inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Similar documents
Acoustic performance of dwellings and specifics for lightweight constructions Professor Eddy Gerretsen

Acoustical proprieties of light brick walls and its effects on flanking transmission

Controlling the Transmission of Impact Sound through Floors

Lightweight Partition Design for Residential and Commercial Buildings

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

VIPAC ENGINEERS & SCIENTISTS

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

Leeds Metropolitan University - Design and Build of new Acoustic Laboratory Suite

Tools for building acoustics design and experimental performances

Rockwool Flexi Insulation Application Guide

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

FACTORS AFFECTING ENERGY CONSUMPTION OF BUILDINGS

BNAM 2008 BERGEN BYBANE NOISE REDUCTION BY TRACK DESIGN. Reykjavik, august Arild Brekke, Brekke & Strand akustikk as, Norway

Investigation of sound insulation for a Supply Air Window field measurements and occupant response

Module 3.7. Thermal bridging

STANDARD DEVIATIONS IN FIELD MEASUREMENTS OF IMPACT SOUND INSULATION. Mikko Kylliäinen

CASE STUDY. Sarakasi Theatre Nairobi, Kenya Room Acoustical Measurements and Modelling. Africa Room Acoustics DIRAC and ODEON

Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University

An Experimental Study of the Sound Insulation Performance and Sound Defect Using Sound Intensity According to the Composition of Balcony Windows

Contents BB93 Acoustic Design for Schools

The Role of Acoustics in Curtain Wall Design:

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Color logos Reverse logos Acoustics Black only logos

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

Composite Panel Firewall Systems

EVERYTHING YOU WANTED TO KNOW ABOUT SOUND BUT WERE AFRAID TO HEAR.

ROOM ACOUSTICS DESIGN. Room Acoustics Design Intent: Appropriate Articulation

Ecophon Focus A. System range. Size, mm. XL 2000x600. XL 1800x600. XL 2400x600 T15 T24 Thickness (THK) Inst. Diagr. 1200x x x600

Metsä Wood. Jussi Björman. R&D Engineer

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Test Report. Nr dated Sound Absorption Coefficient in the Reverberation Room. Lammengatan 2 SE Lammhult Sweden

Post-insulation of cellar ceiling and cellar walls

THE ACOUSTIC DESIGN OF THE NEW DRAMA HOUSE FOR THE ROYAL THEATRE IN COPENHAGEN

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

sound reduction systems for commercial, educational and industrial environments

Acoustical Design of a Conference Hall

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

Acoustic design with wall acoustic solutions

CHAPTER 4 ACOUSTIC DESIGN OF LIGHTWEIGHT TIMBER FRAME CONSTRUCTIONS

Evaluating Field Measurements of Impact Sound. Klas G. Hagberg. Reprinted from JOURNAL OF BUILDING ACOUSTICS. Volume 17 Number

Vibration Isolation in Data Centers

How To Certify The Scottsdale Construction System

Retrofit structural insulated panels (SIPs) increase sound transmission loss of existing single family houses impacted by highway noise

Ecophon Focus Ds. System range. XL 1800x600. Size, mm. XL 2400x600 T24 Thickness (THK) XL 2000x x x x600 M206, M208, M238

- 1 - Element Type. 9 mm gypsum board, 50 mm mineral wool (glued) 9 mm gypsum board, 50 mm mineral wool (on wooden studs, at 300 mm centres)

Understanding BS EN 771-3: Aggregate concrete masonry units

Best Practice in Best Pra ctice in teel constr uction - onstr industrial B uildings esidential Buildings 01 Introduction 02 Key Design Factors

Airborne Sound Insulation

If stepping is required, step at 180mm as seen in this picture.

