Measuring ph in Acidified Foods

Similar documents
Care and use guide. Contents. a handy solution made easy. page

ph Measurement and Control

USEPA Electrode Method Method 8156

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

Milwaukee USER MANUAL

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

AIRMoN, ph and Conductivity Field Measurement

Measuring ph in Water or CaCl2 Using a ph Meter. Compiled by Darren Murray, June 30, 2011 TABLE OF CONTENTS OVERVIEW 3

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

UltraBasic Benchtop ph Meter Operation Manual

SenTix 950 SenTix 980

ph and Acidity in Wine and Fruit Juice

Handbook. Thermo Scientific. ph Electrode Selection Handbook

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

Bluelab Soil ph Meter Instruction Manual

CHM 130LL: ph, Buffers, and Indicators

A Potentiometric Analysis of Fluoride Ion in Toothpaste

ph and Acidity in Tomato Sauce

18 Conductometric Titration

Compact ph Measuring Instruments

Electrical Conductivity of Aqueous Solutions

Experiment 4 (Future - Lab needs an unknown)

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

EXPERIMENT 20: Determination of ph of Common Substances

ph Measurements of Common Substances

Care and use guide. Contents. page

Household Acids and Bases

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

ELECTROCHEMISTRY. Theory and Practice

Related concepts Kohlrausch s law, equivalent conductivity, temperature dependence of conductivity, Ostwald s dilution law.

Lab 7 Soil ph and Salinity OBJECTIVE INTRODUCTION Soil ph active

PART 1 - INTRODUCTION...

Drop Counter Sensor Product Number: ENDRP-AD100

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Properties of Acids and Bases

ExStik TM ph Waterproof Meters

Appendix C. Vernier Tutorial

Neutralizing an Acid and a Base

Acid Base Titrations

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

Experiment 6 Titration II Acid Dissociation Constant

The Effects of Temperature on ph Measurement

Experiment 18: ph Measurements of Common Substances. Experiment 17: Reactions of Acids with Common Substances

To determine the equivalence points of two titrations from plots of ph versus ml of titrant added.

User Guide. ExStik TM ph (PH100 & PH110) and ORP (RE300) Waterproof Series Pens. Patent Pending

DISSOLVED OXYGEN PROBE

Introduction. ph = log [H + ]

USING TECHNOLOGY FOR DATA COLLECTION

The Determination of an Equilibrium Constant

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

1. To perform a potentiometric titration of a sample of Liquid Drano with hydrochloric acid.

TEACHER ACTIVITY GUIDE

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Instruction Manual HI Portable Waterproof Microprocessor Dissolved Oxygen Meter

Ion Selective Electrodes

ph: Measurement and Uses

Chapter 6. Solution, Acids and Bases

Rauserv Steam Sterilizers, Laboratory and Hospital Equipment. Brewery Laboratory Equipment

Experiment 17: Potentiometric Titration

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

ANALYSIS OF VITAMIN C

DETERMINATION OF PHOSPHORIC ACID CONTENT IN SOFT DRINKS

6 H2O + 6 CO 2 (g) + energy

RBS detergents for laboratories

Chem 100 Lab Experiment #9 - ACID/BASE INDICATORS

YSI Meter Protocol: Specific Conductivity, ph, & Dissolved Oxygen

Understanding Analytical Chemistry (Weighing, Mixing, Measuring and Evaluating)

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

Portable Waterproof ph/dissolved Oxygen Meter

The Empirical Formula of a Compound

DNA SPOOLING 1 ISOLATION OF DNA FROM ONION

Evaluation copy. Titration of a Diprotic Acid: Identifying an Unknown. Computer

ph Test #1: Scaling Common Liquids (From a series of 5)

Electrochemistry Revised 04/29/15

Archived. Gloves should be changed frequently during the analysis.

