On-load tap-changer OILTAP R

Similar documents
The On-Load Tap-Changer for Maximum Switching Frequency More Switching Operations without Needing Maintenance.

DS 600. A contact free flux gate based current measurement sensor 600A rms

Pluggable interface relays CR-P Pcb relays

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

OLI. Oil level indicator

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

3/2- and 2/2-way cartridge valve type BVE

Tool Turrets and Tool Discs

Lightning Arresters P KVA P KVA. Description & Installation

THE OLTC AS AN "OIL ISOLATED SYSTEM" IN THE TRANSFORMER & OIL ANALYSIS IN OLTC. I Hr. Dr. Hurm, Hr. Dr. Schübel I I

3/2-way Solenoid Valve, direct-acting, NC or NO

Power transformers. Special transformers Railway

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

5SV Residual Current Protective Devices

RY2 miniature industrial relays

Mounting Instructions. Torque Transducer. A en

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

PM734F - Technical Data Sheet Winding 28

40 Series - Miniature PCB/Plug-in relays A. Features

Transformer Bushings for GIS

Aluminum Electrolytic Capacitors Axial Miniature, Long-Life

Step Voltage Regulators

In addition to the basic models, it is also possible for the units to be outfitted with add-ons.

Electronic overload relay EF19 and EF45

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

produces and delivers products worldwide can provide the optimal are dedicated to supplying you with superior advice and global support.

Technical Information Requirement for MV transformers and transformer for internal power supplies for SUNNY CENTRAL

Technical data UNIBLOCK UBSF

High-ohmic/high-voltage resistors

Electronic overload relay EF65, EF96 and EF146

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

2. INDUCTIVE VOLTAGE TRANSFORMERS Oil-paper insulation Gas insulation

Type: DILM32 10(24V50HZ) Article No.:

LOW VOLTAGE RING TYPE MEASURING CURRENT TRANSFORMERS

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

MNS is Switchgear System Technical Overview

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

TECHNICAL SPECIFICATION FOR PROJECTION WELDING MACHINE (Qty. 2 Nos.)

Fig B36 Stainless Steel 'T' Type or Basket Type Strainers

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Medium voltage insulator

Aluminum Electrolytic Capacitors Power Eurodin Printed Wiring

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

COMBI. 7 SW COMBINED. SEWER. CLEANING. TRUCK ENGLISH INNOVATIONS FOR POWERFUL PERFORMANCES

UFES Active protection for switchgear

The complete range of consumer switchboards and switchgear

Type: DILM9 10(24VDC) Article No.:

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Directional seated valves type VP 1

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Basic Load Tap Changer Operation

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

MANTA Piston Distributor for Oil and Fluid Grease

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

R.C.C.B. s two-pole LEXIC

World Leader in HV Testing Technology

Series 8146/5-V37 and Series 8150/5-V37

Aluminum Electrolytic Capacitors Power Economic Printed Wiring

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

BOWIE PUMPS OPERATION - MAINTENANCE

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Type: DILM50(230V50HZ,240V60HZ) Article No.:

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH D MOOSBURG TEL FAX

Achat 115MA full-range speaker. user manual

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Cable Plug acc. to DIN EN , Form A

Plug-in relays Mini ISO relays

TYPE TEST CERTIFICATE OF SHORT-CIRCUIT PERFORMANCE. A three-phase outdoor oil-immersed distribution transformer

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Series Hose Reels

PLC-RS /21. PLC INTERFACE With PDT Relay, Universal Version. INTERFACE Data Sheet _en_02. 1 Description

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

handbook, 2 columns handbook, halfpage 085 CS

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Table of Contents. TransformerIQ FAQs 1

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Protection from Short-circuit

A E R Z E N E R M A S C H I N E N F A B R I K G M B H AERZEN POSITIVE DISPLACEMENT BLOWERS. for conveying of air and neutral gases for high vacuum

PV module safety qualification according to IEC 61730:2004 EN 61730:2007

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

V - JET. Counteflow System. V-JET Counterflow System Installation and Operation Manual

Transcription:

www.reinhausen.com Technical Data TD 115

2 TD 115/02

Table of Contents Table of Contents 1 General... 4 1.1 Summary of the technical data... 4 1.2 Survey... 6 2 Technical Data... 15 2.1 Rated through-current (I u ), rated step voltage (U i ) and step capacity (P StN )... 15 2.2 Contact life... 17 2.3 Rated withstand voltages of the internal insulation... 17 3 Appendix dimensional and installation drawings... 20 NOTE These technical data are intended for the calculator and designer of the transformer. These type-specific data are only valid in connection with the information contained in the general section (TD 61) since this section contains important information on such subjects as potential connection, leakage inductance, current division, and so on. Dimensional drawings and connection diagrams are subject to change without prior notice. Drawings submitted during bidding and ordering are always binding. Since the on-load tap-changer is delivered to the specifications of the transformer manufacturer, the transformer manufacturer is responsible for selecting the correct properties of the on-load tap-changer so that the requirements of the transformer are met. TD 115/02 3

