Seawater Reverse Osmosis System Price List

Similar documents
Water Treatment and Reverse Osmosis Systems

AQUAPRO INDUSTRIAL CO.,LTD. Reverse Osmosis Parts Introduction

DOW Ultrafiltration. Case History. High Turbidity and Temperature Fluctuation No Obstacle for DOW Ultrafiltration

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

Medical Air Systems: Scroll

4 Stage Barracuda RO/DI Instruction & Owner s Manual

Basics of Reverse Osmosis

Cooling Tower Sidestream Filtration A Green, Proven Cost Reduction Technology

Drinking water for Gaza Elaboration concept 2

FILMTEC Membranes Strategies for Using FILMTEC Elements to Lower Your Total Cost of Seawater Desalination

1. Conductivity < 15 micro ohms/cm 2. ph of 6.0 to Nonvolatile TOC content < 1.0 ppm

Stenner Pump Chlorinator Installation & Start Up Guide

Description & Working

Electrodeionization (EDI)

By: Curt Roth Vice President, Engineering EconoPure Water Systems, LLC. Point of Use/Point of Entry Treatment with LFNano. An EconoPure White Paper

ECOAZUR BLUEWATER WATER PURIFICATION PLANTS

RO Reverse Osmosis equipments

SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

for Sediment Removal desired levels. The filtered water then can be chemically treated to ensure its safety. Municipal water Preliminary settling

Tampa Bay Seawater Desalination Plant

PRICE LIST Brutto incl.moms Januar 2011

Differentiation Summary. Revolutionizing Water Clean-Up Opportunities

Troubleshooting Your RO

Energy Recovery Device isave 21-40

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Comparison of multiple port and end port connections for pressure vessels

SIMPLE... AFFORDABLE... ENERGY EFFICIENT... LOW MAINTENANCE...

Removing Solids with Automatic Self-Cleaning Filters

Iron Air Charge 2510-SXT Installation & Start-Up Guide

INTERSTAGE ENERGY RECOVERY TURBINE APPLICATION MARCO ISLAND, FLORIDA

Watts Pure Water Systems

7 Years Operation of BWRO Plant with Raw Water from Coastal Aquifer for Agriculture Irrigation

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

AXIAL PISTON-PRESSURE EXCHANGER DEVELOPMENT PROGRAM. 1.0 Abstract

A meaningful, cost-effective solution for polishing reverse osmosis permeate

Hollow Fiber Cleaning and Storage Procedure

Advanced_O&M_Task_List_Example_Tool_06_02_16: O&M Example

A Guide to Trouble-Free Cooling Towers

Commercial Electric Water Heater

Kompressoren. Adsorption Dryer AD

Desalination Systems for Yachts, Boats and Motor Homes

Cooking at the Speed of light!

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

7. TECHNICAL ASPECTS OF DESALINATION PLANT

HEINRICH FRINGS INFORMATION

Total water management. Water and wastewater treatment systems for ships and offshore

Nine Industrial Scale V SEPs. Feed Tank V SEP. Feed Pumps (Three) Concentrate. Tank. V SEP Treatment System

Atlas Copco Quality Air Solutions. Compressed Air Filters

Amiad s AMF² pre-treatment technology ensures efficient and reliable nanofiltration of Scottish Highland loch water

SECTION 11 drinking Water Systems

Solar Hot Water Heaters

Membrane Filtration Technology: Meeting Today s Water Treatment Challenges

THE EFFICIENT REMOVAL OF ORGANIC AND INORGANIC SUSPENDED SOLIDS OLD PROBLEM, NEW TECHNOLOGY

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

DIESEL FUEL CONDITIONING

Reverse Osmosis (RO) Drinking Water System. Product Manual

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Information Technology Solutions

Trouble Shooting. Pump

Innovation and Progress in Water Treatment Technology

James City Service Authority Five Forks Water Treatment Facility

Cartridge Filter Application Notes

Interface Level And Point Level Analyzers & Sensors

David O. Ahrens, Commercial Marine Manager Caterpillar Engine Products Division

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service:

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE

1. Inspection and monitoring... 3

How To Clean Up A Reactor Water Cleanup

Water Equipment Technologies. Advanced Membrane Technologies for Solving Worldwide Water Problems

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

MEMCOR membranes for drinking water applications. Water Technologies

Portable Swimming Pool Reverse Osmosis Systems

Light Duty Commercial Electric Water Heater

Remediation of Water-Based Drilling Fluids and Cleaning of Cuttings

FILLING AND PURGING THE SYSTEM

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

2A.1 Features of Chiller Control Components A.3 Chilled-Water Supply Temperature Control A.4 Cooling-Water Supply Control...

