... 10 % / 0... 100 % Extinction: 0... 0.045 / 0... 2 Dust concentration: 0... 200 mg/m³ / 0... 10.000 mg/m³ Transmittance: 100... 80 % / 100... 0 % Opacity: 0... 20 % / 0... 100 % Extinction: 0... 0.1 ext / 0... 2.5 ext Dust concentration: 0... 13 mg/m³ / 0... 12,000 mg/m³ The measurement depends on measuring distance and dust properties Dust concentration (transmittance): 0... 0.1 ext / 0... 0.05 ext / 0... 0.2 ext / 0... 0.5 ext / 0... 1 ext The measurement depends on measuring distance and dust properties Dust concentration (transmittance): 0... 0.1 ext / 0... 0.05 ext / 0... 0.2 ext / 0... 0.5 ext / 0... 1 ext The measurement depends on measuring distance and dust properties 40 C... +600 C 40 C... +600 C 0 C... +600 C With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa -50 hpa... 30 hpa 0.5 m... 2.5 m 2 m... 5 m 4 m... 12 m Automatic self-test (linearity, contamination, drift, aging), contamination limit values: warning at 20 %, fault at 30 %, manual linearity test with reference filter 0.5 m... 2.5 m 2 m... 5 m 4 m... 12 m Automatic self-test (linearity, contamination, drift, aging), contamination limit values: warning at 30 %, fault at 40 %, manual linearity test with reference filter 0.5 m... 2 m 1.5 m... 8 m Automatic self-test (linearity, drift, aging), manual linearity test with reference filter E For medium to high dust concentrations Integrated contamination check Automatic check of zero and reference point For small to large measuring distances Integrated contamination check for sender/receiver and reflector unit Automatic self-alignment of the optical modules Automatic check of zero and reference point For medium to high dust concentrations For small to large measuring distances For medium to high dust concentrations Automatic monitoring of zero and reference point Device versions for ATEX Zones 1, 2, and 22 For small to medium measuring distances --E-134 --E-144 --E-154 8016639/2013-09 Dust measuring devices SICK E-113
DUSTHUNTER C200 Transmittance dust measuring devices Two-in-one dust measuring device with transmittance and scattered light measurement Product description The DUSTHUNTER C200 is a type-approved measuring device which combines the benefits of the transmittance and scattered light measurement principles. This makes it ideal for detecting very low to high dust content. Automatic At a glance Combination of transmittance and scattered light measurement For very low to high dust concentrations Automatic check of zero and reference point self-alignment optimizes the position of the measuring beam and prevents erroneous measurements. Automatic checking of the zero and reference points as well as a contamination check are integrated into the device. Double-sided contamination check and correction Automatic self-alignment For medium to large duct diameters E Your benefits Suitable for highly fluctuating dust concentration levels Redundant measurements for application reliability Self-monitoring for low maintenance Fit for the future for decreasing limit values Type-approved to EN 15267 15267 approved 14181 approved Additional information Fields of application...........e-115 Detailed technical data.........e-115 Ordering information...........e-119 Dimensional drawings.........e-119 -- www.mysick.com/en/dusthunter_c200 For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. E-114 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER C200 Fields of application Emissions monitoring in power plants and waste incineration plants Monitoring of filter plants Measurements of dust concentration in flue gas and exhaust air ducts upstream and downstream of filter Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System DUSTHUNTER C200 Measured variables TÜV-approved measured variables Measurement principles Spectral range Measuring ranges Dust concentration (scattered light) Dust concentration (transmittance) Certified measuring ranges Dust concentration (scattered light) Dust concentration (transmittance) Response time Transmittance, opacity, relative opacity, extinction, dust concentration (scattered light), dust concentration (transmittance), scattered light intensity Scattered light intensity, extinction Transmittance measurement, scattered light forward Transmittance measurement: 450 nm... 700 nm Scattered light forward: 640 nm... 660 nm Laser, protection class 2, power < 1 mw Transmittance 100... 90 % / 100... 0 % Opacity 0... 10 % / 0... 100 % Relative opacity 0... 10 % / 0... 100 % Extinction 0... 0.045 / 0... 2 0... 5 mg/m³ / 0... 200 mg/m³ 0... 200 mg/m³ / 0... 10,000 mg/m³ The transmittance measurement depends on measuring distance and dust properties 0... 50 SI / 0... 5 SI / 0... 20 SI / 0... 100 SI / 0... 200 SI 0... 0.1 ext / 0... 0.05 ext / 0... 0.2 ext / 0... 0.5 ext / 0... 1 ext 1 s... 600 s configurable Accuracy ± 2 % Process temperature 40 C... +300 C Process pressure With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa Process gas humidity Non-condensing Duct diameter With reflector/scattered light receiver DHC-R0: 0.5 m... 3 m With reflector/scattered light receiver DHC-R1: 2.5 m... 8 m Conformity Approved for system requiring permission 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV (Traffic Noise Protection) EN 14181 EN 15267 TA-Luft (Prevention of Air Pollution) MCERTS Conforms to U.S. EPA PS-1 Conforms to U.S. EPA PS-11 Electrical safety CE Corrective functions Automatic self-alignment Test functions Automatic self-test (linearity, contamination, drift, aging) Contamination limit values: warning at 30 %, fault at 40 % Manual linearity test with reference filter E 8016639/2013-09 Dust measuring devices SICK E-115
