Machine-roomless holeless hydraulic elevator

Similar documents
Skyrise. Engineered to meet the highest of challenges. The Skyrise system delivers:

Switch. Building technology for the real world.

Schindler 3100 Simple and practical. Our passenger elevator for small residential buildings really gets you moving.

OptiMiziNg the use Of SpacE KONE MaxiSpace

MACHINE ROOM-LESS PERFORMANCE IN A HYDRAULIC ELEVATOR HOISTWAY. KONE EcoSpace

Hydraulic Controllers, PHC, HS

KONE elevators for commercial buildings

Interfacing Elevators with Fire Alarm and Sprinklers

KONE solutions for airports

The KONE Motala 2000 platform lift suits the architecture of any building, thanks to the wide range of car and shaft design options.

STORAGE SPACE EFFICIENCY GUIDE A DEMONSTRATION IN SPACE

T12 COMPACT BATTERY-POWERED RIDER SCRUBBER. Experience the power of a heavy-duty rider scrubber and the maneuverability of a compact footprint

V1504 Vertical Platform Lift OWNER S MANUAL

S WORK CATALOGUE FAA29100H_BWC

Schindler 400AE Machine Room-less Elevator Dynamic. Durable. Distinguished.

INCREASED OPERATIONAL EFFICIENCY

Schindler 5500 Efficiency. Flexibility. Performance.

The Complete KASTO Program: Economic Sawing and Storing of Metal.

GeN2 TM CONVENTIONAL DRIVE CONVENTIONAL STEEL ROPES ❹ REGEN TM VF DRIVE LANDING CABINET ❶ FLEXIBLE COATED STEEL BELTS

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

NO 1 IN SMART HOUSE AND HIGH TECH BUILDING TECHNOLOGIES

RT100 ROUGH TERRAIN CRANE DATASHEET - IMPERIAL. Features:

MINNESOTA DEPARTMENT OF PUBLIC SAFETY State Fire Marshal Division STATEMENT OF POLICY. State Fire Marshal

Architectural Planning Guide

Rotary Screw Compressors UP-Series 4 & 5.5 kw

HEBDEN BRIDGE PICTURE HOUSE TECHNICAL INFORMATION FOR HIRERS UPDATED OCTOBER CAPACITY. Stalls: 257 Seats per row: 22(Max)

V1504 Vertical Platform Lift OWNER S MANUAL

Estimated Cost of Repair

OTIS /OTI BuyLine 1035 ELEVATOR PLANNING AND SELECTION GUIDE SELECTION PROCESS HYDRAULIC ELEVATORS GEN2 MACHINE ROOMLESS ELEVATOR ESCALATORS

MAXIMIZING UPTIME AND SAVINGS AKMETAL MADENCİLİK

ABB Drive Services Your choice, your future

Hanna delivers the technical and marketing expertise needed to produce a car wash that meets the car wash customer's expectations.

MACHINE-ROOM-LESS AND MACHINE-ROOM ELEVATOR SOLUTIONS KONE Scenic Elevators

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Elevator Security. General. In This Section. Several elevator security options are available for MCE Controllers. Basic Security

HYDRAULIC FREIGHT ELEVATOR PACKAGES

GE Energy Industrial Solutions. New. AF-6 Series Drives. Built-in features Built-in simplicity. GE imagination at work

It starts with a commitment to environmentally friendly solutions: Innovative products and services that reduce cost and energy usage.

American Academy of Physical Medicine and Rehabilitation Site Survey Report

Section 7: Elevators and Lifts. Main Entry Floor Outside the Elevator

DITCH WITCH MT12 MICROTRENCHER. ditchwitch.com

FOR LEASE UP TO 20,000 SQ.FT. OF RETAIL/RESTAURANT SPACE 2388 YONGE STREET TORONTO, ON

Automatic Door Selection Guide

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Atlet Balance Electric Counterbalance trucks ET EF EH tons

Data Center Trend: Distributed Power in the White Space

freight elevators 2008 planning guide ThyssenKrupp Elevator Americas Business Unit

Servo/Hydraulic Press Brake. HG Series HG 5020, HG 8025, HG 1303, HG 1703 HG 1704, HG 2203, HG 2204

301.7D. Mini Hydraulic Excavator

Built to carry an entire industry.

ITEM DESCRIPTION SPECIFICATION TENDER OFFER

Schindler 3300 AP A remarkable style that suits the building. The machine room-less passenger elevator that unifies form and function.