300 Series PA Pump and Cooler Assemblies

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

FAMILY PROTECTION FROM WATERBORNE DISEASES

MODEL INSTALLATION INSTRUCTIONS

understanding medium frequency induction melting furnace and its components

PACKAGE TERTIARY FILTER SYSTEM SPECIFICATIONS MODELS TF-2-6-C THROUGH TF-2-35-C

Control of legionella bacteria in water systems

MC4-50 Feeding System

ASME Packaged Indirect Fired Water Heater

Fiberstars Mini Lighted Laminar Flow Fountains

Experts Review of Aerobic Treatment Unit Operation and Maintenance. Bruce Lesikar Texas AgriLife Extension Service

Treatment options for hydrogen sulfide. Testing for hydrogen sulfide

RO / NF Cleaning Guidelines

Optimizing Tank Cleaning Operations

Simply complete the enclosed Warranty Form with contact details, or us with your details and date of purchase.

Pro-OX 7800 Iron Filter Installation & Start-Up Guide

Cat Electronic Technician 2015A v1.0 Product Status Report 6/3/2015 4:41 PM

SWIMMING POOL HEAT PUMP Owners Manual

Wastewater Reuse. Typical treated wastewater is:

Operational Overview and Controls Guide

MARBELLA SEAWATER DESALINATION PLANT: CONSTRUCTION AND START - UP EXPERIENCE. Juan María Sánchez, Juan Velasco, Jose M. Kindelan and Jaime Andreu

Transcription:

Seawater Reverse Osmosis System Price List Model Number Production (GPD) Production (M 3 /Day) Regular System Price Containerized System Price Custom Design for Ocean Vessels Note 600 600 2.3 $11,000 SRWO-800 800 3.0 $19,000 1000 1,000 3.8 $25,000 1500 1,500 5.7 $35,000 ized design not available $11,550 ized design not available $19,950 ized design not available $26,250 ized design not available $36,750 3000 3,000 11.4 $39,000 $48,000 $40,950 4500 4,500 17.0 $43,000 $52,000 $45,150 6000 6,000 22.7 $50,000 $59,000 $52,500 5GPM 7,200 27.3 $53,000 $62,000 $55,650 7GPM 10,080 38.2 $66,000 $75,000 $69,300 10GPM-cnt 14,400 54.5 $69,000 $78,000 $72,450 15GPM-cnt 21,600 81.8 $129,000 $138,000 $135,450 20GPM-cnt 28,800 109.0 $143,000 $152,000 $150,150 30GPM-cnt 43,200 163.5 $165,000 $180,000 $173,250 35GPM-cnt 50,400 190.8 $180,000 $195,000 $189,000 40GPM-cnt 57,600 218.0 $205,000 $220,000 $215,250 50GPM-cnt 72,000 272.5 $231,000 $246,000 $242,550 60GPM-cnt 86,400 327.0 $250,000 $265,000 $262,500 70GPM-cnt 100,800 381.5 $275,000 $290,000 $288,750 85GPM-cnt 122,400 463.3 $375,000 $390,000 $393,750

92GPM-cnt 132,000 499.6 $435,000 $450,000 $456,750 100GPMcnt 144,400 546.6 $465,000 $480,000 $488,250 183GPMcnt 264,100 1,000 $735,000 $750,000 $771,750 2x40' s