TEACHER ACTIVITY GUIDE

MOISTURE (Karl Fischer, Buffered)

Osmosis. Evaluation copy

Measuring the Conductivity of Pure Water Using USP<645>

Trace Dissolved Oxygen Sensor

A PRIMER ON ph. A Presentation for ASTA Conference September 30-October 1, 2008

Chloride and Salinity

Determining the Identity of an Unknown Weak Acid

PN /rev. D December Theory and Practice of ph Measurement

EXPERIMENT 4 Acid Strength

the importance of ph in water purification the importance of ph in water purification Water Purification Systems UK

For all turfgrass areas. Now you can test soil reaction at different levels in the soil profile. Check Soil ph on:

Chem 1B Saddleback College Dr. White 1. Experiment 8 Titration Curve for a Monoprotic Acid

Measurement by Ion Selective Electrodes

9. Analysis of an Acid-Base Titration Curve: The Gran Plot

Acids and Bases. AND a widemouth container of the following solids:

Care and use guide. Contents. a handy solution made easy. page

Household Acids and Bases

GA/7 Potentiometric Titration

Titanium Dioxide Raspberry Solar Cell 2012, 2011, 2005 by David A Katz. All rights reserved

AN EXPERIMENT IN ALCHEMY: COPPER TO SILVER TO GOLD 2005, 2000, 1996 by David A. Katz. All rights reserved

Shampoo Properties Evaluation General Science

Transcription:

Measuring ph in Acidified Foods Find out all you need to know about measuring ph in acidified foods. XX XX

Table of Contents Why ph Matters pg 4 What You Need pg 8 How To Measure pg 16

Why Introduction ph Matters To succeed in creating high quality foods, analysis should be at the heart of your strategy. Quantitative analysis needs to be a driving force behind decision-making for food formulations, quality control, and food safety. Analytical testing can easily be integrated into the food production process. From hobbyists to food scientists, many involved in food quality and safety now use a variety of analytical techniques to create stable, safe, and most of all, great tasting foods. Analyzing data is of no use unless the data represents the actual condition of the food. The quality of analytical data depends on proper sampling, appropriate method selection, and effective measurement techniques. This ebook will discuss how to utilize ph testing to ensure food quality and safety. It will cover how ph affects food quality, as well as the necessary tools and suggested measurement procedures, which will be highlighted for liquid, semisolid, and solid food samples. 3

Why ph Matters What is ph? In technical terms, ph is the hydrogen ion activity in a solution. The equation is commonly written as: ph = -log [H+] This equation will determine ph according to a scale from ph 0 to 14, with solutions less than ph 7 being acidic and solutions greater than 7 being basic. A ph of 7 is neutral and is neither an acid nor a base. How does ph affect food quality? Flavor Organic acids, such as citric acid, can provide a tart or sour flavor to foods. Fermentation ph affects bacteria used in food production to make cheese, yogurt, vinegar, and soy sauce, to name just a few. Yeast performs best at a ph of 4.5-6.0. Texture Texture is particularly susceptible to ph changes. Low ph will result in a cheese without shape or hold while high ph causes cheese to crumble. Appearance ph plays a role in haze formation and contributes to pigment. Anthocyanins, the red pigments found in berries, turn blue, green, or yellow in alkaline conditions. Shelf stability ph prevents spoilage by inhibiting bacterial growth. Bacteria, such as E.coli, require ph higher than 4.6 to thrive; anything lower will inhibit growth. 4

Why ph Matters Regulations The Code of Federal Regulations (CFR) is an annual edition of general and permanent rules produced by various US government agencies including the Food and Drug Administration (FDA). The methodology of ph measurement for food products and how they are processed can be found in 21CFR114. The classification of food, based on ph, is found in 21CFR114.3. This section divides foods into multiple groups based on their ph value, stating: Acid Foods are foods that naturally have a ph of 4.6 or below. Low-acid Foods are any foods, except alcoholic beverages, with a finished equilibrium ph values greater than ph 4.6 and a water activity greater than 0.85a w. Low acid foods can be ph adjusted by the addition of acid or acid foods to lower the ph to 4.6 or below. Acidification reduces the risk of contamination by bacteria such as C. botulinum. Even though a low-acid food can be acidified, high heat and pressure may still be required to adequately sterilize the product. 5

