NKV. Series HEATERS. Designation key: Accessories. Series Flange diameter [mm] - Number of water coil rows NKV 100; 125; 150; 160; 200; 250; 315 2; 4

Similar documents
RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

2-Port Self-acting Temperature Control Valve Selection for Heating and Cooling Applications

Thermostatic element RAVV for 2-way valves

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

HEAVY DUTY STORAGE GAS

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)


Solar Hot Water Heaters

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

FLASH TANK ECONOMIZER PRODUCT GUIDE

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

HDA

CADB and CADT-D / DI / DC Series

Technical data. Danfoss DHP-A

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

RPV - RP - RA air handling units

PHOTOVOLTAIC (PV) solar panels. Specification. Electricity - CE & ISO 9000 certified. 83W panel. 180W panel Maximum power:

Control blocks for two-hand start ZSB

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Explosion-Proof Electric Unit Heaters

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Thermostatic valve Type AVTA

Installation and maintenance instructions. Danfoss Vent

3/2-way Solenoid Valve, direct-acting, NC or NO

Globo P. Ball valves Pump ball valve made of gunmetal

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

FAN COIL UNIT SOFTWARE User Manual

COMMISSIONING OF HVAC SYSTEMS

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

Transformer oil cooler ALFA A02

SWIMMING POOL HEAT PUMP Owners Manual

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

Itho Products for Hot and Boiling water. product-

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Accumulators and Receivers

Installation, operation and maintenance manual TX 35A

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

HVAC Sensors Catalogue

ECOCIAT. Domestic hot water heat recovery unit

NAVIEN AMERICA INC FITCH AVENUE

ELECTRIC CENTRAL HEATING FLOW BOILER

SERVER ROOM CABINET INSTALLATION CONCEPTS

Advances in Gas Cooler Design and the New Gas Cooler Product Selector

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Commercial Gas Furnace Upflow

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

REGULATORS 175/153 Series

VAD. Variable Area Desuperheaters

SOLENOID VALVES AND PNEUMATIC VALVES

Cased/Uncased Coils For Gas And Oil Furnaces

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Cool Design for Homes and Offices

Heat. Investigating the function of the expansion valve of the heat pump. LD Physics Leaflets P Thermodynamic cycle Heat pump

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

TWE+TTA TWE+TWA T.R.

MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

Airline. small air handlers and extract fan units. VES Airline part of a complete range of innovative, flexible products from the HVAC experts

GTS. New! Plus: PR0DUCT CATALOG. Vapor-logic 4 controller with: and LonTalk. New models GTS-500 and GTS-700. Gas-to-Steam Humidification System

VAD Variable Area Desuperheaters

Topvex SX/C, Topvex TX/C. Air Handling Unit

UDSA - UDSBD unit heater

Operators manual Basic water heater

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Spare Parts List M96A.24SM/B M96A.28SM/B

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Labotek Spare Partlist

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

Cooking at the Speed of light!

3/2-way Mini Solenoid Valve

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Valve systems Base plates, according to standard ISO Brochure

Equipment Information

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Self-operated Temperature Regulators Temperature Regulator Type 1u

M A N U A L

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

Powers Controls TH 192 S Single Temperature Room Thermostat

GCS

Transcription:

HEATERS Series Applications Duct water heaters are designed for heating of supply air in round ventilation systems. They can be also applied in supply or supply and exhaust ventilating units. Design The heater casing is made of galvanized steel, the tubular coils are of copper tubes and the heat exchange surface is made of aluminium plates. The heaters are equipped with rubber seals for airtight connection to the air ducts. The heaters are ailable in 2 and 4 rows modifications and are designed for maximum operating pressure 1.6 MPa (16 bar) and maximum water operating temperature +100 С. The outlet manifold has a branch pipe for installation of submersible temperature probe or icing protecting device. The heater is equipped with a nipple for the system deaeration. Mounting The heater design ensures its mounting on the round ducts in any position by means of clamps. The water heating coils can be installed in any position that enables the heater deaeration. The air flow direction shall match the pointer designation on the heater. The mounting shall be performed in such a way as to enable the uniform air stream distribution along the whole cross section. The air filter shall be installed at the heater inlet to protect the heating elements against pollution. The heater can be installed at the fan inlet ot outlet. If the heater is located at the filter outlet the air duct between the heater and the filter shall have the length of at least two connecting diameters to ensure the air flow stabilization as well as permissible air temperature level inside the fan. The heater shall be connected on the counterflow basis, otherwise its efficiency can drop by 5-15%. All the nomographic charts in the catalogue are valid for such connection. If water serves as a heat medium the heaters are suitable for indoor installation only. For outdoor installation use antifreeze mixture, i.e. ethylene glycol solution. To ensure the correct and safe heater operation use the automation system that provides complex control and freezing protection: automatic control of the heating capacity and air heating temperature; switching ventilating system on after preliminary heating with the heater; use of air curtains equipped with spring-loaded actuator; filter checking by means of differential pressure sensor; fan shutdown in case of the heater freezing danger. Connection against air flow Connection along air flow Designation key: Accessories Series Flange diameter [mm] - Number of water coil rows 100; 125; 150; 160; 200; 250; 315 2; 4 page 424 406

