Instant Connect Gas Sampling Valve Module Introducing a New Flexibility in Gas Sampling for GC and GC-MS

Similar documents
Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

23 The Thermal Conductivity Detector

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity

Gas Chromatography Liner Selection Guide

Thermo Scientific ConFlo IV Universal Interface

A fully quantitative research method for the analysis of lead in whole blood using the Thermo Scientific icap Q ICP-MS

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Third Party Instrument Control with Chromeleon Chromatography Data System (CDS) Software

Thermo Scientific Compound Discoverer Software. A New Generation. of integrated solutions for small molecule structure ID

Chemical Analysis. Natural Gas Analyzer. A Family of optimized GC Solutions. Gas Chromatography. think forward

Simultaneous Quantitation of 43 Drugs in Human Urine with a Dilute-and-Shoot LC-MS/MS Method

Thermo Scientific icap 7000 Series ICP-OES. Low cost ICP-OES analysis high quality data

Transformer Oil Gas Analysis

TargetQuan 3 Software. Leading the way in regulatory. POPs quantification. Bullet Bullet Bullet

How To Control A Record System

PLOT Columns. Top: Bob Langford, GC Column Manufacturing Technician Bottom: Stephanie Sunner, Customer Service Representative

Thermo Scientific PepFinder Software A New Paradigm for Peptide Mapping

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Addressing the World Helium Shortage For Gas Chromatography

CHROMOCTANE O N LINE ANALYZER

Selective Testosterone Analysis in Human Serum by LC-FAIMS-MS/MS

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

Thermo Scientific Dionex Chromeleon 7 Chromatography Data System Software

ADVANCEMENTS IN MICRO GAS CHROMATOGRAPHY (GC)

Get the benefits of Norgren s unique range of Online services

Thermo Scientific SIEVE Software for Differential Expression Analysis

AC DHA Solutions. Detailed Hydrocarbon Analysis of Light Petroleum Streams & Light End in Crude Oils. ASTM D 5134, D 6729, D 6730, D 6733 Compliance

Clarus 580 Gas Chromatograph

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Agilent 7697A Headspace Sampler Data Sheet

Get the Right GC for Your Industry

Hydrogen as an alternative to Helium for gas chromatography.

THERMAL DESORPTION. Introduction and Principles. Focusing on Volatiles

Fundamentals of Gas Chromatography

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Thermal Conductivity Detector

What is Eluent Generation?

A Complete Solution for Method Linearity in HPLC and UHPLC

[ Care and Use Manual ]

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

Gas Chromatograph GC Consumables. p/n:

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Natural Gas Processing Solutions Using the 700XA Gas Chromatograph

Thermo Scientific LIFECYCLE Asset & Service Management for Healthcare

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

C184-E014D GC Shimadzu Gas Chromatograph System

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

BTU ANALYSIS USING A GAS CHROMATOGRAPH

Fractional Distillation and Gas Chromatography

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index

Process Instrumentation

GC Troubleshooting 10. How to use this Troubleshooting Help system GC Troubleshooting - Top Level Generic problem descriptions...

The Use of Hydrogen Carrier Gas for GC/MS

ChromQuest 5.0 Chromatography Data System

QIAsymphony RGQ Protocol Sheet

Gas Chromatography. Let s begin with an example problem: SPME head space analysis of pesticides in tea and follow-up analysis by high speed GC.

GC METHODS FOR QUANTITATIVE DETERMINATION OF BENZENE IN GASOLINE

Transforming a ChromLab Software 2-D Purification Template into an Automated Multidimensional (Multi-D) Purification Workflow An Instructional Guide

Valves for Safety Applications

Updating the QIAcube operating software

A VISION to On-Line SPE PTV GC MS Determination of Organic Micro Pollutants in Surface Water

Agilent 4338B Milliohm Meter

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Comparison of the Reversed-Phase Selectivity of Solid Core HPLC Columns

802.11ac Power Measurement and Timing Analysis

WATERS QUANTITATIVE ANALYSIS solutions

PXI and AXIe Modular Instrumentation

Application of Automated Data Collection to Surface-Enhanced Raman Scattering (SERS)

Split / Splitless Injection for Capillary GC

SCION SQ Series GC-MS

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

INTRODUCTION. The principles of which are to:

GC-2010 Gas Chromatograph INSTRUCTION MANUAL

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Theory and Instrumentation of GC Introduction

On-line Dissolved Gas Analysis

Agilent Television Power Consumption Testing. Application Note

LIFECYCLE. Thermo Scientific. Enterprise Solutions

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Expectations for GC-MS Lab

W- Series. Features: WOB. Mechanical Data Case : Moulded plastic. Lead : Solder plated. Weight : 1.10 grams. Page <1> 15/07/08 V1.

