IP-based Public Address Unit

Similar documents
Phase Modular Finally the benefits of Modular ups are for all

PowerGem Pro Uninterruptible Power Supply

Temperature & Humidity SMS Alert Controller

VM-3000 Series. With new features! Integrated Voice Evacuation System. sound without compromise.

BridgeWay Fixed Base Radio Telecom VoIP Gateway

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

SMS GSM Alarm Messenger

BridgeWay Fixed Base Radio Telecom VoIP Gateway

Interface Adapters PS/2 Interface Adapter 1 pack B21 PS/2 Interface Adapter 8 pack B21 USB Interface Adapter 1 pack B21

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Digital Audio and Data Distribution System

Rack mounted telephone- and leased line modem for industrial applications

MANUAL PC1000R

MPR-Systems. Mini Power Racks 1200 W W

Back-UPS Pro 1300/1500 Installation and Operation

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

PS 29M DUAL CHANNEL BELTPACK IN METAL CASE

EN54-16 Voice Alarm System PRODUCT DATASHEETS

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

Cisco Redundant Power System 2300

AXIS 262+ Network Video Recorder

Current Monitoring Kit QUICK START GUIDE

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Number 1 in efficiency

Current Monitoring Kit

Repeaters and Mimics Data Sheet

Product Information Fire alarm panel 8000 C

Fire alarm system EBL512 G3

EV-1000 Series DVR. Quick Operation Guide. Version 1.0.0

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Permissible ambient temperature Operation Storage, transport

BRIDGEWAY MOBILE VOIP RADIO-INTERCOM GATEWAY

Bristol ControlWave Redundant Control

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Product Information Sheet UH28CS-12kV Hi Pot Tester

SNMP Web Management. User s Manual For SNMP Web Card/Box

SYSTEM DESCRIPTION Termination Boards

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

KACO-monitoring. onlinecomponents.com. Integrated monitoring available. Monitor up to 32 inverters per prolog. Reliable and accurate data

Smarthome SELECT Bluetooth Wireless Stereo Audio Receiver and Amplifier INTRODUCTION

1.44 kw Programmable DC Power Supplies XLN Series

Multi-Range Programmable DC Power Supplies 9115 Series

Uninterruptible Power Supply

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

QuickSpecs. HP IP Console Switch with Virtual Media Overview

TELIKOU Intercom System. MS-500(4+1 channel) Main Station Instruction Manual

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

Product Information Sheet UH36 Hi Pot Tester

TELECOM HF VHF UHF over IP

NetScanner System. Toronto: , Montreal: , Toll Free: ,

TELIKOU Intercom System. TM-200 Main Station. Instruction Manual

Installation and Operation Back-UPS 1250, 1300, 1500

User manual Rev 1.3 Contents

3500/93 System Display

T Zone Weekly Timer

FIREDEX Conventional Fire Panels

Plena Two-zone Call Station. Installation and User Instructions PLE-2CS

Installation Guide. AXIS 2191 Audio Module Sight, Speech and Sound over IP!

connecdim Gateway G1 Ethernet TCP/IP to DALI

I STAR COMPUTER CO., LTD

NEW. EVEN MORE data acquisition and test stand automation

How To Make A Fronius Cl Power Inverter

PCS0100en Persy Control Services B.V. Netherlands

Notice. Reverse engineering and disassembly are prohibited.

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

TI 313 (1.0 EN) d&b Remote network - Integration

Job Aid Pre-Installation Information S8500 Media Server

Clino Call DECTplus. Wireless communication

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

BUSINESS SYSTEMS MONITORING

Features, Benefits, and Operation

ECD 2 High Performance Balanced DAC. 24 Bit /192kHz. Owner's Manual

DCS Data and communication server

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

Modular I/O System Analog and Digital Interface Modules

BridgeWay M400/M800 Radio/Intercom VoIP Gateway System Overview

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

User manual Rev. 1.2 (17/04/2015)

8-Port PoE Network Switch

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Disturbance Recoder SPCR 8C27. Product Guide

3500/22M Transient Data Interface

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Ideal CD player and FM tuner for use with other 301 Reference Series components also supports RDS and USB memory playback

OZW30. Central Unit SYNERGYR

AARC-EVAC Portable Hand Held or Fixed Transmitter with SOS assist - ATX43E25 SAFETY ALERT SYSTEMS

