Vickers Pressure Relief Valve - Direct Acting

Similar documents
Pressure reducing valve, direct operated, Type ZDR 6 D

Char-Lynn Disc Valve Motors. Parts Information Compact Series

Char-Lynn Hydraulic Motors. Repair Information. W Series Geroler Motors 002, 003. April, 1999

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

Pressure relief valves Size 6

Safety for Hydraulics Leak free double check valve, pilot operated, series DERV Cartridge type, two stage

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

2-way flow control valve Type 2FRM 6

Open center control block in monoblock design MO-40

2/2 and 3/2 Way Size 6 Seat Valves

KDG3V-5/7/8, 10 Series

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Manapak Sandwich Valves Series CM, CPOM, FM, PRDM, PRM, RM

Check Valves Valve locator

RA / Functional description 1/10. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Pressure Relief Valves for Pipe Mounting

3/2 Solenoid Cartridge Valve, Size 6

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Oil Pressure Regulating Valve

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Line rupture protection valves type LB

Chapter 6: Check Valves

3/2- and 2/2-way cartridge valve type BVE

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

PRESSURE RELIEF VALVES VALVOLE DI MASSIMA PRESSIONE


SystemStak. SystemStak Valves. Vickers

Hydraulic Flow Control Valves

Fixed displacement vane pumps

Round Housing with Side Ports

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

PVH131/141 Variable Displacement Piston Pump - 11 Design

Dual Path Mobile Pump

Electro-hydraulic pressure switches type DG

*Rated to 207 Bar/3000 PSI with Aluminum Body. Denotes New Winner s Circle Product Line. Catalog HY /US

Directional Controls

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

Variable Displacement Pump AA10VSO

Chapter 5: Flow Valves

*Rated to 207 Bar/3000 PSI with Aluminum Body. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

Pressure Relief Valves SPV, SPVF

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

005 SERIES MODULAR VALVES. Pub. EC General Information Up to 25 MPa (3630 PSI), 10 L /m in (2.6 U.S.GPM) Modular Valve Type

Pressure Relief. Pressure Relief Valves. Vickers

Vickers. Overhaul Manual. Relief Valves. Balanced Piston Relief Valves. CG/CS/CS5-03/06/10 Series CT/CT5/CG5-06/10 Series

SOLENOID VALVES 3-4 WAY

Proportional Pressure Relief Valves

Unit 24: Applications of Pneumatics and Hydraulics

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

2-way flow control valve with sliding throttle type SB and SQ

Vickers. Piston Pumps

Series PVP Variable Volume Piston Pumps

Series TMM Axial Piston Motor. Technical Information

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

1.Booklet. Hydraulic Motors. General Purpose MotorsR Series

Valve systems Base plates, according to standard ISO Brochure

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

PVM Piston Pumps Service Manual

Proportional Pressure Reducing Valves

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

15/40/80CN Series Medium Pressure Filters

3 Port Solenoid Valve

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

Directional Control Valves

The SF2 series are designed for reservoir side-wall mounting applications, suitable for flow rates to 850 l/min and filtration from 25 to 250 micron.

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Vickers Vane Pumps Single and Double Vane Pumps. Model Series V10, V20, V2010, and V2020 for Industrial Equipment

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

PRE3G /212 ED PILOT OPERATED PRESSURE CONTROL VALVE WITH PROPORTIONAL CONTROL AND INTEGRATED ELECTRONICS. Q max 40 l/min SERIES 12

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

Denotes New Winner s Circle Product Line. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

3 Port Solenoid Valve

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Axial Piston Variable Pump KVA

4/2-Way Pneumatic Solenoid Valve

IMPORTANT DOCUMENTATION DO NOT DISCARD!

