Serial Communications Module RS232

Similar documents
5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

OPT SERIAL TO FIBER OPTIC CONVERTER

Options for ABB drives, converters and inverters. User s manual FDPI-02 diagnostics and panel interface

Perle Protocol Transparent Media Converter Modules

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

1-Port R422/485 Serial PCIe Card

SYSTEM 4C. C R H Electronics Design

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY METRIC SPECIFICATIONS FOR RS232 LEASED LINE MODEMS (LOW SPEED MODEL 400)

Communication Unit 560CMU05 Data sheet

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

ELAN DIGITAL SYSTEMS LTD. SL232 PC- CARD USER S GUIDE

PCS0100en Persy Control Services B.V. Netherlands

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

Advanced Data Capture and Control Systems

NC-12 Modbus Application

ZC-24DO CANopen I/O Module: 24 Digital Outputs

=============================== WARNING

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

MSL1000 Monitored Serial Link Interface Manual V1.01

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Using Xbee in Serial Communication

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

ALL-USB-RS422/485. User Manual. USB to Serial Converter RS422/485. ALLNET GmbH Computersysteme Alle Rechte vorbehalten

SYSTEM 45. C R H Electronics Design

OZW30. Central Unit SYNERGYR

MCR1900 Media Converter 19-Slot Chassis

Modular I/O System Analog and Digital Interface Modules

Designing VM2 Application Boards

Manual Serial PCI Cards

F2400 FOM II Series Fiber Optic Modem Technical Manual

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Repeaters and Mimics Data Sheet

Bluetooth to Serial Adapter

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

HCR3.2/.. Chipcard reader HOTEL SOLUTION

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

Technical description MX-1 VB Edge

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

easyraid Q12 Hardware User Manual

User manual Compact Web PLC WP240 series IEC-line

SB-2000 USB Radio Interface Operating Manual CG Antenna Co. Ltd.

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

TX2123 RS485 TO ETHERNET ADAPTOR

Bluetooth UART/RS232 Module

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Disturbance Recoder SPCR 8C27. Product Guide

Rack mounted telephone- and leased line modem for industrial applications

Tyan Computer. Transport PX22. Service Engineer s Manual

User Manual IC-485AI

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

RC2200DK Demonstration Kit User Manual

2-Port RS232/422/485 Combo Serial PCI Card

USB to RS-422/485 Serial Adapter

Cable Specifications and Information

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Modbus Communications for PanelView Terminals

Moxa TCC-100/100I User s Guide

1 light dimming module

BEC 6200WZL. 4G/LTE Cellular Broadband Router. Quick Start Guide

Digital Keypad Use s Manual

Industrial Bar Code Scanners

Series Six Plus Programmable Controller

PCAN-ISA. CAN Interface for ISA. User Manual

Industrial Bar Code Scanners

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

Processor. User Guide

USB to RS-422/485 Serial Adapter (ID-SC0911-S1/SC0A11-S1) User s Manual

UniStream CPU-for-Panel

Backup Scanner Module

Industrial Multi-port Serial Cards

HP UPS R1500 Generation 3

Telephone- and leased line modem for industrial applications TD-36

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

PD 100A. Printing data system

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

EATS16 EATS16N. Installation and user manual ENGLISH. Copyright 2015 EATON All rights reserved.

FOM-5A, 6A. Asynchronous Fiber Optic Modem

TX OPEN RS232/485 module

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Hardware Specifications of V2AF Series Hybrid Card Reader

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Cisco T1 Layer 1 Troubleshooting

Installation and Operation Manual. Intraplex. DA-191B Four-Port Asynchronous Data Module. Version 1. GatesAir.com

RS232 Board datasheet

Batch Processor (LSC-B)

ATA TO IDE INTERFACE PC CARD DRIVES

Chapter 4 T1 Interface Card

PCMCIA 1 Port RS EDITION OCTOBER 1999

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

XBee USB Adapter Board (#32400)

Foxboro Evo Process Automation System

SyncLink GT2/GT4 Serial Adapter

DLP-PU/E Instruction Manual

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Transcription:

MSR04XI Serial Communications Module RS232 (MSR04XI) Issue 8 October 2005 INTRODUCTION AND TECHNICAL DATA PURPOSE The Serial Communications Module provides a serial interface between the SC300E environment and a variety of remote devices complying with the standard RS232-C. At least one Serial Communications Module must be used in the system and fitted in Slot 10 of the main chassis to enable communications between the system processors and the workstations. The workstation link is used for loading the application software and monitoring ladder and diagnostic functions. The link utilises Port 0 of the module. Additional modules can be fitted to any other I/O slot, wrong slotting is prevented by mechanical coding blocks (Figure 2-1 ). The system software identifies the module via a built-in hardware identifier. Circuit triplication and voting procedures make the module single fault tolerant and front panel indicators show Tx/Rx activity, the circuit on-line status and the health of the module. Communications connections are via four identical ports on the front panel (Ports 0 to 3) and these connections are duplicated on the field connector (J2) at the rear. A fifth port is for diagnostic purposes only. The module is compatible with single slot hot repair and the front panel has a switch to enable a request that the module be taken off line. This document is intended to provide a general understanding of the function of Serial Communications Module, sufficient to enable basic maintenance operations to be effected in the field. 008-5099