Why ph Matters Regulations (cont.) A low acid food that is ph adjusted is known as an Acidified Food. They are defined as: Having a water activity greater than 0.85a w Are stored and distributed under non-refrigerated conditions 21CFR114.8 states that frequent testing and recording of results should be performed. Manufacturing must be in accordance with a scheduled method, and acidified foods shall be thermally processed to destroy bacteria. 21CFR114.9 cites methodology for ph measurements: Use commercially prepared buffer. ph meter with accuracy to be approximately + 0.1 ph unit. Determine ph of samples at room temperature (25 ºC). Preparation of samples: - Direct insertion into liquid samples. - Solids and semisolids should be processed as a paste of uniform consistency. - Oil layers may be discarded to reduce clogging. 6

Why What ph You Matters Need 1. ph meter Must have Minimum 2 point calibration, automatic temperature compensation, 0.01 ph resolution, and a mv scale Good to have Built in electrode diagnostics, Cal Check, GLP - Good Laboratory Practice, data logging capability, and a USB port for transferring data. 2. ph electrode Must have Combination ph electrode ( both the glass and reference electrode are found in one body) Good to have Application specific electrode made for taking direct measurements of food products with a built-in temperature sensor for automatic compensation of temperature variations. Hanna Note CAL Check alerts users to potential problems during the calibration of the ph electrode. Indicators include Electrode Dirty/Broken, Buffer Contaminated, as well as the overall probe condition. GLP data includes date, time, buffers /standards used for calibration and slope/offset characteristics. This and the ability to log data are helpful in maintaining good record keeping as cited in 21CFR114.8. 7

Why What ph You Matters Need Juice HI10480 Wine/Juice Reference Electrode for Samples with Suspended Solids Milk FC101D Amplified ph electrode with PVDF body Cheese FC240B Small Diameter ph Electrode with Stainless Steel Body Semi-solids FC230B ph Electrode for Meat and Semi-Frozen Products Meats FC231 ph SMART Electrode for Meat and Semi-Frozen Products + FC099 Stainless Steel Blade (1.4 blade) 8

Why What ph You Matters Need 3. Calibration Solutions The calibration buffers used should bracket (see note) the expected sample ph. Generally, ph 4.01 and 7.01 buffers will bracket most food samples. The calibration is only as good as the buffer used. Any changes in ph of the buffer will result in an inaccurate reading. Once opened, buffers should be changed at least every six months. Hanna Note When calibrating a ph electrode it is important to choose buffers that bracket the expected reading. For example, if the expected reading is ph 4.2 then it would be best to calibrate to ph 4.01 and ph 7.01. If the expected reading is ph 3.2 then it would be best to use a ph meter that allows for custom buffers. There are many other buffers available other than the ph 4.01, 7.01 and 10.01. Hanna Instruments offers buffers from ph 1.00 through ph 13.00. 9

Why What ph You Matters Need 4. Cleaning Solutions Contamination on the glass sensing surface and clogged junctions are two of the most common reasons for poor electrode performance. In foods, this is particularly common because fat and protein residues can easily coat the electrode and clog the junction of the ph electrode. Application specific cleaning solutions are formulated to clean the ph electrode based on the sample composition. For example, the HI7073 is an enzymatic cleaner for cleaning proteins. Application specific cleaning solutions made by Hanna include general, protein coating, inorganic soak, and an oil and grease rinse. Hanna Note Handling the glass tip of the electrode or wiping it clean with a cloth can damage the sensor, resulting in inaccurate measurements. 10

Why What ph You Matters Need 5. Storage Solutions A dry ph electrode can contribute to poor performance. A ph electrode will display one ph value when dry and a different value when hydrated. Every glass ph electrode will form a hydrated layer on the glass. It takes around 3-4 hours for the hydration layer to completely form. A storage solution is designed to keep the electrode bulb hydrated. Storage solutions are also formulated to prevent organic growth which can coat the electrode bulb. Hanna Note Never use deionized (DI) water for a storage solution. The DI water will have an osmotic and diffusion effect on the reference cell. The concentrated salt solution found in the reference cell will change. If altered too much, the solution will have to be replenished. For a gel-filled electrode, the probe will have to be replaced. 11