DUSTHUNTER C200 Transmittance dust measuring devices Sender/receiver unit DHC-T Description Ambient temperature 40 C... +60 C Enclosure rating IP 66 Dimensions (W x H x D) Weight Electrical connection Auxiliary connections Voltage Power consumption Analyzer unit of the cross-duct measuring system 212 mm x 241 mm x 429 mm (for details see dimensional drawings) 9.5 kg 24 V Supply via control unit 17 W Purge air Reflector/scattered light receiver DHC-R0 Description Combination of reflector unit for transmittance measurement and receiver for scattered light measurement Measuring distances 0.1 m effective measuring distance for scattered light measurement Ambient temperature 40 C... +60 C Enclosure rating IP 66 Dimensions (W x H x D) 212 mm x 241 mm x 420 mm (for details see dimensional drawings) Weight 8 kg Auxiliary connections Purge air Reflector/scattered light receiver DHC-R1 E Description Combination of reflector unit for transmittance measurement and receiver for scattered light measurement Measuring distances 0.3 m effective measuring distance for scattered light measurement Ambient temperature 40 C... +60 C Enclosure rating IP 66 Dimensions (W x H x D) 265 mm x 308 mm x 549 mm (for details see dimensional drawings) Weight 12 kg Auxiliary connections Purge air Control unit MCU-N Description Unit to control the system components and to evaluate and output the data provided by them Ambient temperature 40 C... +60 C Enclosure rating IP 66 Analog outputs 3 outputs: 0/2/4... 20 ma, 750 Ω electrically isolated; two additional outputs if using I/O modules (option) Analog inputs 2 inputs: 0... 20 ma not electrically isolated; two additional inputs if using I/O modules (option) Digital outputs 5 relay contacts: 48 V, 1 A Volt-free; for status signals Digital inputs 4 volt-free contacts Interfaces USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) E-116 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER C200 Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Options Control unit MCU-P Voltage Frequency Power consumption Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) LCD Status LEDs: "Power", "Maintenance", and "Fault" Via LCD or SOPAS ET software 210 mm x 340 mm x 120 mm 3.7 kg 90... 250 V 24 V DC version available as an option 47... 63 Hz 15 W Interface module(s) I/O module(s) Description Unit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit. Sample quantity 20 m³/h Ambient temperature 40 C... +45 C Suction temperature for the purge air Enclosure rating IP 66 Analog outputs 3 outputs: 0/2/4... 20 ma, 750 Ω electrically isolated; two additional outputs if using I/O modules (option) Analog inputs 2 inputs: 0... 20 ma not electrically isolated; two additional inputs if using I/O modules (option) Digital outputs 5 relay contacts: 48 V, 1 A Volt-free; for status signals Digital inputs 4 volt-free contacts Interfaces USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Bus protocol Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) Display LCD Status LEDs: "Power", "Maintenance", and "Fault" Operation Via LCD or SOPAS ET software Dimensions (W x H x D) 300 mm x 455 mm x 220 mm Weight 13.5 kg Electrical connection Voltage 90... 250 V 24 V DC version available as an option Frequency 47... 63 Hz Power consumption 70 W Auxiliary connections Purge air Options Interface module(s) I/O module(s) E 8016639/2013-09 Dust measuring devices SICK E-117
DUSTHUNTER C200 Transmittance dust measuring devices Purge air unit SLV4 2BH1300, 3-ph Description Sample quantity Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) Weight Electrical connection Auxiliary connections Test functions Integrated components Unit supplying dust-free air for purging optical surfaces 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter 550 mm x 550 mm x 258 mm (for details see dimensional drawings) 18 kg 3-phase, Δ: 200... 240 V / 50 Hz / 2.6 A / 350 W 3-phase, Δ: 220... 275 V / 60 Hz / 2.3 A / 450 W 3-phase, Y: 345... 415 V / 50 Hz / 1.5 A / 350 W 3-phase, Y: 380... 480 V / 60 Hz / 1.3 A / 450 W Purge air: 40 mm Low pressure warning device (switching point 35 hpa) Two-stage air filter, Europiclon type, dust capacity 200 g E E-118 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER C200 Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Sender/receiver unit DHC-T 104 309 429 401 Dimensions in mm 65 Ø 126 13 Ø 11 Ø 100 241 200 205 208 125 168 355 212 208 202 Ø 60 E 8016639/2013-09 Dust measuring devices SICK E-119
DUSTHUNTER C200 Transmittance dust measuring devices Reflector/scattered light receiver DHC-R0 99 420 367 339 257 65 Ø 11 208 Ø 100 241 200 212 208 202 13 60 103 298 205 Ø 126 Ø 61 E E-120 Dust measuring devices SICK 8016639/2013-09
Meas Transmittance dust measuring devices DUSTHUNTER C200 Reflector/scattered light receiver DHC-R1 265 Ø 15 402 352 257 308 241 200 13 97 225 103 299 550 212 208 202 Ø 144 Ø 239 205 Ø 80 Control unit MCU-N 210 160 120 340 320 300 E 8016639/2013-09 Dust measuring devices SICK E-121
Meas DUSTHUNTER C200 Transmittance dust measuring devices Control unit MCU-P 260 Ø 8 455 420 400 300 220 Mounting flange, D i =70.2 mm 45 45 M10 76 70,2 M10 100 130 L = 130/240/500 E E-122 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER C200 Mounting flange, D i =152 mm 45 45 M12 159 152 M12 225 L = 240/500 265 Purge air unit SLV4 2BH1300, 3-ph Ø 10 550 470 40 40 470 128 550 258 E 8016639/2013-09 Dust measuring devices SICK E-123
DUSTHUNTER C200 Transmittance dust measuring devices Weather hood for sender/receiver unit 239 360 492 365 Weather hood for DHSB/DHSF-R1/DHC-R1 239 360 492 365 Weather hood for purge air unit SLV4/SLV5 255 E 550 550 340 605 E-124 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER C200 E 8016639/2013-09 Dust measuring devices SICK E-125
DUSTHUNTER T50 Transmittance dust measuring devices The transmissiometer for monitoring dust concentrations Product description At a glance For medium to high dust concentrations Automatic check of zero and reference point The DUSTHUNTER T50 is a cost-effective measuring device for detecting medium to high dust content in gases above the dew point. Transmittance is the basic measured variable. It can be used to calculate and output opacity and extinction as well as dust concentration according to gravimetric comparison measurements. For small to medium measuring distances Your benefits Easy installation, commissioning and operation Measurement not dependent on gas velocity, humidity, or particle load Self-monitoring for low maintenance E Additional information Fields of application...........e-127 Detailed technical data.........e-127 Ordering information...........e-130 Dimensional drawings.........e-130 -- www.mysick.com/en/dusthunter_t50 For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. E-126 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER T50 Fields of application Emissions monitoring in heating systems Monitoring of dust concentrations upstream of filter plants Dust concentration measurements in cement plants Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System DUSTHUNTER T50 Measured variables Transmittance, opacity, relative opacity, extinction, dust concentration Measurement principles Transmittance measurement Spectral range 450 nm... 700 nm Measuring ranges Transmittance 100... 