Office acoustics. How to effectively design the room acoustics of offices. AN INFORMATION BROCHURE OF

Gypsum Board Systems Manual

Relationship between Sound Pressure and Sound Power Levels

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: TREX COMPANY, LLC. Series/Model: Trex Seclusion

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

A COMPUTATIONAL METHOD FOR ANALYSIS AND DESIGN OF ACOUSTIC ABSORBERS AND LOW FREQUENCY TRANSMISSION LOSS

Mass Loaded Vinyl A review of the performance and cost in acoustical applications

TOP 10 NOISE CONTROL TECHNIQUES

Mineral fibreglass insulation

SOUND INSULATION FOR GLAZED DOORS AND STANDARD DOORS

Wardle Storeys. Reducing Rain Noise on Profiled Metal Roofing Systems Using DEDPAN DS2020 RDV

Acoustic Design Practices for Sustainable Buildings

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

SPEECH INTELLIGIBILITY and Fire Alarm Voice Communication Systems

REGGAE 30.3x34 cm./11.9"x13.4" D923. Natural Product that might suffer colour variations 1. PROPER PREPARATION OF SURFACE

ProRox Slabs (formerly known as RW slabs)

Annex of the certificate (Page 1/6) Accreditation Scope

Characterization of acoustics in open offices - four case studies

Energy Company Obligation (ECO): Technical Monitoring Questions

Fire & Soundproofing Insulation. Roxul SAFE N SOUND. Fire and Soundproofing Insulation for Interior Partition Walls and Floors.

ISO Types 1-6: Construction Code Descriptions

ACOUSTIC DESIGN - ROOMS FOR SPEECH

ROUND ROBIN ON UNCERTAINTY IN SOUND INSULATION MEASUREMENTS.

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

Colorcoat Technical Paper Acoustic performance of pre-finished steel cladding systems

VIRTUAL SPACE 4D PROJECT: THE ROOM ACOUSTICAL TOOL. J. Keränen, P. Larm, V. Hongisto

Acoustics factsheet Requirements for new homes and how NHBC can help

Welcome Contents Back 1

Sports Buildings: budget costs for the Flood Relief Fund

Building Systems by Stora Enso. Residential multi-storey buildings

The Acoustical Properties of Wool Carpet

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

OWAplan1. The seamless acoustic ceiling. Pure acoustics. Pure design.

Federation of European Heating, Ventilation and Air-conditioning Associations

THE ACOUSTICS OF THE "NUOVO TEATRO COMUNALE" IN CAGLIARI

Light Steel Modular Construction

High performance thermal insulation materials

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

Case Studies of Successful Code for Sustainable Homes Projects

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

Wisconsin Building Products Evaluation

Acoustical Design Guidelines for HVAC Systems in Schools

CHAPTER 2 QUANTITY TAKE-OFF

Improving thermal insulation of concrete sandwich panel buildings

FiberAcoustic. Second-to-none noise absorbing performance.

Re: Wildwood, 2-6 High Street, Kingston, KT1 1EY - Proposed Restaurant - External Plant Noise Assessment - Revised

Transcription:

Copyright SFA - InterNoise 2000 1 inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering 27-30 August 2000, Nice, FRANCE I-INCE Classification: 5.1 DESIGN OF DANISH BUILDINGS WITH HIGH SOUND INSULATION D.B. Pedersen DELTA Acoustics & Vibration, Kongsvang Allé 33, DK-8000, Aarhus C, Denmark Tel.: +45 8611 4922 / Fax: +45 8611 4377 / Email: dbp@delta.dk Keywords: SOUND INSULATION, BUILDING CONSTRUCTIONS, DESIGN ABSTRACT Danish building constructions with high sound insulation are described. The constructions are used in academies of music or dwellings with airborne sound insulation around 60 db or higher. R w -values of 85-90 db are obtained with a combination of heavy building elements, floating floors and linings. At 50 Hz R can be 50-55 db. Values for the measured sound insulation in-situ are compared with predicted values using the new European standard EN 12354-1, and the agreement is satisfactory. Differences between heavy and lightweight constructions are demonstrated from a considerable number of in-situ measurements. For both airborne and impact sound insulation it is important to take low frequencies into account when the acoustic quality of lightweight constructions is evaluated. 1 - INTRODUCTION The acoustic requirements to building constructions are increasing in several countries. This paper presents measurement results from Danish dwellings with R w values around 60 db and from academies of music where the required sound insulation is even higher. Examples of building constructions are described, and it is demonstrated that the sound insulation can be predicted with the European standard EN 12354-1 [1] with satisfactory accuracy, provided that all necessary input data for floating floors, linings etc. are available. Because of the mass-spring-mass resonance the sound insulation is often poor in the low frequency range for lightweight double constructions. The same tendency is expected when for example linings are used. Therefore, the frequency range below 100 Hz is considered in this paper especially for combinations of heavy constructions with additional layers and for lightweight double constructions. 2 - DWELLINGS WITH CONCRETE FLOORS AND LIGHTWEIGHT WALLS In case of lightweight internal walls and large floor slabs between load-bearing walls or columns, the sound transmission is determined by the vibrations of the total floor area [2]. Since the vibration energy of the separating floor between two rooms is spread to a larger floor area, the sound insulation vertically is higher than for the same slab with heavy internal walls. The sound insulation is also increased because of a small amount of flanking transmission via internal lightweight double walls. In Danish buildings R w -values within the range 59-64 db have been obtained for 160-220 mm massive concrete floors with wooden floors on joists on soft boards. The cavity depths under the wooden floors are 80-100 mm. In order to obtain the mentioned R w -values, the cavities normally have to be provided with a 50 mm thick layer of mineral wool. Figure 1 shows measured and calculated sound insulation for a system of 160 mm concrete floors with wooden floors, supported by 160 mm concrete inner leaves at the facades and concrete columns inside the building. Internal walls are double plaster board walls. The measured R w -values are 61 db and 62 db respectively, and reference curves corresponding to these values are shown in the figure. The calculated values for the sound insulation are predicted with the European standard EN 12354-1. Input data from the informative annexes of this standard are used with the following modifications [3]: The radiation factor is limited by a maximum value of 1;