WWW.VENTILATION-SYSTEM.COM Overall dimensions: Type Dimensions [mm] D B H H3 L L1 L2 L3 K Number of water coil rows 100-2 99 350 230 150 300 32 43 220 G 3/4 2 3.9 100-4 99 350 230 150 300 28 65 220 G 3/4 4 5.2 125-2 124 350 230 150 300 32 43 220 G 3/4 2 4.0 125-4 124 350 230 150 300 28 65 220 G 3/4 4 5.3 150-2 149 400 280 200 300 32 43 220 G 3/4 2 7.5 150-4 149 400 280 200 300 28 65 220 G 3/4 4 8.2 160-2 159 400 280 200 300 32 43 220 G 3/4 2 7.5 160-4 159 400 280 200 300 28 65 220 G 3/4 4 8.2 200-2 198 400 280 200 300 32 43 220 G 3/4 2 7.5 200-4 198 400 280 200 300 28 65 220 G 3/4 4 8.2 250-2 248 470 350 270 350 32 43 270 G 1 2 10.3 250-4 248 470 350 270 350 28 65 270 G 1 4 10.8 315-2 313 550 430 350 450 57 43 370 G 1 2 12.6 315-4 313 550 430 350 450 53 65 370 G 1 4 13.4 Weight [kg] HEATER 407

HEATERS Air Speed. Starting from 250 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.75 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -15 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (90/70 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+17,5 С). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature -15 C (red curve) and draw a horizontal line from this point to the right until it crosses water in/out temperature curve (90/70 C), from here draw a vertical line up to the scale representing the heating coil capacity (3.25 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.042 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (2.9 kpa). Air Speed. Starting from 250 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.75 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -15 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (80/60 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+27 С). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature indicated as red curve (e.g., -15 С) and draw a horizontal line from this point to the right to the intersection of water in/out temperature curve (e.g., 80/60 С). From this point draw a vertical line up to the scale of heating coil capacity (5.2 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.067 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (5.2 kpa). 408

WWW.VENTILATION-SYSTEM.COM Air Speed. Starting from 700 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 4.4 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -10 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (90/70 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+21 C). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature indicated as red curve (e.g., -10 С) and draw a horizontal line from this point to the right to the intersection of water in/out temperature curve (e.g., 90/70 С). From this point draw a vertical line up to the scale of heating coil capacity (8.6 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.11 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (8.2 kpa). HEATER Air Speed. Starting from 700 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 4.4 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -25 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (70/50 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+26 C). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature indicated as red curve (e.g., -25 С) and draw a horizontal line from this point to the right to the intersection of water in/out temperature curve (e.g., 70/50 С). From this point draw a vertical line up to the scale of heating coil capacity (13.0 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.16 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (15 kpa). 409

HEATERS Air Speed. Starting from 1000 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.4 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -20 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (90/70 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+20 C). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature indicated as red curve (e.g., -20 С) and draw a horizontal line from this point to the right to the intersection of water in/out temperature curve (e.g., 90/70 С). From this point draw a vertical line up to the scale of heating coil capacity (15.5 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.19 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (11.0 kpa) Air Speed. Starting from 1000 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.4 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -20 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (70/50 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+28 C). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature indicated as red curve (e.g., -20 С) and draw a horizontal line from this point to the right to the intersection of water in/out temperature curve (e.g., 70/50 С). From this point draw a vertical line up to the scale of heating coil capacity (19.0 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.23 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (17.0 kpa). 410

WWW.VENTILATION-SYSTEM.COM Air Speed. Starting from 1500 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.2 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -20 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (90/70 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+21 C). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature (e.g. -20 C, red curve) and draw a horizontal line from this point to the right until it crosses water in/out temperature curve (e.g., 90/70 C), from here draw a vertical line up to the scale representing the heating coil capacity (23.0 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.28 l/s) Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (12.5 kpa). HEATER Air Speed. Starting from 1500 m 3 /h on the air flow scale draw a vertical line till the air speed axis which makes about 3.2 m/s. Supply air temperature. Prolong the line up to the point where it crosses the outside air temperature (blue curve), e.g. -20 C; then draw a horizontal line from this point to the left till crossing water in/out temperature curve (70/50 C). From this point draw a vertical line to the supply air temperature axis on top of the graphic (+28 C). Heating coil capacity. Prolong the line up to the point where it crosses the outside air temperature (e.g. -20 C, red curve) and draw a horizontal line from this point to the right until it crosses water in/out temperature curve (e.g., 70/50 C), from here draw a vertical line up to the scale representing the heating coil capacity (28.0 kw). Water flow. Prolong the line down to water flow axis at the bottom of the graphic (0.34 l/s). Water pressure drop. Draw the line from the point where line crosses the black curve to the pressure drop axis. (16.0 kpa). 411