New Frontier Utility Disc Harrows

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

RT 780. RT USt Lifting Capacity Rough Terrain Cranes Datasheet Imperial. Features

Eaton 93PM UPS Where aesthetics meet intelligence.

Data Center Cooling A guide from: Your partners in UPS Monitoring Systems

Machine Room Less (MRL) Elevators. Evolution in elevator design.

MINIMUM PARKING STANDARDS DRIVEWAY WIDTH AND SLOPE TABLES

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

ADA Checklist for Polling Places

UNITED TECHNOLOGIES CARRIER CORPORATION. Remote Monitoring MONITORING YOUR BUILDING 24/7 SO YOU DON T HAVE TO

BUILDING PERMIT SPECIFICATIONS

VOLVO WHEEL LOADERS BLOCK HANDLING

THE MACHINE-ROOM-LESS ELEVATOR. KONE N MonoSpace

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

Professional CAD System

NAGEL ECO 180 FLEXIBLE HONING SYSTEM

Hydraulic Elevators Are Energy Efficient and Future-oriented Facts, arguments and explanations

Lattice crawler cranes

Copyright: Maarten Beerten Maycodesign.nl specifically made for University of Rotterdam.

10' 16' Maximum. Backwall 5' 5'

The Homeowner s Building Application Checklist for Constructing a Residential Sundeck

SWING-REACH TRUCKS 9000 SERIES

City of Richmond Capital Planning and Asset Management

Upgrading the PRS datacentres: space requirement. S. S. Mathur, GM-IT, CRIS

CARL LOAD MANAGEMENT SYSTEM OPEN CYLINDER HYDRAULIC GANTRY SYSTEMS

UBC Technical Guidelines Division Edition CONVEYING EQUIPMENT Page 1 of 1 INDEX. Section

Contents Explanation of the long term permit No rights can be derived from this overview.

PUBLIC VERTICAL PLATFORM LIFT PLANNING GUIDE

d e n v e r a r t m u s e u m

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

INGROUND, ROPED, AND HOLELESS JACK SEAL REPLACEMENT

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Door Schedules and Window Schedules.

EXCAVATOR SAFETY TRAINING

Zoning Most Frequently Asked Questions

Vestibule Case Study. Vestibule Requirement Intent [2003 IECC, 2006 IECC, 2003 IBC, 2006 IBC, , ]

Lower Level (Level L) Exhibit Halls A, B & C

T16. Achieve up to 20% lower cost of ownership with Tennant s quality construction and innovative technologies

IoT Changes Logistics for the OEM Spare Parts Supply Chain

Hitachi Secures Elevator Order from a 5-Star Hotel in India

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

ENERGY EFFICIENCY ENERGY EFFICIENCY: Saving Dollars While Clearing the Air

THE MACHINE-ROOM-LESS ELEVATOR. KONE N MonoSpace

oj microline touch thermostats PRODUCT PROGRAMME intelligent thermostat design in three dimensions Floor Heating ELECTRIC Hvac CONTROLS & POWER

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT SUBMITTAL OF CONVEYANCE INSTALLATION/ALTERATION PLANS

The District Energy Manager and Classroom Heating

Field Services Increase efficiency and manage costs across technical infrastructure.

The smart route to performance.

Transcription:

Machine-roomless holeless hydraulic elevator

Design freedom comes to low-rise buildings. Introducing the HydroFit system: a machine-roomless holeless hydraulic elevator. Otis knows it s not just any building it s your building. We applied the strength of our engineering resources and created the HydroFit system, an innovative hydraulic elevator system that eliminates the need for a machine room and allows all critical components to be contained in the hoistway. The result is a system that frees up valuable floor space and supports your design vision in a way that only Otis can. Otis HydroFit Delivers: Design freedom Minimal jobsite coordination Energy efficiency Proven reliability 2

Machine-roomless technology. Now available in holeless hydraulic systems. The HydroFit elevator is a self-contained system that uses Otis proven holeless hydraulic design. Key components were redesigned to be more compact and able to fit in a standard hydraulic hoistway, eliminating the need for a machine room. HOLELESS HYDRAULIC ELEVATOR OTIS HYDROFIT ELEVATOR CONVENTIONAL SYSTEM Requires a machine room with lighting, HVAC, and fire protection. HYDROFIT SYSTEM No machine room everything fits in the hoistway. 7 4 5 9 Remains the same as a conventional system: Hoistway depth Hoistway width Pit depth Overhead 8 4 5 9 Note: Hoistway dimensions are for a 2500 lb. capacity car. 8 4 5 9 Conventional System: requires dedicated space for the elevator machine room. HydroFit System: machine-roomless means more usable space in your building. 3