PVQ 40-B2/M2 * *** - ** * * - 10 C** *** *** * - 10/11/12/20 PVQ 45-B2/M2 * *** - ** * * - 10 C**

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

DATA PD SV13.., SV14.. Levelling Valves. Product. Function. Technical Features. Range Overview

Pneumatic. PXC Limit Switches. Authorised Distributor TTS Valve Technologies Sdn Bhd

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

Internal gear pump PGF Series 2X and 3X

Directional seated valves type VP 1

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

Over-center valves type LHK with hydraulic release

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

The cylinder head bolts tightening stages have been updated as listed in Table 1.

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Transcription:

Vickers ressure Relief Valve - Direct Acting DARV 50-350 L/min Manifold Mounting In-line Mounting Sub-plate Mounting

able of Contents General Description... 2 Model Code... 3 echnical Data... 4 Flow Curves... 4 Unit Dimensions... 5 Dimensions for In-Line Mounting... 6 Dimensions for Subplate Mounting... 7 Released art Numbers... 8 EAON Vickers ressure Relief Valve-Direct Operated V-VLRE-MC003-E May 2009 1

General Description Features: For manifold mounting cartridge valve For In-line threaded mounting For manifold mounting hree pressure adjustment elements, optional: Wrench adjustable grub screw with protective cap Rotary knob/hand lever Lockable rotary knob General Eaton s Vickers DARV pressure relief valves are direct operated poppet valves. hey are used to limit the pressure in a hydraulic system. he valves mainly consist of sleeve (1), spring (2), poppet with damping spool (3) pressure 25 to 400 bar) and adjustment element (5). he setting of the system pressure is variable via the adjustment element (5). he spring (2) pushes the poppet (3) onto the seat. he line is connected to the system pressure. he system pressure is applied to the poppet area. If the pressure in line exceeds the value set at the spring (2), the poppet (3) opens against the spring (2). Now pressure fluid flows from line into line. he stroke of the poppet (3) is limited by a pin (6). In order to maintain good pressure control over the entire pressure range it is split into seven pressure ranges. Hydraulics Symbol 1 3 4 5 2 6 ype DARV...K... 1X/, direct acting pressure relief valve 2 EAON Vickers ressure Relief Valve-Direct Operated V-VLRE-MC003-E May 2009

Series DARV Model Code (F3) DARV W 6 K 10/ 25 (B) 1 2 3 4 5 6 7 8 1 Seal Options Blank Nitrile, for Mineral oil Anti-wear hydraulic oil (class L-HM) Invert emulsion (class L-HFB) Water glycol (class L-HFC) F3 Fluorocarbon seals, for hosphate Ester (class L_HFD) 2 Direct acting relief valve 3 Adjustment W - Wrench and cover H - Knob K - Lockable Knob (Size 6, 8 and 10 only) 4 Size 6 - size 6 8 - size 8 10 - size 10 15 - size 15 20 - size 20 25 - size 25 30 - size 30 5 Mounting Style K Cartridge valve (6,10,20,30 only) G In-Line mounting (all sizes) Subplate mounting (6,10,20,30 only) 6 Design Number 10 8 ressure Range 25 25 bar 50 50 bar 100 100 bar 200 200 bar 315 315 bar 400 400 bar (size 6 to 20 only) 9 hread type of In-Line mounted valve (G option) B BS thread F Metric thread EAON Vickers ressure Relief Valve-Direct Operated V-VLRE-MC003-E May 2009 3

echnical Data HYDRAULIC ECHNICAL DAA Max. Operating ressure (Bar) Max. Flow Rating (L/min) Fluid temperature range ( O C) Fluid Viscosity range (mm 2 /s) 10 to 800 Fluid Cleanliness Level ISO 19/17/14 Size 6 8, 10 15, 20 25, 30 ort 400 400 400 315 ort 315 315 315 315 Size 6 8, 10 15, 20 25, 30 (L/min) 50 120 250 350-30 to + 80 (with Nitrile seals) -20 to + 80 (with Fluorocarbon seals) Flow Curves (measured at v = 41mm 2 /s and t = 50 O C) Size 6 Size 8 and 10 400 600 Operating ressure (bar) 300 200 100 50 Operating ressure (bar) 500 400 300 200 100 50 0 10 20 30 40 50 60 0 20 40 60 80 100 120 Flow Q p (L/min) Flow Q p (L/min) Minimal Control ressure Minimal Control ressure Size 15 and 20 Size 25 and 30 400 300 Operating ressure (bar) 300 200 100 50 Operating ressure (bar) 200 100 50 0 100 200 250 Flow Q p (L/min) Minimal Control ressure 0 100 200 300 Flow Q p (L/min) Minimal Control ressure 4 EAON Vickers ressure Relief Valve-Direct Operated V-VLRE-MC003-E May 2009