Copyright SFA - InterNoise 2000 2 The value of the sound reduction index around the critical frequency is taken to be at least the same as the highest value calculated for lower frequencies; this means that the curve showing the sound reduction index as a function of the frequency is flat around the critical frequency; The calculated sound reduction index is corrected by 5 lg(m /200), where m is the mass per unit area of the element [kg/m 2 ]. For wooden floors on joists the sound reduction improvement measured in a laboratory is used. Comparisons between predicted and measured values in figure 1 show good agreement. (a) (b) Figure 1: Two examples of sound insulation for a 160 mm thick concrete floor with wooden floor on joists. 3 - ACADEMIES OF MUSIC Measurements of airborne sound insulation have been performed in academies of music for an extended frequency range down to 50 Hz. The measurements were carried out as described in EN ISO 140-4 for the frequency range 100-3150 Hz but with stricter requirements regarding measurement periods, number of source positions etc. The left hand graph of figure 2 shows the measurement result for a 230 mm thick brick wall with linings of 2 12.5 mm plaster board without connections to the wall on each side. The cavities are 100 mm deep and provided with mineral wool. The flanking constructions are: 350 mm thick brickwork façade with the same lining as described above; Lightweight double internal wall; Approximately 200 mm concrete floor with 2 19 mm plaster board on 50 mm mineral wool; 180 mm hollow concrete slab with a suspended ceiling of 2 12.5 mm plaster board. Predicted values using the same procedure as described in section 2 are also given in figure 2. Because of lack of measurement data for the floating floor, the sound reduction improvement was taken from laboratory measurements for a 50 mm thick floating concrete floor on 30 mm mineral wool. For the linings the sound reduction improvement was calculated as described in [4]. The measured and calculated R w -values are 74 db and 75 db respectively. The sound transmission has been analysed for different transmission paths with the prediction model, and subjective investigations took place by listening to the vibrations of the surfaces in the building. It turned out that the relatively low sound insulation at 50-63 Hz was related to the mass-spring resonance of the linings, and that flanking transmission through the floor was very important at higher frequencies. In figure 2 measurement results are also given for constructions with more efficient linings and floating floors (right hand graph). Predictions have not been possible because no data were available for the sound reduction improvement of the applied floating concrete floors. The constructions in the building are: Separating walls of 230 mm brickwork with linings on each side; Façade inner leaves of 170 mm brickwork with linings;