50 % / 100... 0 % Opacity 0... 50 % / 0... 100 % Relative opacity 0... 50 % / 0... 100 % Extinction 0... 0.3 / 0... 1 Dust concentration 0... 200 mg/m³ / 0... 10,000 mg/m³ The measurement depends on measuring distance and dust properties Response time 1 s... 600 s Freely configurable Accuracy ± 2 % Process temperature 40 C... +600 C Process pressure With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa Process gas humidity Non-condensing Duct diameter 0.5 m... 2.5 m 2 m... 5 m 4 m... 8 m Electrical safety CE Test functions Automatic self-test (linearity, drift, aging) Manual linearity test with reference filter Options External purge air unit Sender/receiver unit DHC-T00 Description Analyzer unit of the cross-duct measuring system Ambient temperature 40 C... +60 C Enclosure rating IP 66 Dimensions (W x H x D) 198 mm x 216 mm x 398 mm (for details see dimensional drawings) Weight 5 kg Electrical connection Voltage 24 V Supply via control unit Power consumption 15 W E 8016639/2013-09 Dust measuring devices SICK E-127
DUSTHUNTER T50 Transmittance dust measuring devices Reflector unit DHT-R5x Description Reflector unit with triple reflector Enclosure rating IP 66 Dimensions (W x H x D) 126 mm x 131 mm x 139 mm (for details see dimensional drawings) Weight DHT-R50, DHT-R51: 1 kg Control unit MCU-N E Description Ambient temperature 40 C... +60 C Enclosure rating IP 66 Analog outputs Analog inputs Digital outputs Digital inputs Interfaces Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Options Unit to control the system components and to evaluate and output the data provided by them 1 output: 0/2/4... 20 ma, 750 Ω electrically isolated; two additional outputs if using I/O modules (option) 2 inputs: 0... 20 ma not electrically isolated; two additional inputs if using I/O modules (option) 5 relay contacts: 48 V, 1 A Volt-free; for status signals 4 volt-free contacts USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) LCD (option) Status LEDs: "Power", "Maintenance", and "Fault" Via LCD (option) or SOPAS ET software 210 mm x 340 mm x 120 mm 3.7 kg Voltage 90... 250 V 24 V DC version available as an option Frequency 47... 63 Hz Power consumption 15 W Interface module(s) I/O module(s) Control unit MCU-P Description Unit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit. Sample quantity 20 m³/h Ambient temperature 40 C... +45 C Suction temperature for the purge air Enclosure rating IP 66 Analog outputs 1 output: 0/2/4... 20 ma, 750 Ω electrically isolated; two additional outputs if using I/O modules (option) Analog inputs 2 inputs: 0... 20 ma not electrically isolated; two additional inputs if using I/O modules (option) E-128 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER T50 Digital outputs Digital inputs Interfaces Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Auxiliary connections Options Voltage Frequency Power consumption 5 relay contacts: 48 V, 1 A Volt-free; for status signals 4 volt-free contacts USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) LCD (option) Status LEDs: "Power", "Maintenance", and "Fault" Via LCD (option) or SOPAS ET software 300 mm x 455 mm x 220 mm 13.5 kg 90... 250 V 24 V DC version available as an option 47... 63 Hz 70 W Purge air Interface module(s) I/O module(s) Purge air unit SLV4 2BH1300, 3-ph Description Unit supplying dust-free air for purging optical surfaces Sample quantity 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) 550 mm x 550 mm x 258 mm (for details see dimensional drawings) Weight 18 kg Electrical connection 3-phase, Δ: 200... 240 V / 50 Hz / 2.6 A / 350 W 3-phase, Δ: 220... 275 V / 60 Hz / 2.3 A / 450 W 3-phase, Y: 345... 415 V / 50 Hz / 1.5 A / 350 W 3-phase, Y: 380... 480 V / 60 Hz / 1.3 A / 450 W Auxiliary connections Purge air: 40 mm Test functions Low pressure warning device (switching point 35 hpa) Integrated components Two-stage air filter, Europiclon type, dust capacity 200 g E 8016639/2013-09 Dust measuring devices SICK E-129
DUSTHUNTER T50 Transmittance dust measuring devices Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Sender/receiver unit DHC-T00 90 278 370 398 Dimensions in mm 65 Ø 126 5 Ø 100 216 175 Ø 11 85 136 324 198 180 170 Ø 60 Reflector unit DHT-R5x 139 E Ø 100 28 124 68 Ø 126 Ø 80 Ø 11 76 E-130 Dust measuring devices SICK 8016639/2013-09
Meas Meas Transmittance dust measuring devices DUSTHUNTER T50 Control unit MCU-N 210 160 120 340 320 300 Control unit MCU-P 260 Ø 8 455 420 400 300 220 E 8016639/2013-09 Dust measuring devices SICK E-131
DUSTHUNTER T50 Transmittance dust measuring devices Mounting flange, D i =70.2 mm 45 45 M10 76 70,2 M10 100 130 L = 130/240/500 Purge air unit SLV4 2BH1300, 3-ph Ø 10 550 470 40 40 470 128 550 258 E Weather hood for sender/receiver unit 239 360 492 365 E-132 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER T50 Weather hood for purge air unit SLV4/SLV5 255 550 550 340 605 E 8016639/2013-09 Dust measuring devices SICK E-133