GENERAL TECHNICAL SPECIFICATIONS FOR 20GPM to 183GPM Feed water: less than 42,000 ppm Required feed water pressure: 40 psi Production rate is rated at: 25 C/ 77 F (higher temperature will yield higher production rate, and vice versa) Product water quality: less than 500 ppm Recovery Rate: 35-40% Working Pressure: 700-900 psi (depending on feed water TDS and temperature) Power consumption 3.5-4.5 kwh/m3 (depending on feed water TDS and temperature) 1. RO System ForeverPure Seawater RO systems are designed to operate under high or low TDS conditions. The built-in Variable Frequency Drive (VFD) can be adjusted to increase or lower the operation pressure according to feed water TDS and temperature. The VFD feature coupled with Energy Recovery System greatly improves the system efficiency and lowers electrical consumption. In today s high energy cost world, these are essential features to have in a seawater desalination plant. To minimize anti-scalant consumption, the RO system utilizes low recovery ratio design. This simplifies chemical storage logistics and reduces the cost of chemicals. This design also utilized low flux rate design to ensure long membrane service life. Pre-Filtration System: Stainless Steel/fiberglass/PVC housing, 5-micron cartridge type sediment filter further reduces suspended solids in the feed water stream to RO system. It protects the RO high-pressure pump and lead end RO membrane elements from debris. Membrane Housing: fiberglass, 8" housing, 1000 psi rated pressure vessels. Membranes: New energy saving, Dow Filmtec low pressure membranes. High pressure RO Pump: 900 psi, corrosion resistant 2205 duplex stainless steel. Energy Recovery Device: High Pressure Booster energy recovery system included. 2205 duplex SS and 316L SS

Motor: high efficiency, 3 Phase, TEFC. Available for power ratings worldwide. High pressure side piping material: 316 Stainless Steel Low pressure side piping material: Schedule 80 PVC Concentrate control valve: 316 Stainless Steel Water quality monitor: feed water and product water TDS meter Flow meters: Panel Mount Flow Meters for feed water and product water. Pressure Gauges: Feed Water Pressure, working pressure, Concentrate System controls (automatic operation and manual): Full Color Touch Screen Operator Interface is standard on all models 20GPM or larger. Touch screen provide online trouble shooting instructions, operation and maintenance instructions, real time monitoring of all motors, sensors, valves, and pumps. Allen Bradley Programmable Logic Controller (PLC) to provide start/stop, sequential, and alarm control. RO System start permissible conditions: 1. Power On 2. Start button pushed 3. Low pressure switch closed 4. Permeate water tank level below low level (low and high level switches are on open position) Five conditions will cause the RO to shut down the machine: 1. High working pressure, 2. Low inlet pressure (<20 psi) 3. Starter overload trip 4. Product water storage tank level high 5. Emergency shut-down button pushed. Low Feed Pressure Shut Off with indicator light High pressure shut-off switch Product Water and raw water Tank level control System On switch with light Power On switch with light

Pre-Treatment Systems 2. Anti-scalant Dosing System One metering injection systems will be supplied for controlling different elements in the feed water of the RO plant. The metering pump will allow controlling of different functions such as the stroke length and percentage rate. The Antiscalant Dosing System prevents the membrane from scaling. 3. Biocide Dosing System One metering injection systems will be supplied for controlling different elements in the feed water of the RO plant. The metering pump will allow controlling of different functions such as the stroke length and percentage rate. The Biocide Dosing System prevents biofouling of multi-media and RO membranes. 4. Multi-Media Filter A multimedia filter is designed to make better use if the bed depth in the removal of a greater volume of suspended solids. This is achieved by loading larger media granules of lower density at the top of the bed, with at least one layer of smaller media granules of higher density below it. The larger granules remove the larger suspended particles, leaving the smaller particles to be filtered by the finer media. Three depth multi-media filtration system is used to filter sand and sediment (turbidity) down to approximately 20 Microns. Automatically backwashes when clogged. Saves replacement filter cost. All units are made using high performance, corrosion resistant composite & fiberglass tank. Membrane Cleaning and Flushing Systems 5. Permeate Water Flush The Permeate Water Flush function purges the salt water out of the system by pumping permeate water into the membrane housing before each shut down. This maintains product water quality and extend the membrane life time. 6. Built-in Membrane Cleaning System Includes high flow pump. It cleans membranes and can be used to sanitize the membrane system. Automatic cleaning/flushing. This system dramatically increases the life of the membranes. Miscellaneous 7. High Product Water TDS Diversion With Alarm If the product water TDS rises above a preset value, then the system will trigger an alarm and divert the unqualified product water into the drain. This function ensures product water quality.