1 General 1 General 1.1 Summary of the technical data On-load tap-changer R III 1200 Y R I 1201 R I 2002 R I 2402 3) R I 3003 Number of poles and application 3 (neutral point) 1 1 1 1 Max. rated through- 1200 1200 2000 2400 3000 current I um (in A) Rated short-time withstand 15 15 24 24 30 current (in ka) Rated short-circuit duration 3 3 3 3 3 (in s) Rated peak withstand current 37.5 37.5 60 60 75 (in ka) Max. rated step voltage U im 4000 4000 4000 4000 3000 (in V) 1) Step capacity (P StN ) 3000 3000 2) 4400 2) 6000 3) 6000 (in kva) Rated frequency (in Hz) 50 to 60 Operating positions Without change-over selector: max. of 18 With change-over selector: max. of 35 Rated insulation level Highest voltage for 72.5 123 170 245 9) 300 362 7) equipment U m (in kv) 5) Highest operating voltage U b 55 79 145 170 245 300 8) (phase-phase) on diverter switch (in kv) Rated lightning impulse with- 350 550 750 950 1050 1175 stand voltage (in kv, 1.2 I 50) Rated switching impulse 850 950 withstand voltage (in kv) AC withstand voltage 140 230 325 395 460 510 (in kv, 50 Hz, 1 min.) Rated withstand voltages of see table 3 internal insulation Oil compartment Pressure-proof up to 0.3 bar continuous difference pressure (test pressure 0.6 bar), head and cover of the on-load tap-changer are vacuum-proof. Oil suction pipe Installed as standard (for details, see BA 18) Temperature range The on-load tap-changer OILTAP R can be operated in the rated load range with oil temperatures of -25 C to +105 C. Table 1 a 4 TD 115/02

1 General On-load tap-changer R III 1200 Y R I 1201 R I 2002 R I 2402 R I 3003 Weight (in kg) ca. without change- 525 360 445 4) 445 525 over selector with change- 595 (770 4) ) 410 (500 4) ) 505 (640 4) ) 505 (640 4) ) 595 (780 4) ) over selector Displacement volume (in dm 3 ) ca. 72.5 kv 289 (367 4) ) 274 (353 4) ) 280 (360 4) ) 280 (360 4) ) 286 (367 4) ) 123 kv 314 (392 4) ) 299 (376 4) ) 305 (384 4) ) 305 (384 4) ) 311 (392 4) ) 170 kv 334 (412 4) ) 319 (396 4) ) 325 (404 4) ) 325 (404 4) ) 331 (412 4) ) 245 kv 354 (432 4) ) 339 (416 4) ) 345 (424 4) ) 345 (424 4) ) 351 (432 4) ) 300 kv 369 (446 4) ) 374 (453 4) ) 374 (453 4) ) 380 (461 4) ) Oil filling quantity V S and minimum volume DV 6) of the diverter switch oil compartment 72.5 kv 168 123 kv 188 170 kv 203 245 kv 218 300 kv 240 Table 1 b Notes for tables 1a and 1b: 1) The maximum rated step voltage may be exceeded by 10% due to overexcitation of the transformer if the step capacity is limited to its rated value. 2) Higher step capacities available as special design 3) Forced current division by two parallel winding branches required 4) Applies to tap selector size E 5) In accordance with VDE 0111, part 1: R.m.s. value of the phase-phase voltage for which a piece of equipment is rated for its insulation 6) Minimum volume of oil conservator for oil temperature ϑ = 30 C... +100 C: DV = 0,1 V S + 4 (dm 3 ) 7) On request 8) Oil filter unit 0F 100 (combi-filter) required, U bst > 300 kv on request 9) Rated withstand voltages comply with IEC 60214: 1989; unrestricted tests possible up to 1050 kv 1.2 50 or 460 kv, 50 Hz, 1 min. TD 115/02 5

1 General 1.2 Survey 8997470E_01 Fig. 1a Survey of the on-load tap-changer designs (no. of poles, change-over selector, and installation lengths) 6 TD 115/02

1 General 8997470E_02 Fig. 1b Survey of the on-load tap-changer designs (no. of poles, change-over selector, and installation lengths) TD 115/02 7