Chromatograph Maintenance and Troubleshooting Class # 5050

Accuracy counts! SENSORS WITH ANALOG OUTPUT

Optimize Your Process Operations by Improving Process Monitoring

UniFlux 10: hollow fiber conversion kit ( ) installation instruction

Diode, Schottky SMB/DO-214AA. Page <1> 24/04/08 V1.1. Dimensions Inches (Millimeters)

ProteinChip Energy Absorbing Molecules (EAM)

PCI Express 1.0 (2.5 GT/s) Protocol Test

Network And Internet Management Services Telecoms Pricing

Background Information

We decided that we would build IFS Applications on standards so our customers would not be locked into any particular technology. We still do.

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

Hydraulic. Manifold ON/OFF ISOLATION CONTROL FOR TEST SYSTEMS AND HYDRAULIC ACTUATORS WHAT MOVES YOUR WORLD. Rev.-, October 2011

Designed for multi-injector endurance testing, the

Transcription:

Instant Connect Gas Sampling Valve Module Introducing a New Flexibility in Gas Sampling for GC and GC-MS Stefano Pelagatti, Paolo Magni, and Fausto Pigozzo Thermo Fisher Scientific, Milan, Italy

Overview Purpose: We present a newly developed, Instant Connect gas sampling valve (GSV) module for the Thermo Scientific TRACE 1300 Series Gas Chromatograph (GC). Gas injection through a gas sampling valve is one of the most reliable and wide-spread techniques to inject a vapor sample into a gas chromatographic system. Today, development of this technology relies on the attempt of different valve suppliers to improve material reaching higher temperature and/or longer life time of mobile parts, reduce internal volumes for improving chromatographic performance and reduce overall valve size. Introduction This paper describes a new modular concept that has been undertaken to integrate the latest valve technology, into a hand-held plug-in module, fully incorporating heating control of the valve, miniaturized pneumatic circuits for carrier gas supply and split, as well as valve backflush to the vent. This modular design allows a new level of instrument flexibility, where inlets and/or detectors selection is based on the application in use, and can be changed in a matter of a few minutes by the operator when a new analytical need or application requires different injector and/or detectors. In addition to improved technical performance in terms of injection repeatability and stability, this work shows the simplicity and flexibility in configuration settings provided by this instant connect modular design. Without further hardware complexity, the gas sampling valve module can be set to back flush to vent the undesired part of sample, therefore offering an easy and integrated set-up for more complex analysis. Data showing performance of this solution are illustrated and discussed. Methods For the work, a TRACE 1300 Series GC equipped with an Instant Connect Gas Sampling Valve (GSV) module (Figure 1) as injection port and a TCD detector module in series with a FID detector module has been used. In Figure 2, the GC setup is shown. Moreover, for the determination of N2O in ambient air, the ECD detector have been used. 2 Instant Connect Gas Sampling Valve Module Introducing a New Flexibility in Gas Sampling for GC and GC-MS

FIGURE 1. Instant Connect GSV module. FIGURE 2. TRACE 1300 GC equipped with GSV module and FID-TCD in series. The GSV module is provided with all the electronics and pneumatics built into the module (Figure 3), including the parts necessary for the backflush option. The GSV module is a thermostatted (up to 150 C) 6-ports membrane valve. The valve has a constant purge of helium in order to avoid any possible air diffusion through the membrane, particularly critical when used in combination of oxygen sensitive detectors. The channels in contact with the sample are fully surfacedeactivated in order to prevent corrosion or absorption phenomena, especially for sulfur components at low concentration levels. Two charcoal filters, one on the carrier line and the other on the split line, can be replaced without any intervention on the valve connections. Thermo Scientific Poster Note PN10389_ISCC_2014_E_05/14S 3