Ejector lever Mechanical coding block (Upper) Connector J1 User COMMports Diagnosticport (Voltage Mon) Link LK2 (Module ID) Link LK2 Link LK4 Tx / Rx LEDs Health LED ON/OFF LEDs ON/OFF Line Request switch Connector J2 RS232 Daughterboard Ejector lever Mechanical coding block (Lower) 2 MSR04XI October 2005 Issue 8

MSR04XI Serial Communications Module RS232 ASSOCIATED DOCUMENTATION Reference No Title 008-5097 Chassis User Manual SPECIFICATION Model Communications Mictrocontroller MSR04XI Serial RS232 Intel family Communication ports: Port 0: RS232 9600 or 19200 Baud Port 1: Port 2: Port 3: RS232 9600 or 19200 Baud RS232 9600 or 19200 Baud (see Note) RS232 9600 or 19200 Baud (see Note) Diagnostic: for diagnostics purposes only Note: Ports 2 & 3 must be set to the same Baud rate. rate. Isolation Indicators Hot repair procedure Ports 0 to 3, 1kV Tx, Rx, Health, 3 x On Line Single slot Module power consumption 3.5W Overall size (mm) Overall size (inches) Weight 400(9U)H x 397L x 28W 15.75H x 15.63L x 1.1W 1.3kg MSR04XI October 2005 Issue 8 3

ENVIRONMENTAL SPECIFICATIONS The maximum ambient temperature measured at the hottest point within the Triguard system shall not be greater than 60 degrees centigrade. Temperature operating: +5 C to +60 C Temperature storage: -25 C to +70 C Humidity 5% to 95% non-condensing at ambient <40 C EMC/RFI Immunity Tested and certified to IEC 1131-Part 2 1994 Vibration/Shock Tested and certified to IEC 1131-Part 2 1994 Certification: General Certification: Ref. SC300E Product Guide (ref 008-5209) TRANSPORT AND HANDLING The MSR04XI module must be transported and stored in its original packing material which should be retained for this purpose. 4 MSR04XI October 2005 Issue 8

MSR04XI Serial Communications Module RS232 TECHNICAL DESCRIPTION PHYSICAL The Serial Communications Module is a 9U high PCB with integral front panel and front and rear connectors; a plug-in daughter board carries the RS232 interface circuits. Figure 1-1 shows the general layout, location of the connectors and front panel components. Mechanical coding blocks All Input/Output modules carry two mechanical coding blocks equipped with pins which mate with holes in corresponding blocks in the chassis and prevent the module being inserted into the wrong slot. The pins in the module blocks are factory installed in a pattern determined by the module and corresponding set screws are removed from the chassis coding blocks to enable fitting. Unused holes are plugged with set screws. The chassis mechanical coding block configuration for this module is shown in Figure 2-1. Figure 2-1 Chassis mechanical coding block configurations Links The PCB has a total of nine links. For the top section of the PCB the links are located and configured as follows: Three LK1 links (3-pin) located approximately 80mm down from the top of the module, not user configurable, link not fitted. Three LK2 links (8-pin) located approximately 210mm down from the top of the module - Module ID links which should always be fitted (refer to Figure 1-1). MSR04XI October 2005 Issue 8 5

On the lower section of the PCB are three further links, LK2, LK3 and LK4, located and configured as follows: LK2 (2-pin) located approximately 220mm down from the top of the module and 110mm in from the front face, used in the voltage monitoring circuit, always fitted. LK3 (3 -pin) located beneath the plug in daughterboard. Used for 3-2-1-or 3-2-0 operation, factory fitted hard wired, all pins linked for 3-2-1 mode. LK4 (3-pin) located approximately 250mm down from the top of the module and 220mm from the front face, used for the daughterboard clock speed setting, pins 1 and 2 linked. Table 2-1. Default link settings Link LK1 (3 off x 3 pin) LK2 (3 off x 8 pin) LK2 (2 pin) LK3 (3 pin) LK4 (3 pin) Default setting Links not fitted Fitted Fitted Hard wired (all pins linked) Fitted (pins 1 & 2 linked) 6 MSR04XI October 2005 Issue 8