1 General Survey of the basic connection diagrams (figures 2a, 2b, 2c) with designation of the tap selector contact terminals in accordance with MR standards. This contact terminal designation corresponds to the specifications in the on-load tap-changer dimensional drawings. Fig. 2a excerpt from 8906164E_1 8 TD 115/02

1 General Fig. 2b 8906164D_2 TD 115/02 9

1 General Fig. 2c 8906164D_3 10 TD 115/02

1 General Examples of connection diagrams (contact designation in acc. w. MR standards) Fig. 3 Example: On-load tap-changer R III 1200 Y C/D, basic connection diagram 10 19 1 W TD 115/02 11

1 General Fig. 4 Example: On-load tap-changer R III 1200 Y E, basic connection diagram 14 27 1 G 12 TD 115/02

1 General Fig. 5 Example: On-load tap-changer R I 2002 C/D, basic connection diagram 18 35 1 W TD 115/02 13

1 General Fig. 6 Example: On-load tap-changer R I 3003 C/D, basic connection diagram 18 35 1 W 14 TD 115/02

2 Technical Data 2 Technical Data 2.1 Rated through-current (I u ), rated step voltage (U i ) and step capacity (P StN ) On-loadtap-changer R I 2003 R III 1200 Y R I 1201 R I 2002 (Special design) R I 2402 1) R I 3003 I u (A) 700 1200 700 1200 1070 2000 1300 2000 1400 2400 2000 3000 U i (V) 4000 2500 4000 2500 4000 2200 4000 3000 4000 2500 3000 2000 P StN (kva) 2800 3000 2800 3000 4280 4400 5200 6000 5600 6000 6000 6000 Table 2 Rated through-currents (I u ), related rated step voltages (U i ) and step capacities (P StN ), at highest and lowest rated step voltage of the step capacity curve (see fig. 7 and fig. 8) 1) Note: R I 2402 with forced current division by two parallel winding branches Fig. 7 Step capacities (rated step voltages U i, rated throughcurrents I u ) for on-load tap-changer R III 1200 Y, R I 1201, R I 1202 8997510E CAUTION: Only applies to network service. When used for industrial transformers, please contact us. TD 115/02 15

2 Technical Data 8997510E Fig. 8 Step capacities (rated step voltages U i, rated through-currents I u ) for on-load tap-changer R I 2002, R I 2003 (= special design), R I 2402, R I 3003. Note: 1) R I 2402 with forced current division by two parallel winding branches. CAUTION: Only applies to network service. When used for industrial transformers, please contact us. 16 TD 115/02

2 Technical Data 2.2 Contact life The mean expected contact life of the arcing diverter switch contacts can be estimated based on the relative load (I u / I um ) as shown in figure 9. Since actual contact life in individual cases depends on many influencing factors while in service, only estimations can be given (not applicable to constant current service). The inspection regulations must be observed. Fig. 9 Expected mean contact life under average load n Number of operations I u Rated through-current I um Max. rated through-current KHW 579-4 TD 115/02 17

2 Technical Data 2.3 Rated withstand voltages of the internal insulation Fig. 10 shows diagrams of the voltage stress present on the tap winding of the three primary basic connections of threepole on-load tap-changers and single-pole on-load tap-changers. When selecting the on-load tap-changer, a check must be made to determine whether the highest stress on the tap selector does not exceed the related rated withstand voltages. Without change-over selector With reversing switch With coarse tap selector in (+) - position With coarse tap selector in (-) - position 8997560M CAUTION Adhere to the maximum rated lightning impulse withstand voltage stress on a0 in mid-position. a0 = Between preselected and selected tapping on the diverter switch a1 = Between tap selector contacts of the winding of one tap position (connected or not) a = Between beginning and end of a tapped winding and, with coarse tap winding, between beginning and end of a coarse tap winding. Note for coarse tapping arrangement in (-) -position of the change-over selector: When stressed with impulse voltage, the permissible withstand voltage a must be adhered to between the end of a coarse tap winding connected with the K tap selector contact and the tap selector contact at the end of the tapped winding of the same phase. b = Between the tap selector contacts of different phases and between change-over selector contacts of different phases, which are connected with the beginning/end of a tapped winding or with a tap selector contact. f = Between diverter switch terminal and ground Additional for coarse tapping arrangement in (+) - position of the change-over selector: c1 = From one (-) -change-over selector contact to terminal of the same phase. c2 = Between (-) -change-over selector contacts of different phases Fig. 10 Rated withstand voltages 18 TD 115/02