Copyright SFA - InterNoise 2000 3 Lightweight double inner walls; 220 mm concrete floors with 80 mm floating concrete on 100 mm mineral wool and on the top a wooden floor on joists with mineral wool in the cavity; suspended ceilings. All linings and suspended ceilings are 3 12.5 mm plaster board mounted with rubber vibration isolators and a cavity depth of 150 mm, including 100 mm mineral wool. The linings are placed on the floating floors. The total thickness of the separating wall construction is 610 mm, and the mass per unit area is approximately 450 kg/m 2. In other buildings with 200 mm thick concrete walls and linings R w -values up to 90 db have been measured. (a) (b) Figure 2: The left hand graph shows the sound insulation for 230 mm brickwork with 125 mm linings on both sides; the right hand graph shows the measured sound insulation for 230 mm brickwork with 190 mm linings on both sides and for a 220 mm concrete floor with suspended ceiling, floating concrete floor and wooden floor (total thickness approx. 700 mm). 4 - LIGHTWEIGHT CONSTRUCTIONS In a considerable number of dwellings airborne and impact sound insulation have been measured in a wide frequency range including very low frequencies. In figures 3, 4, 5 the sound insulation for conventional heavy constructions with floorings or floating floors is compared with results from new buildings with lightweight double constructions. Each curve shows the average for 9-10 measurements for heavy constructions and 4-5 measurements for lightweight constructions. Measurement results are shown both with and without corrections for the absorption of the receiving room, because the reverberation time was not measured below 50 Hz. Results are missing at some frequencies because of background noise. The lightweight constructions are typically 300-400 mm thick, and the walls are provided with 2-3 layers of plaster board on each side. Lightweight floors are heavier and more complicated than walls, partly because heavier materials have been used in the constructions, and partly because the load bearing system of steel or wood of course is more elaborated for floors than for walls. Figures 3, 4, 5 show that above 100 Hz the sound insulation is higher for the lightweight double constructions than for the conventional heavy constructions. In average R w is 61 db for all lightweight constructions investigated. However, it is clearly demonstrated that at very low frequencies the heavy constructions have a higher sound insulation than lightweight double constructions. The difference between lightweight and heavy constructions is 7-20 db at 25-50 Hz. Thus, high R w - and low L n,w -values for lightweight constructions are not sufficient for obtaining a high acoustic quality. Extending the frequency range down to 50 Hz and introducing the relevant adaptation terms in informative annexes of EN ISO 717 will to some extent take this into account. 5 - CONCLUSION Measurement results from new Danish dwellings with R w values around 60 db have been presented in this paper. Both heavy constructions with wooden floors on joists and lightweight constructions are included. The presented values of R w are 5-8 db higher than in typical existing Danish dwellings where the sound insulation fulfils the requirements of the Danish building code. However, for new lightweight

Copyright SFA - InterNoise 2000 4 Figure 3: Airborne sound insulation horizontally, average for different buildings. double constructions with R w values around 60 db, the sound insulation at low frequencies is lower than for conventional Danish building constructions used in existing dwellings. This is the case for airborne as well as impact sound insulation. Extension of the frequency range down to 50 Hz and application of spectral adaptation terms according to informative annexes of EN ISO 717 part 1 and 2 can improve the evaluation of sound insulation. The standard for prediction of sound insulation, EN 12354-1 has proved to be useful when new constructions are introduced, provided that acoustic data are available for all constructions of the building. This has been demonstrated for constructions used in dwellings and in academies of music where the acoustic requirements are considerably higher. For Danish buildings lack of reliable acoustic data for floating floors is probably the most serious limitation for application of the standard in buildings with high sound insulation. ACKNOWLEDGEMENTS The measurements described in section 4 were carried out under a project supported by the Danish Technical Research Council. REFERENCES 1. EN 12354-1, Building Acoustics, Estimation of acoustic performance of buildings from the performance of elements, Part 1: Airborne sound insulation between rooms.version from CEN, Brussels, 1997 2. S. Ljunggren, Airborne sound insulation of thin walls, J. Acoust. Soc. Am., Vol. 89(5), pp. 2324-2337, 1991 3. D. B. Pedersen, Evaluation of EN 12354 part 1 and 2 for Nordic dwelling houses, Journal of Building Acoustics, Vol. 6(3-4), pp. 259-268, 1999 4. D. B. Pedersen, Nordic basis of calculation of sound insulation in buildings, NT Technical Report 425, DELTA Acoustics & Vibration, Aarhus, 1998

Copyright SFA - InterNoise 2000 Figure 4: Airborne sound insulation vertically, average for different buildings. Figure 5: Impact sound insulation vertically, average for different buildings. 5