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

ABB central inverters PVS to 1000 kw

NEWTECH PRO KVA ONLINE UNINTERRUPTIBLE POWER SUPPLY USER MANUAL

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

HDO700 P FIBRE OPTIC TRANSMITTER

Section TELEPHONE AUTOMATIC DIALER SYSTEM

Indoor / Outdoor Antenna

Thyristor-controlled power supplies and battery chargers

Transcription:

IP-based Public Address Unit NPA Series Flexible and modular design with up to 600-W output power Up to 4 simultaneous and independent amplifier channels Up to 8 selectively addressable speaker circuits Maximum reliability due to redundancy and integrated speaker monitoring Easy integration into IP networks (IEEE 802.3) THE ENGINEERS OF COMMUNICATION

NPA Series Multi-channel IP-based PA Unit Intelligent Public Address Solutions The multi-channel IP PA unit of the NPA series is INDUSTRONIC's top-of-the-line product for intelligent PA solutions. It ensures excellent speech intelligibility and seamlessly interfaces with the INTRON-D plus communication and public address system via an Ethernet/IP network. The IP PA unit is ideal for centralized or decentralized operation. Up to 8 selectively addressable speaker circuits enable the simultaneous broadcasting of voice announcements, tone signals, or background music to different speaker zones. User-friendly maintenance To facilitate maintenance work, the IP PA unit is equipped with 2 keys and a mini USB port at the front of the device which can be easily accessed by service staff. Clear user interface and easy operation The display shows important information, e.g. the status of the speaker circuits (active/inactive). The keys allow you to navigate through the menu with ease. 2

Numerous terminals and interfaces Different inputs and outputs on the back of the device enable you to connect additional equipment (e.g. emergency microphone). Integrated web interface The integrated web interface facilitates commissioning and maintenance. It can be locally or remotely accessed via a standard web browser. Clear signaling The 3 status LEDs provide accurate information about the current status of the device during commissioning or normal operation. They let you know if the device is switched on, if it is ready for operation and if there are any faults. Modular design Different amplifier modules and power supply units enable fast and flexible implementation of your specific requirements. Individual solutions can be realized by simply inserting suitable modules and units on the back of the device. 3

Maximum Flexibility Modular Design The IP PA unit offers a high degree of flexibility thanks to the different amplifier modules and power supply units which can be combined to meet your specific public address needs. Flexible expansion stages The basic configuration provides 1 digital amplifier channel, up to 4 monitored speaker circuits, and a maximum output power of 300 Watts. The maximum configuration provides 4 simultaneously usable amplifier channels, 8 speaker circuits, and a maximum output power of 600 Watts. Mandatory call output A mandatory call output can be additionally assigned to each amplifier channel. Then, a connected mandatory call relay always applies for all speaker circuits of the respective channel, even when they are individually controlled. Easy Expansion Several IP PA units can be implemented for even more extensive solutions. Special types are available upon request. Basic configuration 1 x digital amplifier channel Up to 4 monitored speaker circuits 300-W output power Maximum configuration Up to 4 digital amplifier channels Up to 8 monitored speaker circuits Up to 600-W output power Expandable now and in future Individual combinations The amplifier modules are available in two different versions: 1 x 300 W and 2 x 150 W 1 x 300 W 1 x amplifier channel Up to 4 speaker circuits Slide-in modules and units Individual solutions can be realized by simply inserting suitable modules or units on the back of the device. 2 x 150 W 2 amplifier channels Up to 4 speaker circuits 4

Adaptation to Mains Voltages Worldwide There exists a variety of mains voltages worldwide. The power supply concept of the IP PA unit ensures reliable adaptation to different conditions anywhere in the world. AC and DC voltage A special feature of the device is that it provides 2 slots by default which can be equipped with AC power supply units (100 VAC to 276 VAC). Usually, one power supply unit can power a fully equipped IP PA unit during 230-V operation. Furthermore, there is 1 DC input available (42 VDC to 72 VDC). 100 VAC to 276 VAC 42 VDC to 72 VDC Wide-range input for worldwide use Redundant power supply If required, power supply can also be installed redundantly. To do this, the device is equipped with 2 AC power supply units on the back. The redundant power supply unit is operated in hot-standby mode. For even more protection, you can install an additional DC emergency power supply. AC PS 1 The right power supply for each application With 2 independent AC inputs and 1 DC input all local power supply requirements can be met - anywhere in the world. Each power supply unit has its own mains connection so that it can also be powered by different supply mains. AC PS 2 (optional for redundancy) DC input 5