2 Technical Data Insulation Tap selector size C Tap selector size D 1) Tap selector size E distances kv 1.2I50 kv, 50 Hz, 1 min kv 1.2I50 kv, 50 Hz, 1 min kv 1.2I50 kv, 50 Hz, 1 min a0 U b 72.5 kv: 140 kv 1.2I50; 30 kv, 50 Hz, 1 min / U b >72.5 kv: 80 kv 1.2I50; 3 x U St a1 150 30 150 30 150 30 a 400 85 500 2) 110 670 180 b 3) 400 100 500 2) 150 670 180 c 1 550 180 590 210 820 250 3) c 2 550 195 590 225 820 280 Table 3 Note: Rated withstand voltages (in kv) of the internal insulation of the tap selector 1) Tap selectors in accordance with basic connection diagrams 10 09 1 W, 12 11 1 W, 14 13 1 W are designed as 18 09 1 W, 18 11 1 W, 18 13 1 W. Tap selectors in accordance with basic connection diagrams 16 15 1 W and 18 17 1 W are not possible. 2) Higher values up to 550 kv on request 3) Omitted for on-load tap-changers R I 1201, R I 2002/2402, R I 3003 The tap selector size (ID letters C, D, E) characterizes the internal insulation of the tap selector whose rated withstand voltages must be adjusted to the requirements of the transformer winding. The permissible maximum service voltage along the individual tap selector paths is half the AC withstand voltages listed in table 3. TD 115/02 19

3 Appendix 3 Appendix Dimensional drawings III 1200 Y, tap selector size C/D, E... 896722, 897867 I 1201, tap selector size C/D, E... 899753, 899401 I 2002, tap selector size C/D, E... 896721, 897866 I 2402, tap selector size C/D, E... 897490, 897864 I 3003, tap selector size C/D, E... 896720, 897865 Tap selector and change-over selector terminal contacts, tap selector size E... 897868 Installation drawings Tap selector size C/D... 896705 Tap selector size E... 897873 Additional drawings On-load tap-changer head... 893899 On-load tap-changer cover with mounting flange for pressure relief valve... 895168 Versions of the on-load tap-changer head, swiveling range of gear unit... 896703 Special design for installation in bell-type tanks... 896762 Horizontal drive shaft, tap selector size C/D, E... 896708, 897872 Jumpers for parallel connection of tap selector terminal contacts for on-load tap-changer OILTAP R I 2002, R I 3003, selector size C/D, E... 896706, 898713 Tap selector bottom, shielding, tap selector size C/D... 896702 Tap selector bottom, tap selector size E... 897869 Tie-in resistors, tap selector size C/D... 896707, 898124-898135 Potential switch, tap selector size C/D, E... 898136, 898614 Additional drawings for on-load tap-changer... 898826 20 TD 115/02

8967227E R III 1200 - C/D, dimension drawing TD 115/02 21

8978677E R III 1200 - E, dimension drawing 22 TD 115/02

8997530E R I 1201 - C/D, dimension drawing TD 115/02 23

8994011E R I 1201 - E, dimension drawing 24 TD 115/02

8967218E R I 2002 - C/D, dimension drawing TD 115/02 25

8978666E R I 2002 - E, dimension drawing 26 TD 115/02

8974905E R I 2402 - C/D, with forced current division with two parallel winding branches, dimension drawing TD 115/02 27

8978646E R I 2402 - E, with forced current division with two parallel winding branches, dimension drawing 28 TD 115/02

8967208E R I 3003 - C/D, dimension drawing TD 115/02 29

8978657E R I 3003 - E, dimension drawing 30 TD 115/02

8978683E Tap selector size E, tap selector and change-over selector terminal contacts TD 115/02 31

8967056E Tap selector size C/D, installation drawing 32 TD 115/02

8978733E Tap selector size E, installation drawing TD 115/02 33

893899AE On-load tap-changer OILTAP MS, M, R, RM On-load tap-changer head, centric drive 34 TD 115/02

8951685E On-load tap-changer OILTAP MS, M, R, RM With flange for pressure relief valve TD 115/02 35

8967034E Versions of the on-load tap-changer head, swiveling range and drive direction of the gear unit 36 TD 115/02

8967627E On-load tap-changer OILTAP MS, M, R, RM Special design for installation in bell-type tank O-Ring 44.2-5,7 Lifting device Suction pipe Drilling hole in sectional plane Transformer cover O-Ring Level traverse Guiding ring with U m = 170 kv, 245 kv, 300 kv Supporting flange Level traverse Z = Guiding pin Drive side of the tap selector TD 115/02 37