DARV Series Dimensions mm For Manifold Mounting K Style Mounting Ø2.5 5 4 1 AF19 AF30 AF6 AF 6 0,008 / t 20 0,008 / t 20 0,02 A ØD4 8 0,1 a ØD1 45 o L1 ØD2 ØD3 ØD5 ØD6 A Ø60 2 4 AF19 AF30 AF 0,05 A A L4 L5 L6 L7 ØD7 L8 L9 L10 0.5 X 45 O Rz 16 9 11 L2 L3 11 AF30 3 7 9 87 65 11 30 L2 AF 1. Wrench adjustable grub screw and protective cap, W option 2. Rotary knob (up to size 20) and hand wheel (size 30), H option 3. Lockable rotary knob up to size10 (sizes 20 to 100 bar), K option 4. Locknut 5. rotective cap 6. ressure rating (stamped on) 7. Reference mark (osition may be set by moving it axially to engage with the AF30 Hex) 8. port position optional about circumference or end 9. port position optional about circumference Size ØD1 ØD2 ØD3 ØD4 ØD5 ØD6 ØD7 a L1 L2 L3 6 34 M28 x 1.5 25 H9 +0.152 6 15.00 24.90-0.200 6 15 o 72 83 64.50 10 38 M35 x 1.5 32 H9 +0.162 10 18.50 31.90-0.200 10 15 o 68 79 79.00 20 48 M45 x 1.5 40 H9 +0.162 20 24.00 39.90-0.200 20 20 o 65 77 106.00 30 63 M60 x 2.0 55 H9 +0.174 30 38.75 54.90-0.200 30 20 o 83 - - 131.00 Size L4 L5 L6 L7 L8 L9 L10 AF Weight (kg) 6 15 19 30 35 45 56.50 65 32 approx. 0.4 10 18 23 35 41 52 67.50 80 36 approx. 0.5 20 21 27 45 54 70 91.50 110 46 approx. 1.0 30 23 29 45 60 84 113.50 140 60 approx. 2.2 ightening torques value in Nm(ft - lb) up to 200 bar up to 400 bar 50 (37) 80 (59) 100 (74) 150 (111) 150 (111) 300 (221) 350 (258) 500 (370) EAON Vickers ressure Relief Valve-Direct Operated V-VLRE-MC003-E May 2009 5

DARV Series Dimensions mm For In-Line Mounting G Style Mounting D1 D2 B2 2 B1 () H1 H2 L3 L4 1 D4, Depth 1 D3 L5 L7 L6 3 () B1 B2 L8 4 1 Adjustment for pressure setting 2 Optional port position 3 Nameplate 4 Valve mounting holes Size ØD1 D2 (Metric) D2 (BS) 6 25 M14 x 1.5 G 1/4 (8)10 (28)34 (M18 x 1.5) M22 x 1.5 (G 3/8 ) G 1/2 (15)20 (42)47 (M27 x 2) M33 x 2 (G 3/4 ) G 1 (25)30 (56)61 (M42 x 2) M48 x 2 (G 1-1/4 ) G 1-1/2 Size ØD3 D4 B1 B2 H1 H2 L3 L4 L5 L6 L7 L8 1 Weight (kg) 6 6.60 M6 45 60 25 40 80 4.00 15 55 40 20 10 approx. 1.5 (8)10 9.00 M8 60 80 40 60 100 4.00 20 70 49 21 20 approx. 3.7 (15)20 9.00 M8 70 100 50 70 135 5.50 20 100 65 34 20 approx. 6.4 (25)30 11.00 M10 100 130 60 90 180 5.50 25 130 85 35 25 approx. 13.9 6 EAON Vickers ressure Relief Valve-Direct Operated V-VLRE-MC003-E May 2009