Maximum Availability Redundant Configuration The permanent availability of the devices used is crucial especially when initiating alarms or voice announcements in emergency situations. The intelligent backup control of the NPA devices enables component redundancy for the amplifier modules and the power supply unit - all in one device. Redundant amplifier modules and power supply To backup an amplifier module with a second one, you simply insert an identical amplifier module into the second slot provided. For redundant power supply, both AC inputs are used. If the main power supply unit fails, there is an automatic switchover to the redundant power supply unit to ensure uninterrupted operation. Power supply units can be easily and quickly replaced during normal operation thanks to hotswap capability. Since you don't have to isolate the device from the power supply, replacement can be done without interruption of operation. To provide additional protection, you can connect an emergency power supply (e.g. battery) to compensate for mains interferences. Redundant amplifier modules and power supply units Complete N+1 redundancy Different redundancy solutions ensure uninterrupted operation Immediate switchover to redundant components Hot-swap capability N+1 redundancy Completely redundant IP PA units which are configured in N+1 redundancy mode provide 100 % power without interruption. For N+1 (N = 1 to 4), there is always one backup device available to take over the complete functions in case of failure. There is an automatic switchover of all inputs and outputs. Individual solutions Every project has individual requirements. Together we will find the redundancy solution that best fits your needs. 2 power supply units N+1 component redundancy 2 amplifier modules Permanent availability A redundant configuration ensures maximum availability. With the IP PA units from INDUSTRONIC different redundancy concepts can be implemented. 6

Reliable Public Address Continuous Monitoring Continuous monitoring ensures the proper operation of the IP PA unit - at any time during alarms, announcements, or the playback of background music. Integrated monitoring The IP PA unit monitors various states. The monitoring function is fully integrated into the device. This means less effort and expense for wiring and no external monitoring cards are required. The IP PA unit monitors itself for: Voltage loss Short circuit Overload Excess temperature Speaker monitoring You can optionally extend the monitoring function of the IP PA unit by speaker monitoring. This functional extension enables you to continuously monitor individual speaker circuits for short circuit, ground leakage, line interruptions as well as impedance changes. Make all necessary settings via the web interface - from performing reference measurements through to defining measuring cycles. Completely monitored public address solution All monitoring functions are fully integrated into the device Functional extension providing speaker monitoring can optionally be activated Web interface enables convenient indication of all states including download option Indicators and Signaling Potential faults are indicated at the front panel as well as on the integrated web interface of the device. Furthermore, any faults are logged on the web interface of the corresponding central exchange unit. This way, immediate measures can be taken to eliminate faults. Fully integrated monitoring Continuous monitoring of the proper operation of the device and all connected speaker circuits is crucial for a reliable public address solution. For this reason, all monitoring functions are fully integrated into the device. 7

Centralized or Decentralized Installation Customized Solutions The IP PA unit seamlessly interfaces with INDUSTRONIC's INTRON-D plus public address and communication system via an Ethernet/IP network and offers centralized or decentralized operation to suit your needs. Centralized installation Centralized installation means that the IP PA unit and the central exchange unit are installed in the same location, e.g. inside a central exchange cabinet. Decentralized installation Decentralized installation means that the device is installed in a remote location other than the central exchange unit, but is still part of the same network. Usually, the device is installed close to the speakers to be connected. This ensures shorter cable distances and reduces cabling costs. The device is ideal for indoor installation in dry rooms, e.g. in existing server rooms or offices. Centralized or decentralized installation depending on your requirements Various installation locations possible (e.g. inside the central exchange cabinet or in offices) Installation anywhere on the LAN In principle, the IP PA unit can be implemented anywhere on the LAN. This way, the device can be treated as an independent, remotely installed IP amplifier with fully integrated zone selection, optional speaker monitoring, and redundant power supply. IP Decentralized installation from central exchange unit For decentralized installation, the compact IP PA units are distributed throughout the plant and are installed near the speakers in a space-saving manner - exactly where they are needed. Short cable distances to speakers reduce cabling costs as cables with a smaller conductor cross section can be used. 8