DUSTHUNTER T100 Transmittance dust measuring devices The type-approved transmissiometer for monitoring emissions Product description At a glance For medium to high dust concentrations Integrated contamination check Your benefits Easy installation, commissioning and operation Measurement not dependent on gas velocity, humidity, or particle load Self-monitoring for low maintenance The DUSTHUNTER T100 is a measuring device for detecting medium to high dust content. Transmittance is the basic measured variable. Opacity and extinction can be calculated and output along with dust concentration according to gravimetric comparison measurements. The measuring system features an integrated contamination check. The DUSTHUNTER T100 is type-approved to EN 15267-3. Automatic check of zero and reference point For small to large measuring distances Type-approved to EN 15267 E 15267 approved 14181 approved Additional information Fields of application...........e-135 Detailed technical data.........e-135 Ordering information...........e-138 Dimensional drawings.........e-138 -- www.mysick.com/en/dusthunter_t100 For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. E-134 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER T100 Fields of application Emissions monitoring in power plants and waste incineration plants Monitoring of filter plants Monitoring of dust load in factories Control of air supply and exhaust air installations Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System DUSTHUNTER T100 Measured variables Transmittance, opacity, relative opacity, extinction, dust concentration TÜV-approved measured variables Dust concentration Measurement principles Transmittance measurement Spectral range 450 nm... 700 nm Measuring ranges Transmittance 100... 80 % / 100... 0 % Opacity 0... 20 % / 0... 100 % Relative opacity 0... 20 % / 0... 100 % Extinction 0... 0.1 / 0... 2 Dust concentration 0... 200 mg/m³ / 0... 10,000 mg/m³ The measurement depends on measuring distance and dust properties Certified measuring ranges Dust concentration (transmittance) 0... 0.1 ext / 0... 0.05 ext / 0... 0.2 ext / 0... 0.5 ext / 0... 1 ext Response time 1 s... 600 s Freely configurable Accuracy ± 2 % Process temperature 40 C... +600 C Process pressure With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa Process gas humidity Non-condensing Duct diameter 0.5 m... 2.5 m 2 m... 5 m 4 m... 12 m Conformity Approved for system requiring permission 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV (Traffic Noise Protection) EN 15267 EN 14181 MCERTS TA-Luft (Prevention of Air Pollution) Electrical safety CE Test functions Automatic self-test (linearity, contamination, drift, aging) Contamination limit values: warning at 20 %, fault at 30 % Manual linearity test with reference filter Options External purge air unit E 8016639/2013-09 Dust measuring devices SICK E-135
DUSTHUNTER T100 Transmittance dust measuring devices Sender/receiver unit DHT-T10 and DHT-T21 Description Analyzer unit of the cross-duct measuring system Ambient temperature 40 C... +60 C Enclosure rating IP 66 Dimensions (W x H x D) 212 mm x 241 mm x 429 mm (for details see dimensional drawings) Weight 6.5 kg Electrical connection Voltage 24 V Supply via control unit Power consumption 15 W Reflector unit DHT-R0x and DHT-R1x Description Reflector unit with triple reflector Enclosure rating IP 66 Dimensions (W x H x D) 212 mm x 241 mm x 364 mm (for details see dimensional drawings) Weight DHT-R00, DHT-R01, DHT-R02: 3 kg Control unit MCU-N E Description Ambient temperature 40 C... +60 C Enclosure rating IP 66 Analog outputs Analog inputs Digital outputs Digital inputs Interfaces Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Options Unit to control the system components and to evaluate and output the data provided by them 3 outputs: 0/2/4... 20 ma, 750 Ω electrically isolated; two additional outputs if using I/O modules (option) 2 inputs: 0... 20 ma not electrically isolated; two additional inputs if using I/O modules (option) 5 relay contacts: 48 V, 1 A Volt-free; for status signals 4 volt-free contacts USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) LCD Status LEDs: "Power", "Maintenance", and "Fault" Via LCD or SOPAS ET software 210 mm x 340 mm x 120 mm 3.7 kg Voltage 90... 250 V 24 V DC version available as an option Frequency 47... 63 Hz Power consumption 15 W Interface module(s) I/O module(s) E-136 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER T100 Control unit MCU-P Description Unit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit. Sample quantity 20 m³/h Ambient temperature 40 C... +45 C Suction temperature for the purge air Enclosure rating IP 66 Analog outputs 3 outputs: 0/2/4... 20 ma, 750 Ω electrically isolated; two additional outputs if using I/O modules (option) Analog inputs 2 inputs: 0... 20 ma not electrically isolated; two additional inputs if using I/O modules (option) Digital outputs 5 relay contacts: 48 V, 1 A Volt-free; for status signals Digital inputs 4 volt-free contacts Interfaces USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Bus protocol Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) Display LCD Status LEDs: "Power", "Maintenance", and "Fault" Operation Via LCD or SOPAS ET software Dimensions (W x H x D) 300 mm x 455 mm x 220 mm Weight 13.5 kg Electrical connection Voltage 90... 250 V 24 V DC version available as an option Frequency 47... 63 Hz Power consumption 70 W Auxiliary connections Purge air Options Interface module(s) I/O module(s) Purge air unit SLV4 2BH1300, 3-ph E Description Unit supplying dust-free air for purging optical surfaces Sample quantity 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) 550 mm x 550 mm x 258 mm (for details see dimensional drawings) Weight 18 kg Electrical connection 8016639/2013-09 Dust measuring devices SICK E-137
DUSTHUNTER T100 Transmittance dust measuring devices Auxiliary connections Test functions Integrated components 3-phase, Δ: 200... 240 V / 50 Hz / 2.6 A / 350 W 3-phase, Δ: 220... 275 V / 60 Hz / 2.3 A / 450 W 3-phase, Y: 345... 415 V / 50 Hz / 1.5 A / 350 W 3-phase, Y: 380... 480 V / 60 Hz / 1.3 A / 450 W Purge air: 40 mm Low pressure warning device (switching point 35 hpa) Two-stage air filter, Europiclon type, dust capacity 200 g Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Sender/receiver unit DHT-T10 and DHT-T21 104 309 429 401 Dimensions in mm 65 Ø 126 13 Ø 11 Ø 100 241 200 205 208 125 168 355 Ø 60 E 212 208 202 E-138 Dust measuring devices SICK 8016639/2013-09
Meas Transmittance dust measuring devices DUSTHUNTER T100 Reflector unit DHT-R0x and DHT-R1x 104 364 336 244 65 Ø 126 Ø 11 208 Ø 100 241 200 212 208 202 13 60 103 290 205 Ø 60 Control unit MCU-N 210 160 120 340 320 300 E 8016639/2013-09 Dust measuring devices SICK E-139