MSR04XI Serial Communications Module RS232 EXTERNAL CONNECTIONS Pinouts and signals for front panel connectors J4 to J6 through to J2 backplane are given in Table 2-2. Is your interface DTE (data terminal equipment) or DCE (data communications equipment)?: The point of reference for all signals is the terminal (or PC). Transmit and receive leads (2 or 3) can be reversed depending on the use of the equipment, either DTE or DCE. Table 2-2. Front panel & backplane connector pinouts with signals Port 0 J2 Port 1 J2 (9-way) (backplane (9-way) (backplane) 1 n/c 2 Rx A4 3 Tx C2 4 n/c 5 Ground A6 6 n/c n/c 7 RTS A2 8 CTS C4 9 n/c n/c 1 n/c 2 Rx A12 3 Tx C10 4 n/c 5 Ground A14 6 n/c n/c 7 RTS A10 8 CTS C12 9 n/c n/c Port 2 J2 Port 3 J2 (9-way) (backplane) (9-way) (backplane) 1 n/c 2 Rx A20 3 Tx C18 4 n/c 5 Ground A22 6 n/c n/c 7 RTS A18 8 CTS C20 9 n/c n/c 1 n/c 2 Rx A28 3 Tx C26 4 n/c 5 Ground A30 6 n/c n/c 7 RTS A26 8 CTS C28 9 n/c n/c n/c =No connection Wiring schematic for serial communication cables are shown in Figure 2-2. MSR04XI October 2005 Issue 8 7

8 MSR04XI October 2005 Issue 8

MSR04XI Serial Communications Module RS232 Figure 2-2 Serial communications cable wiring THEORY OF OPERATION Triplicated data enters and leaves the module (Figure 2-3 ) via the chassis backplane connector J1 and is isolated from the MPP by bus transceivers. Data for transmission is loaded into dual port RAM in each of the three circuit branches and is voted 2-oo-3 before being passed to the USARTs on the daughter board where it is serialised and sent to the appropriate communications port. Data received at the ports is converted to parallel form by the USART and written to dual port RAM in each branch, the data is accompanied by information about the status of the ports and the embedded microprocessor. The dual port memory is then read by the MPP via a second set of transceivers. The four communications ports are configured to run in full duplex mode using an RS232 interface and having a maximum rate of 19200 Baud. The communications ports are isolated from the module circuits by opto-isolators and connected to field connector J2 at the rear of the module. The ports are capable of powering modems or line drivers for transmission over long distances. Power for the module circuits is derived from the dual redundant SC300E power supply units, individual auctioneering and regulating circuits supplying various logic areas. The communications port opto-isolators and interfaces also have separate supplies. MSR04XI October 2005 Issue 8 9

Figure 2-3 Serial communications module Block diagram 10 MSR04XI October 2005 Issue 8

MSR04XI Serial Communications Module RS232 SERVICING SCOPE CAUTION: 1 The module contains components that may be electrostatically sensitive, it should be transported and stored in its original packaging material. System repair is by module replacement. Faulty modules are not repairable in the field; they should be returned for repair. DIAGNOSIS The TriBuild workstation is used for fault diagnosis. In the case of an Input/Output fault the Health LED on the faulty module will be extinguished. REMOVAL AND REPLACEMENT CAUTION 2 Failure to take the faulty module off-line before removing it from the chassis could trigger a fault alarm or cause plant shutdown. CAUTION 3 When inserting a module ensure that it is aligned with the markings on the chassis rails and that it engages with the upper and lower guides. Improper insertion may cause damage to the module and/or chassis connectors. Operate the On/off Line Request switch on the faulty module, the three On Line LEDs should all extinguish to indicate that the MPPs have recognised the request and taken the module offline. Slacken the two module securing screws and use the black ejection levers (top and bottom) to draw the module from its slot. Insert the new module ensuring that it engages properly in the upper and lower guides in the chassis, the top and bottom chassis rails carry alignment marks to assist. Pull out the ejection levers and as the module is pushed back engage the levers on the chassis rails. The levers should then be used to draw the module into position, some resistance will be felt as the rear connector pins engage. The module should be fixed in position with the securing screws. MSR04XI October 2005 Issue 8 11

Operate the On/off Line Request switch and check that the three On Line LEDs illuminate for one second, extinguish for one second and then illuminate permanently to indicate that the module has been put on-line. If the LEDs do not illuminate either the first or second time or fail to remain illuminated, then the module must be considered faulty. PREVENTIVE MAINTENANCE No preventive maintenance is necessary. 12 MSR04XI October 2005 Issue 8

MSR04XI Serial Communications Module RS232 SERVICE SUPPORT SPARE PARTS Spare parts and technical advice can be obtained from your local area office. MSR04XI October 2005 Issue 8 13