8. Container (for ized models) Logo on both sides of the Complete insulation of the Pre-plumbed Pre-wired Pre-test before shipping Air conditioning system Floor-3/4 plywood on 16 centers Door -High security double swing out doors with Paint white rust inhibitive paint inside and outside. Interior Lights Main power panel

GENERAL TECHNICAL SPECIFICATIONS FOR 3000 to 15GPM Feed water: less than 42,000 ppm Required feed water pressure: 40 psi Production rate is rated at: 25 C/ 77 F (higher temperature will yield higher production rate, and vice versa) Product water quality: less than 500 ppm Recovery Rate: 35-40% Working Pressure: 700-900 psi (depending on feed water TDS and temperature) Power consumption 6-8 kwh/m3 (depending on feed water TDS and temperature) 1. RO System ForeverPure Seawater RO systems are designed to operate under high or low TDS conditions. The built-in Variable Frequency Drive (VFD) can be adjusted to increase or lower the operation pressure according to feed water TDS and temperature. To minimize anti-scalant consumption, the RO system utilizes low recovery ratio design. This simplifies chemical storage logistics and reduces the cost of chemicals. This design also utilized low flux rate design to ensure long membrane service life. Pre-Filtration System: Stainless Steel/fiberglass/PVC housing, 5-micron cartridge type sediment filter further reduces suspended solids in the feed water stream to RO system. It protects the RO high-pressure pump and lead end RO membrane elements from debris. Membrane Housing: fiberglass, 1000 psi rated pressure vessels. Membranes: New energy saving, Dow Filmtec low pressure membranes. High pressure RO Pump: 900 psi, CAT plunger pump, 316 stainless steel. Motor: high efficiency, 3 Phase, TEFC. Available for power ratings worldwide. High pressure side piping material: 316 Stainless Steel Low pressure side piping material: Schedule 80 PVC Concentrate control valve: 316 Stainless Steel Water quality monitor: feed water and product water TDS meter Flow meters: Panel Mount Flow Meters for feed water and product water.

Pressure Gauges: Feed Water Pressure, working pressure, Concentrate System controls (automatic operation and manual): Touch Screen Operator Interface is standard on all models 20GPM or larger. Touch screen provide online trouble shooting instructions, operation and maintenance instructions, real time monitoring of all motors, sensors, valves, and pumps. Idec/Allen Bradley Programmable Logic Controller (PLC) to provide start/stop, sequential, and alarm control. RO System start permissible conditions: 1. Power On 2. Start button pushed 3. Low pressure switch closed 4. Permeate water tank level below low level (low and high level switches are on open position) Five conditions will cause the RO to shut down the machine: 1. High working pressure, 2. Low inlet pressure (<20 psi) 3. Starter overload trip 4. Product water storage tank level high 5. Emergency shut-down button pushed. Low Feed Pressure Shut Off with indicator light High pressure shut-off switch Product Water and raw water Tank level control System On switch with light Power On switch with light Pre-Treatment Systems 2. Anti-scalant Dosing System One metering injection systems will be supplied for controlling different elements in the feed water of the RO plant. The metering pump will allow controlling of different functions such as the stroke length and percentage rate. The Antiscalant Dosing System prevents the membrane from scaling. 3. Biocide Dosing System One metering injection systems will be supplied for controlling different elements in the feed water of the RO plant. The metering pump will allow controlling of different functions such as the stroke length and percentage rate. The Biocide Dosing System prevents biofouling of multi-media and RO membranes.