Meas DUSTHUNTER T100 Transmittance dust measuring devices Control unit MCU-P 260 Ø 8 455 420 400 300 220 Mounting flange, D i =70.2 mm 45 45 M10 76 70,2 M10 100 130 L = 130/240/500 E E-140 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER T100 Purge air unit SLV4 2BH1300, 3-ph Ø 10 550 470 40 40 470 128 550 258 Weather hood for sender/receiver unit 239 360 492 365 E 8016639/2013-09 Dust measuring devices SICK E-141
DUSTHUNTER T100 Transmittance dust measuring devices Weather hood for purge air unit SLV4/SLV5 255 550 550 340 605 E E-142 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER T100 E 8016639/2013-09 Dust measuring devices SICK E-143
DUSTHUNTER T200 Transmittance dust measuring devices The type approved transmissiometer with self-alignment function E Product description The DUSTHUNTER T200 is a measuring device for detecting medium to high dust content. Transmittance is the basic measured variable. Opacity and extinction can be calculated and output along with dust concentration according to gravimetric comparison At a glance Integrated contamination check for sender/receiver and reflector unit Automatic self-alignment of the optical modules Automatic check of zero and reference point Your benefits Easy installation, commissioning and operation Measurement not dependent on gas velocity, humidity, or particle load measurements. It also features an integrated contamination check for sender/receiver and reflector unit and automatic self-alignment of the optical modules. The DUSTHUNTER T200 is type-approved to EN 15267. For medium to high dust concentrations For small to large measuring distances Self-monitoring and contamination check for low maintenance Type-approved to EN 15267 15267 approved 14181 approved Additional information Fields of application...........e-145 Detailed technical data.........e-145 Ordering information...........e-148 Dimensional drawings.........e-148 -- www.mysick.com/en/dusthunter_t200 For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. E-144 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER T200 Fields of application Emissions monitoring in power plants and waste incineration plants Monitoring of filter plants Monitoring of dust load in factories Control of air supply and exhaust air installations Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System DUSTHUNTER T200 Measured variables Transmittance, opacity, relative opacity, extinction, dust concentration TÜV-approved measured variables Dust concentration Measurement principles Transmittance measurement Spectral range 450 nm... 700 nm Measuring distances 0.5 m... 2.5 m 2 m... 5 m 4 m... 12 m Measuring ranges Transmittance 100... 90 % / 100... 0 % Opacity 0... 10 % / 0... 100 % Relative opacity 0... 10 % / 0... 100 % Extinction 0... 0.045 / 0... 2 Dust concentration 0... 200 mg/m³ / 0... 10,000 mg/m³ The measurement depends on measuring distance and dust properties Certified measuring ranges Dust concentration (transmittance) 0... 0.1 ext / 0... 0.05 ext / 0... 0.2 ext / 0... 0.5 ext / 0... 1 ext Response time 1 s... 600 s Freely configurable Accuracy ± 2 % Process temperature 40 C... +600 C Process pressure With control unit MCU-P: 50 hpa... 2 hpa With external purge air unit: 50 hpa... 30 hpa Process gas humidity Non-condensing Duct diameter 0.5 m... 2.5 m 2 m... 5 m 4 m... 12 m Conformity Approved for system requiring permission 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV (Traffic Noise Protection) EN 15267 EN 14181 MCERTS TA-Luft (Prevention of Air Pollution) Conforms to U.S. EPA PS-11 Electrical safety CE Corrective functions Automatic self-alignment Test functions Automatic self-test (linearity, contamination, drift, aging) Contamination limit values: warning at 30 %, fault at 40 % Manual linearity test with reference filter Options External purge air unit E 8016639/2013-09 Dust measuring devices SICK E-145
DUSTHUNTER T200 Transmittance dust measuring devices Sender/receiver unit DHT-T10 and DHT-T21 Description Analyzer unit of the cross-duct measuring system Ambient temperature 40 C... +60 C Enclosure rating IP 66 Dimensions (W x H x D) 212 mm x 241 mm x 429 mm (for details see dimensional drawings) Weight 10 kg Electrical connection Voltage 24 V Supply via control unit Power consumption 15 W Reflector unit DHT-R0x and DHT-R1 Description Reflector unit with triple reflector Enclosure rating IP 66 Dimensions (W x H x D) 212 mm x 241 mm x 364 mm (for details see dimensional drawings) Weight DHT-R10, DHT-R11, DHT-R12: 5 kg Control unit MCU-N E Description Ambient temperature 40 C... +60 C Enclosure rating IP 66 Analog outputs Analog inputs Digital outputs Digital inputs Interfaces Bus protocol Display Operation Dimensions (W x H x D) Weight Electrical connection Options Unit to control the system components and to evaluate and output the data provided by them 3 outputs: 0/2/4... 20 ma, 750 Ω electrically isolated; two additional outputs if using I/O modules (option) 2 inputs: 0... 20 ma not electrically isolated; two additional inputs if using I/O modules (option) 5 relay contacts: 48 V, 1 A Volt-free; for status signals 4 volt-free contacts USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) LCD Status LEDs: "Power", "Maintenance", and "Fault" Via LCD or SOPAS ET software 210 mm x 340 mm x 120 mm 3.7 kg Voltage 90... 250 V 24 V DC version available as an option Frequency 47... 63 Hz Power consumption 15 W Interface module(s) I/O module(s) E-146 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER T200 Control unit MCU-P Description Unit to control the system components and to evaluate and output the data provided by them. With integrated purge air unit. Sample quantity 20 m³/h Ambient temperature 40 C... +45 C Suction temperature for the purge air Enclosure rating IP 66 Analog outputs 3 outputs: 0/2/4... 20 ma, 750 Ω electrically isolated; two additional outputs if using I/O modules (option) Analog inputs 2 inputs: 0... 20 ma not electrically isolated; two additional inputs if using I/O modules (option) Digital outputs 5 relay contacts: 48 V, 1 A Volt-free; for status signals Digital inputs 4 volt-free contacts Interfaces USB (service interface) RS-232 (service interface) RS-485 (via optional interface module) Interface module (option) Bus protocol Ethernet TCP/IP (via optional interface module) MODBUS (via optional interface module) PROFIBUS DP (via optional interface module) Display LCD Status LEDs: "Power", "Maintenance", and "Fault" Operation Via LCD or SOPAS ET software Dimensions (W x H x D) 300 mm x 455 mm x 220 mm Weight 13.5 kg Electrical connection Voltage 90... 250 V 24 V DC version available as an option Frequency 47... 63 Hz Power consumption 70 W Auxiliary connections Purge air Options Interface module(s) I/O module(s) E 8016639/2013-09 Dust measuring devices SICK E-147