8967087E On-load tap-changer OILTAP MS, M, R, RM Horizontal drive shaft (limit dimensions) Tap selector size C/D, centric drive 38 TD 115/02

8978723E Horizontal drive shaft (limit dimensions) Tap selector size E, centric drive TD 115/02 39

8967066E R I 2002, R I 3003, tap selector size C/D Jumpers for parallel connection of tap selector terminal contacts 40 TD 115/02

8987131E R I 2002, R I 3003, tap selector size E Jumpers for parallel connection of tap selector terminal contacts TD 115/02 41

8967028E On-load tap-changeroiltap R Tap selector size C/D, tap selector bottom shown with the lowest parts connected to the voltage, standard design without grading ring, special design with grading ring 42 TD 115/02

8978695E Tap selector size E, tap selector bottom shows lowest parts connected to voltage TD 115/02 43

8967078E Tap selector size C/D, principal arrangement of potential switch and tie-in resistors 44 TD 115/02

8981242M Tie-in resistor cylinder R I to WP, tap selector size C/D, U m = 72.5 kv to 300 kv, 2 x 14 to 2 x 18 resistors TD 115/02 45

8981252M Tie-in resistor cylinder R I to WP, tap selector size C/D, U m = 72.5 kv to 300 kv, 2 x 3, 2 x 5, to 2 x 13 resistors 46 TD 115/02

8981262M Tie-in resistor cylinder R I to WP, tap selector size C/D, U m = 72.5 kv to 300 kv, 2 x 4, 2 x 6 to 2 x 12 resistors TD 115/02 47

8981272M Tie-in resistor cylinder R I to WP, tap selector size C/D, U m = 72.5 kv to 300 kv, 3 to 26 resistors 48 TD 115/02

8981282M Tie-in resistor cylinder R I to WR, tap selector size C/D, U m = 72.5 kv to 300 kv, 2 x 14 to 2 x 18 resistors TD 115/02 49

8981292M Tie-in resistor cylinder R I to WR, tap selector size C/D, U m = 72.5 kv to 300 kv, 2 x 3, 2 x 5, to 2 x 13 resistors 50 TD 115/02

8981302M Tie-in resistor cylinder R I to WR, tap selector size C/D, U m = 72.5 kv to 300 kv, 2 x 4, 2 x 6, to 2 x 12 resistors TD 115/02 51

8981312M Tie-in resistor cylinder R I to WR, tap selector size C/D, U m = 72.5 kv to 300 kv, 3 to 26 resistors 52 TD 115/02

8981322M Tie-in resistor cylinder R III 1200 WP, tap selector size C/D, U m = 72.5 kv to 245 kv, 3 x 2 to 3 x 7 resistors TD 115/02 53

8981332M Tie-in resistor cylinder R III 1200 WP, tap selector size C/D, U m = 72.5 kv to 245 kv, 3 x 8 to 3 x 10 resistors 54 TD 115/02

8981342M Tie-in resistor cylinder R III 1200 WR, tap selector size C/D, U m = 72.5 kv to 245 kv, 3 x 2 to 3 x 8 resistors TD 115/02 55

8981352M Tie-in resistor cylinder R III 1200 WR, tap selector size C/D, U m = 72.5 kv to 245 kv, 3 x 9 to 3 x 11 resistors 56 TD 115/02

8981362M Potential switch R III 1200 WS, R I to WS, tap selector size C/D, U m = 72.5 kv to 300 kv TD 115/02 57

8986142M Potential switch R III 1200 WS, R I to WS, tap selector size E, U m = 72.5 kv to 300 kv 58 TD 115/02

8988261E Additional drawings for on-load tap-changer Basic connection diagrams...890616 Tap selector and change-over selector terminal contacts, tap selector size E...897868 Tap selector bottom, shielding, tap selector size C/D... 896702 Tap selector bottom, tap selector size E...897869 Versions of the on-load tap-changer head... 896703 Horizontal drive shaft, tap selector size C/D... 896708 Horizontal drive shaft, tap selector size E...897872 Installation drawing, tap selector size C/D... 896705 Installation drawing, tap selector size E...897873 On-load tap-changer head...893899 TD 115/02 59

www.reinhausen.com Maschinenfabrik Reinhausen GmbH Phone +49 941 40 90-0 Falkensteinstrasse 8 Fax +49 941 40 90-111 93059 Regensburg, Germany E-Mail sales@reinhausen.com Please note: The data in our publications may differ from the data of the devices delivered. We reserve the right to make changes without notice. TD 115/02 en 0903/1000 F0019601 Printed in Germany