4. Multi-Media Filter A multimedia filter is designed to make better use if the bed depth in the removal of a greater volume of suspended solids. This is achieved by loading larger media granules of lower density at the top of the bed, with at least one layer of smaller media granules of higher density below it. The larger granules remove the larger suspended particles, leaving the smaller particles to be filtered by the finer media. Three depth multi-media filtration system is used to filter sand and sediment (turbidity) down to approximately 20 Microns. Automatically backwashes when clogged. Saves replacement filter cost. All units are made using high performance, corrosion resistant composite & fiberglass tank. Membrane Cleaning and Flushing Systems 5. Permeate Water Flush The Permeate Water Flush function purges the salt water out of the system by pumping permeate water into the membrane housing before each shut down. This maintains product water quality and extend the membrane life time. 6. Built-in Membrane Cleaning System Includes high flow pump. It cleans membranes and can be used to sanitize the membrane system. Automatic cleaning/flushing. This system dramatically increases the life of the membranes. Miscellaneous 7. High Product Water TDS Diversion With Alarm If the product water TDS rises above a preset value, then the system will trigger an alarm and divert the unqualified product water into the drain. This function ensures product water quality. 8. Container (for ized models) Logo on both sides of the Complete insulation of the Pre-plumbed Pre-wired Pre-test before shipping Air conditioning system Floor-3/4 plywood on 16 centers Door -High security double swing out doors with Paint white rust inhibitive paint inside and outside. Interior Lights Main power panel

GENERAL TECHNICAL SPECIFICATIONS FOR 600 to 1500 Feed water: less than 42,000 ppm Required feed water pressure: 40 psi Production rate is rated at: 25 C/ 77 F (higher temperature will yield higher production rate, and vice versa) Product water quality: less than 500 ppm Recovery Rate: 35-40% Working Pressure: 700-900 psi (depending on feed water TDS and temperature) Power consumption 8-9 kwh/m3 (depending on feed water TDS and temperature) 1. RO System ForeverPure Seawater RO systems are designed to operate under high or low TDS conditions. The built-in Variable Frequency Drive (VFD) can be adjusted to increase or lower the operation pressure according to feed water TDS and temperature. Pre-Filtration System: Stainless Steel/fiberglass/PVC housing, 5-micron cartridge type sediment filter further reduces suspended solids in the feed water stream to RO system. It protects the RO high-pressure pump and lead end RO membrane elements from debris. Membrane Housing: fiberglass, 1000 psi rated pressure vessels. Membranes: New energy saving, Dow Filmtec low pressure membranes. High pressure RO Pump: 900 psi, CAT plunger pump, 316 stainless steel. Motor: high efficiency, 3 Phase, TEFC. Available for power ratings worldwide. High pressure side piping material: 316 Stainless Steel Low pressure side piping material: Schedule 80 PVC Concentrate control valve: 316 Stainless Steel Water quality monitor: hand held TDS meter Flow meters: Panel Mount Flow Meters for feed water and product water. Pressure Gauges: Feed Water Pressure, working pressure, Concentrate System controls (automatic operation and manual): Idec/Allen Bradley Programmable Logic Controller (PLC) to provide start/stop, sequential, and alarm control.

RO System start permissible conditions: 1. Power On 2. Start button pushed 3. Low pressure switch closed 4. Permeate water tank level below low level (low and high level switches are on open position) Five conditions will cause the RO to shut down the machine: 1. High working pressure, 2. Low inlet pressure (<20 psi) 3. Starter overload trip 4. Product water storage tank level high 5. Emergency shut-down button pushed. Low Feed Pressure Shut Off with indicator light High pressure shut-off switch Product Water and raw water Tank level control System On switch with light Power On switch with light Pre-Treatment Systems 2. Anti-scalant Dosing System One metering injection systems will be supplied for controlling different elements in the feed water of the RO plant. The metering pump will allow controlling of different functions such as the stroke length and percentage rate. The Antiscalant Dosing System prevents the membrane from scaling. 3. Biocide Dosing System One metering injection systems will be supplied for controlling different elements in the feed water of the RO plant. The metering pump will allow controlling of different functions such as the stroke length and percentage rate. The Biocide Dosing System prevents biofouling of multi-media and RO membranes. Membrane Cleaning and Flushing Systems 4. Permeate Water Flush The Permeate Water Flush function purges the salt water out of the system by pumping permeate water into the membrane housing before each shut down. This maintains product water quality and extend the membrane life time.

5. Built-in Membrane Cleaning System Includes high flow pump. It cleans membranes and can be used to sanitize the membrane system. Automatic cleaning/flushing. This system dramatically increases the life of the membranes. Miscellaneous 6. High Product Water TDS Diversion With Alarm If the product water TDS rises above a preset value, then the system will trigger an alarm and divert the unqualified product water into the drain. This function ensures product water quality.