Easy Expandability Highly Versatile Inputs, Outputs, and Interfaces Numerous inputs, outputs as well as interfaces allow you to individually expand the IP PA unit and use the full range of features to meet even complex requirements. PTT input and AF input A PTT input on the back of the device enables, for example, the connection of an emergency microphone which ensures the propagation of voice announcements at any time. At another separately located AF input you can, for example, connect a CD player for playing music. Open-collector outputs 4 open-collector outputs enable the connection of mandatory call relays or flashing warning beacons. A mandatory call relay is used to propagate acoustic signals or live announcements with maximum volume, no matter what volume is set at the speaker - even if the volume control is set to zero. 1 PTT input including AF input 1 separate analog AF input 4 open-collector outputs RS485 interface 1 fault message output Fault message output The proper operation of the IP PA unit can be externally indicated via fault message output (e.g. at an intercom station). RS485 interface The IP PA unit can be expanded by an I/O module via RS485 interface to have additional inputs and outputs available. This allows for even more comprehensive control options at your fingertips. Flashing warning beacon Flashing warning beacons can be additionally used to visually alert people to an announcement. Emergency microphone The emergency microphone ensures uninterrupted operation even when the central exchange unit or the network fails. Live announcements initiated via emergency microphone always have the highest priority and interrupt other less urgent announcements or background music. 9

Convenient Management and Visualization Integrated Web Interface With the integrated web interface you will never lose the big picture. You will have an overview of all relevant device information - clearly structured and displayed. There are several features available facilitating commissioning and maintenance. Permanent availability The web interface of the IP PA unit operates independently from the central exchange unit. It is also available if the central exchange unit is out of service or not yet connected to the IP PA unit. Local or remote access The web interface can be locally accessed via PC/notebook using the USB interface at the front panel of the device or remotely via the network. This way, you can use a standard web browser and access the web interface from any location within the network. Among other things, you will be able to: Define network settings Configure speaker monitoring Display and download fault reports Analyze and evaluate status information Intuitive operation Clear structure Accessible from any location within the network Always available Configuration with the Config Manager With the Config Manager, INDUSTRONIC's feature-packed configuration software, you can configure the IP PA unit according to your needs. All functions are set using the intuitive user interface and are then uploaded to the central exchange unit. As soon as a network connection is established between the central exchange unit and the IP PA unit, the configuration is activated. Intuitive web interface The clear and user-friendly structure of the individual menus enables intuitive navigation. After commissioning you can create an account with user-defined functions. 10

Series Overview Chart Type 300 NPA 11 300 NPA 21 600 NPA 21 600 NPA 41 Amplifier slot 1 1 x 300 W 2 x 150 W 1 x 300 W 2 x 150 W Amplifier slot 2 - - 1 x 300 W 2 x 150 W Total power 300 W 300 W 600 W 600 W Amplifier channels 1 2 2 4 Speaker circuits 4 4 8 8 Type number 302-141-100 302-141-200 302-141-300 302-141-500 Other types are available upon request. Functional extension Description Type number Speaker circuit monitoring Monitoring of connected speaker circuits for short circuit, ground 100-740-900 leakage, line interruption as well as impedance changes Technical Data Electrical data AC supply voltage 100 VAC to 276 VAC DC supply voltage 42 VDC to 72 VDC Frequency response 150 Hz to 16 khz (+/-3 db) Efficiency > 80 % Power frequency 47 Hz to 63 Hz Power factor correction 0.95 (PFC) Control voltage output 48 V / 0.5 A Mechanical data Design Height x width x depth Display Weight 19" rack mounting 132 mm x 430 mm x approx. 330 mm (5.2" x 16.9" x approx. 13") 128 x 64 pixels Max. 13.5 kg (max. 29.8 lbs) (depending on device type) Environmental requirements and standards Ambient temperature -5 C to +50 C (+23 F to +122 F) during operation Relative humidity Max. 95 % (non-condensing) EMC IEC/EN 61000-6-2 IEC/EN 61000-6-4 Connections and interfaces 2 x analog AF inputs RS485 interface for expansions 1 x fault message output 2 x Ethernet 1 x control line input 4 x mandatory call outputs 1 x mini-usb service port 1 x control voltage output 48 VDC / 0.5 A 2 x mains voltage inputs 1 x DC voltage input 11

INDUSTRONIC Industrie-Electronic GmbH & Co. KG Carl-Jacob-Kolb-Weg 1 97877 Wertheim / Germany Phone: +49 9342 871-0 Fax: +49 9342 871-565 info@industronic.de www.industronic.de Copyright 2015 INDUSTRONIC Subject to technical modifi cations Doc. no. PDT-330-001-390 Rev. 1 EN 19.02.2015 THE ENGINEERS OF COMMUNICATION