DUSTHUNTER T200 Transmittance dust measuring devices Purge air unit SLV4 2BH1300, 3-ph Description Sample quantity Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) Weight Electrical connection Auxiliary connections Test functions Integrated components Unit supplying dust-free air for purging optical surfaces 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter 550 mm x 550 mm x 258 mm (for details see dimensional drawings) 18 kg 3-phase, Δ: 200... 240 V / 50 Hz / 2.6 A / 350 W 3-phase, Δ: 275 V / 60 Hz / 2.3 A / 450 W 3-phase, Y: 345... 415 V / 50 Hz / 1.5 A / 350 W 3-phase, Y: 380... 480 V / 60 Hz / 1.3 A / 450 W Purge air: 40 mm Low pressure warning device (switching point 35 hpa) Two-stage air filter, Europiclon type, dust capacity 200 g Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Dimensions in mm Sender/receiver unit DHT-T10 and DHT-T21 429 104 309 401 65 Ø 126 13 Ø 11 Ø 100 241 200 205 E 208 125 168 355 212 208 202 Ø 60 E-148 Dust measuring devices SICK 8016639/2013-09
Meas Transmittance dust measuring devices DUSTHUNTER T200 Reflector unit DHT-R0x and DHT-R1x 104 364 336 244 65 Ø 126 Ø 11 208 Ø 100 241 200 212 208 202 13 60 103 290 205 Ø 60 Control unit MCU-N 210 160 120 340 320 300 E 8016639/2013-09 Dust measuring devices SICK E-149
Meas DUSTHUNTER T200 Transmittance dust measuring devices Control unit MCU-P 260 Ø 8 455 420 400 300 220 Mounting flange, D i =70.2 mm 45 45 M10 76 70,2 M10 100 130 L = 130/240/500 E E-150 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER T200 Purge air unit SLV4 2BH1300, 3-ph Ø 10 550 470 40 40 470 128 550 258 Weather hood for sender/receiver unit 239 360 492 365 E 8016639/2013-09 Dust measuring devices SICK E-151
DUSTHUNTER T200 Transmittance dust measuring devices Weather hood for purge air unit SLV4/SLV5 255 550 550 340 605 E E-152 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices DUSTHUNTER T200 E 8016639/2013-09 Dust measuring devices SICK E-153
FW300 Ex Transmittance dust measuring devices The reliable dust measuring device for explosion areas Product description Transmittance, opacity, extinction, and dust concentration - with the FW300 Ex, these measured variables can be freely selected. Be it sticky dusts, high gas temperatures, or fluctuating gas velocities, the FW300 Ex is capable of speedy At a glance For medium to high dust concentrations Automatic monitoring of zero and reference point Your benefits Easy operation Minimum maintenance required and highly accurate measurements even under the most difficult of conditions. For applications in explosion areas, a version housed inside a pressure-resistant enclosure and a dust-proof version are available. Device versions for ATEX Zones 1, 2, and 22 For small to medium measuring distances Measurements in explosion areas E Additional information Fields of application...........e-155 Detailed technical data.........e-155 Ordering information...........e-158 Dimensional drawings.........e-158 -- www.mysick.com/en/fw300_ex For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. E-154 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices FW300 Ex Fields of application Monitoring of filter plants for broken filters Monitoring of dust load in factories Emissions monitoring in industrial plants Measurements of dust emissions in waste dumps, quarries, and grinding plants Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System FW300 Ex Measured variables Transmittance, opacity, extinction, dust concentration Measurement principles Transmittance measurement Spectral range 640 nm... 660 nm Laser, protection class 2, power < 1 mw Measuring ranges Transmittance 100... 80 % / 100... 0 % Opacity 0... 20 % / 0... 100 % Extinction 0... 0.1 ext / 0... 2.5 ext Dust concentration 0... 13 mg/m³ / 0... 12,000 mg/m³ The measurement depends on measuring distance and dust properties Response time 0.1 s... 600 s Freely configurable Accuracy Transmittance: ± 0.4 % Opacity: ± 0.4 % Extinction: ± 0.002 ext Dust concentration: ± 2 % Process temperature 0 C... +600 C Process pressure 50 hpa... 30 hpa Process gas humidity Non-condensing Duct diameter 0.5 m... 2 m 1.5 m... 8 m Electrical safety CE Operation Via MEPA software Test functions Automatic self-test (linearity, drift, aging) Manual linearity test with reference filter Sender/receiver unit FWSE300 Ex E Description Analyzer unit of the cross-duct measuring system Ambient temperature 20 C... +40 C Ex approvals ATEX Zone 1 and 2: II 2G Ex IIC T6 Zone 22: II 3D Ex t IIIB T80 C Dc IP 54 Enclosure rating IP 65 Dimensions (W x H x D) 160 mm x 200 mm x 191 mm (for details see dimensional drawings) Weight 4.6 kg Electrical connection Voltage 24 V Supply via connection unit Power consumption 4 W 8016639/2013-09 Dust measuring devices SICK E-155
FW300 Ex Transmittance dust measuring devices Rotary reflector FW-R-055-D Description Ambient temperature 20 C... +40 C Ex approvals ATEX Enclosure rating IP 65 Dimensions (W x H x D) Weight Electrical connection Fixed reflector FW-R-055-F Reflector unit with glass triple reflector Zone 1 and 2: II 2G Ex IIC T6 Zone 22: II 3D Ex t IIIB T80 C Dc IP 54 160 mm x 200 mm x 191 mm (for details see dimensional drawings) 4.7 kg Voltage 24 Supply via connection unit Power consumption 12 W Description Reflector unit with glass triple reflector Ambient temperature 20 C... +40 C Enclosure rating IP 65 Dimensions (W x H x D) 80 mm x 80 mm x 34 mm (for details see dimensional drawings) Weight 0.4 kg Purge air fixture FW-V Description Dimensions (W x H x D) Weight Flange fixture with connection for the purge air 126 mm x 126 mm x 200 mm (for details see dimensional drawings) 1.4 kg Connection unit AK1-Ex E Description Unit for connecting data cables and power supply for system components; for use in explosion areas Ambient temperature 20 C... +40 C Ex approvals ATEX II 2G Ex de IIC T6 Enclosure rating IP 65 Analog outputs 1 output: 0/2/4... 