DARV Series Dimensions mm For Subplate Mounting Style Mounting B1 () H2 L3 L4 2 1 ØD3 L5 L6 4 3 1 Adjustment screw for pressure setting and protective cap internal hexagon (up to size 20) external hexagon (sizes 25,30) 2 Optional port (e.g. for presuure gauage) 3 Name plate 4 Valve mounting holes () B1 B2 Mounting bolt must be to SAE grade 8, DIN 912-10.9 or ISO 898 class 12.9 Mounting Size L9 L10 Bolt orque L9 6 20 40 M6x 50 14 Nm 10 21 45 M8x 70 34 Nm 20 34 65 M8x90 34 Nm 30 35 85 M10x 110 68 Nm L10 Other dimensions, see In-Line mounting type. EAON Vickers ressure Relief Valve-Direct Operated V-VLRE-MC003-E May 2009 7

Released art Numbers Assembly Number Model Code DARV-W-6-G-10/200B 02-413460 DARV-W-6-K-10/100 02-413461 DARV-W-6-K-10/200 02-413462 DARV-W-6-K-10/315 02-413463 DARV-W-6-K-10/400 02-413464 DARV-W-6--10/10 02-413465 DARV-W-6--10/200 02-413466 DARV-W-6--10/315 02-413467 F3-DARV-W-6--10/315 02-413468 DARV-W-10-G-10/100B 02-413469 F3-DARV-W-10-G-10/100B 02-413470 DARV-W-10-G-10/200B 02-413471 DARV-W-10-G-10/315B 02-413472 DARV-W-10-K-10/100 02-413473 DARV-W-10-K-10/200 02-413474 DARV-W-10-K-10/315 02-413475 DARV-W-10-K-10/400 02-413476 DARV-W-10--10/200 02-413477 F3-DARV-W-10--10/200 02-413488 DARV-W-10--10/315 02-413479 DARV-W-20-G-10/200B 02-413512 DARV-W-20-G-10/315B 02-413513 DARV-W-20-K-10/100 02-413514 DARV-W-20-K-10/200 02-413515 DARV-W-20-K-10/315 02-413516 DARV-W-20-K-10/400 02-413517 DARV-W-20--10/100 02-413518 DARV-W-20--10/200 02-413519 F3-DARV-W-20--10/200 02-413520 DARV-W-20--10/315 02-413521 F3-DARV-W-20--10/315 02-413522 DARV-W-20--10/400 02-413523 DARV-W-25-G-10/100B 02-413524 DARV-W-25-G-10/200B 02-413525 DARV-W-25-G-10/315B 02-413526 DARV-W-30-G-10/200B 02-413527 DARV-W-30-K-10/200 02-413528 DARV-W-30-K-10/315 02-413529 DARV-W-30--10/200 02-413530 F3-DARV-W-30--10/200 02-413531 DARV-W-30--10/315 02-413532 * Bold items are preferred products 8 EAON Vickers ressure Relief Valve-Direct Operated V-VLRE-MC003-E May 2009

Eaton Hydraulics Group USA 14615 Lone Oak Road Eden rairie, MN 55344 USA el: 952-937-9800 Fax: 952-294-7722 www.eaton.com/hydraulics Eaton Hydraulics Group Europe Route de la Longeraie 7 1110 Morges Switzerland el: +41 (0) 21 811 4600 Fax: +41 (0) 21 811 4601 Eaton Hydraulic Group Asia acific 11th Floor Hong Kong New World ower 300 Huaihai Zhong Road Shanghai 200021 China el: 86-21-6387-9988 Fax: 86-21-6335-3912 2009 Eaton Corporation All Rights Reserved rinted in USA Document No. V-VLRE-MC003-E May 2009