design freedom Experience more design freedom with Otis HydroFit. With more square feet in your building, you have the freedom to create spaces that meet your design vision and needs. The HydroFit system allows building owners to increase income with more rentable space. minimal jobsite coordination Save construction time and cost. A machine room is more than just a room. It requires lights, fire protection, and HVAC. HydroFit doesn t require a machine room, saving time and money on the jobsite. To further reduce coordination with numerous trades on the jobsite, hall call buttons are mounted in the door jamb. The industry's shortest lead time. Coordinating a construction project is complex. The HydroFit system has an industry-leading lead time of six weeks, allowing you the flexibility to more accurately plan your project and avoid costly storage and remobilization fees caused by missed targets. Order is placed HydroFit 6 weeks up to 50% less time Industry System 10 to 12 weeks Time to elevator delivery 4

ENERGY EFFICIENCY Energy efficiency: standard on the HydroFit At Otis, we believe that being energy efficient is not optional. The HydroFit system comes standard with features to maximize the efficiency of your elevator. SLEEP MODE EFFICIENT LED LIGHTING Lights and fan are shut down when there s no demand, making lights up to 80% more efficient Seamlessly springs back to life Reduces energy consumption Lasts up to 10 times longer Proven Reliability Industry-leading service that only Otis can provide. Otis optimizes equipment performance throughout each product s lifecycle. Innovative technologies let Otis engineers precisely identify or anticipate possible issues. When our mechanics arrive at customer sites, they are prepared to make repairs quickly and efficiently. REM REMOTE ELEVATOR MONITORING Hundreds of diagnostic points monitored Expert analysis Irregularities proactively corrected Standard on the HydroFit system OMMS OTIS MAINTENANCE MANAGEMENT SYSTEM Predictive and preventative system Fewer service calls Industry-leading uptime 5

Total energy consumption (kwh/yr) 4000 3000 2000 1000 HydroFit System Standard Hydraulic System MAXIMIZED EFFICIENCY The HydroFit system using LED lighting and sleep mode uses less energy when compared to a traditional hydraulic system Otis HydroFit: less space, less coordination, more value. OTIS ELITE SM Otis Elite experts dedicated to your elevator Remote access Real-time status updates Guaranteed 15-minute response time Another breakthrough from Otis: a machineroomless option for hydraulic elevator systems. The HydroFit system is another example of Otis commitment to perfecting elevator technology. Because the HydroFit system is from Otis, you can rest assured that it comes with the reliability and service you ve come to expect. 6

HYDROFIT Specifications E A B F D Travel height maximum 24 9 G Important: To assist in your Maximum stops 4 Speed (ft/min) 100, 125 Hoisting Beam (Not by Otis) C I H J planning, we recommend that you call your Otis representative at the beginning of the project. Plunger Machine Room (optional) L K Dimensions Rated lbs. 2100 2500 3000 3500 Passenger capacity (USA/Canada) 13/12 16/15 20/18 23/21 Car A Interior width 5 8-1 4 6 5-1 2 B Interior depth 1 4 3-9 16 5 0-3 16 5 5-9 16 C Interior height 7-9 D Car door width 3-0 3-6 Hoistway E Width 7-7 2 8-4 F Depth 3 5-9 6-4 6-11 G Rough opening width 4-8 5-2 H Rough opening height 7-10 I Clear opening height 7-0 Maximum rise (with 4 pit depth) 4 @100 ft/min (1 stage) 13-5 @125 ft/min (1 stage) 13-2 @100 ft/min (2 stage) 24-9 @125 ft/min (2 stage) 24-6 J Clear overhead to hoist beam (with 4 pit) @100 ft/min (1 stage) 12-3 @125 ft/min (1 stage) 12-4 @100 ft/min (2 stage) 12-7 @125 ft/min (2 stage) 12-10 K Minimum pit depth 4-0 Machine Room (optional) L Number of elevators in group 111 1 2 Width x depth 5 9 x 7 4 11 6 x 8 6 1. For systems with front and rear openings, add 1 4 to depth dimension. 2. 7 4 for installations that opt to use a machine room. 3. For systems with front and rear openings, add 6-1 4 to 2100, 2500 and 3500 lb, 7-7 8 to 3000 lb. 4. Rise will vary based on weight of car, speed, and pit depth. Please consult your Otis Representative. w w w. o t i s. c o m publication HYD-1201 (1011) colab Otis Elevator Company 2011. All rights reserved.