20 ma, 750 Ω Electrically isolated, second output as option Digital outputs 3 relay contacts: 48 V, 1 A Volt-free; for operation/fault status signals, limit value, maintenance Digital inputs 1 input: Interfaces Bus protocol Display Dimensions (W x H x D) Weight Volt-free; for maintenance switch RS-232 (service interface) CAN (option), for the connection of an evaluation unit Two-line LCD 210 mm x 493 mm x 180 mm (for details see dimensional drawings) 13.3 kg E-156 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices FW300 Ex Electrical connection Voltage Frequency Power consumption 100... 240 V 47... 63 Hz 15 W Connection unit AK1-Ex22 Description Unit for connecting data cables and power supply for system components; for use in dust explosion areas Ambient temperature 20 C... +40 C Ex approvals ATEX II 2D Ex td A21 T80 C IP 6X Enclosure rating IP 65 Analog outputs 1 output: 0/2/4... 20 ma, 750 Ω Electrically isolated, second output as option Digital outputs 3 relay contacts: 48 V, 1 A Volt-free; for operation/fault status signals, limit value, maintenance Digital inputs 1 input: Interfaces Bus protocol Display Dimensions (W x H x D) Weight Electrical connection Voltage Frequency Power consumption Volt-free; for maintenance switch RS-232 (service interface) CAN (option), for the connection of an evaluation unit Two-line LCD 200 mm x 300 mm x 155 mm (for details see dimensional drawings) 4.9 kg 100... 240 V Optional: 24 V DC ± 2 V 47... 63 Hz 15 W Purge air unit SLV5 2BH1300, Ex 2/3G Description Sample quantity Unit supplying dust-free air for purging optical surfaces; for use in explosion areas 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) 550 mm x 550 mm x 258 mm (for details see dimensional drawings) Weight 18 kg Electrical connection 3-phase, Δ: 230 V / 50 Hz / 2.4 A / 550 W 3-phase, Y: 400 V / 50 Hz / 1.4 A / 550 W Auxiliary connections Purge air: 40 mm Test functions Low pressure warning device (switching point 35 hpa) Integrated components Two-stage air filter, Europiclon type, dust capacity 200 g E 8016639/2013-09 Dust measuring devices SICK E-157
FW300 Ex Transmittance dust measuring devices Purge air unit SLV5 2BH1300, Ex 2/3D Description Sample quantity Ambient temperature 20 C... +40 C Enclosure rating IP 54 Dimensions (W x H x D) Weight Electrical connection Auxiliary connections Test functions Integrated components Unit supplying dust-free air for purging optical surfaces; for use in dust explosion areas 38 m³/h... 63 m³/h At 30 hpa counterpressure, dependent on vacuum in filter 550 mm x 550 mm x 258 mm (for details see dimensional drawings) 18 kg 3-phase, Δ: 230 V / 50 Hz / 2.4 A / 550 W 3-phase, Y: 400 V / 50 Hz / 1.4 A / 550 W Purge air: 40 mm Low pressure warning device (switching point 35 hpa) Two-stage air filter, Europiclon type, dust capacity 200 g Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings Sender/receiver unit FWSE300 Ex Rotary reflector FW-R-055-D 141 Fixed reflector FW-R-055-F Ø 69 Ø 80 Dimensions in mm 14 200 160 Ø 82 20 E 143 48 Purge air fixture FW-V 45 Ø 126 Ø 76 Ø 56 Ø 40 Ø 100 200 E-158 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices FW300 Ex Connection unit AK1-Ex 184 180 230 210 145 493 Ø 14 210 126 Connection unit AK1-Ex22 300 260 350 E 160 200 250 155 8016639/2013-09 Dust measuring devices SICK E-159
FW300 Ex Transmittance dust measuring devices Mounting flange, D i =70.2 mm 45 45 M10 76 70,2 M10 100 130 L = 130/240/500 Purge air unit SLV5 2BH1300, Ex 2/3G Purge air unit SLV5 2BH1300, Ex 2/3D Ø 10 550 470 40 E 40 470 128 550 Weather hood for sender/receiver unit 239 258 360 492 365 E-160 Dust measuring devices SICK 8016639/2013-09
Transmittance dust measuring devices FW300 Ex Weather hood for purge air unit SLV4/SLV5 255 550 550 340 605 E 8016639/2013-09 Dust measuring devices SICK E-161
Gravimetric dust measurement devices Straightforward design, precise measurement, fast result Gravimetric dust measurement devices extract a partial gas flow from the duct under defined conditions. The gas is passed through a filter to separate the dust particles. The filter is weighed to determine the dust quantity directly and thus calculate the concentration inside the duct. Gravimetric dust measurement is particularly suitable for the calibration of other dust measuring devices and for official comparison measurements. Your benefits High measurement accuracy even at low dust concentrations Easy single-person operation Automatic monitoring of gas samples Automatic data recording and system control Automatic storage and evaluation of the measuring values Measurement results are available immediately after the sample has been taken F F-162 Dust measuring devices SICK 8016639/2013-09
Gravimetric dust measurement devices Gravimetric dust measurement devices F Product family overview........................................ F-164 SHC500 Gravimat........................................... F-166 Mobile measuring system for gravimetric dust concentration measurements 8016639/2013-09 Dust measuring devices SICK F-163
ross-reference product family overview Product family overview Gravimetric dust measurement devices Product family overview SHC500 Gravimat Mobile measuring system for gravimetric dust concentration measurements Technical data Measuring components Dust concentration Measuring ranges Dust concentration: 0.1... 200 mg/m³ / 50... 50,000 mg/m³ Process temperature Without air cooling: +250 C With air cooling: +400 C High-temperature design: +600 C Process pressure 50 hpa... 50 hpa At a glance No dust loss due to optimized sampling system Automatic data recording and system control Isokinetic control in real time (SHC502 only) Automatic storage and evaluation of the measuring values Automatic measurement of the flow angle and detection of swirl effects Detailed information --F-166 F F-164 Dust measuring devices SICK 8016639/2013-09
Gravimetric dust measurement devices Product family overview F 8016639/2013-09 Dust measuring devices SICK F-165