FIGURE 3. GSV module pneumatics. The performance of the new GSV module has been evaluated using a certified gas mix (from S.I.A.D. S.p.A TM ). The composition of the tank is described in the following table: TABLE 1. Gas mix. Gas % Volume/Volume Oxygen 1.08 Hydrogen 2.99 Methane 2.99 CO2 3.00 CO 3.00 N2 3.02 Helium Remaining part The column used is: Thermo Scientific TracePLOT TG-BOND M Sieve 5A 30 m, 0.53 mm, 50 µm. The precolumn is: Thermo Scientific TracePLOT TG-BOND Q, 5 m, 0.53 mm, 20 µm. Such a precolumn has been chosen in order to allow a precise backflush cut of unwanted portion of the mix. The AFP TM diaphragm is equipped with a 250 loop made by SilcoNert TM coated stainless steel tube. Results The loop have been loaded in continuous way with gas mix through the Sample In port of the module with a flow of 5 ml/min. The sampling occurred automatically whenever the GC was ready to inject. The chromatograms obtained with the FID and TCD are presented in Figure 4. The method used is listed in Table 2. The backflush valve was actuated after 1.6 minutes in order to preserve the molecular sieve column, avoiding the entrance of CO2. The backflush time optimization requires few trials: it starts with an early reverse flow actuation, then the actuation start time is incremented until the last eluting peak before the undesired component is acquired in the chromatogram. 4 Instant Connect Gas Sampling Valve Module Introducing a New Flexibility in Gas Sampling for GC and GC-MS

The duration of sampling valve activation was 0.5 min, long enough to transfer completely the components from the loop into the column, considering the low dead volumes of the module. FIGURE 4. Standard gas mix chromatograms. N2 CH4 CO TCD O2 H2 CH4 FID TABLE 2. GC analytical method. Oven Method FID - Front Method Initial temperature: 30.0 C Temperature: 250 C Initial hold time: 2.00 min Ignition threshold: 1.0 pa Number of ramps: 1 Air flow: 350.0 ml/min Ramp rate: 20.0 C/min Hydrogen flow: 35.0 ml/min Final temperature: 100.0 C Makeup gas flow: 40.0 ml/min Ramp hold ti 2.00 min TCD - Back Method GSV - Front Method Temperature: 100 C S/SL mode Split Filament power on: Yes Temperature enable: On Filament temperature: 150 C Temperature: 120 C Reference gas enable: On Split flow enable: On Reference gas flow: 1.0 ml/min Split flow: 5.0 ml/min Carrier source: Front GSV inj start time: 0.00 min Acquire data: Yes GSV inj duration: 0.50 min Signal process: Standard Peaks Carrier mode: Constant Flow Negative polarity: No Carrier flow 5.000 ml/min Prep-run - TCD (Back): Autozero Thermo Scientific Poster Note PN10389_ISCC_2014_E_05/14S 5