Why What ph You Matters Need 6. Fill Solutions Fill Solution: The filling solution of a ph electrode diffuses slowly from the inside of the ph electrode, losing anywhere from 15 45 μl/hour (0.33 to 1 drops/hour). The fill solution must be topped off to maintain a proper level. Reference Fill Cap Good Electrloyte 1/2 Level Refill with proper electrolyte below this level Hanna Note Refillable ph electrodes are available in a single junction and double junction design. Single junction ph electrodes use a 3.5 M KCl solution with AgCl while a double junction electrode uses 3.5M KCl without AgCl. 12

Why What ph You Matters Need Additional items for a good testing set up: Magnetic stirrer: A stirrer should have variable speed control to allow for proper sample mixing. Mixing will ensure a faster electrode response, greater stability, and more accurate measurements. HI181-1 Electrode holder: An electrode holder will help hold the electrode in the correct position for measurement. A holder will also help to avoid damage to the glass ph bulb by holding it in a secured position. HI76405 Labware: 100 ml beakers for samples to be tested, 500 ml waste beaker, and a laboratory wash bottle with deionized or distilled water. HI70036P 13

Why What ph You Matters Need An Ideal ph Meter Makes Testing Easy Flexibility: Today s meters offer a wider range of flexibility. A portable meter offers the ability of in-field use with the performance of a benchtop. Ease of use: Measurement, configuration, calibration, and logging should be easy to do with data management features including direct / USB data transfer. Simple maintenance: Advanced ph meters have diagnostics capability to inform of problems during the calibration process. Diagnostic messages should include the overall probe condition and whether the probe should be cleaned, or if the buffer is contaminated. HI98190 14

Why What ph You Matters Need HI99161 HI98190 HI2002 HI5222 General Information Type Portable & Waterproof Perfect for: Field Use Type Portable & Waterproof Perfect for: Field Use Type Portable/Benchtop Perfect for: Field Use/Lab Type Benchtop Perfect for: Lab Data Connectivity N/A Connectivity USB Port Connectivity 2 USB port for PC and storage Connectivity USB Port Logging No Logging 200 samples Logging 1,000 samples Logging 100,000 data point storage Special Features ATC Yes ATC Yes ATC Yes ATC Yes Cal Check No Cal Check Yes Cal Check Yes Cal Check Yes GLP No GLP Yes GLP Yes GLP Yes Calibration Point(s) One or two calibration points Calibration Point(s) Up to five calibration points Calibration Point(s) Up to five calibration points Calibration Point(s) Up to five calibration points ATC - (Automatic Temperature Compensation) Cal Check - Alerts users to potential problems during the calibration of the ph electrode (unique to Hanna meters) GLP - (Good Lab Practices) Ensures consistency and reliability of your tests Calibration Point(s) - The more calibrations you have the more accurate your readings will be 2.5 2.75 5.5 3.5 2.5 inch (diagonal) 2.75 inch (diagonal) 5.5 inch (diagonal) 3.5 inch (diagonal) 15

Before You Measure 1. Calibration The following procedure is based on the best practice of using two beakers for each calibration buffer. a. Prepare the electrode. Remove the protective/storage cap from the electrode. If the ph bulb is dehydrated, place in storage solution for at least 3-4 hours. If the ph electrode is a refillable design, then remove the fill hole screw cap. b. Prepare the calibration buffers. Fill two beakers with enough ph buffer solution 7.01 to cover the ph electrode junction (approximately 75 ml in a 100 ml beaker). One of the beakers will be used to rinse the ph electrode and the other for the actual calibration. Repeat for any other ph buffer (i.e. ph 4.01) that is used. 16

Before You Measure c. Perform a two point calibration Rinse the ph electrode with Deionized water. Rinse the ph electrode in the ph 7.01 rinse beaker. Place the electrode in the ph 7.01 calibration beaker and stir. Wait for the reading to stabilize and confirm the calibration. Repeat this procedure for the second point with ph 4.01 buffer. Hanna Note Calibration parameters to monitor include slope and offset. When a ph probe is placed in a solution, a voltage is generated. The offset of a probe is the mv reading in ph 7 buffer. The slope of a probe is based on the mv difference between two buffer solutions. A probe should always have a slope minimum of 85%, ideally greater than 90% slope and any probe with an offset outside +/- 30 mv should be cleaned and conditioned prior to use. These parameters provide information on the probe s overall condition. To learn more about how to calculate your slope and offset click here to download Calculating Your Slope and Offset Cheat Sheet or watch the video on How to check the slope and offset of a ph meter 17