SHC500 Gravimat Gravimetric dust measurement devices Mobile measuring system for gravimetric dust concentration measurements Product description The SHC500 Gravimat is used for gravimetric measurements for the calibration of dust measuring devices and for comparison measurements on filter plants. A partial gas flow is extracted isokinetically At a glance No dust loss due to optimized sampling system Automatic data recording and system control Isokinetic control in real time (SHC502 only) Your benefits High measurement accuracy even at low dust concentrations Measurement results are immediately available after sampling via a filter head probe. This is controlled automatically and in real time. The dust content is determined by weighing the dust collector mass before and after extraction. Automatic storage and evaluation of the measuring values Automatic measurement of the flow angle and detection of swirl effects Due to compact design and low number of components, only one person necessary for transport and operation F 13284-1 geprüft Additional information Fields of application........... F-167 Detailed technical data......... F-167 Ordering information........... F-168 Dimensional drawings......... F-168 -- www.mysick.com/en/shc500_gravimat For more information, simply enter the link or scan the QR code and get direct access to technical data, CAD design models, operating instructions, software, application examples, and much more. F-166 Dust measuring devices SICK 8016639/2013-09
Gravimetric dust measurement devices SHC500 Gravimat Fields of application Calibration of continuous dust measuring devices Compliance measurements at filter plants Occasional check measurements Flow and temperature profile measurements, determination of the flow direction Detailed technical data The detailed device specifications and performance data for the product may differ. They are dependent upon the prevailing application and customer specification. System SHC500 Gravimat Measured variables Dust concentration Sample quantity 0.5 m³/h... 2.4 m³/h Measuring ranges Dust concentration 0.1... 200 mg/m³ / 50... 50,000 mg/m³ Accuracy Volume flow measurement: ± 1 % of maximum throughput Process temperature Without air cooling: +250 C With air cooling: +400 C High-temperature design: +600 C Process pressure 50 hpa... 50 hpa Process gas velocity 2 m/s... 48 m/s Ambient temperature 10 C... +50 C Conformity EN 13284-1 Conforms to U.S. EPA GOST Electrical safety CE Auxiliaries Cooling air: 5 m³/h... 10 m³/h Automatic unit AE50x Description The automatic unit serves as the user interface and is responsible for data processing and output as well as control and monitoring functions Enclosure rating Closed: IP 65 Open: IP 54 Analog inputs 2 inputs: 0... 20 ma SHC502 only Interfaces RS-232 Display Four-line LCD Operation Via LCD and function keys Dimensions (W x H x D) 310 mm x 550 mm x 290 mm Weight 24 kg Electrical connection Voltage 115 V / 230 V Frequency 50 Hz / 60 Hz Power consumption 400 W Auxiliary connections Cooling air Integrated components Control and evaluation electronics Suction pump (rotary vane pump) Pressure sensors Condensate vessel (0.8 l, plastic) F 8016639/2013-09 Dust measuring devices SICK F-167
SHC500 Gravimat Gravimetric dust measurement devices GS5 filter head probe Description Dimensions (W x H x D) Weight Mounting Special head with integrated holder for dust collector, with pressure measuring points for isokinetic control of the suction process and with temperature sensor for accurate measurement of the gas temperature Details, see dimensional drawings Probe length 1 m: 7.3 kg Installation opening: diameter 80 mm HC dust collector Description Suction diameter Weight Material Collector for high dust concentrations (50... 50,000 mg/m³) 4.2 mm / 5.2 mm / 6.4 mm / 8 mm / 10 mm / 11.5 mm Funnel: 25 g Sample tube: 22 g Aluminum (funnel), brass/stainless steel (sample tube) LC dust collector Description Suction diameter Weight Material Collector for low dust concentrations (0.1... 200 mg/m³) 4.2 mm / 5.2 mm / 6.4 mm / 8 mm / 10 mm / 11.5 mm 16 g Stainless steel Ordering information Our regional sales organization will help you to select the optimum device configuration. Dimensional drawings GS5 filter head probe 64 70 Ø 50 Dimensions in mm Ø 62 30 13 500... 1.500 F F-168 Dust measuring devices SICK 8016639/2013-09
Gravimetric dust measurement devices SHC500 Gravimat F 8016639/2013-09 Dust measuring devices SICK F-169
8016639/2013-09 3M Pre USmod int40 SICK at a glance Leading technologies With a staff of more than 6,000 and over 40 subsidiaries and representations worldwide, SICK is one of the leading and most successful manufacturers of sensor technology. The power of innovation and solution competency have made SICK the global market leader. No matter what the project and industry may be, talking with an expert from SICK will provide you with an ideal basis for your plans there is no need to settle for anything less than the best. Unique product range Non-contact detecting, counting, classifying, positioning and measuring of any type of object or media Accident and operator protection with sensors, safety software and services Automatic identification with bar code and RFID readers Laser measurement technology for detecting the volume, position and contour of people and objects Complete system solutions for analysis and flow measurement of gases and liquids Comprehensive services SICK LifeTime Services for safety and productivity Application centers in Europe, Asia and North America for the development of system solutions under realworld conditions E-Business Partner Portal www.mysick.com price and availability of products, requests for quotation and online orders Worldwide presence with subsidiaries in the following countries: Australia Belgium/Luxembourg Brasil Ceská Republika Canada China Danmark Deutschland España France Great Britain India Israel Italia Japan México Nederland Norge Österreich Polska România Russia Schweiz Singapore Slovenija South Africa South Korea Suomi Sverige Taiwan Türkiye United Arab Emirates USA Please find detailed addresses and additional representatives and agencies in all major industrial nations at www.sick.com SICK AG Waldkirch Germany www.sick.com