TABLE 3. Peak area and retention times repeatability. area H2 O2 N2 CH4 CO RT H2 O2 N2 CH4 CO inj1 13266 250735 759165 660911 780563 inj1 2.898 3.355 4.150 4.800 6.105 inj2 13125 248391 749634 653404 772619 inj2 2.898 3.355 4.150 4.798 6.103 inj3 13225 247587 748704 652229 771518 inj3 2.900 3.357 4.150 4.798 6.103 inj4 13175 249261 752844 655866 775850 inj4 2.895 3.352 4.147 4.795 6.100 inj5 13197 248333 749910 653122 773409 inj5 2.898 3.355 4.148 4.797 6.102 inj6 13182 248458 750457 654182 774973 inj6 2.897 3.353 4.150 4.798 6.103 inj7 13200 249554 753400 656871 776464 inj7 2.898 3.355 4.150 4.798 6.103 inj8 13159 248388 750503 654086 774620 inj8 2.900 3.357 4.152 4.800 6.105 inj9 13091 247615 748039 652954 771570 inj9 2.898 3.355 4.150 4.798 6.103 inj10 13107 247545 749047 653151 771920 inj10 2.898 3.355 4.150 4.798 6.103 inj11 13195 249232 754607 658199 777982 inj11 2.898 3.355 4.150 4.797 6.100 inj12 13019 245449 743166 647715 765810 inj12 2.902 3.357 4.150 4.798 6.100 inj13 13169 246423 746294 650646 769293 inj13 2.897 3.353 4.148 4.797 6.100 inj14 13191 249165 753737 657913 778070 inj14 2.898 3.355 4.150 4.798 6.102 inj15 13126 247865 750023 654019 773525 inj15 2.897 3.353 4.150 4.798 6.102 inj16 13091 247573 748145 652019 770972 inj16 2.900 3.357 4.152 4.798 6.103 inj17 13161 249634 754156 656949 777327 inj17 2.897 3.353 4.148 4.797 6.100 inj18 13140 247480 749380 653754 773162 inj18 2.898 3.355 4.150 4.797 6.102 inj19 12986 247612 747750 651951 770890 inj19 2.898 3.355 4.150 4.797 6.100 inj20 13210 249962 754972 658039 778727 inj20 2.900 3.355 4.152 4.798 6.102 inj21 12985 246524 743554 648850 767180 inj21 2.897 3.353 4.150 4.797 6.102 inj22 13153 249329 752502 656392 776874 inj22 2.898 3.355 4.150 4.798 6.102 inj23 13328 251266 758369 660696 782013 inj23 2.897 3.353 4.148 4.797 6.100 inj24 13213 250395 755861 658918 779669 inj24 2.897 3.353 4.148 4.795 6.098 inj25 13077 247541 749738 653407 773632 inj25 2.898 3.355 4.150 4.797 6.100 sd 81 1401 4013 3376 4060 sd (min) 0.001 0.001 0.001 0.001 0.002 RSD% 0.6 0.6 0.5 0.5 0.5 RSD% 0.05 0.04 0.03 0.03 0.03 The efficiency of the embedded backflush system has been tested using the same gas mix, but changing the backflush activation time (from 1.6 minutes to 1.4 minutes). The result evidences that a selective cut of the methane peak can be obtained, as showed in Figure 5. FIGURE 5. Selectivity of the backflush cutting. BKF at 1.4 min N2 CO O2 The methane has been precisely backflushed H2 BKF at 1.6 min N2 CH4 CO O2 H2 Using different detectors, columns and larger sampling loops, this on-line ambient monitoring can be used for various applications like continuous air pollution evaluation. 6 Instant Connect Gas Sampling Valve Module Introducing a New Flexibility in Gas Sampling for GC and GC-MS

like continuous air pollution evaluation. In Figure 6, an example of ambient air analysis performed using an ECD detector and TracePLOT TG-BOND Q phase column for the quantification of fractions of ppm of N2O is showed. FIGURE 6. Continuous ambient air monitoring. Conclusion The new instant connect GSV module, easily installable on the TRACE 1300 series GC, has demonstrated to be a robust and reliable device for the detection and analysis of permanent gases or volatile compounds. The embedded backflush capability enables the protection of the column from unwanted components, reducing the analysis time and preserving the column lifetime. www.thermoscientific.com 2014 Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Africa +43 1 333 50 34 0 Australia +61 3 9757 4300 Austria +43 810 282 206 Belgium +32 53 73 42 41 Canada +1 800 530 8447 China 800 810 5118 (free call domestic) 400 650 5118 Denmark +45 70 23 62 60 Europe-Other +43 1 333 50 34 0 Finland +358 9 3291 0200 France +33 1 60 92 48 00 Germany +49 6103 408 1014 India +91 22 6742 9494 Italy +39 02 950 591 Japan +81 45 453 9100 Latin America +1 561 688 8700 Middle East +43 1 333 50 34 0 Netherlands +31 76 579 55 55 New Zealand +64 9 980 6700 Norway +46 8 556 468 00 Russia/CIS +43 1 333 50 34 0 Thermo Fisher Scientific, Austin, TX USA is ISO 9001:2008 Certified. Singapore +65 6289 1190 Spain +34 914 845 965 Sweden +46 8 556 468 00 Switzerland +41 61 716 77 00 UK +44 1442 233555 USA +1 800 532 4752 PN10389_E 05/14S