Taking a Measurement 2. Measure a. Procedure for liquid samples Do not start taking measurements unless the ph electrode has been properly hydrated and calibrated. Fill two beakers with enough sample to cover the ph electrode junction (approximately 75 ml in a 100 ml beaker). Use one of the beakers to rinse the ph electrode and the second for the actual measurement. Rinse the probe with deionized water Place the electrode in the rinse sample beaker. Place the sample beaker to be measured on a magnetic stirrer and drop a clean magnetic stir bar into it. If available, place the ph electrode into the electrode holder and lower it until the junction is fully immersed. Wait for the reading to stabilize before recording the measurement. 18

Taking a Measurement b. Procedure for semi-solid and solid samples Direct Measurement with application specific ph electrodes Do not start taking measurements unless the ph electrode has been properly hydrated and calibrated. If a solid, use a knife or auger to make a hole for the ph electrode. Insert the tip of the probe into the hole. Ensure that the electrode junction is covered by placing the electrode at least 2cm (0.75 ) into the sample. Wait until the ph reading is stable before recording. Hanna Note The measurement of solid and semi-solid samples is difficult. Either a specialized electrode that is designed to take a direct measurement is needed, or the sample has to be pretreated (i.e. made into a slurry) so that a standard ph electrode can be used. 19

Taking a Measurement Meats FC231 ph SMART Electrode for Meat and Semi-Frozen Products + FC099 Stainless Steel Blade (1.4 blade) Hanna Note Some Food Care ph electrodes offer the option to use a stainless steel blade. The blade is used to pierce the sample and protect the glass ph bulb. 20

Taking a Measurement b. Procedure for semi-solid and solid samples (cont.) Slurry Method for ph Measurement The slurry method involves taking a sample mixed with deionized/distilled water to make a solution that can be tested. 21CFR114.9 (Council for Federal Regulation) recommends 10-20 ml of distilled water should be added to each 100 grams of product. The mixture is homogenized and the resultant slurry tested. The testing procedure would then be the same as a liquid sample. Hanna Note The addition of distilled/deionized water should have little effect on the ph of the sample since the water has no acidity/alkalinity (buffering capacity). It takes very little effort to change the ph of high purity water. Click Here to Read Our Case Study: Comparison of ph Measurements of Food Products Using Various ph Electrode Designs and Sample Preparations 21

After You Measure 3. Cleaning a ph electrode Once you are finished measuring your samples, slide the ph electrode from the electrode holder and rinse it with water until all food residues are removed. Periodically the ph electrode should be cleaned with a ph electrode cleaning solution. The cleaning procedure is: Fill a 100ml beaker with approximately 75 ml cleaning solution. Place the ph electrode into the cleaning solution, making sure the junction is covered. Soak for 10 to 15 minutes. Rinse the electrode with DI water. Soak in storage solution for at least two hours before next use. Hanna Note Knowing the offset (mv value in ph 7.01 buffer) is a great way to know if the probe needs to be cleaned. A new ph electrode will have an offset of +/- 15 mv. A large change is an indication that the probe is coated and requires maintenance. A meter with GLP option will display the offset. 22

After You Measure 4. Storing a ph electrode Fill the storage cap of the ph electrode to the half point with storage solution and replace the storage cap on the electrode. Make sure there is enough storage solution in the cap to cover the tip of the ph electrode. For refillable ph electrodes, check to see if the probe needs to be refilled. The fill solution should be less than a half-inch below the fill. 23

THANKS FOR READING! Our experts are here to help you. Visit us at hannainst.com Email us at sales@hannainst.com Call us at 1 (877) MY-HANNA LEARN MORE about Hanna s full line of food products